Anthony K. Au
University of Washington
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Anthony K. Au.
Angewandte Chemie | 2016
Anthony K. Au; Wilson Huynh; Lisa F. Horowitz; Albert Folch
The advent of soft lithography allowed for an unprecedented expansion in the field of microfluidics. However, the vast majority of PDMS microfluidic devices are still made with extensive manual labor, are tethered to bulky control systems, and have cumbersome user interfaces, which all render commercialization difficult. On the other hand, 3D printing has begun to embrace the range of sizes and materials that appeal to the developers of microfluidic devices. Prior to fabrication, a design is digitally built as a detailed 3D CAD file. The design can be assembled in modules by remotely collaborating teams, and its mechanical and fluidic behavior can be simulated using finite-element modeling. As structures are created by adding materials without the need for etching or dissolution, processing is environmentally friendly and economically efficient. We predict that in the next few years, 3D printing will replace most PDMS and plastic molding techniques in academia.
Micromachines | 2011
Anthony K. Au; Hoyin Lai; Ben R. Utela; Albert Folch
This review presents an extensive overview of a large number of microvalve and micropump designs with great variability in performance and operation. The performance of a given design varies greatly depending on the particular assembly procedure and there is no standardized performance test against which all microvalves and micropumps can be compared. We present the designs with a historical perspective and provide insight into their advantages and limitations for biomedical uses.
Scientific Reports | 2015
Wonjae Lee; Donghoon Kwon; Woong Choi; Gyoo Yeol Jung; Anthony K. Au; Albert Folch; Sangmin Jeon
A facile method has been developed to detect pathogenic bacteria using magnetic nanoparticle clusters (MNCs) and a 3D-printed helical microchannel. Antibody-functionalized MNCs were used to capture E. coli (EC) bacteria in milk, and the free MNCs and MNC-EC complexes were separated from the milk using a permanent magnet. The free MNCs and MNC-EC complexes were dispersed in a buffer solution, then the solution was injected into a helical microchannel device with or without a sheath flow. The MNC-EC complexes were separated from the free MNCs via the Dean drag force and lift force, and the separation was facilitated in the presence of a sheath flow. The concentration of the E. coli bacteria was determined using a light absorption spectrometer, and the limit of detection was found to be 10 cfu/mL in buffer solution and 100 cfu/mL in milk.
Lab on a Chip | 2015
Anthony K. Au; Nirveek Bhattacharjee; Lisa F. Horowitz; Tim C. Chang; Albert Folch
Microfluidic automation - the automated routing, dispensing, mixing, and/or separation of fluids through microchannels - generally remains a slowly-spreading technology because device fabrication requires sophisticated facilities and the technologys use demands expert operators. Integrating microfluidic automation in devices has involved specialized multi-layering and bonding approaches. Stereolithography is an assembly-free, 3D-printing technique that is emerging as an efficient alternative for rapid prototyping of biomedical devices. Here we describe fluidic valves and pumps that can be stereolithographically printed in optically-clear, biocompatible plastic and integrated within microfluidic devices at low cost. User-friendly fluid automation devices can be printed and used by non-engineers as replacement for costly robotic pipettors or tedious manual pipetting. Engineers can manipulate the designs as digital modules into new devices of expanded functionality. Printing these devices only requires the digital file and electronic access to a printer.
Analytical Chemistry | 2014
Wonjae Lee; Donghoon Kwon; Boram Chung; Gyoo Yeol Jung; Anthony K. Au; Albert Folch; Sangmin Jeon
We developed a novel 3D immunomagnetic flow assay for the rapid detection of pathogenic bacteria in a large-volume food sample. Antibody-functionalized magnetic nanoparticle clusters (AbMNCs) were magnetically immobilized on the surfaces of a 3D-printed cylindrical microchannel. The injection of a Salmonella-spiked sample solution into the microchannel produced instant binding between the AbMNCs and the Salmonella bacteria due to their efficient collisions. Nearly perfect capture of the AbMNCs and AbMNCs-Salmonella complexes was achieved under a high flow rate by stacking permanent magnets with spacers inside the cylindrical separator to maximize the magnetic force. The concentration of the bacteria in solution was determined using ATP luminescence measurements. The detection limit was better than 10 cfu/mL, and the overall assay time, including the binding, rinsing, and detection steps for a 10 mL sample took less than 3 min. To our knowledge, the 3D immunomagnetic flow assay described here provides the fastest high-sensitivity, high-capacity method for the detection of pathogenic bacteria.
Lab on a Chip | 2013
Adina Scott; Anthony K. Au; Elise Vinckenbosch; Albert Folch
Standardized, affordable, user-friendly world-to-chip interfaces represent one of the major barriers to the adoption of microfluidics. We present a connector system for plug-and-play interfacing of microfluidic devices to multiple input and output lines. The male connectors are based on existing standardized housings from electronics that are inexpensive and widely available. The female connectors are fabricated using familiar replica molding techniques that can easily be adopted by microfluidic developers.
Scientific Reports | 2018
Tarek Kaddoura; Anthony K. Au; Greg Kawchuk; Richard R. E. Uwiera; Richard C. Fox; Roger J. Zemp
Ultrafast ultrasound imaging is used to capture driven spinal vibrations as a new method for non-invasive spinal testing in living subjects. Previously, it has been shown that accelerometer-based vibration testing in cadaveric models can reveal the presence, location and magnitude of spinal pathology. However, this process remains an invasive procedure as current non-invasive sensors are inadequate. In this paper, the ability of non-invasive ultrafast ultrasound to quantify in vivo vertebral vibration response across a broad range of frequencies (10–100Hz) in anesthetized pig models is investigated. Close agreement with invasive accelerometer measurements is achieved using the non-invasive ultrasound method, opening up unique opportunities to investigate spinal pathologies.
Lab on a Chip | 2014
Anthony K. Au; Wonjae Lee; Albert Folch
Lab on a Chip - Miniaturisation for Chemistry and Biology | 2014
Anthony K. Au; Wonjae Lee; Albert Folch
Angewandte Chemie | 2016
Anthony K. Au; Wilson Huynh; Lisa F. Horowitz; Albert Folch