Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Axel Loewe is active.

Publication


Featured researches published by Axel Loewe.


Europace | 2014

Arrhythmic potency of human ether-à-go-go-related gene mutations L532P and N588K in a computational model of human atrial myocytes

Axel Loewe; Mathias Wilhelms; Fathima Fischer; Eberhard P. Scholz; Olaf Dössel; Gunnar Seemann

AIMS Human ether-à-go-go-related gene (hERG) missense mutations N588K and L532P are both associated with atrial fibrillation (AF). However, the underlying gain-of-function mechanism is different. The aim of this computational study is to assess and understand the arrhythmogenic mechanisms of these genetic disorders on the cellular and tissue level as a basis for the improvement of therapeutic strategies. METHODS AND RESULTS The IKr formulation of an established model of human atrial myocytes was adapted by using the measurement data of wild-type and mutant hERG channels. Restitution curves of the action potential duration and its slope, effective refractory period (ERP), conduction velocity, reentry wavelength (WL), and the vulnerable window (VW) were determined in a one-dimensional (1D) tissue strand. Moreover, spiral wave inducibility and rotor lifetime in a 2D tissue patch were evaluated. The two mutations caused an increase in IKr regarding both peak amplitude and current integral, whereas the duration during which IKr is active was decreased. The WL was reduced due to a shorter ERP. Spiral waves could be initiated by using mutation models as opposed to the control case. The frequency dependency of the VW was reversed. CONCLUSION Both mutations showed an increased arrhythmogenicity due to decreased refractory time in combination with a more linear repolarization phase. The effects were more pronounced for mutation L532P than for N588K. Furthermore, spiral waves presented higher stability and a more regular pattern for L532P. These in silico investigations unveiling differences of mutations affecting the same ion channel may help to advance genotype-guided AF prevention and therapy strategies.


Europace | 2014

In-silico assessment of the dynamic effects of amiodarone and dronedarone on human atrial patho-electrophysiology.

Axel Loewe; Yannick Lutz; Mathias Wilhelms; Daniel Sinnecker; Petra Barthel; Eberhard P. Scholz; Olaf Dössel; Georg Schmidt; Gunnar Seemann

AIMS The clinical efficacy in preventing the recurrence of atrial fibrillation (AF) is higher for amiodarone than for dronedarone. Moreover, pharmacotherapy with these drugs is less successful in patients with remodelled substrate induced by chronic AF (cAF) and patients suffering from familial AF. To date, the reasons for these phenomena are only incompletely understood. We analyse the effects of the drugs in a computational model of atrial electrophysiology. METHODS AND RESULTS The Courtemanche-Ramirez-Nattel model was adapted to represent cAF remodelled tissue and hERG mutations N588K and L532P. The pharmacodynamics of amiodarone and dronedarone were investigated with respect to their dose and heart rate dependence by evaluating 10 descriptors of action potential morphology and conduction properties. An arrhythmia score was computed based on a subset of these biomarkers and analysed regarding circadian variation of drug concentration and heart rate. Action potential alternans at high frequencies was observed over the whole dronedarone concentration range at high frequencies, while amiodarone caused alternans only in a narrow range. The total score of dronedarone reached critical values in most of the investigated dynamic scenarios, while amiodarone caused only minor score oscillations. Compared with the other substrates, cAF showed significantly different characteristics resulting in a lower amiodarone but higher dronedarone concentration yielding the lowest score. CONCLUSION Significant differences exist in the frequency and concentration-dependent effects between amiodarone and dronedarone and between different atrial substrates. Our results provide possible explanations for the superior efficacy of amiodarone and may aid in the design of substrate-specific pharmacotherapy for AF.


BioMed Research International | 2015

ECG-Based Detection of Early Myocardial Ischemia in a Computational Model: Impact of Additional Electrodes, Optimal Placement, and a New Feature for ST Deviation

Axel Loewe; Walther H. W. Schulze; Yuan Jiang; Mathias Wilhelms; Armin Luik; Olaf Dössel; Gunnar Seemann

In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2–11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.


Frontiers in Bioengineering and Biotechnology | 2016

Parameter Estimation of Ion Current Formulations Requires Hybrid Optimization Approach to Be Both Accurate and Reliable

Axel Loewe; Mathias Wilhelms; Jochen Schmid; Mathias J. Krause; Fathima Fischer; Dierk Thomas; Eberhard P. Scholz; Olaf Dössel; Gunnar Seemann

Computational models of cardiac electrophysiology provided insights into arrhythmogenesis and paved the way toward tailored therapies in the last years. To fully leverage in silico models in future research, these models need to be adapted to reflect pathologies, genetic alterations, or pharmacological effects, however. A common approach is to leave the structure of established models unaltered and estimate the values of a set of parameters. Today’s high-throughput patch clamp data acquisition methods require robust, unsupervised algorithms that estimate parameters both accurately and reliably. In this work, two classes of optimization approaches are evaluated: gradient-based trust-region-reflective and derivative-free particle swarm algorithms. Using synthetic input data and different ion current formulations from the Courtemanche et al. electrophysiological model of human atrial myocytes, we show that neither of the two schemes alone succeeds to meet all requirements. Sequential combination of the two algorithms did improve the performance to some extent but not satisfactorily. Thus, we propose a novel hybrid approach coupling the two algorithms in each iteration. This hybrid approach yielded very accurate estimates with minimal dependency on the initial guess using synthetic input data for which a ground truth parameter set exists. When applied to measured data, the hybrid approach yielded the best fit, again with minimal variation. Using the proposed algorithm, a single run is sufficient to estimate the parameters. The degree of superiority over the other investigated algorithms in terms of accuracy and robustness depended on the type of current. In contrast to the non-hybrid approaches, the proposed method proved to be optimal for data of arbitrary signal to noise ratio. The hybrid algorithm proposed in this work provides an important tool to integrate experimental data into computational models both accurately and robustly allowing to assess the often non-intuitive consequences of ion channel-level changes on higher levels of integration.


Europace | 2016

Influence of the earliest right atrial activation site and its proximity to interatrial connections on P-wave morphology

Axel Loewe; Martin W. Krueger; Fredrik Holmqvist; Olaf Dössel; Gunnar Seemann; Pyotr G. Platonov

AIMS P-wave morphology correlates with the risk for atrial fibrillation (AF). Left atrial (LA) enlargement could explain both the higher risk for AF and higher P-wave terminal force (PTF) in lead V1. However, PTF-V1 has been shown to correlate poorly with LA size. We hypothesize that PTF-V1 is also affected by the earliest activated site (EAS) in the right atrium and its proximity to inter-atrial connections (IAC), which both show tremendous variability. METHODS AND RESULTS Atrial excitation was triggered from seven different EAS in a cohort of eight anatomically personalized computational models. The posterior IACs were non-conductive in a second set of simulations. Body surface ECGs were computed and separated by left and right atrial contributions. Mid-septal EAS yielded the highest PTF-V1. More anterior/superior and more inferior EAS yielded lower absolute PTF-V1 values deviating by a factor of up to 2.0 for adjacent EAS. Earliest right-to-left activation was conducted via Bachmanns Bundle (BB) for anterior/superior EAS and shifted towards posterior IACs for more inferior EAS. Non-conducting posterior IACs increased PTF-V1 by up to 150% compared to intact posterior IACs for inferior EAS. LA contribution to the P-wave integral was 24% on average. CONCLUSION The electrical contributors site of earliest activation and intactness of posterior IACs affect PTF-V1 significantly by changing LA breakthrough sites independent from LA size. This should be considered for interpretation of electrocardiographical signs of LA abnormality and LA enlargement.


BioMed Research International | 2016

Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage

Tobias Oesterlein; Daniel Frisch; Axel Loewe; Gunnar Seemann; Claus Schmitt; Olaf Dössel; Armin Luik

Whole-chamber mapping using a 64-pole basket catheter (BC) has become a featured approach for the analysis of excitation patterns during atrial fibrillation. A flexible catheter design avoids perforation but may lead to spline bunching and influence coverage. We aim to quantify the catheter deformation and endocardial coverage in clinical situations and study the effect of catheter size and electrode arrangement using an in silico basket model. Atrial coverage and spline separation were evaluated quantitatively in an ensemble of clinical measurements. A computational model of the BC was implemented including an algorithm to adapt its shape to the atrial anatomy. Two clinically relevant mapping positions in each atrium were assessed in both clinical and simulated data. The simulation environment allowed varying both BC size and electrode arrangement. Results showed that interspline distances of more than 20 mm are common, leading to a coverage of less than 50% of the left atrial (LA) surface. In an ideal in silico scenario with variable catheter designs, a maximum coverage of 65% could be reached. As spline bunching and insufficient coverage can hardly be avoided, this has to be taken into account for interpretation of excitation patterns and development of new panoramic mapping techniques.


Current Directions in Biomedical Engineering | 2015

Mesh structure-independent modeling of patient-specific atrial fiber orientation

Andreas Wachter; Axel Loewe; Martin W. Krueger; Olaf Dössel; Gunnar Seemann

Abstract The fiber orientation in the atria has a significant contribution to the electrophysiologic behavior of the heart and to the genesis of arrhythmia. Atrial fiber orientation has a direct effect on excitation propagation, activation patterns and the P-wave. We present a rule-based algorithm that works robustly on different volumetric meshes composed of either isotropic hexahedra or arbitrary tetrahedra as well as on 3-dimensional triangular surface meshes in patient-specific geometric models. This method fosters the understanding of general proarrhythmic mechanisms and enhances patient-specific modeling approaches.


Biomedizinische Technik | 2013

Impact of hERG Mutations on Simulated Human Atrial Action Potentials.

Axel Loewe; Mathias Wilhelms; Fathima Fischer; Eberhard P. Scholz; Olaf Dössel

While human ether-à-go-go-related gene (hERG) mutations N588K and K897T are associated with atrial fibrillation (AF), the underlying arrhythmogenic mechanisms are understood only incompletely. In this work, an approach integrating IKr measurement data from transgenic Xenopus oocytes into established computational models of cardiac electrophysiology is presented. Parameters are estimated using a minimization formulation, which is handled by a hybrid particle swarm optimization (PSO) and trustregion-reflective (TRR) algorithm. Cell models adapted to the mutation measurements show a significantly shorter action potential (AP) with less pronounced spike-and-dome morphology. Results of single cell simulations compare with myocytes in chronic AF.


Computational and Mathematical Methods in Medicine | 2017

Comparison of Baseline Wander Removal Techniques considering the Preservation of ST Changes in the Ischemic ECG: A Simulation Study

Gustavo Lenis; Nicolas Pilia; Axel Loewe; Walther H. W. Schulze; Olaf Dössel

The most important ECG marker for the diagnosis of ischemia or infarction is a change in the ST segment. Baseline wander is a typical artifact that corrupts the recorded ECG and can hinder the correct diagnosis of such diseases. For the purpose of finding the best suited filter for the removal of baseline wander, the ground truth about the ST change prior to the corrupting artifact and the subsequent filtering process is needed. In order to create the desired reference, we used a large simulation study that allowed us to represent the ischemic heart at a multiscale level from the cardiac myocyte to the surface ECG. We also created a realistic model of baseline wander to evaluate five filtering techniques commonly used in literature. In the simulation study, we included a total of 5.5 million signals coming from 765 electrophysiological setups. We found that the best performing method was the wavelet-based baseline cancellation. However, for medical applications, the Butterworth high-pass filter is the better choice because it is computationally cheap and almost as accurate. Even though all methods modify the ST segment up to some extent, they were all proved to be better than leaving baseline wander unfiltered.


computing in cardiology conference | 2015

Methods for analyzing signal characteristics of stable and unstable rotors in a realistic heart model

Markus Rottmann; Laura Unger; Wenzel Kaltenbacher; Gunnar Seemann; Axel Loewe; Martin W. Krueger; Amir S. Jadidi; Thomas Arentz; Olaf Doessel

Atrial fibrillation is a common irregular heart rhythm. Until today there is still a need for research to quantify typical signal characteristics of rotors, which can induce atrial fibrillation. In this work, signal characteristics of a stable and a more unstable rotor in a realistic heart model including fiber orientation were analyzed with the following methods: peak-to-peak amplitude, Hilbert phase, approximate entropy and RS-difference. In this simulation model the stable rotor rotated with a cycle length of 145 ms and stayed in an area of 1.5 mm x 3 mm. Another more unstable rotor with a cycle length of 190 ms moved in an area of 10 mm × 4 mm. In a distance of 2 mm to the rotor tip, the peak-to-peak amplitude decreased significantly, whereas the RS-difference and the approximate entropy were maximal. The rotor center trajectories were detected by phase singularity points determined by the Hilbert transform. We showed that more unstable rotors resulted in more amplitude changes over time and also the cycle length differed more. Furthermore, we presented typical activation time patterns of the Lasso catheter centered at the rotor tip and in different distances to the rotor tip. We suggest that cardiologists use a combination of the described methods to determine a rotor tip position in a more robust manner.

Collaboration


Dive into the Axel Loewe's collaboration.

Top Co-Authors

Avatar

Olaf Dössel

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Tobias Oesterlein

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Gustavo Lenis

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Mathias Wilhelms

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Eberhard P. Scholz

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Nicolas Pilia

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Walther H. W. Schulze

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Martin W. Krueger

Karlsruhe Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge