Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Andreas Heile is active.

Publication


Featured researches published by Andreas Heile.


Langmuir | 2010

Carbohydrate Microarrays by Microcontact Printing

Christian Wendeln; Andreas Heile; Heinrich F. Arlinghaus; Bart Jan Ravoo

This Article describes the preparation of carbohydrate microarrays by the immobilization of carbohydrates via microcontact printing (microCP) on glass and silicon substrates. To this end, diene-modified carbohydrates (galactose, glucose, mannose, lactose, and maltose) were printed on maleimide-terminated self-assembled monolayers (SAMs). A Diels-Alder reaction occurred exclusively in the contact area between stamp and substrate and resulted in a carbohydrate pattern on the substrate. It was found that cyclopentadiene-functionalized carbohydrates could be printed within minutes at room temperature, whereas furan-functionalized carbohydrates required long printing times and high temperatures. By successive printing, microstructured arrays of up to three different carbohydrates could be produced. Immobilization and patterning of the carbohydrates on the surfaces was investigated with contact angle measurements, X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), and fluorescence microscopy. Furthermore, the lectins concanavalin A (ConA) and peanut agglutinin (PNA) bind to the microarrays, and the printed carbohydrates retain their characteristic selectivity toward these proteins.


Analytical Chemistry | 2008

Effects of Metal Nanoparticles on the Secondary Ion Yields of a Model Alkane Molecule upon Atomic and Polyatomic Projectiles in Secondary Ion Mass Spectrometry.

Nimer Wehbe; Andreas Heile; Heinrich F. Arlinghaus; Patrick Bertrand; Arnaud Delcorte

A model alkane molecule, triacontane, is used to assess the effects of condensed gold and silver nanoparticles on the molecular ion yields upon atomic (Ga(+) and In(+)) and polyatomic (C60(+) and Bi3(+)) ion bombardment in metal-assisted secondary ion mass spectrometry (MetA-SIMS). Molecular films spin-coated on silicon were metallized using a sputter-coater system, in order to deposit controlled quantities of gold and silver on the surface (from 0 to 15 nm equivalent thickness). The effects of gold and silver islets condensed on triacontane are also compared to the situation of thin triacontane overlayers on metallic substrates (gold and silver). The results focus primarily on the measured yields of quasi-molecular ions, such as (M - H)(+) and (2M - 2H)(+), and metal-cationized molecules, such as (M + Au)(+) and (M + Ag)(+), as a function of the quantity of metal on the surface. They confirm the absence of a simple rule to explain the secondary ion yield improvement in MetA-SIMS. The behavior is strongly dependent on the specific projectile/metal couple used for the experiment. Under atomic bombardment (Ga(+), In(+)), the characteristic ion yields an increase with the gold dose up to approximately 6 nm equivalent thickness. The yield enhancement factor between gold-metallized and pristine samples can be as large as approximately 70 (for (M - H)(+) under Ga(+) bombardment; 10 nm of Au). In contrast, with cluster projectiles such as Bi3(+) and C60(+), the presence of gold and silver leads to a dramatic molecular ion yield decrease. Cluster projectiles prove to be beneficial for triacontane overlayers spin-coated on silicon or metal substrates (Au, Ag) but not in the situation of MetA-SIMS. The fundamental difference of behavior between atomic and cluster primary ions is tentatively explained by arguments involving the different energy deposition mechanisms of these projectiles. Our results also show that Au and Ag nanoparticles do not induce the same behavior in MetA-SIMS of triacontane. The microstructures of the metallized layers are also different. While metallic substrates provide higher yields than metal islet overlayers in the case of silver, whatever the projectile used, the situation is reversed with gold.


Rapid Communications in Mass Spectrometry | 2008

Ion yield improvement for static secondary ion mass spectrometry by use of polyatomic primary ions

Roel De Mondt; Luc Van Vaeck; Andreas Heile; Heinrich F. Arlinghaus; Nicolas Nieuwjaer; Arnaud Delcorte; Patrick Bertrand; Jens Lenaerts; Frank Vangaever

Static secondary ion mass spectrometry (S-SIMS) is one of the potentially most powerful and versatile tools for the analysis of surface components at the monolayer level. Current improvements in detection limit (LOD) and molecular specificity rely on the optimisation of the desorption-ionisation (DI) process. As an alternative to monoatomic projectiles, polyatomic primary ion (P.I.) bombardment increases ion yields non-linearly. Common P.I. sources are Ga+ (liquid metal ion gun (LMIG), SF5+ (electron ionisation) and the newer Au(n)+, Bi(n)q+ (both LMIG) and C60+ (electron ionisation) sources. In this study the ion yield improvement obtained by using the newly developed ion sources is assessed. Two dyes (zwitterionic and/or thermolabile polar functionalities on a largely conjugated backbone) were analysed as a thin layer using Ga+, SF5+, C60+, Bi+, Bi3(2+) and Bi5(2+) projectiles under static conditions. The study aims at evaluating the improvement in LOD, useful and characteristic yield and molecular specificity. The corrected total ion count values for the different P.I. sources are compared for different instruments to obtain a rough estimate of the improvements. Furthermore, tentative ionisation and fragmentation schemes are provided to describe the generation of radical and adduct ions. Characteristic ion yields are discussed for the different P.I. sources. An overview of the general appearances of the mass spectra obtained with the different P.I. sources is given to stress the major improvement provided by polyatomic P.I.s in yielding information at higher m/z values.


Analytical and Bioanalytical Chemistry | 2009

TOF-S-SIMS molecular depth profiling of organic bilayers using mechanical wear test methodology

Roel De Mondt; Luc Van Vaeck; Andreas Heile; Heinrich F. Arlinghaus; Frank Vangaever; Jens Lenaerts

AbstractRecent publications on static secondary ion mass spectrometry (S-SIMS) focus on molecular depth profiling by using polyatomic or ultra-low energy monoatomic projectiles. Since their applicability depends on the relationship between the ion yield and the depth, which is hard to obtain without extensive studies, a combination of a wear test method with S-SIMS surface analysis was performed in the current study. Using this non-sputtering procedure, the relation between the signal intensity and the local concentration remains in principle the same as that at the surface (which is easy to determine). Mechanical erosion was successfully applied to expose sub-surface material from organic multilayers. Through surface analysis with S-SIMS on the gradually exposed deeper planes, molecular depth profiles could be obtained. The study was conducted on a model system relevant to offset printing, consisting of two polymer layers, containing dyes and a surfactant, cast on an Al substrate. FigureConcept of mechanical erosion followed by S-SIMS surface analysis to obtain molecular depth profiles


Journal of Power Sources | 2010

PPy doped PEG conducting polymer films synthesized on LiFePO4 particles

Andrea Fedorková; Renáta Oriňáková; Andrej Oriňák; Ivan Talian; Andreas Heile; Hans-Dieter Wiemhöfer; Dušan Kaniansky; Heinrich F. Arlinghaus


Applied Surface Science | 2008

Metal-assisted SIMS and cluster ion bombardment for ion yield enhancement

Andreas Heile; D. Lipinsky; Nimer Wehbe; Arnaud Delcorte; Patrick Bertrand; Alexandre Felten; L. Houssiau; Jean-Jacques Pireaux; R. De Mondt; L. Van Vaeck; Heinrich F. Arlinghaus


Surface and Interface Analysis | 2008

Investigation of methods to enhance the secondary ion yields in TOF-SIMS of organic samples

Andreas Heile; D. Lipinsky; Nimer Wehbe; Arnaud Delcorte; Patrick Bertrand; Alexandre Felten; L. Houssiau; Jean-Jacques Pireaux; R. De Mondt; P. Van Royen; L. Van Vaeck; Heinrich F. Arlinghaus


Surface and Interface Analysis | 2011

Investigations of secondary ion yield-enhancing methods in combination †

Andreas Heile; Christian Muhmann; D. Lipinsky; Heinrich F. Arlinghaus


Surface and Interface Analysis | 2008

Influence of different primary ion species on the secondary ion emission from PNA/DNA biosensor surfaces

Sebastian Hellweg; Andreas Heile; Thomas Grehl; Heinrich F. Arlinghaus


Solid State Sciences | 2011

Electrochemical and TOF-SIMS investigations of PPy/PEG-modified LiFePO4 composite electrodes for Li-ion batteries

Andrea Fedorková; Renáta Oriňáková; Andrej Oriňák; Andreas Heile; Hans-Dieter Wiemhöfer; Heinrich F. Arlinghaus

Collaboration


Dive into the Andreas Heile's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Arnaud Delcorte

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

Patrick Bertrand

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

D. Lipinsky

University of Münster

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge