Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where B. Sonny Bal is active.

Publication


Featured researches published by B. Sonny Bal.


Acta Biomaterialia | 2011

Bioactive glass in tissue engineering

Mohamed N. Rahaman; Delbert E. Day; B. Sonny Bal; Qiang Fu; Steven B. Jung; Lynda F. Bonewald; Antoni P. Tomsia

This review focuses on recent advances in the development and use of bioactive glass for tissue engineering applications. Despite its inherent brittleness, bioactive glass has several appealing characteristics as a scaffold material for bone tissue engineering. New bioactive glasses based on borate and borosilicate compositions have shown the ability to enhance new bone formation when compared to silicate bioactive glass. Borate-based bioactive glasses also have controllable degradation rates, so the degradation of the bioactive glass implant can be more closely matched to the rate of new bone formation. Bioactive glasses can be doped with trace quantities of elements such as Cu, Zn and Sr, which are known to be beneficial for healthy bone growth. In addition to the new bioactive glasses, recent advances in biomaterials processing have resulted in the creation of scaffold architectures with a range of mechanical properties suitable for the substitution of loaded as well as non-loaded bone. While bioactive glass has been extensively investigated for bone repair, there has been relatively little research on the application of bioactive glass to the repair of soft tissues. However, recent work has shown the ability of bioactive glass to promote angiogenesis, which is critical to numerous applications in tissue regeneration, such as neovascularization for bone regeneration and the healing of soft tissue wounds. Bioactive glass has also been shown to enhance neocartilage formation during in vitro culture of chondrocyte-seeded hydrogels, and to serve as a subchondral substrate for tissue-engineered osteochondral constructs. Methods used to manipulate the structure and performance of bioactive glass in these tissue engineering applications are analyzed.


Acta Biomaterialia | 2008

Mechanical and in vitro performance of 13–93 bioactive glass scaffolds prepared by a polymer foam replication technique

Qiang Fu; Mohamed N. Rahaman; B. Sonny Bal; Roger F. Brown; Delbert E. Day

A polymer foam replication technique was used to prepare porous scaffolds of 13-93 bioactive glass with a microstructure similar to that of human trabecular bone. The scaffolds, with a porosity of 85+/-2% and pore size of 100-500 microm, had a compressive strength of 11+/-1 MPa, and an elastic modulus of 3.0+/-0.5 GPa, approximately equal to the highest values reported for human trabecular bone. The strength was also considerably higher than the values reported for polymeric, bioactive glass-ceramic and hydroxyapatite constructs prepared by the same technique and with the equivalent level of porosity. The in vitro bioactivity of the scaffolds was observed by the conversion of the glass surface to a nanostructured hydroxyapatite layer within 7 days in simulated body fluid at 37 degrees C. Protein and MTT assays of in vitro cell cultures showed an excellent ability of the scaffolds to support the proliferation of MC3T3-E1 preosteoblastic cells, both on the surface and in the interior of the porous constructs. Scanning electron microscopy showed cells with a closely adhering, well-spread morphology and a continuous increase in cell density on the scaffolds during 6 days of culture. The results indicate that the 13-93 bioactive glass scaffolds could be applied to bone repair and regeneration.


Journal of Bone and Joint Surgery, American Volume | 2007

What’s New in Total Hip Arthroplasty

Michael H. Huo; Javad Parvizi; B. Sonny Bal; Michael A. Mont

Total hip arthroplasty remains one of the most effective and safe orthopaedic reconstructive procedures. A major focus over the past year has been the controversies regarding the safety of metal-on-metal articulation couplings and the associated adverse tissue reactions. Another area of focus has been on the outcome measures and practice protocols developed with evidence-based criteria. We have also included selected citations from the most recent published and presented data on the clinical outcomes and treatment of complications following total hip arthroplasty.


Journal of Biomedical Materials Research Part A | 2010

Silicate, borosilicate, and borate bioactive glass scaffolds with controllable degradation rate for bone tissue engineering applications. II. In vitro and in vivo biological evaluation

Qiang Fu; Mohamed N. Rahaman; B. Sonny Bal; Lynda F. Bonewald; Keiichi Kuroki; Roger F. Brown

In Part I, the in vitro degradation of bioactivAR52115e glass scaffolds with a microstructure similar to that of human trabecular bone, but with three different compositions, was investigated as a function of immersion time in a simulated body fluid. The glasses consisted of a silicate (13-93) composition, a borosilicate composition (designated 13-93B1), and a borate composition (13-93B3), in which one-third or all of the SiO2 content of 13-93 was replaced by B2O3, respectively. This work is an extension of Part I, to investigate the effect of the glass composition on the in vitro response of osteogenic MLO-A5 cells to these scaffolds, and on the ability of the scaffolds to support tissue infiltration in a rat subcutaneous implantation model. The results of assays for cell viability and alkaline phosphatase activity showed that the slower degrading silicate 13-93 and borosilicate 13-93B1 scaffolds were far better than the borate 13-93B3 scaffolds in supporting cell proliferation and function. However, all three groups of scaffolds showed the ability to support tissue infiltration in vivo after implantation for 6 weeks. The results indicate that the required bioactivity and degradation rate may be achieved by substituting an appropriate amount of SiO2 in 13-93 glass with B2O3, and that these trabecular glass scaffolds could serve as substrates for the repair and regeneration of contained bone defects.


Acta Biomaterialia | 2013

Mechanical properties of bioactive glass (13-93) scaffolds fabricated by robotic deposition for structural bone repair

Xin Liu; Mohamed N. Rahaman; Gregory E. Hilmas; B. Sonny Bal

There is a need to develop synthetic scaffolds to repair large defects in load-bearing bones. Bioactive glasses have attractive properties as a scaffold material for bone repair, but data on their mechanical properties are limited. The objective of the present study was to comprehensively evaluate the mechanical properties of strong porous scaffolds of silicate 13-93 bioactive glass fabricated by robocasting. As-fabricated scaffolds with a grid-like microstructure (porosity 47%, filament diameter 330μm, pore width 300μm) were tested in compressive and flexural loading to determine their strength, elastic modulus, Weibull modulus, fatigue resistance, and fracture toughness. Scaffolds were also tested in compression after they were immersed in simulated body fluid (SBF) in vitro or implanted in a rat subcutaneous model in vivo. As fabricated, the scaffolds had a strength of 86±9MPa, elastic modulus of 13±2GPa, and a Weibull modulus of 12 when tested in compression. In flexural loading the strength, elastic modulus, and Weibull modulus were 11±3MPa, 13±2GPa, and 6, respectively. In compression, the as-fabricated scaffolds had a mean fatigue life of ∼10(6) cycles when tested in air at room temperature or in phosphate-buffered saline at 37°C under cyclic stresses of 1-10 or 2-20MPa. The compressive strength of the scaffolds decreased markedly during the first 2weeks of immersion in SBF or implantation in vivo, but more slowly thereafter. The brittle mechanical response of the scaffolds in vitro changed to an elasto-plastic response after implantation for longer than 2-4weeks in vivo. In addition to providing critically needed data for designing bioactive glass scaffolds, the results are promising for the application of these strong porous scaffolds in loaded bone repair.


Journal of Biomedical Materials Research Part A | 2009

Effect of borate glass composition on its conversion to hydroxyapatite and on the proliferation of MC3T3‐E1 cells

Roger F. Brown; Mohamed N. Rahaman; Agatha B. Dwilewicz; Wenhai Huang; Delbert E. Day; Yadong Li; B. Sonny Bal

Glasses containing varying amounts of B(2)O(3) were prepared by partially or fully replacing the SiO(2) in silicate 45S5 bioactive glass with B(2)O(3). The effects of the B(2)O(3) content of the glass on its conversion to hydroxyapatite (HA) and on the proliferation of MC3T3-E1 cells were investigated in vitro. Conversion of the glasses to HA in dilute (20 mM) K(2)HPO(4) solution was monitored using weight loss and pH measurements. Proliferation of MC3T3-E1 cells was determined qualitatively by assay of cell density at the glass interface after incubation for 1 day and 3 days, and quantitatively by fluorescent measurements of total DNA in cultures incubated for 4 days. Higher B(2)O(3) content of the glass increased the conversion rate to HA, but also resulted in a greater inhibition of cell proliferation under static culture conditions. For a given mass of glass in the culture medium, the inhibition of cell proliferation was alleviated by using glasses with lower B(2)O(3) content, by incubating the cell cultures under dynamic rather than static conditions, or by partially converting the glass to HA prior to cell culture.


Acta Biomaterialia | 2012

Anti-infective and osteointegration properties of silicon nitride, poly(ether ether ketone), and titanium implants

Thomas J. Webster; Alpesh A. Patel; M.N. Rahaman; B. Sonny Bal

Silicon nitride (Si(3)N(4)) is an industrial ceramic used in spinal fusion and maxillofacial reconstruction. Maximizing bone formation and minimizing bacterial infection are desirable attributes in orthopedic implants designed to adhere to living bone. This study has compared these attributes of Si(3)N(4) implants with implants made from two other orthopedic biomaterials, i.e. poly(ether ether ketone) (PEEK) and titanium (Ti). Dense implants made of Si(3)N(4), PEEK, or Ti were surgically implanted into matching rat calvarial defects. Bacterial infection was induced with an injection of 1×10(4)Staphylococcus epidermidis. Control animals received saline only. On 3, 7, and 14days, and 3months post-surgery four rats per time period and material were killed, and calvariae were examined to quantify new bone formation and the presence or absence of bacteria. Quantitative evaluation of osteointegration to adjacent bone was done by measuring the resistance to implant push-out (n=8 rats each for Ti and PEEK, and n=16 rats for Si(3)N(4)). Three months after surgery in the absence of bacterial injection new bone formation around Si(3)N(4) was ∼69%, compared with 24% and 36% for PEEK and Ti, respectively. In the presence of bacteria new bone formation for Si(3)N(4), Ti, and PEEK was 41%, 26%, and 21%, respectively. Live bacteria were identified around PEEK (88%) and Ti (21%) implants, whereas none were present adjacent to Si(3)N(4). Push-out strength testing demonstrated statistically superior bone growth onto Si(3)N(4) compared with Ti and PEEK. Si(3)N(4) bioceramic implants demonstrated superior new bone formation and resistance to bacterial infection compared with Ti and PEEK.


Journal of Arthroplasty | 2009

Fabrication and testing of silicon nitride bearings in total hip arthroplasty: winner of the 2007 "HAP" PAUL Award.

B. Sonny Bal; Ashok Khandkar; Ramaswamy Lakshminarayanan; Ian C. Clarke; Aaron A. Hoffman; Mohamed N. Rahaman

Total hip arthroplasty (THA) bearings were fabricated from silicon nitride (Si(3)N(4)) powder. Mechanical testing showed that Si(3)N(4) had improved fracture toughness and fracture strength over modern alumina (Al(2)O(3)) ceramic. When tested with Si(3)N(4) cups in a hip simulator, both cobalt-chromium (CoCr) and Si(3)N(4) femoral heads produced low wear rates that were comparable to Al(2)O(3)-Al(2)O(3) bearings in THA. This study offers experimental support for a novel metal-ceramic THA bearing couple that combines the reliability of CoCr femoral heads with the wear advantages of ceramic surfaces.


Clinical Orthopaedics and Related Research | 2009

An Introduction to Medical Malpractice in the United States

B. Sonny Bal

Medical malpractice law in the United States is derived from English common law, and was developed by rulings in various state courts. Medical malpractice lawsuits are a relatively common occurrence in the United States. The legal system is designed to encourage extensive discovery and negotiations between adversarial parties with the goal of resolving the dispute without going to jury trial. The injured patient must show that the physician acted negligently in rendering care, and that such negligence resulted in injury. To do so, four legal elements must be proven: (1) a professional duty owed to the patient; (2) breach of such duty; (3) injury caused by the breach; and (4) resulting damages. Money damages, if awarded, typically take into account both actual economic loss and noneconomic loss, such as pain and suffering.


Journal of Biomedical Materials Research Part B | 2008

Freeze Casting of Porous Hydroxyapatite Scaffolds -- II. Sintering, Microstructure, and Mechanical Behavior

Qiang Fu; Mohamed N. Rahaman; Fatih Dogan; B. Sonny Bal

In Part I, the influence of processing parameters on the general microstructure of freeze-cast hydroxyapatite (HA) constructs was explored. This work is an extension of Part I to investigate the effect of sintering conditions on the microstructure and mechanical behavior of freeze-cast HA. For constructs prepared from aqueous suspensions (5-20 vol % HA), sintering for 3 h at temperatures from 1250 degrees C to 1375 degrees C produced a decrease in porosity of <5% but an increase in strength of nearly 50%. Constructs with a porosity of 52% had compressive strengths of 12 +/- 1 MPa and 5 +/- 1 MPa in the directions parallel and perpendicular to the freezing direction, respectively. The mechanical response showed high strain tolerance (5-10% at the maximum stress), high strain to failure (>20%), and high strain rate sensitivity. Manipulation of the freeze-cast microstructure, achieved by additions of glycerol and 1,4-dioxane to the aqueous suspensions, produced changes in the magnitude of the mechanical response, but little change in the general nature of the response. The favorable mechanical behavior of the porous constructs, coupled with the ability to modify their microstructure, indicates the potential of the present freeze-casting route for the production of porous scaffolds for bone tissue engineering.

Collaboration


Dive into the B. Sonny Bal's collaboration.

Top Co-Authors

Avatar

Mohamed N. Rahaman

Missouri University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Giuseppe Pezzotti

Kyoto Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Wenliang Zhu

Kyoto Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Qiang Fu

Missouri University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Elia Marin

Kyoto Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Alfredo Rondinella

Kyoto Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Wei Xiao

Missouri University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Delbert E. Day

Missouri University of Science and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge