Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Basirom Izzawati is active.

Publication


Featured researches published by Basirom Izzawati.


international conference functional materials and metallurgy | 2015

Strength of Adhesive T-Joint in Granulator Fluidization Bed at Elevated Temperature

Basirom Izzawati; Mohd Afendi; S. Nurhashima; A. Nor; A.R. Abdullah; R. Daud; M.S. Abdul Majid

This paper presents the results of an experimental investigation on mechanical characterization of adhesive T-joint in granulator fluidization bed at elevated temperature. This research aims to explore the suitability of adhesive bonding between stainless steel plate and perforated plate to replace plug weld in granulator fluidization bed. For this purpose, T-joint and bulk specimens were prepared for tensile loading tests, at different temperature. Measurement of the temperature-dependent of the tensile strength was conducted using thermostatic chamber attached to a universal testing machine for a range from room temperature to 100°C. The strength of adhesive T-joint decreases for temperatures over than 35°C. This is because at high temperature, the failure is determined by the changes of mechanical properties of adhesive. The results have shown that the strength of adhesive T-joint was affected by both temperature and bondline thickness. The objective of the present study was to examine a series of adhesively-bonded T-joints in tension at elevated temperatures between room temperature and 100°C having various bond thicknesses.


Journal of Physics: Conference Series | 2017

Stress analysis of implant-bone fixation at different fracture angle

Basirom Izzawati; R. Daud; Mohd Afendi; M.S. Abdul Majid; N. A.M. Zain; Y. Bajuri

Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.


3RD ELECTRONIC AND GREEN MATERIALS INTERNATIONAL CONFERENCE 2017 (EGM 2017) | 2017

Convergence and stress analysis of the homogeneous structure of human femur bone during standing up condition

Basirom Izzawati; R. Daud; Mohd Afendi; M.S. Abdul Majid; N. A.M. Zain

Finite element models have been widely used to quantify the stress analysis and to predict the bone fractures of the human body. The present study highlights on the stress analysis of the homogeneous structure of human femur bone during standing up condition. The main objective of this study is to evaluate and understand the biomechanics for human femur bone and to prepare orthotropic homogeneous material models used for FE analysis of the global proximal femur. Thus, it is necessary to investigate critical stress on the human femur bone for future study on implantation of internal fixator and external fixator. The implication possibility to create a valid FE model by simply comparing the FE results with the actual biomechanics structures. Thus, a convergence test was performed by FE model of the femur and the stress analysis based on the actual biomechanics of the human femur bone. An increment of critical stress shows in the femur shaft as the increasing of load on the femoral head and decreasing the pu...


international conference functional materials and metallurgy | 2015

Strength of Adhesive T-Joint under Moisture Condition

S. Nurhashima; Mohd Afendi; Basirom Izzawati; A. Nor; A.R. Abdullah; N.A.M. Amin; M.S. Abdul Majid; R. Daud

In this study, an experimental investigation was conducted in order to determine the effect of moisture absorption at different adhesive thickness (i.e., 0.5, 1.0, 1.5 and 2.0 mm) on strength of adhesive T-joint in urea granulator fluidization bed. In particular, T-joint specimens were exposed to three humidity conditions, namely, 80°C, 90°C, and 100°C at a constant time immersion of 15 minutes in water. Stainless steel plate and stainless steel perforated plate were joined by using a specific adhesive jig according to desired thickness. Tensile test was conducted by using universal tensile machine (UTM) at room temperature. The result obtained has enabled to explain the failure mechanisms and characteristics of adhesive T-joint with respect to moisture condition and bonding thickness. Epoxy adhesive with several weight percent of water absorption will degrade the physical properties of the adhesive. Moisture condition has some effect on the strength of the adhesive bonding. 1.0 mm of adhesive thickness provides the highest value of failure load. Experimental results indicated that failure load of adhesive T-joint at room and 90°C water temperature give higher value of strength if compared to water temperature at 80°C and 100°C.


Applied Mechanics and Materials | 2015

Evaluation of Adhesive T-Joint Using Finite Element Analysis

Basirom Izzawati; Mohd Afendi; S. Nurhashima; A. Nor; A.R. Abdullah; R. Daud

This study evaluates the effect of temperature upon adhesive properties and behavior of adhesively bonded T-joint. Finite element analyses established the effect of this parameter on the durability joint and stress distribution within the adhesive layer. A series of temperatures and stress analyses using finite element analysis (FEA) has been conducted in the T-joint configuration for this purpose. The parametric studies on the FE model revealed that stress distributions are sensitive to the changes in adhesive properties due to changes in temperature. In general, stresses were reduced with changes in the temperature which resulted in the ability of the adhesive layer to undergo plastic deformation.


Applied Mechanics and Materials | 2015

Failure Stress Analysis of Adhesive T-Joint under Moisture Condition

S. Nurhashima; Mohd Afendi; Basirom Izzawati; A. Nor; A.R. Abdullah; N.A.M. Amin; M.S. Abdul Majid; R. Daud

The use of adhesive structural in joining application offers the great demand due to its many advantages such as lightweight structures and flexible design. However, moisture provides significant problem and adverse effect on degrading the adhesive. The strength of the adhesive reduces because mechanical properties are known to reduce also with moisture environment. Therefore, this paper discusses about the adhesive T-joint test on specimen within moisture condition and specimen without moisture, at room temperature. Additionally, this study also analyses the failure stress when load is applied for both exposed conditions. Bulk specimens are compressed at room temperature, specimen without immersing in hot water, RT and specimen with immersing in three hot water conditions 80°C, 90°C, and 100°C at a constant time of 15 minutes. The adhesive of a 1.0mm thickness has been set for T-joint tensile test. Compression test revealed that mechanical properties of Young’s modulus decreased with the increase of water temperature. Experimental results indicated that the failure stress of adhesive T-joint at room temperature and 90°C was higher compared to that of specimen soaked in 80°C and 100°C of hot water. The behaviour of adhesive joint tests under static loading analysis of experiments and the finite element analysis using ANSYS 14.0 software have shown good agreement.


Applied Mechanics and Materials | 2015

Finite Element Stress Analysis of Adhesive T-Joint with Crack in Fluidization Bed

A. Nor; Mohd Afendi; M.S. Abdul Majid; Basirom Izzawati; S. Nurhashima; A.R. Abdullah

In this study, adhesive T-joint with crack in urea granulator fluidization bed was analyzed by finite element (FE) analysis. Objectives of this project were to examine a series of adhesively bonded T- joints with crack under mode I loading, to evaluate stress analysis of adhesive T-joint with crack at top and bottom and to identify the effective bond thickness. The path was drawn in ANSYS at the top and bottom of adhesive from side view to find which part has higher stress. The result of both paths top and bottom analysis shows the stress distribution always higher at both edges. So, the crack was inserted at interface edges and the stress distribution was evaluated. From interface edges stress distribution result of top and bottom, it shows that bottom edge has higher stress compare with top edge. The failure load analysis will compare with other analysis and experiment result. It is found that adhesive T-joint with 1.5mm is the best thickness for granulator fluidization bed application because always has higher failure load.


Applied Mechanics and Materials | 2014

Tensile Shear Strength of Wood Adhesive from Recycled Polystyrene

Muhammad Azrie Husainy Mohd Jasri; Mohd Afendi; N.Z. Nik; Basirom Izzawati; S. Nurhashima; A. Nor; S. Yahud; N.A.M. Amin

This paper discloses a method to recycle polystyrene (PS) waste by adding ethanol based hydrocarbons solvent to produce a novel adhesive for wood joining application. In the experiments, tensile shear strength of wood lap joint having various overlap lengths was conducted. It was found that this new adhesive has significant shear strength as compared to commercial wood adhesive. This relatively low cost adhesive has potential to be used for wood joining application especially in marine structures.


Applied Mechanics and Materials | 2014

3D Finite Element Stress Analysis of Butt Adhesively Bonded Dissimilar Joint: Effect of Bond Thickness on Strength

Basirom Izzawati; Mohd Afendi; M. Afif; S. Nurhashima; R. Daud; N.A.M. Amin; M.S. Abdul Majid

The butt joint is the most studied type of adhesive joints in the literature. However, the joint strength prediction of joints is still a controversial issue as it involves a lot of factors that are difficult to quantify such as the yielding of the adherend, the plasticity of the adhesive and the bondline thickness. The present work is concerned with the three dimensional (3D) finite element stress analysis of butt adhesively bonded dissimilar joint. The objective of the present study was to analyse the effect of bond thickness on mechanical strength of butt adhesively bonded dissimilar joint. Aluminum alloy and steel were selected and five thicknesses were studied for each adherend: 0.2, 0.4, 0.6, 0.8, and 1.0 mm respectively. In order to quantify the influence of bondline thickness, adherend and durability of the butt joint, the 3D finite element models of ANSYS used to obtain the stress distributions. Mechanical properties of adhesive were determined by tensile test and ANSYS analysis. A statistical analysis of simulation results shows that the butt joint strength becomes stronger while the bondline gets thinner and adhesive gets tougher.


Applied Mechanics and Materials | 2014

Experimental Investigation and FE Stress Analysis of Adhesive T-Joint with and without Crack in Fluidization Bed

A. Nor; Mohd Afendi; Mohd Shukry Abdul Majid; Basirom Izzawati; S. Nurhashima; A.R. Abdullah

In this study, investigation on adhesive T-joint with and without crack in urea granulator fluidization bed was carried out by experiment and finite element (FE) analysis. Specimens with and without crack were made from actual size of 1.25 mm perforated plate to duplicate actual structure of granulator fluidization bed and verified using commercial finite element. The existence of crack will affect the strength of adhesive T-joint. The objectives of this project were to examine a series of adhesively bonded T-joints with and without crack under mode I loading, to identify the effective bond thickness by tensile testing and FE analysis. It was found that result pattern from experiment was in agreement with FE analysis.

Collaboration


Dive into the Basirom Izzawati's collaboration.

Top Co-Authors

Avatar

Mohd Afendi

Universiti Malaysia Perlis

View shared research outputs
Top Co-Authors

Avatar

S. Nurhashima

Universiti Malaysia Perlis

View shared research outputs
Top Co-Authors

Avatar

A. Nor

Universiti Malaysia Perlis

View shared research outputs
Top Co-Authors

Avatar

M.S. Abdul Majid

Universiti Malaysia Perlis

View shared research outputs
Top Co-Authors

Avatar

R. Daud

Universiti Malaysia Perlis

View shared research outputs
Top Co-Authors

Avatar

A.R. Abdullah

Universiti Malaysia Perlis

View shared research outputs
Top Co-Authors

Avatar

N.A.M. Amin

Universiti Malaysia Perlis

View shared research outputs
Top Co-Authors

Avatar

N. A.M. Zain

Universiti Malaysia Perlis

View shared research outputs
Top Co-Authors

Avatar

M. Afif

Universiti Malaysia Perlis

View shared research outputs
Top Co-Authors

Avatar

M. Taufik

Universiti Malaysia Perlis

View shared research outputs
Researchain Logo
Decentralizing Knowledge