Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Arisa Imai is active.

Publication


Featured researches published by Arisa Imai.


Journal of Dentistry | 2016

Influence of Degradation Conditions on Dentin Bonding Durability of Three Universal Adhesives

Keiichi Sai; Yutaka Shimamura; Toshiki Takamizawa; Akimasa Tsujimoto; Arisa Imai; Hajime Endo; Wayne W. Barkmeier; Mark A. Latta; Masashi Miyazaki

OBJECTIVES This study aims to determine dentin bonding durability of universal adhesives using shear bond strength (SBS) tests under various degradation conditions. METHODS G-Premio Bond (GP, GC), Scotchbond Universal (SU, 3M ESPE) and All Bond Universal (AB, Bisco) were compared with conventional two-step self-etch adhesive Clearfil SE Bond (SE, Kuraray Noritake Dental). Bonded specimens were divided into three groups of ten, and SBSs with bovine dentin were determined after the following treatments: 1) Storage in distilled water at 37°C for 24h followed by 3000, 10,000, 20,000 or 30,000 thermal cycles (TC group), 2) Storage in distilled water at 37°C for 3 months, 6 months or 1year (water storage, WS group) and 3) Storage in distilled water at 37°C for 24h (control). RESULTS SE bonded specimens showed significantly higher SBSs than universal adhesives, regardless of TC or storage periods, although AB specimens showed significantly increased SBSs after 30,000 thermal cycles. In comparisons of universal adhesives under control and degradation conditions, SBS was only reduced in SU after 1year of WS. CONCLUSION Following exposure of various adhesive systems to degradation conditions of thermal cycling and long term storage, SBS values of adhesive systems varied primarily with degradation period. CLINICAL SIGNIFICANCE Although universal adhesives have lower SBSs than the two-step self-etch adhesive SE, the present data indicate that the dentin bonding durability of universal adhesives in self-etch mode is sufficient for clinical use.


European Journal of Oral Sciences | 2017

Influence of application method on surface free-energy and bond strength of universal adhesive systems to enamel

Arisa Imai; Toshiki Takamizawa; Keiichi Sai; Akimasa Tsujimoto; Kie Nojiri; Hajime Endo; Wayne W. Barkmeier; Mark A. Latta; Masashi Miyazaki

The aim of the present study was to determine the influence of different adhesive application methods and etching modes on enamel bond effectiveness of universal adhesives using shear bond strength (SBS) testing and surface free-energy (SFE) measurements. The adhesives Scotchbond Universal, All-Bond Universal, Adhese Universal, and G-Premio Bond were used. Prepared bovine enamel specimens were divided into four groups, based on type of adhesive, and subjected to the following surface treatments: (i) total-etch mode with active application; (ii) total-etch mode with inactive application; (iii) self-etch mode with active application; and (iv) self-etch mode with inactive application. Bonded specimens were subjected to SBS testing. The SFE of the enamel surfaces with adhesive was measured after rinsing with acetone and water. The SBS values in total-etch mode were significantly higher than those in self-etch mode. In total-etch mode, significantly lower SBS values were observed with active application compared with inactive application; in contrast, in self-etch mode there were no significant differences in SBS between active and inactive applications. A reduction in total SFE was observed for active application compared with inactive application. The interaction between etching mode and application method was statistically significant, and the application method significantly affected enamel bond strength in total-etch mode.


Dental Materials | 2017

Influence of different smear layers on bond durability of self-etch adhesives

Toshiki Takamizawa; Wayne W. Barkmeier; Keiichi Sai; Akimasa Tsujimoto; Arisa Imai; Robert L. Erickson; Mark A. Latta; Masashi Miyazaki

OBJECTIVE The purpose of this study was to determine the influence of different smear layers on enamel and dentin bond durability of various types of self-etch adhesives. METHODS Two universal adhesives, Scotchbond Universal (SU) and Prime & Bond elect (PE); a conventional single-step self-etch adhesive, G-ænial Bond (GB); and two two-step self-etch adhesives, Optibond XTR (OX) and Clearfil SE Bond (SE) were used in this study. Shear bond strengths (SBS) and shear fatigue strengths (SFS) to human enamel and dentin were determined with different smear layer conditions. The prepared specimens were divided into three groups. The bonding surfaces were prepared by grinding with either (1) #180, (2) #600, or (3) #4000-SiC papers before making the bonded assemblies. For each group, 15 specimens were prepared for the SBS and 30 specimens for the SFS. RESULTS The two-step self-etch adhesives showed significantly higher SFS values than the single-step self-etch adhesives, regardless of the smear layer condition or substrate. Although most of the tested adhesives showed no significant differences in enamel SFS values among the smear layer groups, SU, GB, and SE showed significantly lower SFS values in the #180 in dentin groups than the #600 and #4000 groups. CONCLUSION The influence of different smear layer conditions on bond durability was adhesive dependent. Furthermore, the smear layers generated on different substrates also influenced the bond quality of the self-etch adhesives. SIGNIFICANCE Smear layer conditions of enamel and dentin influence the bond durability of universal adhesives and conventional single and two-step self-etch adhesives.


Journal of The Mechanical Behavior of Biomedical Materials | 2019

Interrelation among the handling, mechanical, and wear properties of the newly developed flowable resin composites

Arisa Imai; Toshiki Takamizawa; Runa Sugimura; Akimasa Tsujimoto; Ryo Ishii; Mami Kawazu; Tatsuro Saito; Masashi Miyazaki

OBJECTIVES This study investigates the handling, mechanical, and wear properties of the newly developed flowable resin composites and elucidate the interrelations among the tested parameters. METHODS Six flowable and two conventional resin composites are used. Five measurements are performed per resin composite to obtain the average inorganic filler content. Ten specimens per material are used to obtain the flexural strength, flexural modulus, and resilience. For sliding impact wear testing, twelve specimens are prepared. Noncontact profilometer and confocal laser scanning microscopy are used to determine the maximum facet depth and volume loss. Extrusion force and thread formation are used to measure the handling properties of the flowable resin composites. Six measurements are performed per flowable resin composite. Data evaluation is performed using analysis of variance and Tukeys honestly significant difference test at an α-level of 0.05. The correlation between the tested parameters is verified using the Pearson product-moment correlation coefficient. RESULTS A subset of flowable resin composites exhibits higher flexural properties and wear resistance as compared to the conventional resin composites. The handling properties of the flowable resin composites are material dependent. CONCLUSION While the resilience parameters exhibit an extremely strong and statistically significant correlation with the wear parameters, the handling properties exhibit no interrelation with the remaining parameters. SIGNIFICANCE While the handling properties of the newly developed flowable resin composites did not correlate with the mechanical and wear properties, some new flowable resin composites have the potential for use in high-stress bearing areas, such as posterior lesions, because of the enhanced mechanical properties and wear resistance.


Journal of The Mechanical Behavior of Biomedical Materials | 2018

Effect of double-layer application on bond quality of adhesive systems

Toshiki Takamizawa; Wayne W. Barkmeier; Akimasa Tsujimoto; Arisa Imai; Hidehiko Watanabe; Robert L. Erickson; Mark A. Latta; Toshiyuki Nakatsuka; Masashi Miyazaki

OBJECTIVES The aim of this study was to determine the effect of double-layer application of universal adhesives on the bond quality and compare to other adhesive systems. METHODS Two universal adhesives used were in this study: Scotchbond Universal (SU), [3M ESPE] and Prime & Bond elect (PE), [Dentsply Caulk]. The conventional single-step self-etch adhesives G-ӕnial Bond (GB), [GC Corporation.] and BeautiBond (BB), [Shofu Inc.], and a two-step self-etch adhesive, Optibond XTR (OX), [Kerr Corporation], were used as comparison adhesives. Shear bond strengths (SBS) and shear fatigue strengths (SFS) to human enamel and dentin were measured in single application mode and double application mode. For each test condition, 15 specimens were prepared for SBS testing and 30 specimens for SFS testing. RESULTS Enamel and dentin SBS of the universal adhesives in the double application mode were significantly higher than those of the single application mode. In addition, the universal adhesives in the double application mode had significantly higher dentin SFS values than those of the single application mode. The two-step self-etch adhesive OX tended to have lower bond strengths in the double application mode, regardless of the test method or adherent substrate. CONCLUSION The double application mode is effective in enhancing SBS and SFS of universal adhesives, but not conventional two-step self-etch adhesives. SIGNIFICANCE These results suggest that, although the double application mode may enhance the bonding quality of a universal adhesive, it may be counter-productive for two-step self-etch adhesives in clinical use.


Journal of Adhesive Dentistry | 2018

Influence of application time and etching mode of universal adhesives on enamel adhesion

Keiichi Sai; Toshiki Takamizawa; Arisa Imai; Akimasa Tsujimoto; Ryo Ishii; Wayne W. Barkmeier; Mark A. Latta; Masashi Miyazaki

PURPOSE To investigate the influence of application time and etching mode of universal adhesives on enamel adhesion. MATERIALS AND METHODS Five universal adhesives, Adhese Universal, Bondmer Lightless, Clearfil Universal Bond Quick, G-Premio Bond, and Scotchbond Universal, were used. Bovine incisors were prepared and divided into four groups of ten teeth each. SBS, Ra, and SFE were determined after the following procedures: 1. self-etch mode with immediate air blowing after application (IA); 2. self-etch mode with prolonged application time (PA); 3. etch-and-rinse mode with IA; 4. etch-and-rinse mode with PA. After 24-h water storage, the bonded assemblies were subjected to shear bond strength (SBS) tests. For surface roughness (Ra) and surface free energy (SFE) measurements, the adhesives were simply applied to the enamel and rinsed with acetone and water before the measurements were carried out. RESULTS Significantly higher SBS and Ra values were obtained with etch-and-rinse mode than with self-etch mode regardless of the application time or type of adhesive. Although most adhesives showed decreased SFE values with increased application time in self-etch mode, SFE values in etch-and-rinse mode were dependent on the adhesive type and application time. CONCLUSIONS Etching mode, application time, and type of adhesive significantly influenced the SBS, Ra, and SFE values.


Operative Dentistry | 2017

Polymerization Behavior and Mechanical Properties of High-Viscosity Bulk Fill and Low Shrinkage Resin Composites

Syo Shibasaki; Toshiki Takamizawa; Kie Nojiri; Arisa Imai; Akimasa Tsujimoto; Hajime Endo; Soshi Suzuki; Shunichi Suda; Wayne W. Barkmeier; Mark A. Latta; Masashi Miyazaki

The present study determined the mechanical properties and volumetric polymerization shrinkage of different categories of resin composite. Three high viscosity bulk fill resin composites were tested: Tetric EvoCeram Bulk Fill (TB, Ivoclar Vivadent), Filtek Bulk Fill posterior restorative (FB, 3M ESPE), and Sonic Fill (SF, Kerr Corp). Two low-shrinkage resin composites, Kalore (KL, GC Corp) and Filtek LS Posterior (LS, 3M ESPE), were used. Three conventional resin composites, Herculite Ultra (HU, Kerr Corp), Estelite ∑ Quick (EQ, Tokuyama Dental), and Filtek Supreme Ultra (SU, 3M ESPE), were used as comparison materials. Following ISO Specification 4049, six specimens for each resin composite were used to determine flexural strength, elastic modulus, and resilience. Volumetric polymerization shrinkage was determined using a water-filled dilatometer. Data were evaluated using analysis of variance followed by Tukeys honestly significant difference test (α=0.05). The flexural strength of the resin composites ranged from 115.4 to 148.1 MPa, the elastic modulus ranged from 5.6 to 13.4 GPa, and the resilience ranged from 0.70 to 1.0 MJ/m3. There were significant differences in flexural properties between the materials but no clear outliers. Volumetric changes as a function of time over a duration of 180 seconds depended on the type of resin composite. However, for all the resin composites, apart from LS, volumetric shrinkage began soon after the start of light irradiation, and a rapid decrease in volume during light irradiation followed by a slower decrease was observed. The low shrinkage resin composites KL and LS showed significantly lower volumetric shrinkage than the other tested materials at the measuring point of 180 seconds. In contrast, the three bulk fill resin composites showed higher volumetric change than the other resin composites. The findings from this study provide clinicians with valuable information regarding the mechanical properties and polymerization kinetics of these categories of current resin composite.


Dental Materials Journal | 2017

Ultrasonic monitoring of the setting of silicone elastomeric impression materials

Chie Kanazawa; Ryosuke Murayama; Tetsuya Furuichi; Arisa Imai; Shunichi Suda; Hiroyasu Kurokawa; Toshiki Takamizawa; Masashi Miyazaki

This study used an ultrasonic measurement device to monitor the setting behavior of silicone elastomeric impression materials, and the influence of temperature on setting behavior was determined. The ultrasonic device consisted of a pulser-receiver, transducers, and an oscilloscope. The two-way transit time through the mixing material was divided by two to account for the down-and-back travel path; then it was multiplied by the sonic velocity. Analysis of variance and the Tukey honest significant difference test were used. In the early stages of the setting process, most of the ultrasonic energy was absorbed by the elastomers and the second echoes were relatively weak. As the elastomers hardened, the sonic velocities increased until they plateaued. The changes in sonic velocities varied among the elastomers tested, and were affected by temperature conditions. The ultrasonic method used in this study has considerable potential for determining the setting processes of elastomeric impression materials.


Dental Materials Journal | 2017

Influence of air-powder polishing on bond strength and surface-free energy of universal adhesive systems

Yukie Tamura; Toshiki Takamizawa; Yutaka Shimamura; Shunsuke Akiba; Chiaki Yabuki; Arisa Imai; Akimasa Tsujimoto; Hiroyasu Kurokawa; Masashi Miyazaki

The influences of air-powder polishing with glycine or sodium bicarbonate powders on shear bond strengths (SBS) and surface-free energies of universal adhesives were examined. Scotchbond Universal Adhesive (SU, 3M ESPE), G-Premio Bond (GP, GC), Adhese Universal (AU, Ivoclar Vivadent), and All-Bond Universal (AB, Bisco) were used in this study. Bovine dentin surfaces were air polished with glycine or sodium bicarbonate powders prior to the bonding procedure, and resin pastes were bonded to the dentin surface using universal adhesives. SBSs were determined after 24-h storage in distilled water at 37°C. Surface-free energy was then determined by measuring contact angles using three test liquids on dentin surfaces. Significantly lower SBSs were observed for dentin that was air-powder polished and surface-free energies were concomitantly lowered. This study indicated that air-powder polishing influences SBSs and surface-free energies. However, glycine powder produced smaller changes in these surface parameters than sodium bicarbonate.


Clinical Oral Investigations | 2018

Bond durability of universal adhesive to bovine enamel using self-etch mode

Soshi Suzuki; Toshiki Takamizawa; Arisa Imai; Akimasa Tsujimoto; Keiichi Sai; Masayuki Takimoto; Wayne W. Barkmeier; Mark A. Latta; Masashi Miyazaki

Collaboration


Dive into the Arisa Imai's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge