Arturo Moleti
University of Rome Tor Vergata
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Arturo Moleti.
Journal of the Acoustical Society of America | 2002
M. Lucertini; Arturo Moleti; Renata Sisto
Theoretical considerations and experimental evidence suggest that otoacoustic emission parameters may be used to reveal early cochlear damage, even before it can be diagnosed by standard audiometric techniques. In this work, the statistical distributions of a set of otoacoustic emission parameters chosen as candidates for the early detection of cochlear damage (global and band reproducibility, response level, signal-to-noise ratio, spectral latency, and long-lasting otoacoustic emission presence) were analyzed in a population of 138 ears. These ears have been divided, according to a standard audiometric test, in three classes: (1) ears of nonexposed bilaterally normal subjects, (2) normal ears of subjects with unilateral noise-induced high-frequency hearing loss, and (3) their hearing impaired ears. For all analyzed parameters, a statistically significant difference was found between classes 1 and 2. This difference largely exceeds the difference observed between classes 2 and 3. This fact suggests that the noise exposure, which was responsible for the unilateral hearing loss, also caused subclinical damage in the contralateral, audiometrically normal, ear. This is a clear indication that otoacoustic emission techniques may be able to early detect subclinical damages.
Journal of the Acoustical Society of America | 2007
Renata Sisto; Arturo Moleti
Cochlear latency has been evaluated in young adults by time-frequency analysis of transient evoked otoacoustic emissions recorded using the nonlinear acquisition mode at different levels of the click stimulus. Objective, even if model-dependent, estimates of cochlear tuning have been obtained from the otoacoustic latency estimates. Transmission-line cochlear models predict that the transient-evoked otoacoustic emission latency is dependent on the stimulus level, because the bandwidth of the cochlear filter (tuning) depends on the local cochlear excitation level due to nonlinear damping. The results of this study confirm the increase of tuning with increasing frequency and show clearly the decrease of latency and tuning with increasing stimulus level. This decrease is consistent with the expected relation between the slowing down of the traveling wave near the tonotopic place and the cochlear excitation amplitude predicted by cochlear models including nonlinear damping. More specifically, these results support the models in which nonlinear damping consists of a quadratic term and a constant positive term.
Journal of the Acoustical Society of America | 2002
Renata Sisto; Arturo Moleti
Experimental measurements of the otoacoustic emission (OAE) latency of adult subjects have been obtained, as a function of frequency, by means of wavelet time-frequency analysis based on the iterative application of filter banks. The results are in agreement with previous OAE latency measurements by Tognola et al. [Hear. Res. 106, 112-122 (1997)], as regards both the latency values and the frequency dependence, and seem to be incompatible with the steep 1/f law that is predicted by scale-invariant full cochlear models. The latency-frequency relationship has been best fitted to a linear function of the cochlear physical distance, using the Greenwood map, and to an exponential function of the cochlear distance, for comparison with derived band ABR latency measurements. Two sets of ears [94 audiometrically normal and 42 impaired with high-frequency (f > 3 kHz) hearing loss] have been separately analyzed. Significantly larger average latencies were found in the impaired ears in the mid-frequency range. Theoretical implications of these findings on the transmission of the traveling wave are discussed.
Journal of the Acoustical Society of America | 2003
Arturo Moleti; Renata Sisto
A new method is presented for estimating cochlear tuning starting from measurements of either the transient evoked otoacoustic emission latency or the spontaneous otoacoustic emission minimal spacing. This method could be useful in obtaining indirect information about the tuning curve, particularly for subjects that, like neonates, cannot be studied with psycho-acoustical techniques. Theoretical models of the acoustic transmission along the cochlea based on the transmission line formalism predict a relation between the otoacoustic emission latency and the frequency. This relation depends on the tuning curve, i.e., the frequency dependence of the quality factor of the cochlear resonances. On the other hand, models for the generation of spontaneous emissions based on the concept of coherent scattering from cochlear random inhomogeneities imply an independent relation between the tuning curve and the minimal frequency spacing between spontaneous emissions. In this study, experimental measurements of the otoacoustic emission latency and of the minimal spacing between spontaneous emissions are presented. Theoretical relations are derived, which connect these two measured quantities and the tuning curve. The typically longer latency of neonates implies a higher degree of tuning at high levels of stimulation.
Journal of the Acoustical Society of America | 2012
Arturo Moleti; Federica Longo; Renata Sisto
Time-domain filtering is a standard analysis technique, which is used to disentangle the two main vector components of the distortion product otoacoustic emission response, exploiting their different phase-frequency relation. In this study, a time-frequency filtering technique based on the continuous wavelet transform is proposed to overcome the intrinsic limitations of the time-domain filtering technique and to extend it also to the analysis of stimulus-frequency and transient-evoked otoacoustic emissions. The advantages of the proposed technique are first discussed on a theoretical basis, then practically demonstrated by applying it to the analysis of synthesized and real otoacoustic data. The results show that the time-frequency approach can be empirically optimized to get effective separation of the components of the otoacoustic response associated with either different generation mechanisms or different generation places. Focusing on a single component of the otoacoustic response with a given time-frequency signature may also improve significantly the signal-to-noise ratio, because the random noise contribution tends to be uniformly distributed on the time-frequency plane.
Journal of the Acoustical Society of America | 2001
Renata Sisto; Arturo Moleti; M. Lucertini
The relationship between hearing loss, detected by measuring the audiometric threshold shift, and the presence of long-lasting otoacoustic emissions, has been studied in a population of 66 adult males, by analyzing the cochlear response in the 80 ms following the subministration of a click stimulus. Most long-lasting OAEs are also recognizable as Synchronized Spontaneous OAEs (SSOAEs). The OAE characteristic decay times were evaluated according to the model by Sisto and Moleti [J. Acoust. Soc. Am. 106, 1893 (1999)]. The starting hypothesis, confirmed by the results, is that long decay time and large equilibrium amplitude are both manifestations of the effectiveness of the active feedback mechanism. The prevalence and frequency distribution of long-lasting OAEs, and of their SSOAE subset, have been separately analyzed for normal and impaired ears. No long-lasting OAE was found within the hearing loss frequency range, but several were found in impaired ears outside the hearing loss range, both at lower and higher frequencies. This result suggests that the correlation between the presence of long-lasting OAEs and good cochlear functionality be local in the frequency domain. The monitor of the OAE decay time is proposed as a new possible method for early detecting hearing loss in populations exposed to noise.
Journal of the Acoustical Society of America | 2013
Renata Sisto; Filippo Sanjust; Arturo Moleti
The input/output functions of the different-latency components of human transient-evoked and stimulus-frequency otoacoustic emissions are analyzed, with the goal of relating them to the underlying nonlinear dynamical properties of the basilar membrane response. Several cochlear models predict a cubic nonlinearity that would yield a correspondent compressive response. The otoacoustic response comes from different generation mechanisms, each characterized by a particular relation between local basilar membrane displacement and otoacoustic level. For the same mechanism (e.g., reflection from cochlear roughness), different generation places would imply differently compressive regimes of the local basilar membrane dynamics. Therefore, this kind of study requires disentangling these contributions, using suitable data acquisition and time-frequency analysis techniques. Fortunately, different generation mechanisms/places also imply different phase-gradient delays, knowledge of which can be used to perform this task. In this study, the different-latency otoacoustic components systematically show differently compressive response, consistent with two simple hypotheses: (1) all emissions come from the reflection mechanism and (2) the basilar membrane response is strongly compressive in the resonance region and closer to linear in more basal regions. It is not clear if such a compressive behavior also extends to arbitrarily low stimulus levels.
Journal of the Acoustical Society of America | 2007
Renata Sisto; Silvia Chelotti; Lido Moriconi; Stefania Pellegrini; Angela Citroni; Valeria Monechi; Rosa Gaeta; Iole Pinto; Nicola Stacchini; Arturo Moleti
With the aim of investigating the capability of otoacoustic emission (OAE) in the detection of low levels of noise-induced hearing loss, audiometric and otoacoustic data of young workers (age: 18-35) exposed to different levels of industrial noise have been recorded. These subjects are participating in a long-term longitudinal study, in which audiometric, exposure (both professional and extra-professional), and OAE data (transient evoked and distortion product) will be collected for a period of several years. All measurements have been performed, during routine occupational health surveillance, with a standard clinical apparatus and acquisition procedure, which can be easily used in the occupational safety practice. The first study was focused on the correlation between transient evoked OAE signal-to-noise ratio and distortion product (DPOAE) OAE level and the audiometric threshold, investigating the causes of the rather large intersubject variability of the OAE levels. The data analysis has shown that, if both OAE data and audiometric data are averaged over a sufficiently large bandwidth, the correlation between DPOAE levels and audiometric hearing threshold is sufficient to design OAE-based diagnostic tests with good sensitivity and specificity also in a very mild hearing loss range, between 10 and 20 dB.
Journal of the Acoustical Society of America | 2007
Renata Sisto; Arturo Moleti; Christopher A. Shera
In transmission-line models of cochlear mechanics, predictions about otoacoustic-emission delays depend on the place- or wave-fixed nature of the emission generation mechanism. In this work, transient evoked otoacoustic emissions (TEOAEs), recorded at different stimulus levels in 10 young subjects, were analyzed using wavelet-based time-frequency analysis to determine the latency of each frequency component of the response. The same wave forms were Fourier analyzed to evaluate the phase-gradient delay as a function of frequency. Interpreting the relation between these two characteristic delays using cochlear models shows that most of the TEOAE response can be attributed to place-fixed reflection mechanisms. The causality principle explains observed correlations between fluctuations of the TEOAE amplitude and phase-gradient delay.
Journal of the Acoustical Society of America | 2012
Arturo Moleti; Teresa Botti; Renata Sisto
This study focuses on the theoretical prediction and experimental evaluation of the latency of transient-evoked otoacoustic emissions. Response components with different delay have been identified in several studies. The main generator of the transient response is assumed to be coherent reflection from cochlear roughness near the resonant place. Additional components of different latency can be generated by different mechanisms. Experimental data are re-analyzed in this study to evaluate the dependence of the latency on stimulus level, for each component of the response, showing that previous estimates of the otoacoustic emission latency were affected by systematic errors. The latency of the emission from each generator changes very little with stimulus level, whereas their different growth rate causes sharp changes of the single-valued latency, estimated as the time of the absolute maximum of the bandpass filtered response. Results of passive linear models, in which gain and bandwidth of the cochlear amplifier are strictly related, are incompatible with the observations. Although active linear models including delayed stiffness terms do predict much slower dependence of latency on the stimulus level, a suitable nonlinear model should be designed, capable of decoupling more effectively the dependence on stimulus level of amplitude and phase of the otoacoustic response.