Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Mathias Wilhelms is active.

Publication


Featured researches published by Mathias Wilhelms.


Europace | 2012

Impact of amiodarone and cisapride on simulated human ventricular electrophysiology and electrocardiograms.

Mathias Wilhelms; Christian Rombach; Eberhard P. Scholz; Olaf Dössel; Gunnar Seemann

AIMS Amiodarone and cisapride are both known to prolong the QT interval, yet the two drugs have different effects on arrhythmia. Cisapride can cause torsades de pointes while amiodarone is found to be anti-arrhythmic. A computational model was used to investigate the action of these two drugs. METHODS AND RESULTS In a biophysically detailed model, the ion current conductivities affected by both drugs were reduced in order to simulate the pharmacological effects in healthy and ischaemic cells. Furthermore, restitution curves of the action potential duration (APD), effective refractory period, conduction velocity, wavelength, and the vulnerable window were determined in a one-dimensional (1D) tissue strand. Moreover, cardiac excitation propagation was computed in a 3D model of healthy ventricles. The corresponding body surface potentials were calculated and standard 12-lead electrocardiograms were derived. Both cisapride and amiodarone caused a prolongation of the QT interval and the refractory period. However, cisapride did not significantly alter the conduction-related properties, such as e.g. the wavelength or vulnerable window, whereas amiodarone had a larger impact on them. It slightly flattened the APD restitution slope and furthermore reduced the conduction velocity and wavelength. CONCLUSION Both drugs show similar prolongation of the QT interval, although they present different electrophysiological properties in the single-cell as well as in tissue simulations of cardiac excitation propagation. These computer simulations help to better understand the underlying mechanisms responsible for the initiation or termination of arrhythmias caused by amiodarone and cisapride.


Europace | 2014

Arrhythmic potency of human ether-à-go-go-related gene mutations L532P and N588K in a computational model of human atrial myocytes

Axel Loewe; Mathias Wilhelms; Fathima Fischer; Eberhard P. Scholz; Olaf Dössel; Gunnar Seemann

AIMS Human ether-à-go-go-related gene (hERG) missense mutations N588K and L532P are both associated with atrial fibrillation (AF). However, the underlying gain-of-function mechanism is different. The aim of this computational study is to assess and understand the arrhythmogenic mechanisms of these genetic disorders on the cellular and tissue level as a basis for the improvement of therapeutic strategies. METHODS AND RESULTS The IKr formulation of an established model of human atrial myocytes was adapted by using the measurement data of wild-type and mutant hERG channels. Restitution curves of the action potential duration and its slope, effective refractory period (ERP), conduction velocity, reentry wavelength (WL), and the vulnerable window (VW) were determined in a one-dimensional (1D) tissue strand. Moreover, spiral wave inducibility and rotor lifetime in a 2D tissue patch were evaluated. The two mutations caused an increase in IKr regarding both peak amplitude and current integral, whereas the duration during which IKr is active was decreased. The WL was reduced due to a shorter ERP. Spiral waves could be initiated by using mutation models as opposed to the control case. The frequency dependency of the VW was reversed. CONCLUSION Both mutations showed an increased arrhythmogenicity due to decreased refractory time in combination with a more linear repolarization phase. The effects were more pronounced for mutation L532P than for N588K. Furthermore, spiral waves presented higher stability and a more regular pattern for L532P. These in silico investigations unveiling differences of mutations affecting the same ion channel may help to advance genotype-guided AF prevention and therapy strategies.


PLOS ONE | 2013

Rotor Termination Is Critically Dependent on Kinetic Properties of I Kur Inhibitors in an In Silico Model of Chronic Atrial Fibrillation

Eberhard P. Scholz; Paola Carrillo-Bustamante; Fathima Fischer; Mathias Wilhelms; Edgar Zitron; Olaf Dössel; Hugo A. Katus; Gunnar Seemann

Inhibition of the atrial ultra-rapid delayed rectifier potassium current (I Kur) represents a promising therapeutic strategy in the therapy of atrial fibrillation. However, experimental and clinical data on the antiarrhythmic efficacy remain controversial. We tested the hypothesis that antiarrhythmic effects of I Kur inhibitors are dependent on kinetic properties of channel blockade. A mathematical description of I Kur blockade was introduced into Courtemanche-Ramirez-Nattel models of normal and remodeled atrial electrophysiology. Effects of five model compounds with different kinetic properties were analyzed. Although a reduction of dominant frequencies could be observed in two dimensional tissue simulations for all compounds, a reduction of spiral wave activity could be only be detected in two cases. We found that an increase of the percent area of refractory tissue due to a prolongation of the wavelength seems to be particularly important. By automatic tracking of spiral tip movement we find that increased refractoriness resulted in rotor extinction caused by an increased spiral-tip meandering. We show that antiarrhythmic effects of I Kur inhibitors are dependent on kinetic properties of blockade. We find that an increase of the percent area of refractory tissue is the underlying mechanism for an increased spiral-tip meandering, resulting in the extinction of re-entrant circuits.


IEEE Transactions on Biomedical Engineering | 2011

In Silico Investigation of Electrically Silent Acute Cardiac Ischemia in the Human Ventricles

Mathias Wilhelms; Olaf Dössel; Gunnar Seemann

Acute cardiac ischemia, which is caused by the occlusion of a coronary artery, often leads to lethal ventricular arrhythmias or heart failure. The early diagnosis of this pathology is based on changes of the electrocardiogram (ECG), i.e., mainly shifts of the ST segment. However, the underlying mechanisms responsible for these shifts are not completely understood. Furthermore, clinical observations indicate that some acute ischemia cases can hardly be detected using standard 12-lead ECG only. Therefore, multiscale computer simulations of cardiac ischemia using realistic models of human ventricles were carried out in this work. For this purpose, the transmembrane voltage distributions in the heart and the corresponding body surface potentials were computed with varying transmural extent of the ischemic region at different ischemia stages. Some of the simulated ischemia cases were “ electrically silent,” i.e., they could hardly be identified in the 12-lead ECG.


Europace | 2014

In-silico assessment of the dynamic effects of amiodarone and dronedarone on human atrial patho-electrophysiology.

Axel Loewe; Yannick Lutz; Mathias Wilhelms; Daniel Sinnecker; Petra Barthel; Eberhard P. Scholz; Olaf Dössel; Georg Schmidt; Gunnar Seemann

AIMS The clinical efficacy in preventing the recurrence of atrial fibrillation (AF) is higher for amiodarone than for dronedarone. Moreover, pharmacotherapy with these drugs is less successful in patients with remodelled substrate induced by chronic AF (cAF) and patients suffering from familial AF. To date, the reasons for these phenomena are only incompletely understood. We analyse the effects of the drugs in a computational model of atrial electrophysiology. METHODS AND RESULTS The Courtemanche-Ramirez-Nattel model was adapted to represent cAF remodelled tissue and hERG mutations N588K and L532P. The pharmacodynamics of amiodarone and dronedarone were investigated with respect to their dose and heart rate dependence by evaluating 10 descriptors of action potential morphology and conduction properties. An arrhythmia score was computed based on a subset of these biomarkers and analysed regarding circadian variation of drug concentration and heart rate. Action potential alternans at high frequencies was observed over the whole dronedarone concentration range at high frequencies, while amiodarone caused alternans only in a narrow range. The total score of dronedarone reached critical values in most of the investigated dynamic scenarios, while amiodarone caused only minor score oscillations. Compared with the other substrates, cAF showed significantly different characteristics resulting in a lower amiodarone but higher dronedarone concentration yielding the lowest score. CONCLUSION Significant differences exist in the frequency and concentration-dependent effects between amiodarone and dronedarone and between different atrial substrates. Our results provide possible explanations for the superior efficacy of amiodarone and may aid in the design of substrate-specific pharmacotherapy for AF.


BioMed Research International | 2015

ECG-Based Detection of Early Myocardial Ischemia in a Computational Model: Impact of Additional Electrodes, Optimal Placement, and a New Feature for ST Deviation

Axel Loewe; Walther H. W. Schulze; Yuan Jiang; Mathias Wilhelms; Armin Luik; Olaf Dössel; Gunnar Seemann

In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2–11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.


IEEE Transactions on Biomedical Engineering | 2014

Characterization of Radiofrequency Ablation Lesion Development Based on Simulated and Measured Intracardiac Electrograms

Matthias Keller; Steffen Schuler; Mathias Wilhelms; Gustavo Lenis; Gunnar Seemann; Claus Schmitt; Olaf Dössel; Armin Luik

Radiofrequency ablation (RFA) therapy is the gold standard in interventional treatment of many cardiac arrhythmias. A major obstacle is nontransmural lesions, leading to recurrence of arrhythmias. Recent clinical studies have suggested intracardiac electrogram (EGM) criteria as a promising marker to evaluate lesion development. Seeking for a deeper understanding of underlying mechanisms, we established a simulation approach for acute RFA lesions. Ablation lesions were modeled by a passive necrotic core surrounded by a borderzone with properties of heated myocardium. Herein, conduction velocity and electrophysiological properties were altered. We simulated EGMs during RFA to study the relation between lesion formation and EGM changes using the bidomain model. Simulations were performed on a three-dimensional setup including a geometrically detailed representation of the catheter with highly conductive electrodes. For validation, EGMs recorded during RFA procedures in five patients were analyzed and compared to simulation results. Clinical data showed major changes in the distal unipolar EGM. During RFA, the negative peak amplitude decreased up to 104% and maximum negative deflection was up to 88% smaller at the end of the ablation sequence. These changes mainly occurred in the first 10 s after ablation onset. Simulated unipolar EGMs reproduced the clinical changes, reaching up to 83% negative peak amplitude reduction and 80% decrease in maximum negative deflection for transmural lesions. In future studies, the established model may enable the development of further EGM criteria for transmural lesions even for complex geometries in order to support clinical therapy.


Frontiers in Bioengineering and Biotechnology | 2016

Parameter Estimation of Ion Current Formulations Requires Hybrid Optimization Approach to Be Both Accurate and Reliable

Axel Loewe; Mathias Wilhelms; Jochen Schmid; Mathias J. Krause; Fathima Fischer; Dierk Thomas; Eberhard P. Scholz; Olaf Dössel; Gunnar Seemann

Computational models of cardiac electrophysiology provided insights into arrhythmogenesis and paved the way toward tailored therapies in the last years. To fully leverage in silico models in future research, these models need to be adapted to reflect pathologies, genetic alterations, or pharmacological effects, however. A common approach is to leave the structure of established models unaltered and estimate the values of a set of parameters. Today’s high-throughput patch clamp data acquisition methods require robust, unsupervised algorithms that estimate parameters both accurately and reliably. In this work, two classes of optimization approaches are evaluated: gradient-based trust-region-reflective and derivative-free particle swarm algorithms. Using synthetic input data and different ion current formulations from the Courtemanche et al. electrophysiological model of human atrial myocytes, we show that neither of the two schemes alone succeeds to meet all requirements. Sequential combination of the two algorithms did improve the performance to some extent but not satisfactorily. Thus, we propose a novel hybrid approach coupling the two algorithms in each iteration. This hybrid approach yielded very accurate estimates with minimal dependency on the initial guess using synthetic input data for which a ground truth parameter set exists. When applied to measured data, the hybrid approach yielded the best fit, again with minimal variation. Using the proposed algorithm, a single run is sufficient to estimate the parameters. The degree of superiority over the other investigated algorithms in terms of accuracy and robustness depended on the type of current. In contrast to the non-hybrid approaches, the proposed method proved to be optimal for data of arbitrary signal to noise ratio. The hybrid algorithm proposed in this work provides an important tool to integrate experimental data into computational models both accurately and robustly allowing to assess the often non-intuitive consequences of ion channel-level changes on higher levels of integration.


Biomedizinische Technik | 2013

Impact of hERG Mutations on Simulated Human Atrial Action Potentials.

Axel Loewe; Mathias Wilhelms; Fathima Fischer; Eberhard P. Scholz; Olaf Dössel

While human ether-à-go-go-related gene (hERG) mutations N588K and K897T are associated with atrial fibrillation (AF), the underlying arrhythmogenic mechanisms are understood only incompletely. In this work, an approach integrating IKr measurement data from transgenic Xenopus oocytes into established computational models of cardiac electrophysiology is presented. Parameters are estimated using a minimization formulation, which is handled by a hybrid particle swarm optimization (PSO) and trustregion-reflective (TRR) algorithm. Cell models adapted to the mutation measurements show a significantly shorter action potential (AP) with less pronounced spike-and-dome morphology. Results of single cell simulations compare with myocytes in chronic AF.


international conference on functional imaging and modeling of heart | 2011

Comparing simulated electrocardiograms of different stages of acute cardiac ischemia

Mathias Wilhelms; Olaf Dössel; Gunnar Seemann

Diagnosis of acute cardiac ischemia depends on characteristic shifts of the ST segment. The transmural extent of the ischemic region and the temporal stage of ischemia have an impact on these changes. In this work, computer simulations of realistic ventricles with different transmural extent of the ischemic region were carried out. Furthermore, three stages within the first half hour after the occlusion of the distal left anterior descending coronary artery were regarded. The transmembrane voltage distributions and the corresponding body surface ECGs were calculated. It was observed how the electrophysiological properties worsen in the course of ischemia, so that almost no excitation was initiated in the central ischemic zone 30 minutes after the occlusion. In addition to these temporal effects, also the transmural extent of the ischemic region had an impact on the direction and intensity of the ST segment shift.

Collaboration


Dive into the Mathias Wilhelms's collaboration.

Top Co-Authors

Avatar

Olaf Dössel

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Eberhard P. Scholz

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Axel Loewe

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Fathima Fischer

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

David U. J. Keller

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Jochen Schmid

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Julian Maier

University Hospital Heidelberg

View shared research outputs
Top Co-Authors

Avatar

Mathias J. Krause

Karlsruhe Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Niko Konrad

Karlsruhe Institute of Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge