Benjamin Cruz Perez
Ohio State University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Benjamin Cruz Perez.
Investigative Ophthalmology & Visual Science | 2013
Hugh J. Morris; Junhua Tang; Benjamin Cruz Perez; Xueliang Pan; Richard T. Hart; Paul A. Weber; Jun Liu
PURPOSE This study tested the hypothesis that intraocular pressure (IOP) elevations, induced by controlled increase of intraocular volume, are correlated with the biomechanical responses of the posterior sclera. METHODS Porcine globes were tested within 48 hours postmortem. The first group of globes (n = 11) was infused with 15 μL of phosphate-buffered saline at three different rates to investigate rate-dependent IOP elevations. The second group (n = 16) was first infused at the fast rate and then underwent inflation tests to investigate the relationship between IOP elevations (ΔIOP) and scleral strains. The strains in the superotemporal region of the posterior sclera were measured by ultrasound speckle tracking. Linear regression was used to examine the association between ΔIOP due to micro-volumetric infusion and the scleral strains at a specific inflation pressure. RESULTS The average ΔIOP was 14.9 ± 4.3 mm Hg for the infusion of 15 μL in 1 second. The ΔIOP was greater for the faster infusion rates but highly correlated across different rates (P < 0.001). A significant negative association was found between the ΔIOP and the tangential strains in both the circumferential (R(2) = 0.54, P = 0.003) and meridian (R(2) = 0.53, P = 0.002) directions in the posterior sclera. CONCLUSIONS This study showed a substantial increase in IOP, with a large intersubject variance during micro-volumetric change. A stiffer response of the sclera was associated with larger IOP spikes, providing experimental evidence linking corneoscleral biomechanics to IOP fluctuation. In vivo measurement of corneoscleral biomechanics may help better predict the dynamic profile of IOP.
Journal of Biomechanics | 2014
Benjamin Cruz Perez; Junhua Tang; Hugh J. Morris; Joel R. Palko; Xueliang Pan; Richard T. Hart; Jun Liu
This study aimed to characterize the mechanical responses of the sclera, the white outer coat of the eye, under equal-biaxial loading with unrestricted shear. An ultrasound speckle tracking technique was used to measure tissue deformation through sample thickness, expanding the capabilities of surface strain techniques. Eight porcine scleral samples were tested within 72 h postmortem. High resolution ultrasound scans of scleral cross-sections along the two loading axes were acquired at 25 consecutive biaxial load levels. An additional repeat of the biaxial loading cycle was performed to measure a third normal strain emulating a strain gage rosette for calculating the in-plane shear. The repeatability of the strain measurements during identical biaxial ramps was evaluated. A correlation-based ultrasound speckle tracking algorithm was used to compute the displacement field and determine the distributive strains in the sample cross-sections. A Fung type constitutive model including a shear term was used to determine the material constants of each individual specimen by fitting the model parameters to the experimental stress-strain data. A non-linear stress-strain response was observed in all samples. The meridian direction had significantly larger strains than that of the circumferential direction during equal-biaxial loadings (Ps<0.05). The stiffness along the two directions was also significantly different (P=0.02) but highly correlated (R(2)=0.8). These results showed that the mechanical properties of the porcine sclera were nonlinear and anisotropic under biaxial loading. This work has also demonstrated the feasibility of using ultrasound speckle tracking for strain measurements during mechanical testing.
Journal of Cataract and Refractive Surgery | 2014
Joel R. Palko; Junhua Tang; Benjamin Cruz Perez; Xueliang Pan; Jun Liu
Purpose To determine the heterogeneous through‐thickness strains in the cornea at physiologic intraocular pressures before and after corneal collagen crosslinking (CXL) using noninvasive ultrasound. Setting Department of Biomedical Engineering, Ohio State University, Columbus, Ohio, USA. Design Experimental study. Methods Sixteen paired canine corneoscleral shells were divided into 2 groups. The CXL group completed a standard CXL protocol using riboflavin–ultraviolet‐A (UVA) irradiation. The control group was given an identical treatment except UVA irradiation. Ultrasound scans (at 55 MHz) of the cornea were obtained before and after treatment as the corneoscleral shell was inflated from 5 mm Hg to 45 mm Hg to calculate the distributive through‐thickness strains in the cornea. The mean radial and tangential strains of the whole cornea layer, as well as those of the anterior, middle, and posterior thirds of the cornea, were compared before and after treatment in the control group and CXL group using linear mixed models with repeated measures. Results Significant reductions in tangential and radial strains occurred in the CXL group (P=.003 and P=.0025, respectively) but not the control group (P=.08 and P=.63, respectively). The anterior third had the smallest strains in all pretreated corneas (P<.001) and posttreated corneas (CXL group, P=.023; control group, P=.01). Conclusions Ultrasound speckle tracking showed heterogeneous strain distributions through the cornea and confirmed that CXL results in a stiffer corneal response (ie, smaller strains during physiologic loadings). This technique may provide a clinical tool to quantify the biomechanical effects of CXL. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
Journal of Biomechanical Engineering-transactions of The Asme | 2016
Elias Pavlatos; Benjamin Cruz Perez; Hugh J. Morris; Hong Chen; Joel R. Palko; Xueliang Pan; Paul A. Weber; Richard T. Hart; Jun Liu
Intraocular pressure (IOP) induced strains in the peripapillary sclera may play a role in glaucoma progression. Using inflation testing and ultrasound speckle tracking, the 3D strains in the peripapillary sclera were measured in nine human donor globes. Our results showed that the peripapillary sclera experienced through-thickness compression and meridional stretch during inflation, while minimal circumferential dilation was observed when IOP was increased from 10 to 19 mmHg. The maximum shear was primarily oriented in the through-thickness, meridional cross sections and had a magnitude slightly larger than the first principal strain. The tissue volume had minimal overall change, confirming near-incompressibility of the sclera. Substantial strain heterogeneity was present in the peripapillary region, with local high strain areas likely corresponding to structural heterogeneity caused by traversing blood vessels. These 3D strain characteristics provide new insights into the biomechanical responses of the peripapillary sclera during physiological increases of IOP. Future studies are needed to confirm these findings and investigate the role of these biomechanical characteristics in ocular diseases.
Journal of Biomedical Science and Engineering | 2013
Benjamin Cruz Perez; Hugh J. Morris; Richard T. Hart; Jun Liu
A linear viscoelastic finite element model was built to investigate factors that influenced the intraocular pressure (IOP) elevations due to micro-volumetric changes in the eye at three different rates. The viscoelastic properties of the cornea and the sclera, including the instantaneous modulus, equilibrium modulus, and relaxation time constants, parametrically varied to examine their effects on IOP elevations at different rates of volumetric changes. The simulated responses were in good agreement with the previously reported experimental results obtained from porcine globes, showing the general trend of higher IOP elevations at faster rates. The simulations showed that all viscoelastic properties influenced the profile of the dynamic IOP due to volumetric changes, and the relative significance of a specific parameter was highly dependent on the rate of change.
Annals of Biomedical Engineering | 2016
Benjamin Cruz Perez; Elias Pavlatos; Hugh J. Morris; Hong Chen; Xueliang Pan; Richard T. Hart; Jun Liu
Investigative Ophthalmology & Visual Science | 2013
Benjamin Cruz Perez; Junhua Tang; Hugh J. Morris; Richard T. Hart; Xueliang Pan; Jun Liu
Investigative Ophthalmology & Visual Science | 2013
Hugh J. Morris; Benjamin Cruz Perez; Junhua Tang; Xueliang Pan; Richard T. Hart; Paul L. Weber; Jun Liu
Investigative Ophthalmology & Visual Science | 2014
Jun Liu; Hugh J. Morris; Hong Chen; Benjamin Cruz Perez; Richard T. Hart; Paul A. Weber
Investigative Ophthalmology & Visual Science | 2015
Joel R. Palko; Benjamin Cruz Perez; Jun Liu