Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Andrew G. Chambers is active.

Publication


Featured researches published by Andrew G. Chambers.


Proteomics | 2012

MRM‐based multiplexed quantitation of 67 putative cardiovascular disease biomarkers in human plasma

Dominik Domanski; Andrew J. Percy; Juncong Yang; Andrew G. Chambers; John S. Hill; Gabriela V. Cohen Freue; Christoph H. Borchers

A highly‐multiplexed MRM‐based assay for determination of cardiovascular disease (CVD) status and disease classification has been developed for clinical research. A high‐flow system using ultra‐high performance LC and an Agilent 6490 triple quadrupole mass spectrometer, equipped with an ion funnel, provided ease of use and increased the robustness of the assay. The assay uses 135 stable isotope‐labeled peptide standards for the quantitation of 67 putative biomarkers of CVD in tryptic digests of whole plasma in a 30‐min assay. Eighty‐five analyses of the same sample showed no loss of sensitivity (<20% CV for 134/135 peptides) and no loss of retention time accuracy (<0.5% CV for all peptides). The maximum linear dynamic range of the MRM assays ranged from 103–105 for 106 of the assays. Excellent linear responses (r >0.98) were obtained for 117 of the 135 peptide targets with attomole level limits of quantitation (<20% CV and accuracy 80–120%) for 81 of the 135 peptides. The assay presented in this study is easy to use, robust, sensitive, and has high‐throughput capabilities through short analysis time and complete automated sample preparation. It is therefore well suited for CVD biomarker validation and discovery in plasma.


Biochimica et Biophysica Acta | 2014

Advances in multiplexed MRM-based protein biomarker quantitation toward clinical utility

Andrew J. Percy; Andrew G. Chambers; Juncong Yang; Darryl B. Hardie; Christoph H. Borchers

Accurate and rapid protein quantitation is essential for screening biomarkers for disease stratification and monitoring, and to validate the hundreds of putative markers in human biofluids, including blood plasma. An analytical method that utilizes stable isotope-labeled standard (SIS) peptides and selected/multiple reaction monitoring-mass spectrometry (SRM/MRM-MS) has emerged as a promising technique for determining protein concentrations. This targeted approach has analytical merit, but its true potential (in terms of sensitivity and multiplexing) has yet to be realized. Described herein is a method that extends the multiplexing ability of the MRM method to enable the quantitation 142 high-to-moderate abundance proteins (from 31mg/mL to 44ng/mL) in undepleted and non-enriched human plasma in a single run. The proteins have been reported to be associated to a wide variety of non-communicable diseases (NCDs), from cardiovascular disease (CVD) to diabetes. The concentrations of these proteins in human plasma are inferred from interference-free peptides functioning as molecular surrogates (2 peptides per protein, on average). A revised data analysis strategy, involving the linear regression equation of normal control plasma, has been instituted to enable the facile application to patient samples, as demonstrated in separate nutrigenomics and CVD studies. The exceptional robustness of the LC/MS platform and the quantitative method, as well as its high throughput, makes the assay suitable for application to patient samples for the verification of a condensed or complete protein panel. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge.


Proteomics | 2013

Multiplexed MRM-based quantitation of candidate cancer biomarker proteins in undepleted and non-enriched human plasma

Andrew J. Percy; Andrew G. Chambers; Juncong Yang; Christoph H. Borchers

An emerging approach for multiplexed targeted proteomics involves bottom‐up LC‐MRM‐MS, with stable isotope‐labeled internal standard peptides, to accurately quantitate panels of putative disease biomarkers in biofluids. In this paper, we used this approach to quantitate 27 candidate cancer‐biomarker proteins in human plasma that had not been treated by immunoaffinity depletion or enrichment techniques. These proteins have been reported as biomarkers for a variety of human cancers, from laryngeal to ovarian, with breast cancer having the highest correlation. We implemented measures to minimize the analytical variability, improve the quantitative accuracy, and increase the feasibility and applicability of this MRM‐based method. We have demonstrated excellent retention time reproducibility (median interday CV: 0.08%) and signal stability (median interday CV: 4.5% for the analytical platform and 6.1% for the bottom‐up workflow) for the 27 biomarker proteins (represented by 57 interference‐free peptides). The linear dynamic range for the MRM assays spanned four orders‐of‐magnitude, with 25 assays covering a 103–104 range in protein concentration. The lowest abundance quantifiable protein in our biomarker panel was insulin‐like growth factor 1 (calculated concentration: 127 ng/mL). Overall, the analytical performance of this assay demonstrates high robustness and sensitivity, and provides the necessary throughput and multiplexing capabilities required to verify and validate cancer‐associated protein biomarker panels in human plasma, prior to clinical use.


Molecular & Cellular Proteomics | 2013

Multiplexed Quantitation of Endogenous Proteins in Dried Blood Spots by Multiple Reaction Monitoring - Mass Spectrometry

Andrew G. Chambers; Andrew J. Percy; Juncong Yang; Alexander G. Camenzind; Christoph H. Borchers

Dried blood spot (DBS) sampling, coupled with multiple reaction monitoring mass spectrometry (MRM-MS), is a well-established approach for quantifying a wide range of small molecule biomarkers and drugs. This sampling procedure is simpler and less-invasive than those required for traditional plasma or serum samples enabling collection by minimally trained personnel. Many analytes are stable in the DBS format without refrigeration, which reduces the cost and logistical challenges of sample collection in remote locations. These advantages make DBS sample collection desirable for advancing personalized medicine through population-wide biomarker screening. Here we expand this technology by demonstrating the first multiplexed method for the quantitation of endogenous proteins in DBS samples. A panel of 60 abundant proteins in human blood was targeted by monitoring proteotypic tryptic peptides and their stable isotope-labeled analogs by MRM. Linear calibration curves were obtained for 40 of the 65 peptide targets demonstrating multiple proteins can be quantitatively extracted from DBS collection cards. The method was also highly reproducible with a coefficient of variation of <15% for all 40 peptides. Overall, this assay quantified 37 proteins spanning a range of more than four orders of magnitude in concentration within a single 25 min LC/MRM-MS analysis. The protein abundances of the 33 proteins quantified in matching DBS and whole blood samples showed an excellent correlation, with a slope of 0.96 and an R2 value of 0.97. Furthermore, the measured concentrations for 80% of the proteins were stable for at least 10 days when stored at −20 °C, 4 °C and 37 °C. This work represents an important first step in evaluating the integration of DBS sampling with highly-multiplexed MRM for quantitation of endogenous proteins.


Journal of Proteome Research | 2013

Standardized protocols for quality control of MRM-based plasma proteomic workflows.

Andrew J. Percy; Andrew G. Chambers; Derek Smith; Christoph H. Borchers

Mass spectrometry (MS)-based proteomics is rapidly emerging as a viable technology for the identification and quantitation of biological samples, such as human plasma--the most complex yet commonly employed biofluid in clinical analyses. The transition from a qualitative to quantitative science is required if proteomics is going to successfully make the transition to a clinically useful technique. MS, however, has been criticized for a lack of reproducibility and interlaboratory transferability. Currently, the MS and plasma proteomics communities lack standardized protocols and reagents to ensure that high-quality quantitative data can be accurately and precisely reproduced by laboratories across the world using different MS technologies. Toward addressing this issue, we have developed standard protocols for multiple reaction monitoring (MRM)-based assays with customized isotopically labeled internal standards for quality control of the sample preparation workflow and the MS platform in quantitative plasma proteomic analyses. The development of reference standards and their application to a single MS platform is discussed herein, along with the results from intralaboratory tests. The tests highlighted the importance of the reference standards in assessing the efficiency and reproducibility of the entire bottom-up proteomic workflow and revealed errors related to the sample preparation and performance quality and deficits of the MS and LC systems. Such evaluations are necessary if MRM-based quantitative plasma proteomics is to be used in verifying and validating putative disease biomarkers across different research laboratories and eventually in clinical laboratories.


Expert Review of Proteomics | 2014

MRM for the verification of cancer biomarker proteins: recent applications to human plasma and serum.

Andrew G. Chambers; Andrew J. Percy; Romain Simon; Christoph H. Borchers

Accurate cancer biomarkers are needed for early detection, disease classification, prediction of therapeutic response and monitoring treatment. While there appears to be no shortage of candidate biomarker proteins, a major bottleneck in the biomarker pipeline continues to be their verification by enzyme linked immunosorbent assays. Multiple reaction monitoring (MRM), also known as selected reaction monitoring, is a targeted mass spectrometry approach to protein quantitation and is emerging to bridge the gap between biomarker discovery and clinical validation. Highly multiplexed MRM assays are readily configured and enable simultaneous verification of large numbers of candidates facilitating the development of biomarker panels which can increase specificity. This review focuses on recent applications of MRM to the analysis of plasma and serum from cancer patients for biomarker verification. The current status of this approach is discussed along with future directions for targeted mass spectrometry in clinical biomarker validation.


Journal of Proteomics | 2013

Method and platform standardization in MRM-based quantitative plasma proteomics ☆

Andrew J. Percy; Andrew G. Chambers; Juncong Yang; Angela M. Jackson; Dominik Domanski; Julia M. Burkhart; Albert Sickmann; Christoph H. Borchers

UNLABELLED There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. BIOLOGICAL SIGNIFICANCE The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics.


Molecular & Cellular Proteomics | 2015

Multiple Reaction Monitoring Enables Precise Quantification of 97 Proteins in Dried Blood Spots

Andrew G. Chambers; Andrew J. Percy; Juncong Yang; Christoph H. Borchers

The dried blood spot (DBS) methodology provides a minimally invasive approach to sample collection and enables room-temperature storage for most analytes. DBS samples have successfully been analyzed by liquid chromatography multiple reaction monitoring mass spectrometry (LC/MRM-MS) to quantify a large range of small molecule biomarkers and drugs; however, this strategy has only recently been explored for MS-based proteomics applications. Here we report the development of a highly multiplexed MRM assay to quantify endogenous proteins in human DBS samples. This assay uses matching stable isotope-labeled standard peptides for precise, relative quantification, and standard curves to characterize the analytical performance. A total of 169 peptides, corresponding to 97 proteins, were quantified in the final assay with an average linear dynamic range of 207-fold and an average R2 value of 0.987. The total range of this assay spanned almost 5 orders of magnitude from serum albumin (P02768) at 18.0 mg/ml down to cholinesterase (P06276) at 190 ng/ml. The average intra-assay and inter-assay precision for 6 biological samples ranged from 6.1–7.5% CV and 9.5–11.0% CV, respectively. The majority of peptide targets were stable after 154 days at storage temperatures from −20 °C to 37 °C. Furthermore, protein concentration ratios between matching DBS and whole blood samples were largely constant (<20% CV) across six biological samples. This assay represents the highest multiplexing yet achieved for targeted protein quantification in DBS samples and is suitable for biomedical research applications.


Journal of Proteomics | 2014

Enhanced sensitivity and multiplexing with 2D LC/MRM-MS and labeled standards for deeper and more comprehensive protein quantitation

Andrew J. Percy; Romain Simon; Andrew G. Chambers; Christoph H. Borchers

UNLABELLED Mass spectrometry (MS)-based protein quantitation is increasingly being employed to verify candidate protein biomarkers. Multiple or selected reaction monitoring-mass spectrometry (MRM-MS or SRM-MS) with isotopically labeled internal standards has proven to be a successful approach in that regard, but has yet to reach its full potential in terms of multiplexing and sensitivity. Here, we report the development of a new MRM method for the quantitation of 253 disease-associated proteins (represented by 625 interference-free peptides) in 13 LC fractions. This 2D RPLC/MRM-MS approach extends the depth and breadth of the assay by 2 orders of magnitude over pre-fractionation-free assays, with 31 proteins below 10 ng/mL and 41 proteins above 10 ng/mL now quantifiable. Standard flow rates are used in both chromatographic dimensions, and up-front depletion or antibody-based enrichment is not required. The LC separations utilize high and low pH conditions, with the former employing an ammonium hydroxide-based eluent, instead of the conventional ammonium formate, resulting in improved LC column lifetime and performance. The high sensitivity (determined concentration range: 15 mg/mL to 452 pg/mL) and robustness afforded by this method makes the full MRM panel, or subsets thereof, useful for the verification of disease-associated plasma protein biomarkers in patient samples. BIOLOGICAL SIGNIFICANCE The described research extends the breadth and depth of protein quantitation in undepleted and non-enriched human plasma by employing standard-flow 2D RPLC/MRM-MS in conjunction with a complex mixture of isotopically labeled peptide standards. The proteins quantified are mainly putative biomarkers of non-communicable (i.e., non-infectious) disease (e.g., cardiovascular or cancer), which require pre-clinical verification and validation before clinical implementation. Based on the enhanced sensitivity and multiplexing, this quantitative plasma proteomic method should prove useful in future candidate biomarker verification studies.


Journal of Proteome Research | 2014

Multiplexed MRM with Internal Standards for Cerebrospinal Fluid Candidate Protein Biomarker Quantitation.

Andrew J. Percy; Juncong Yang; Andrew G. Chambers; Romain Simon; Darryl B. Hardie; Christoph H. Borchers

Multiplexed quantitation is essential for discovering, verifying, and validating biomarkers for risk stratification, disease prognostication, and therapeutic monitoring. The most promising strategy for quantifying unverified protein biomarkers in biofluids relies on selected/multiple reaction monitoring (SRM or MRM) technology with isotopically labeled standards employed within a bottom-up proteomic workflow. Since cerebrospinal fluid (CSF) is an important fluid for studying central nervous system (CNS) related diseases, we sought to develop a rapid, antibody- and fractionation-free MRM-based approach with a complex mixture of peptide standards to quantify a highly multiplexed panel of candidate protein biomarkers in human CSF. Development involved peptide transition optimization, denaturation/digestion protocol evaluation, transition interference screening, and protein quantitation via peptide standard curves. The final method exhibited excellent reproducibility (average coefficient of variation of <1% for retention time and <6% for signal) and breadth of quantitation (130 proteins from 311 interference-free peptides) in a single 43-min run. These proteins are of high-to-low abundance with determined concentrations from 118 μg/mL (serum albumin) to 550 pg/mL (apolipoprotein C-I). Overall, the method consists of the most highly multiplexed and broadest panel of candidate protein biomarkers in human CSF reported thus far and is well suited for subsequent verification studies on patient samples.

Collaboration


Dive into the Andrew G. Chambers's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Derek Smith

University of Victoria

View shared research outputs
Top Co-Authors

Avatar

Yassene Mohammed

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar

Robert Popp

University of Victoria

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge