Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Atsuko Tsukamoto is active.

Publication


Featured researches published by Atsuko Tsukamoto.


Japanese Journal of Radiological Technology | 2002

平成22 年度診断用X 線装置アンケート調査報告(撮影条件を中心として)

Yasutaka Nishio; Takatoshi Matsuura; Hiroyuki Miyake; Hiroshi Asano; Yoshio Imai; Atsuko Tsukamoto; Toshinori Ide; Fuminori Shinohara; Shigeru Miyazaki

This is the eighth investigation which has been carried out every 5 years since 1974 for the purpose of grasping the trend of X-ray devices and the radiographic condition. We gathered it up mainly on a radiographic condition, in this report. As for the chest radiography and double contrast gastrography, introduction of the flat panel detector (FPD) advanced in comparison with the last survey. Ratio of the imaging system at chest radiography was 65% for computed radiography (CR), 33% for FPD, 1% for screen/film (S/F), and 1% for others. The radiographic condition of FPD was current time product less than CR. Ratio of the imaging system at gastrography was 3% for CR, 48% for FPD, 34% for image intensifier-digital radiography (I.I.-DR), and 15% for S/F. The tube voltage and the exposure time were similar to the last survey time, but the tube current became lower. Through this survey, the change of the radiographic condition was seen in the radiography part where introduction of the FPD advanced. We think the continuous survey is necessary in future.


Nihon Hōshasen Gijutsu Gakkai zasshi | 2002

[Report based on Fiscal 2000 Diagnostic X-ray Equipment Questionnaire Survey (conditions of X-ray units and similar equipment)].

Mitsuo Ishikawa; Takatoshi Matsuura; Tomoyuki Okuaki; Yoshio Imai; Atsuko Tsukamoto; Toshinori Ide; Fuminori Shinohara; Shigeru Miyazaki

On X-ray diagnostic technology, it is important to grasp a change of the X-ray high-voltage equipment and radiographic technique factors. The 1st questionnaire was performed in 1974, and it carried out after that every five years, and conducted 8th investigation. As a result, we requested 656 institutions and got a reply from 103 institutions. The response rate was 15.7%. For X-ray high-voltage equipment, the inverter-type device shifts to 83.6% from 73.4% of last time. X-ray high-voltage equipment will be shifted to inverter-type device the near future. For X-ray tube device, the target angle becomes more smaller than usual, and maximum anode heat content is increasing tendency. The spread of digital devices is being advanced, and especially the flat panel detector (FPD) increases in the devices. The spread of soft copy diagnoses is 73.8% for chest image diagnoses, and 49.5% for breast image diagnosis. For the device management, the ratio of institutions measured at purchase time was 91.2%. But, the ratio of institutions performed an invariability examination was 58.4%. It is required to grasp the performance of an X-ray equipment and peripheral equipment, and to perform accuracy control in order to obtain proper radiographic technique factors and imaging. In order to use it for the improvement in photography technology, we would like to continue to conduct this investigation periodically.


Japanese Journal of Radiological Technology | 2017

3. Explanation of the DRLs 2015 Published in Japan

Atsuko Tsukamoto


Nihon Hōshasen Gijutsu Gakkai zasshi | 2002

[Characteristics of a new non-invasive x-ray output analyzer].

Fuminori Shinohara; Mitsuo Ishikawa; Shigeru Miyazaki; Toshinori Ide; Hiroshi Asano; Atsuko Tsukamoto; Yoshio Imai; Tomoyuki Okuaki; Masayuki Tanigoshi; Shinji Abe; Izumi Ogura; Toru Negishi


Japanese Journal of Radiological Technology | 1995

267 Computerized database for failure history of X-ray equipments-Preliminary study

Yoshio Imai; Hideo Furubayashi; Osamu Wakamatsu; Atsuko Tsukamoto; Tomoyuki Okuaki; Yoshinari Yanagi; Teruo Ito; Toru Sato; Masatoshi Kobayashi


Japanese Journal of Radiological Technology | 1995

Clinical estimation of 3D-TOF MRA use MTC and Ramped RF

Atsuko Tsukamoto; Midori Yamashita; Yoshio Imai; Tatsuo Fukuchi; Yasunori Yoshizawa; Kouji Hamano; Tomoyuki Okuaki; Masatoshi Kobayashi


Japanese Journal of Radiological Technology | 1995

Percentage average error of tube voltage and X-ray output

Akiko Hayashi; Yoshio Imai; Akira Katono; Atsuko Tsukamoto; Masaru Takahashi; Isao Miyazaki; Takamitsu Hara; Tomoyuki Okuaki; Toshinori Ide; Fumiaki Shinohara; Shigeru Miyazaki


Japanese Journal of Radiological Technology | 1995

Clinical estimation of Fast 3D-TOF MRA use MTC

Atsuko Tsukamoto; Midori Yamashita; Yoshio Imai; Tatsuo Fukuchi; Yasunori Yoshizawa; Kouji Hamano; Tomoyuki Okuaki; Masatoshi Kobayashi


Japanese Journal of Radiological Technology | 1994

191. Multi Slab 3D-TOF MRAngiography of Fast SPGR

Atsuko Tsukamoto; Midori Yamashita; Yoshio Imai; Yasunori Yoshizawa; Tatsuo Fukuchi; Kouji Hamano; Tomoyuki Okuaki; Masatoshi Kobayashi


Japanese Journal of Radiological Technology | 1993

6. Charactoeristics of the Resonance Type Inverter X-ray Generator

Izumi Ogura; Yoh Katoh; Shinji Abe; T. Aoyagi; Atsuko Tsukamoto; M. Kobayashi; K. Matsumoto

Collaboration


Dive into the Atsuko Tsukamoto's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Izumi Ogura

Tokyo Metropolitan University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Akiko Hayashi

Johns Hopkins University

View shared research outputs
Top Co-Authors

Avatar

Toru Negishi

Gunma Prefectural College of Health Sciences

View shared research outputs
Top Co-Authors

Avatar

Yoh Katoh

Tokyo Metropolitan University

View shared research outputs
Researchain Logo
Decentralizing Knowledge