Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Andres Aguirre is active.

Publication


Featured researches published by Andres Aguirre.


Optics Express | 2009

A real-time photoacoustic tomography system for small animals

John Gamelin; Anastasios Maurudis; Andres Aguirre; Fei Huang; Puyun Guo; Lihong V. Wang; Quing Zhu

A real-time 512-element photoacoustic tomography system for small animal imaging using a ring ultrasound array has been developed. The system, based upon a 5 MHz transducer array formed along a 50 mm circular aperture, achieves sub-200 micron lateral resolution over a 2 cm disk-shaped region. Corresponding elevation resolutions of 0.6 to 2.5 mm over the central volume enable depth-resolved 3D tomographic imaging with linear translation. Using 8:1 electronic multiplexing, imaging at up to 8 frame/sec is demonstrated for both dynamic phantoms and in vivo mouse and brain samples. The real-time, full 2D tomographic capability of the system paves the way for functional photoacoustic tomographic imaging studies in small animals with sub-second time frame.


Journal of Biomedical Optics | 2010

Real-time photoacoustic tomography of cortical hemodynamics in small animals

Changhui Li; Andres Aguirre; John Gamelin; Anastasios Maurudis; Quing Zhu; Lihong V. Wang

For the first time, the hemodynamics within the entire cerebral cortex of a mouse were studied by using photoacoustic tomography (PAT) in real time. The PAT system, based on a 512-element full-ring ultrasound array, received photoacoustic signals primarily from a slice of 2-mm thickness. This system can provide high-resolution brain vasculature images. We also monitored the fast wash-in process of a photoacoustic contrast agent in the mouse brain. Our results demonstrated that PAT is a powerful imaging modality that can be potentially used to study small animal neurofunctional activities.


Radiology | 2010

Early-Stage Invasive Breast Cancers: Potential Role of Optical Tomography with US Localization in Assisting Diagnosis

Quing Zhu; Poornima Hegde; Andrew Ricci; Mark Kane; Edward Cronin; Yasaman Ardeshirpour; Chen Xu; Andres Aguirre; Scott H. Kurtzman; Peter J. Deckers; Susan Tannenbaum

PURPOSE To investigate the potential role of optical tomography in the near-infrared (NIR) spectrum with ultrasonographic (US) localization as a means of differentiating early-stage cancers from benign lesions of the breast. MATERIALS AND METHODS The protocol was approved by the institutional review boards and was HIPAA compliant; all participants signed an informed consent. One hundred seventy-eight consecutive women (mean age, 52 years; range, 21-89 years) who underwent US-guided biopsy were imaged with a hand-held probe consisting of a coregistered US transducer and an NIR imager. The lesion location provided by coregistered US was used to guide optical imaging. Light absorption was measured at two optical wavelengths. From this measurement, tumor angiogenesis was assessed on the basis of calculated total hemoglobin concentration (tHb) and was correlated with core biopsy results. For patients diagnosed with carcinomas and followed up with subsequent excision, the tHb was correlated with pathologic parameters. RESULTS There were two in situ carcinomas (Tis), 35 T1 carcinomas, 24 T2-T4 carcinomas, and 114 benign lesions. The mean maximum and mean average tHb of the Tis-T1 group were 102.0 micromol/L +/- 28.5 (standard deviation) and 71.9 micromol/L +/- 18.8, and those of the T2-T4 group were 100.3 micromol/L +/- 26.4 and 67.0 micromol/L +/- 18.3, respectively. The mean maximum and mean average tHb of the benign group were 55.1 micromol/L +/- 22.7 and 39.1 micromol/L +/- 14.9, respectively. Both mean maximum and mean average tHb levels were significantly higher in the malignant groups than they were in the benign group (P < .001). The sensitivity, specificity, positive predictive value, and negative predictive value for Tis-T1 cancers were 92%, 93%, 81%, and 97%. The corresponding values for T2-T4 tumors were 75%, 93%, 69%, and 95%. CONCLUSION The angiogenesis (tHb) contrast imaged by using the NIR technique with US holds promise as an adjunct to mammography and US for distinguishing early-stage invasive breast cancers from benign lesions.


Journal of Biomedical Optics | 2009

Coregistered three-dimensional ultrasound and photoacoustic imaging system for ovarian tissue characterization

Andres Aguirre; Puyun Guo; John Gamelin; Shikui Yan; Mary M. Sanders; Molly Brewer; Quing Zhu

Ovarian cancer has the highest mortality of all gynecologic cancers, with a five-year survival rate of only 30% or less. Current imaging techniques are limited in sensitivity and specificity in detecting early stage ovarian cancer prior to its widespread metastasis. New imaging techniques that can provide functional and molecular contrasts are needed to reduce the high mortality of this disease. One such promising technique is photoacoustic imaging. We develop a 1280-element coregistered 3-D ultrasound and photoacoustic imaging system based on a 1.75-D acoustic array. Volumetric images over a scan range of 80 deg in azimuth and 20 deg in elevation can be achieved in minutes. The system has been used to image normal porcine ovarian tissue. This is an important step toward better understanding of ovarian cancer optical properties obtained with photoacoustic techniques. To the best of our knowledge, such data are not available in the literature. We present characterization measurements of the system and compare coregistered ultrasound and photoacoustic images of ovarian tissue to histological images. The results show excellent coregistration of ultrasound and photoacoustic images. Strong optical absorption from vasculature, especially highly vascularized corpora lutea and low absorption from follicles, is demonstrated.


Biomedical Optics Express | 2011

Integrated optical coherence tomography, ultrasound and photoacoustic imaging for ovarian tissue characterization

Yi Yang; Xiang Li; Tianheng Wang; Patrick D. Kumavor; Andres Aguirre; Kirk Shung; Qifa Zhou; Melinda Sanders; Molly Brewer; Quing Zhu

Ovarian cancer has the lowest survival rate of the gynecologic cancers because it is predominantly diagnosed in Stages III or IV due to the lack of reliable symptoms, as well as the lack of efficacious screening techniques. Detection before the malignancy spreads or at the early stage would greatly improve the survival and benefit patient health. In this report, we present an integrated optical coherence tomography (OCT), ultrasound (US) and photoacoustic imaging (PAI) prototype endoscopy system for ovarian tissue characterization. The overall diameter of the prototype endoscope is 5 mm which is suitable for insertion through a standard 5-12.5mm endoscopic laparoscopic port during minimally invasive surgery. It consists of a ball-lensed OCT sample arm probe, a multimode fiber having the output end polished at 45 degree angle so as to deliver the light perpendicularly for PAI, and a high frequency ultrasound transducer with 35MHz center frequency. System characterizations of OCT, US and PAI are presented. In addition, results obtained from ex vivo porcine and human ovarian tissues are presented. The optical absorption contrast provided by PAI, the high resolution subsurface morphology provided by OCT, and the deeper tissue structure imaged by US demonstrate the synergy of the combined endoscopy and the superior performance of this hybrid device over each modality alone in ovarian tissue characterization.


Journal of Biomedical Optics | 2011

Three-dimensional photoacoustic tomography based on the focal-line concept

Jun Xia; Zijian Guo; Konstantin Maslov; Andres Aguirre; Quing Zhu; Christopher J. Percival; Lihong V. Wang

A full ring ultrasonic array-based photoacoustic tomography system was recently developed for small animal brain imaging. The 512-element array is cylindrically focused in the elevational direction, and can acquire a two-dimensional (2D) image in 1.6 s. In this letter, we demonstrate the three-dimensional (3D) imaging capability of this system. A novel 3D reconstruction algorithm was developed based on the focal-line concept. Compared to 3D images acquired simply by stacking a series of 2D images, the 3D focal-line reconstruction method renders images with much less artifacts, and improves the elevational resolution by 30% and the signal-to-noise ratio by two times. The effectiveness of the proposed algorithm was first validated by numerical simulations and then demonstrated with a hair phantom experiment and an ex vivo mouse embryo experiment.


Technology in Cancer Research & Treatment | 2006

Optimal probing of optical contrast of breast lesions of different size located at different depths by US localization

Quing Zhu; Chen Xu; Puyun Guo; Andres Aguirre; Baohong Yuan; Fei Huang; Diego Castilo; John Gamelin; Susan Tannenbaum; Mark Kane; Poornima Hegde; Scott H. Kurtzman

We report a frequency domain optical tomography system utilizing three RF modulation frequencies, which are optimized for probing breast lesions of different size located at different depths. A real-time co-registered ultrasound scanner is used to provide on-site estimation of lesion size and location. Based on the lesion information, an optimal light modulation frequency can be selected, which may yield more accurate estimates of lesion angiogenesis and hypoxia. Phantom experiments have demonstrated that a high modulation frequency, such as 350Mhz, is preferable for probing small lesions closer to the surface while a low modulation frequency, such as 50Mhz, is desirable for imaging deeper and larger lesions. A clinical example of a large invasive carcinoma is presented to demonstrate the application of this novel technique.


IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2012

FPGA-based reconfigurable processor for ultrafast interlaced ultrasound and photoacoustic imaging

Umar Alqasemi; Hai Li; Andres Aguirre; Quing Zhu

In this paper, we report, to the best of our knowledge, a unique field-programmable gate array (FPGA)-based reconfigurable processor for real-time interlaced co-registered ultrasound and photoacoustic imaging and its application in imaging tumor dynamic response. The FPGA is used to control, acquire, store, delay-and-sum, and transfer the data for real-time co-registered imaging. The FPGA controls the ultrasound transmission and ultrasound and photoacoustic data acquisition process of a customized 16-channel module that contains all of the necessary analog and digital circuits. The 16-channel module is one of multiple modules plugged into a motherboard; their beamformed outputs are made available for a digital signal processor (DSP) to access using an external memory interface (EMIF). The FPGA performs a key role through ultrafast reconfiguration and adaptation of its structure to allow real-time switching between the two imaging modes, including transmission control, laser synchronization, internal memory structure, beamforming, and EMIF structure and memory size. It performs another role by parallel accessing of internal memories and multi-thread processing to reduce the transfer of data and the processing load on the DSP. Furthermore, because the laser will be pulsing even during ultrasound pulse-echo acquisition, the FPGA ensures that the laser pulses are far enough from the pulse-echo acquisitions by appropriate time-division multiplexing (TDM). A co-registered ultrasound and photoacoustic imaging system consisting of four FPGA modules (64-channels) is constructed, and its performance is demonstrated using phantom targets and in vivo mouse tumor models.


Journal of Biomedical Optics | 2013

Photoacoustic imaging enhanced by indocyanine green-conjugated single-wall carbon nanotubes

Saeid Zanganeh; Hai Li; Patrick D. Kumavor; Umar Alqasemi; Andres Aguirre; Innus Mohammad; Courtney Stanford; Michael B. Smith; Quing Zhu

Abstract. A photoacoustic contrast agent that is based on bis-carboxylic acid derivative of indocyanine green (ICG) covalently conjugated to single-wall carbon nanotubes (ICG/SWCNT) is presented. Covalently attaching ICG to the functionalized SWCNT provides a more robust system that delivers much more ICG to the tumor site. The detection sensitivity of the new contrast agent in a mouse tumor model is demonstrated in vivo by our custom-built photoacoustic imaging system. The summation of the photoacoustic tomography (PAT) beam envelope, referred to as the “PAT summation,” is used to demonstrate the postinjection light absorption of tumor areas in ICG- and ICG/SWCNT-injected mice. It is shown that ICG is able to provide 33% enhancement at approximately 20 min peak response time with reference to the preinjection PAT level, while ICG/SWCNT provides 128% enhancement at 80 min and even higher enhancement of 196% at the end point of experiments (120 min on average). Additionally, the ICG/SWCNT enhancement was mainly observed at the tumor periphery, which was confirmed by fluorescence images of the tumor samples. This feature is highly valuable in guiding surgeons to assess tumor boundaries and dimensions in vivo and to achieve clean tumor margins to improve surgical resection of tumors.


Journal of Biomedical Optics | 2011

Imaging tumor hypoxia by near-infrared fluorescence tomography

Nrusingh C. Biswal; Christopher Pavlik; Michael B. Smith; Andres Aguirre; Yan Xu; Saeid Zanganeh; Liisa T. Kuhn; Kevin P. Claffey; Quing Zhu

We have developed a novel nitroimidazole indocyanine dye conjugate for tumor-targeted hypoxia fluorescence tomography. The hypoxia probe has been evaluated in vitro using tumor cell lines and in vivo with tumor targeting in mice. The in vitro cell studies were performed to assess fluorescence labeling differences between hypoxia and normoxia conditions. When treated with the hypoxia probe, a fluorescence emission ratio of 2.5-fold was found between the cells incubated under hypoxia compared to the cells in normoxia condition. Hypoxia specificity was also confirmed by comparing the cells treated with indocyanine dye alone. In vivo tumor targeting in mice showed that the fluorescence signals measured at the tumor site were twice those at the normal site after 150 min post-injection of the hypoxia probe. On the other hand, the fluorescence signals measured after injection of indocyanine dye were the same at tumor and normal sites. In vivo fluorescence tomography images of mice injected with the hypoxia probe showed that the probe remained for more than 5 to 7 h in the tumors, however, the images of mice injected with indocyanine only dye confirmed that the unbound dye washed out in less than 3 h. These findings are supported with fluorescence images of histological sections of tumor samples using a Li-COR scanner and immunohistochemistry technique for tumor hypoxia.

Collaboration


Dive into the Andres Aguirre's collaboration.

Top Co-Authors

Avatar

Quing Zhu

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar

John Gamelin

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lihong V. Wang

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Umar Alqasemi

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar

Fei Huang

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar

Saeid Zanganeh

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar

Puyun Guo

University of Connecticut

View shared research outputs
Top Co-Authors

Avatar

Yasaman Ardeshirpour

National Institutes of Health

View shared research outputs
Researchain Logo
Decentralizing Knowledge