Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Barry S. Shender is active.

Publication


Featured researches published by Barry S. Shender.


Spine | 2008

Anatomical gender differences in cervical vertebrae of size-matched volunteers.

Brian D. Stemper; Narayan Yoganandan; Frank A. Pintar; Dennis J. Maiman; Mark A. Meyer; John DeRosia; Barry S. Shender; Glenn Paskoff

Study Design. Clinical literature consistently identifies women as more susceptible to trauma-related neck pain, commonly resulting from soft tissue cervical spine injury. Structural gender differences may explain altered response to dynamic loading in women leading to increased soft tissue distortion and greater injury susceptibility. Objective. Identify anatomic gender differences in cervical spinal geometry that contribute to decreased column stability in women. Summary of Background Data. Previous studies investigating male and female vertebral and vertebral body geometry demonstrated female vertebral dimensions were smaller. However, populations were not size matched and parameters related to biomechanical stability were not reported. Methods. Computed tomography scans of the cervical spine were obtained from size-matched young healthy volunteers. Geometrical dimensions were obtained at the C4 level and analysis of variance determined significant gender differences. Results. Two volunteer subsets were size matched based on sitting height and head circumference. All geometrical measures were greater in men for both subsets. Vertebral width and disc-facet depth were significantly greater in men. Additionally, segmental support area, combining interfacet width and disc-facet depth, was greater in men, indicating more stable intervertebral coupling. Conclusion. Present results of decreased linear and areal cervical dimensions leading to decreased column stability may partially explain increased traumatic injury rates in women.


Spine | 2007

The temperature-dependent viscoelasticity of porcine lumbar spine ligaments.

Cameron R. Bass; Christopher J. Planchak; Robert S. Salzar; Scott Lucas; Karin A. Rafaels; Barry S. Shender; Glenn Paskoff

Study Design. A uniaxial tensile loading study of 13 lumbar porcine ligaments under varying environmental temperature conditions. Objectives. To investigate a possible temperature dependence of the material behavior of porcine lumbar anterior longitudinal ligaments. Summary of Background Data. Temperature dependence of the mechanical material properties of ligament has not been conclusively established. Methods. The anterior longitudinal ligaments (ALLs) from domestic pigs (n = 5) were loaded in tension to 20% strain using a protocol that included fast ramp/hold and sinusoidal tests. These ligaments were tested at temperatures of 37.8°C, 29.4°C, 21.1°C, 12.8°C, and 4.4°C. The temperatures were controlled to within 0.6°C, and ligament hydration was maintained with a humidifier inside the test chamber and by spraying 0.9% saline onto the ligament. A viscoelastic model was used to characterize the force response of the ligaments. Results. The testing indicated that the ALL has strong temperature dependence. As temperature decreased, the peak forces increased for similar input peak strains and strain rates. The relaxation of the ligaments was similar at each temperature and showed only weak temperature dependence. Predicted behavior using the viscoelastic model compared well with the actual data (R2 values ranging from 0.89 to 0.99). A regression analysis performed on the viscoelastic model coefficients confirmed that relaxation coefficients were only weakly temperature dependent while the instantaneous elastic function coefficients were strongly temperature dependent. Conclusions. The experiment demonstrated that the viscoelastic mechanical response of the porcine ligament is dependent on the temperature at which it is tested; the force response of the ligament increased as the temperature decreased. This conclusion also applies to human ligaments owing to material and structural similarity. This result settles a controversy on the temperature dependence of ligament in the available literature. The ligament viscoelastic model shows a significant temperature dependence on the material properties; instantaneous elastic force was clearly temperature dependent while the relaxation response was only weakly temperature dependent. This result suggests that temperature dependence should be considered when testing ligaments and developing material models for in vivo force response, and further suggests that previously published material property values derived from room temperature testing may not adequately represent in vivo response. These findings have clinical relevance in the increased susceptibility of ligamentous injury in the cold and in assessing the mechanical behavior of cold extremities and extremities with limited vascular perfusion such as those of the elderly.


Spine | 2008

Quantitative anatomy of subaxial cervical lateral mass: an analysis of safe screw lengths for Roy-Camille and magerl techniques.

Brian D. Stemper; Satyajit V. Marawar; Narayan Yoganandan; Barry S. Shender; Raj D. Rao

Study Design. Determination of lateral mass screw lengths with Roy-Camille and Magerl techniques of screw insertion using computerized tomography in 98 young, asymptomatic North American volunteers. Objective. To provide reliable and normative data on safe screw lengths using the Roy-Camille and Magerl techniques of lateral mass fixation in the subaxial cervical spine. Summary of Background Data. Lateral mass screw lengths have been studied in the past using differing subject and measurement characteristics and small sample sizes. Results demonstrated considerable variation in screw length and influencing factors. Inappropriate screw lengths can result in neurovascular injury during screw insertion, facet joint damage, or inadequate fixation. Methods. Bicortical screw lengths were bilaterally measured at each spinal level from C3–C7 in 98 young volunteers using computed tomography reconstructions through the lateral masses obtained in the plane of the screw in Roy-Camille and Magerl techniques. Results. With both techniques, trajectories were longest at C4–C6, shorter at C3, and shortest at C7. Screw lengths were greater in males when compared with females at all levels. Average Magerl screw lengths were approximately 2.6 mm longer at C3–C6 levels, and approximately 1.3 mm longer at the C7 level when compared with Roy-Camille technique. There was minimal correlation between screw lengths and anthropometric measurements including stature, body weight, and neck length. Conclusion. Significant variations exist at each subaxial level with either technique. We recommend the surgeon determine screw lengths for fixation at each level using preoperative sagittal oblique computed tomography scans, which provide the most accurate technique of preoperative templating for screw length.


Spine | 2006

Bone mineral density of human female cervical and lumbar spines from quantitative computed tomography

Narayan Yoganandan; Frank A. Pintar; Brian D. Stemper; Jamie L. Baisden; Recai Aktay; Barry S. Shender; Glenn Paskoff

Study Design. This study determined bone mineral density (BMD) of cervical, thoracic, and lumbar vertebrae in healthy asymptomatic human subjects. Objectives. To test the hypothesis that BMD of neck vertebrae (C2–C7) is equivalent to BMD of lumbar vertebrae (L2–L4). Summary of Background Data. BMD of lumbar vertebrae is correlated to their strength. Although numerous studies exist quantifying BMD of the human lumbar spine, such information for the cervical spine is extremely limited. In addition, BMD correlations are not established between the two regions of the spinal column. Methods. Adult healthy human female volunteers with ages ranging from 18 to 40 years underwent quantitative computed tomography (CT) scanning of the neck and back. All BMD data were statistically analyzed using paired nonrepeating measures ANOVA techniques. Significance was assigned at a P < 0.05. Linear regression analyses were used to compare BMD as a function of level and region; ±95% confidence intervals were determined. Results. When data were grouped by cervical (C2–C7), thoracic (T1), and lumbar (L2–L4) spines, mean BMD was 260.8 ± 42.5, 206.9 ± 33.5, and 179.7 ± 23.4 mg/mL. Average BMD of cervical vertebrae was higher than (P < 0.0001) thoracic and lumbar spines. Correlations between BMD and level indicated the lowest r value for T1 (0.42); in general, the association was the strongest in the lumbar spine (r = 0.89–0.95). The cervical spine also responded with good correlations among cervical vertebrae (r ranging from 0.66 to 0.87). Conclusions. The present study failed to support the hypothesis that BMD of lumbar spine vertebrae is equivalent to its cranial counterparts. The lack of differences in BMD among the three lumbar vertebral bodies confirms the appropriateness of using L2, L3, or L4 in clinical or biomechanical situations. However, significant differences were found among different regions of the vertebral column, with the cervical spine demonstrating higher trabecular densities than the thoracic and lumbar spines. In addition, the present study found statistically significant variations in densities even among neck vertebrae.


Spine | 2007

Failure properties of cervical spinal ligaments under fast strain rate deformations.

Cameron R. Bass; Scott Lucas; Robert S. Salzar; Michelle L. Oyen; Chris Planchak; Barry S. Shender; Glenn Paskoff

Study Design. The failure responses of the anterior longitudinal ligament, posterior longitudinal ligament, and ligamentum flavum were examined in vitro under large strain-rate mechanical loading. Objective. To quantify the failure properties for 3 cervical spinal ligaments at strain rates associated with traumatic events. Summary of Background Data. There exists little experimentation literature for fast- rate loading of the cervical spine ligaments. The small amount of available information is framed only in extensive experimental coordinates, and not in the context of strains. Methods. Bone-ligament-bone complexes were strained at fast rates, in an incrementally increasing loading protocol using a servohydraulic mechanical test frame. Failure loads and displacements were converted to engineering and true stress and strain values, and compared for the different ligaments (anterior longitudinal ligament, posterior longitudinal ligament, and ligamentum flavum), spinal levels (C3–C4, C5–C6, and C7–T1), and for male versus female specimens. Results. There were no significant differences in force or true stress for gender or spinal level. There was a significant difference in force and true stress for ligament type. A difference was found between the posterior longitudinal ligament and ligamentum flavum for failure force, and between the ligamentum flavum and both the anterior and posterior longitudinal ligaments for failure true stress. No significant differences were found in true strain for ligament, gender, or spinal level. The mean ligament failure true strain was 0.81. Failure true strains were approximately 57% of the failure engineering strains. Conclusions. Once the injury mechanisms of the cervical spine are fully understood, computational models can be employed to understand the potentially traumatic effects of clinical procedures, and mitigate injury in impact, falls, and other high-rate scenarios. The soft tissue failure properties in this study can be used to develop failure tolerances in fast-rate loading scenarios. Failure properties of the anterior and posterior longitudinal ligaments were similar, and the same properties can be used to model both ligaments.


Journal of Bone and Joint Surgery, American Volume | 2008

Computerized Tomographic Morphometric Analysis of Subaxial Cervical Spine Pedicles in Young Asymptomatic Volunteers

Raj D. Rao; Satyajit V. Marawar; Brian D. Stemper; Narayan Yoganandan; Barry S. Shender

BACKGROUND Although cervical spine pedicle screws have been shown to provide excellent fixation, widespread acceptance of their use is limited because of the risk of injury to the spinal cord, nerve roots, and vertebral arteries. The risks of pedicle screw insertion in the cervical spine can be mitigated by a three-dimensional appreciation of pedicle anatomy. Normative data on three-dimensional subaxial pedicle geometry from a large, young, and asymptomatic North American population are lacking. The purpose of the present study was to determine three-dimensional subaxial pedicle geometry in a large group of young volunteers and to determine level and sex-specific morphologic differences. METHODS Helical computerized tomography scans were made from the third cervical to the seventh cervical vertebra in ninety-eight volunteers (sixty-three men and thirty-five women) with an average age of twenty-five years. Pedicle width, height, length, and transverse and sagittal angulations were measured bilaterally. Pedicle screw insertion positions were quantified in terms of mediolateral and superoinferior offsets relative to readily identifiable landmarks. RESULTS The mean pedicle width and height at all subaxial levels were sufficient to accommodate 3.5-mm screws in 98% of the volunteers. Pedicle width and height dimensions of <4.0 mm were rare (observed in association with only 1.7% of the pedicles), with 82% occurring in women and 72% occurring unilaterally. Screw insertion positions generally moved medially and superiorly at caudal levels. Transverse angulation was approximately 45 degrees at the third to fifth cervical levels and was less at more caudal levels. Sagittal angulation changed from a cranial orientation at superior levels to a caudal orientation at inferior levels. Mediolateral and superoinferior insertion positions and sagittal angulations were significantly dependent (p < 0.05) on sex and spinal level. Transverse angulation was significantly dependent (p < 0.05) on spinal level. CONCLUSIONS Pedicle screw insertion points and orientation are significantly different (p < 0.05) at most subaxial cervical levels and between men and women. Preoperative imaging studies should be carefully templated for pedicle size in all patients on a level-specific basis. Although the prevalence was low, women were more likely to have pedicle width and height dimensions of <4.0 mm.


Journal of Bone and Joint Surgery, American Volume | 2007

Level-dependent coronal and axial moment-rotation corridors of degeneration-free cervical spines in lateral flexion

Narayan Yoganandan; Frank A. Pintar; Brian D. Stemper; Christopher E. Wolfla; Barry S. Shender; Glenn Paskoff

BACKGROUND Aging, trauma, or degeneration can affect intervertebral kinematics. While in vivo studies can determine motions, moments are not easily quantified. Previous in vitro studies on the cervical spine have largely used specimens from older individuals with varying levels of degeneration and have shown that moment-rotation responses under lateral bending do not vary significantly by spinal level. The objective of the present in vitro biomechanical study was, therefore, to determine the coronal and axial moment-rotation responses of degeneration-free, normal, intact human cadaveric cervicothoracic spinal columns under the lateral bending mode. METHODS Nine human cadaveric cervical columns from C2 to T1 were fixed at both ends. The donors had ranged from twenty-three to forty-four years old (mean, thirty-four years) at the time of death. Retroreflective targets were inserted into each vertebra to obtain rotational kinematics in the coronal and axial planes. The specimens were subjected to pure lateral bending moment with use of established techniques. The range-of-motion and neutral zone metrics for the coronal and axial rotation components were determined at each level of the spinal column and were evaluated statistically. RESULTS Statistical analysis indicated that the two metrics were level-dependent (p < 0.05). Coronal motions were significantly greater (p < 0.05) than axial motions. Moment-rotation responses were nonlinear for both coronal and axial rotation components under lateral bending moments. Each segmental curve for both rotation components was well represented by a logarithmic function (R(2) > 0.95). CONCLUSIONS Range-of-motion metrics compared favorably with those of in vivo investigations. Coronal and axial motions of degeneration-free cervical spinal columns under lateral bending showed substantially different level-dependent responses. The presentation of moment-rotation corridors for both metrics forms a normative dataset for the degeneration-free cervical spines.


Journal of Biomechanics | 2011

Effects of tissue preservation temperature on high strain-rate material properties of brain

Jiangyue Zhang; Narayan Yoganandan; Frank A. Pintar; Yabo Guan; Barry S. Shender; Glenn Paskoff; Purushottam W. Laud

Postmortem preservation conditions may be one of factors contributing to wide material property variations in brain tissues in literature. The objective of present study was to determine the effects of preservation temperatures on high strain-rate material properties of brain tissues using the split Hopkinson pressure bar (SHPB). Porcine brains were harvested immediately after sacrifice, sliced into 2 mm thickness, preserved in ice cold (group A, 10 samples) and 37°C (group B, 9 samples) saline solution and warmed to 37°C just prior to the test. A SHPB with tube aluminum transmission bar and semi-conductor strain gauges were used to enhance transmitted wave signals. Data were gathered using a digital acquisition system and processed to obtain stress-strain curves. All tests were conducted within 4 h postmortem. The mean strain-rate was 2487±72 s(-1). A repeated measures model with specimen-level random effects was used to analyze log transformed stress-strain responses through the entire loading range. The mean stress-strain curves with ±95% confidence bands demonstrated typical power relationships with the power value of 2.4519 (standard error, 0.0436) for group A and 2.2657 (standard error, 0.0443) for group B, indicating that responses for the two groups are significantly different. Stresses and tangent moduli rose with increasing strain levels in both groups. These findings indicate that storage temperatures affected brain tissue material properties and preserving tissues at 37°C produced a stiffer response at high strain-rates. Therefore, it is necessary to incorporate material properties obtained from appropriately preserved tissues to accurately predict the responses of brain using stress analyses models, such as finite element simulations.


Journal of Biomechanical Engineering-transactions of The Asme | 2011

A New PMHS Model for Lumbar Spine Injuries During Vertical Acceleration

Brian D. Stemper; Steven G. Storvik; Narayan Yoganandan; Jamie L. Baisden; Ronald J. Fijalkowski; Frank A. Pintar; Barry S. Shender; Glenn Paskoff

Ejection from military aircraft exerts substantial loads on the lumbar spine. Fractures remain common, although the overall survivability of the event has considerably increased over recent decades. The present study was performed to develop and validate a biomechanically accurate experimental model for the high vertical acceleration loading to the lumbar spine that occurs during the catapult phase of aircraft ejection. The model consisted of a vertical drop tower with two horizontal platforms attached to a monorail using low friction linear bearings. A total of four human cadaveric spine specimens (T12-L5) were tested. Each lumbar column was attached to the lower platform through a load cell. Weights were added to the upper platform to match the thorax, head-neck, and upper extremity mass of a 50th percentile male. Both platforms were raised to the drop height and released in unison. Deceleration characteristics of the lower platform were modulated by foam at the bottom of the drop tower. The upper platform applied compressive inertial loads to the top of the specimen during deceleration. All specimens demonstrated complex bending during ejection simulations, with the pattern dependent upon the anterior-posterior location of load application. The model demonstrated adequate inter-specimen kinematic repeatability on a spinal level-by-level basis under different subfailure loading scenarios. One specimen was then exposed to additional tests of increasing acceleration to induce identifiable injury and validate the model as an injury-producing system. Multiple noncontiguous vertebral fractures were obtained at an acceleration of 21 g with 488 g/s rate of onset. This clinically relevant trauma consisted of burst fracture at L1 and wedge fracture at L4. Compression of the vertebral body approached 60% during the failure test, with -6,106 N axial force and 168 Nm flexion moment. Future applications of this model include developing a better understanding of the vertebral injury mechanism during pilot ejection and developing tolerance limits for injuries sustained under a variety of different vertical acceleration scenarios.


Spine | 2008

Normative segment-specific axial and coronal angulation corridors of subaxial cervical column in axial rotation.

Narayan Yoganandan; Brian D. Stemper; Frank A. Pintar; Jamie L. Baisden; Barry S. Shender; Glenn Paskoff

Study Design. In contrast to clinical studies wherein loading magnitudes are indeterminate, experiments permit controlled and quantifiable moment applications, record kinematics in multiple planes, and allow derivation of moment-angulation corridors. Axial and coronal moment-angulation corridors were determined at every level of the subaxial cervical spine, expressed as logarithmic functions, and level-specificity of range of motion and neutral zones were evaluated. Objective. Hypothesis: segmental primary axial and coupled coronal motions do not vary by level. Summary of Background Data. Although it is known that cervical spine responses are coupled, segment-specific corridors of axial and coronal kinematics under axial twisting moments from healthy normal spines are not reported. Methods. Ten human cadaver columns (23–44 years, mean: 34 ± 6.8) were fixed at the ends and targets were inserted to each vertebra to obtain kinematics in axial and coronal planes. The columns were subjected to pure axial twisting moments. Range of motion and neutral zone for primary-axial and coupled-coronal rotation components were determined at each spinal level. Data were analyzed using factorial analysis of variance. Moment-rotation angulations were expressed using logarithmic functions, and mean ±1 standard deviation corridors were derived at each level for both components. Results. Moment-angulations responses were nonlinear. Each segmental curve for both components was well represented by a logarithmic function (r2 > 0.95). Factorial analysis of variance indicated that the biomechanical metrics are spinal level-specific (P < 0.05). Conclusion. Axial and coronal angulations of cervical spinal columns show statistically different level-specific responses. The presentation of moment-angulation corridors for both metrics forms a dataset for the normal population. These segment-specific nonlinear corridors may help clinicians assess dysfunction or instability. These data will assist mathematical models of the spine in improved validation and lead to efficacious design of stabilizing systems.

Collaboration


Dive into the Barry S. Shender's collaboration.

Top Co-Authors

Avatar

Glenn Paskoff

Naval Air Systems Command

View shared research outputs
Top Co-Authors

Avatar

Brian D. Stemper

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar

Narayan Yoganandan

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar

Frank A. Pintar

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar

Jamie L. Baisden

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dennis J. Maiman

Medical College of Wisconsin

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

William H. Curry

Medical College of Wisconsin

View shared research outputs
Researchain Logo
Decentralizing Knowledge