Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Antonino Guerrisi is active.

Publication


Featured researches published by Antonino Guerrisi.


Radiology | 2010

Intraindividual Comparison of Gadoxetate Disodium–enhanced MR Imaging and 64-Section Multidetector CT in the Detection of Hepatocellular Carcinoma in Patients with Cirrhosis

Michele Di Martino; Daniele Marin; Antonino Guerrisi; Mahbubeh Baski; Francesca Galati; M. Rossi; Stefania Brozzetti; Raffaele Masciangelo; Roberto Passariello; Carlo Catalano

PURPOSE To prospectively compare gadoxetate disodium-enhanced magnetic resonance (MR) imaging with multiphasic 64-section multidetector computed tomography (CT) in the detection of hepatocellular carcinoma (HCC) in patients with cirrhosis. MATERIALS AND METHODS Institutional review board approval and informed patient consent were obtained for this prospective study. Fifty-eight patients (39 men, 19 women; mean age, 63 years; age range, 35-84 years) underwent gadoxetate disodium-enhanced MR imaging and multiphasic 64-section multidetector CT. The imaging examinations were performed within 30 days of each other. The two sets of images were qualitatively analyzed in random order by three independent readers in a blinded and retrospective fashion. Using strict diagnostic criteria for HCC, readers classified all detected lesions with use of a four-point confidence scale. The reference standard was a combination of pathologic proof, conclusive imaging findings, and substantial tumor growth at follow-up CT or MR imaging (range of follow-up, 90-370 days). The diagnostic accuracy, sensitivity, and positive predictive value were compared between the two image sets. Interreader variability was assessed. The accuracy of each imaging method was determined by using an adjusted modified chi(2) test. RESULTS Eighty-seven HCCs (mean size +/- standard deviation, 1.8 cm +/- 1.5; range, 0.3-7.0 cm) were confirmed in 42 of the 58 patients. Regardless of lesion size, the average diagnostic accuracy and sensitivity for all readers were significantly greater with gadoxetate disodium-enhanced MR imaging (average diagnostic accuracy: 0.88, 95% confidence interval [CI]: 0.80, 0.97; average sensitivity: 0.85, 95% CI: 0.74, 0.96) than with multidetector CT (average diagnostic accuracy: 0.74, 95% CI: 0.65, 0.82; average sensitivity: 0.69, 95% CI: 0.59, 0.79) (P < .001 for each). No significant difference in positive predictive value was observed between the two image sets for each reader. Interreader agreement was good to excellent. CONCLUSION Compared with multiphasic 64-section multidetector CT, gadoxetate disodium-enhanced MR imaging yields significantly higher diagnostic accuracy and sensitivity in the detection of HCC in patients with cirrhosis.


Radiology | 2009

Hepatocellular Carcinoma in Patients with Cirrhosis: Qualitative Comparison of Gadobenate Dimeglumine–enhanced MR Imaging and Multiphasic 64-Section CT

Daniele Marin; Michele Di Martino; Antonino Guerrisi; Gianmaria De Filippis; M. Rossi; Stefano Ginanni Corradini; Raffaele Masciangelo; Carlo Catalano; Roberto Passariello

PURPOSE To prospectively investigate whether combined interpretation of dynamic and hepatobiliary phase magnetic resonance (MR) images can improve the accuracy of gadobenate dimeglumine-enhanced MR imaging in the detection of hepatocellular carcinoma (HCC) compared with either dynamic MR or multiphasic multidetector computed tomographic (CT) images alone. MATERIALS AND METHODS Institutional review board approval and informed patient consent were obtained. Fifty-two patients (39 men, 13 women; mean age, 68 years; range, 38-81 years) suspected of having HCC underwent gadobenate dimeglumine-enhanced MR imaging and multiphasic 64-section multidetector CT. Images were qualitatively analyzed independently by three observers in three separate reading sessions. The alternating free-response receiver operating characteristic (AFROC) method was used to analyze the results. Differences in sensitivity and positive predictive values were calculated at a statistical significance of P < .05. RESULTS A total of 67 HCCs were detected in 36 patients. The mean area under the AFROC curve (A(z)) was significantly higher for either the combined interpretation of dynamic and hepatobiliary phase MR images (A(z) = 0.95) or dynamic MR images alone (0.91) than for CT images (0.77) (P = .01 for both comparisons). The mean sensitivity of combined interpretation of MR images (0.72) was significantly higher than those of dynamic MR images alone (0.63) and multidetector CT images (0.61) (P = .008 and .001, respectively). The mean positive predictive value was not significantly different among the three imaging sets. CONCLUSION The combined interpretation of dynamic and hepatobiliary phase MR images improves diagnostic accuracy of gadobenate dimeglumine-enhanced MR imaging for the detection of HCC compared with either dynamic MR or multiphasic multidetector CT images alone.


European Journal of Radiology | 2013

Prospective comparative evaluation of quantitative-elastosonography (Q-elastography) and contrast-enhanced ultrasound for the evaluation of thyroid nodules: Preliminary experience

Vito Cantisani; F. Consorti; Antonino Guerrisi; I. Guerrisi; Paolo Ricci; M. Di Segni; Ester Mancuso; L. Scardella; F. Milazzo; Ferdinando D’Ambrosio; A. Antonaci

PURPOSE To assess the effectiveness of semiquantitative elastosonography (Q-elastography) compared with contrast-enhanced ultrasound (CEUS) in differentiating the nature of thyroid nodules. METHODS AND MATERIALS Forty-eight consecutive patients (35 males, 13 females, range: 34-69 years, mean: 49.4 years), candidate to surgery, previously detected at color-Doppler ultrasound (CDUS), were prospectively examined with elastosonography with dedicated semiquantitative software (Q-Elastography, Toshiba XG) and CEUS (Technos Mylab 70 Gold X, and Toshiba XG) before surgery. CEUS and elastosonography were evaluated by two investigators in consensus. Comparison between the CEUS pattern and elastonographic strain ratio observed and expected frequencies for the diagnoses was evaluated with χ(2) test or with Fisher exact test. RESULTS Fifty-three nodules (19 papillary carcinoma, 32 hyperplasia, and 2 follicular adenoma) in 48 patients were available for analysis. Regarding echogenicity score, sensitivity, specificity, PPV and NPV of conventional US were 81%, 50%, 56%, 77%; according to Q-elastography, sensitivity, specificity, PPV and NPV were 95%, 88%, 97% and 91% respectively; whereas concerning CEUS, sensitivity specificity PPV and NPV were 79%, 91%, 83% and 89% respectively. Both CEUS and Q-elastography were more specific than US (p<0.01), with not statistical significant difference with regard to sensitivity. CONCLUSIONS The results of the present study suggest that Q-elastography is a valuable tool in the characterization of thyroid nodules and it seems to be more sensitive than CEUS.


American Journal of Roentgenology | 2009

Detection of Hepatocellular Carcinoma in Patients with Cirrhosis: Added Value of Coronal Reformations from Isotropic Voxels with 64-MDCT

Daniele Marin; Carlo Catalano; Gianmaria De Filippis; Michele Di Martino; Antonino Guerrisi; M. Rossi; Roberto Passariello

OBJECTIVE The purpose of our study was to prospectively assess the added value of isotropic coronal reformations of the liver when using 64-MDCT for the detection of hepatocellular carcinoma (HCC). SUBJECTS AND METHODS Seventy-one consecutive patients (60 men, 11 women; mean age, 65 years) suspected of having HCC underwent 64-MDCT with coronal reformations. A multiphasic CT protocol that included unenhanced, hepatic arterial, portal venous, and equilibrium phases was performed. Three independent, blinded readers interpreted the transverse scan alone, the coronal scan alone, and the combined transverse and coronal scans for the presence of HCC. Sensitivity, positive predictive value, area under the receiver operating characteristic curve (A(z)), and interpretation time were calculated for each reading session. RESULTS Seventy-six HCC nodules were confirmed in 48 patients using histopathologic analysis or follow-up with long-term CT, MRI, or both (mean follow-up time, 12 months; range, 12-15 months) as the reference standard. Mean sensitivity, positive predictive value, and A(z) value for HCC detection were, respectively, 84% (191/228 readings), 91% (191/210 readings), and 0.85 for the transverse scan alone; 83% (189/228 readings), 93% (189/203 readings), and 0.86 for the coronal scan alone; and 87% (198/228 readings), 93% (198/213 readings), and 0.87 for combined interpretation of transverse and coronal scans. No comparisons were statistically significant. Forty-eight false-positive interpretations were recorded (19 for the transverse, 14 for the coronal, and 15 for the combined interpretation sets). The reading session in which combined transverse and coronal scans were available for interpretation showed significantly superior reader confidence for HCC detection as well as longer interpretation times (p<0.05 for both comparisons). The average reading time for the combined interpretation of transverse and coronal image sets (mean, 12.1+/-0.8 minutes) was significantly longer than for the transverse image set (7.4+/-1.5 minutes) or the coronal image set (7.1+/-1.3 minutes) (p<0.01). CONCLUSION With 64-MDCT, the addition of isotropic coronal reformations to transverse images significantly improved reader confidence for the detection of HCC, with no statistically significant improvement in sensitivity, positive predictive value, or diagnostic accuracy (as determined by the A(z) value). This improvement comes at the cost of a longer interpretation time.


European Journal of Radiology | 2012

Perfusion Computed Tomography (PCT) adopting different perfusion metrics: Recurrence of brain metastasis or radiation necrosis?

Antonello Vidiri; Antonino Guerrisi; Valentina Pinzi; Alessandra Fabi; Maria Alessandra Mirri; Alfredo Pompili; Nicoletta Caporale; Andrea Pace; Marcello Crecco; Simona Marzi

OBJECTIVE Different perfusion metrics were investigated to determine the accuracy of Perfusion CT (PCT) in differentiating recurrence of brain metastases from radiation necrosis in patients who previously underwent stereotactic radiation therapy (SRT). PATIENTS AND METHODS Twenty patients previously treated with SRT underwent PCT examination of the brain. Normalized Cerebral Blood Volume (nCBV) values within the region of interest (ROI) were calculated. Fractional volumes at nCBV values between 1.0 and 2.25, defined as V(1.0)-V(2.25), were derived as alternative metrics and compared to the conventional method based on the mean CBV value within the lesion (nCBV(mean)). The Mann-Whitney test was used to compare the two patients groups with recurrence and radiation necrosis with respect to the different nCBV metrics. Predictive powers and optimal thresholds for both the nCBV(mean) and the V(1.0)-V(2.25) were evaluated using the Receiver Operating Characteristic Curves. The gold standard was represented either by the histopathological examination or the Magnetic Resonance (MR) imaging follow-up longer than six months. RESULTS AND CONCLUSION The differences between the patients group with recurrence and that with radiation necrosis resulted statistically significant for all the metrics, showing the lowest p-value for V(1.75) and V(2). The metrics based on the fractional volumes were found to show higher predictive powers, with the highest value of 0.96 for V(2.0). Quantitative analysis of the CBV map deriving different metrics may potentially improve the diagnostic accuracy of PCT in differentiating brain metastasis recurrence from radiation necrosis.


Journal of Experimental & Clinical Cancer Research | 2014

HF ultrasound vs PET-CT and telethermography in the diagnosis of In-transit metastases from melanoma: a prospective study and review of the literature

Francesco Maria Solivetti; Flora Desiderio; Antonino Guerrisi; Antonio Bonadies; Carlo Ludovico Maini; Simona Di Filippo; Valerio D’Orazi; Isabella Sperduti; Aldo Di Carlo

BackgroundOver the past several years the incidence of cutaneous melanoma has rapidly increased. This tumor develops often in-transit metastases that significantly reduce patient survival at 5 years. To improve prognosis and quality of life in patients with melanoma metastases, a mini invasive procedure like electrochemotherapy (ECT) is adopted to remove superficial tissue lesions. To detect the melanoma metastases, high frequency (HF) ultrasound (US) is used. This technique, though, can be time-consuming and it needs an expert operator and a high performing machine. Therefore, we asked whether the US could be replaced or integrated with other less time-consuming techniques such as 18-FDG positron emission tomography/computed tomography (PET-CT) and telethermography (TT).MethodsFifteen patients (4 males and 11 females - age range: 63–91) affected whit advanced stage melanoma were enrolled. They presented 52 in-transit metastases as detected by the three techniques used, HF-US, PET/CT and TT within 30 days before ECT.ResultsAll the 52 lesions were detected by HF-US (100%), 24/52 were detected by PET-CT (42,6%) and 15/52 were detected by TT (27,7%). PET-CT reported 3.7% false positives, while no false positive were reported by TT.ConclusionsAs US detected 100% lesions, compared to the other two techniques used, US, along with clinical examination, has still to be considered as gold standard in the diagnosis of metastatic lesions. US, associated with an exhaustive anamnesis and accurate clinical examination, cannot be replaced by either PET-CT or TT. When US performing devices and experienced operators are not available, though, it is highly recommended to integrate US with at least one of the other techniques. Under certain circumstances, as in the case of obese and non-collaborating patients or in patients with lymphatic stasis, these techniques should be integrated to obtain exact in-transit metastases evaluation.


Journal of Medical Case Reports | 2013

Congenital asymptomatic diaphragmatic hernias in adults: a case series.

Enrica Bianchi; Paola Mancini; Stefania De Vito; Elena Pompili; Samanta Taurone; Isabella Guerrisi; Antonino Guerrisi; Vito D’Andrea; Vito Cantisani; Marco Artico

IntroductionCongenital diaphragmatic hernia is a major malformation occasionally found in newborns and babies. Congenital diaphragmatic hernia is defined by the presence of an orifice in the diaphragm, more often to the left and posterolateral, that permits the herniation of abdominal contents into the thorax. The aim of this case series is to provide information on the presentation, diagnosis and outcome of three patients with late-presenting congenital diaphragmatic hernias. The diagnosis of congenital diaphragmatic hernia is based on clinical investigation and is confirmed by plain X-ray films and computed tomography scans.Case presentationsIn the present report three cases of asymptomatic abdominal viscera herniation within the thorax are described. The first case concerns herniation of some loops of the large intestine into the left hemi-thorax in a 75-year-old Caucasian Italian woman. The second case concerns a rare type of herniation in the right side of the thorax of the right kidney with a part of the liver parenchyma in a 57-year-old Caucasian Italian woman. The third case concerns herniation of the stomach and bowel into the left side of the chest with compression of the left lung in a 32-year-old Caucasian Italian man. This type of hernia may appear later in life, because of concomitant respiratory or gastrointestinal disease, or it may be an incidental finding in asymptomatic adults, such as in the three cases featured here.ConclusionsPatients who present with late diaphragmatic hernias complain of a wide variety of symptoms, and diagnosis may be difficult. Additional investigation and research appear necessary to better explain the development and progression of this type of disease.


Journal of Magnetic Resonance Imaging | 2008

Gadobenate dimeglumine-enhanced magnetic resonance imaging of primary leiomyoma of the liver

Daniele Marin; Carlo Catalano; M. Rossi; Antonino Guerrisi; Michele Di Martino; Pasquale Berloco; Roberto Passariello

We report a case of histologically proven primary leiomyoma of the liver that was evaluated with multiphasic 64‐section computed tomography (CT) and gadobenate dimeglumine–enhanced magnetic resonance (MR) imaging. This lesion showed vivid enhancement during the arterial phase with sustained enhancement during the hepatic venous and equilibrium phases. During the liver‐specific MR imaging phase (150 minutes after contrast injection), the same lesion demonstrated lack of contrast retention, thus appearing hypointense compared with the background liver. Because of this latter finding, the patient underwent partial resection of the liver. In primary hepatic leiomyoma, the absence of contrast uptake during the liver‐specific phase of gadobenate dimeglumine–enhanced MR imaging may be inappropriately interpreted as a sign of malignancy, thus leading to unnecessary, aggressive management of such lesions. J. Magn. Reson. Imaging 2008;28:755–758.


Radiology and Oncology | 2014

The role of ultrasound and ultrasound-guided fine needle aspiration biopsy of lymph nodes in patients with skin tumours

Francesco Maria Solivetti; Fulvia Elia; Maria Giulia Santaguida; Antonino Guerrisi; Paolo Visca; Maria Cecilia Cercato; Aldo Di Carlo

Abstract Background. The primary aim of this study was to evaluate the diagnostic accuracy of ultrasound (US) in the study of superficial lymph nodes during the follow-up of patients surgically treated for skin tumours. The secondary objective was to compare positive cytological results with histological reports. Patients and methods. From 2004 to 2011, 480 patients (male/female: 285/195; median age 57 years; prevalent skin tumour: melanoma) underwent US-guided fine-needle aspiration biopsy (FNAB) of suspicious recurrent lymph nodes. An expert radiologist first performed US testing of the lymph nodes, expressing either a negative or positive outcome of the test. Subsequently, US-guided FNAB was performed. FNAB positive patients were subjected to lymphadenectomy; the patients who tested negative underwent the follow-up. Results. The size of lymph nodes was ≤ 2 cm in 90% of cases. Out of the 336 (70%) US “positive” patients, 231 (68.8%) were FNAB positives. Out of the 144 (30%) US “negatives”, 132 (91.7%) were FNAB negatives. The sensitivity and specificity of the US were 95% and 55.7%, respectively; the negative predictive value was 91.7% and the positive predictive value was 68.8%. Definitive histological results confirmed FNAB positivity in 97.5% of lymphadenectomies. Conclusions. US is a sensitive method in the evaluation of superficial lymph nodes during the follow-up of patients with skin tumours. High positive predictive value of cytology was confirmed.


British Journal of Radiology | 2011

Effect of varying contrast material iodine concentration and injection technique on the conspicuity of hepatocellular carcinoma during 64-section MDCT of patients with cirrhosis

Antonino Guerrisi; Daniele Marin; Rendon C. Nelson; G. De Filippis; M. Di Martino; Huiman X. Barnhart; Raffaele Masciangelo; I. Guerrisi; Roberto Passariello; Carlo Catalano

OBJECTIVES The aim of this study was to compare the intraindividual effects of contrast material with two different iodine concentrations on the conspicuity of hepatocellular carcinoma (HCC) and vascular and hepatic contrast enhancement during multiphasic, 64-section multidetector row CT (MDCT) in patients with cirrhosis using two contrast medium injection techniques. METHODS Patients were randomly assigned to one of two groups with an equal iodine dose but different contrast material injection techniques: scheme A, fixed injection duration (25 s), and scheme B, fixed injection flow rate (4 ml s(-1)). For each group, patients were randomised to receive both moderate-concentration contrast medium (MCCM) and high-concentration contrast medium (HCCM) during two CT examinations within 3 months. Enhancement of the aorta, liver and portal vein and the tumour-to-liver contrast-to-noise ratio (CNR) were compared between MCCM and HCCM. RESULTS 30 patients (mean age 59 years; range 45-80 years; 16 patients in scheme A and 14 in scheme B) with a total of 31 confirmed HCC nodules were prospectively enrolled. For scheme B, the mean contrast enhancement of the aorta and tumour-to-liver CNR were significantly higher with HCCM than with MCCM during the hepatic arterial phase (+350.5 HU vs +301.1 HU, p = 0.001, and +7.5 HU vs +5.5 HU, p = 0.004). For both groups, there was no significant difference between MCCM and HCCM for all other comparisons. CONCLUSION For a constant injection flow rate, HCCM significantly improves the conspicuity of HCC lesions and aortic enhancement during the hepatic arterial phase on 64-section MDCT in patients with cirrhosis.

Collaboration


Dive into the Antonino Guerrisi's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Carlo Catalano

Sapienza University of Rome

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Antonello Vidiri

Sapienza University of Rome

View shared research outputs
Top Co-Authors

Avatar

Francesco Maria Solivetti

Catholic University of the Sacred Heart

View shared research outputs
Top Co-Authors

Avatar

M. Rossi

Sapienza University of Rome

View shared research outputs
Top Co-Authors

Avatar

Michele Di Martino

Sapienza University of Rome

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Giuseppe Spriano

Ospedale di Circolo e Fondazione Macchi

View shared research outputs
Researchain Logo
Decentralizing Knowledge