Featured researches published by Bernhard Sattler.


European Journal of Nuclear Medicine and Molecular Imaging | 1997

Attenuation correction by simultaneous emission-transmission myocardial single-photon emission tomography using a technetium-99m-labelled radiotracer : impact on diagnostic accuracy

Regine Kluge; Bernhard Sattler; Anita Seese; Wolfram H. Knapp

Irregular photon attenuation may limit the diagnostic accuracy of myocardial single-photon emission tomography (SPET). The aim of this study was to quantify the potential benefit of attenuation correction by simultaneous emission and transmission imaging for the detection of coronary artery disease (CAD) of vessels supplying the inferoposterior wall segments. In 25 male patients with ≥50% stenoses of the right coronary artery and/or circumflex artery but without significant narrowing of the left anterior descending artery, stress studies using technetium-99m tetrofosmin (400 MBq) were carried out with and without attenuation correction. A dual-head camera with L-shaped detector positioning was equipped with two scanning gadolinium-153 line sources. Tomograms were reconstructed and quantified using circumferential count rate profiles of myocardial activity (two in each patient). The profiles were compared with the respective normal ranges obtained from a database of 25 male patients with a <10% likelihood of CAD. In patients without CAD, the maximal differences in count density of different wall segments were reduced from 29.0% in non-corrected (NC) studies to 9.5% in attenuation-corrected (AC) studies. In particular, the inferoposterior and septal wall segments were represented by significantly increased relative count densities after attenuation correction. The effects of attenuation correction proved independent of body mass. In patients with CAD, segmental count densities were abnormal in 84% of the NC studies and 100% of the AC studies. In single-vessel disease the stenotic vessel was identified in 66% of cases by NC studies and in 100% by AC studies. In AC studies, the extent and depth of defects exceeded those in NC studies. For the detection of CAD of the right coronary artery, the receiver operating characteristic (ROC) curves relating to the AC studies demonstrated improved discrimination capacity (P<0.05). ROC analysis of CAD detection yielded normalcy rates of 82% (NC) and 94% (AC) for the circumflex artery and 65% (NC) and 97% (AC) for the right coronary artery area at a sensitivity level of 95%. It is concluded that attenuation correction using the above system may enhance the diagnostic accuracy of myocardial SPET when inferoposterior wall segments are to be evaluated.


Pediatric Radiology | 2013

PET/MR in children. Initial clinical experience in paediatric oncology using an integrated PET/MR scanner

Franz Wolfgang Hirsch; Bernhard Sattler; Ina Sorge; Lars Kurch; Adrian Viehweger; Lutz Ritter; Peter Werner; Thies Jochimsen; Henryk Barthel; Uta Bierbach; Holger Till; Osama Sabri; Regine Kluge

Use of PET/MR in children has not previously been reported, to the best of our knowledge. Children with systemic malignancies may benefit from the reduced radiation exposure offered by PET/MR. We report our initial experience with PET/MR hybrid imaging and our current established sequence protocol after 21 PET/MR studies in 15 children with multifocal malignant diseases. The effective dose of a PET/MR scan was only about 20% that of the equivalent PET/CT examination. Simultaneous acquisition of PET and MR data combines the advantages of the two previously separate modalities. Furthermore, the technique also enables whole-body diffusion-weighted imaging (DWI) and statements to be made about the biological cellularity and nuclear/cytoplasmic ratio of tumours. Combined PET/MR saves time and resources. One disadvantage of PET/MR is that in order to have an effect, a significantly longer examination time is needed than with PET/CT. In our initial experience, PET/MR has turned out to be an unexpectedly stable and reliable hybrid imaging modality, which generates a complementary diagnostic study of great additional value.


Molecular Imaging and Biology | 2014

Combined PET/MR: Where Are We Now? Summary Report of the Second International Workshop on PET/MR Imaging April 8–12, 2013, Tubingen, Germany

Dale L. Bailey; Henryk Barthel; Bettina Beuthin-Baumann; Thomas Beyer; Sotirios Bisdas; Ronald Boellaard; Johannes Czernin; Alexander Drzezga; Ulrike Ernemann; Christiane Franzius; Brigitte Gückel; Rupert Handgretinger; Markus Hartenbach; Dirk Hellwig; Helen Nadel; Stephan G. Nekolla; Thomas Pfluger; Bernd J. Pichler; Harald H. Quick; Osama Sabri; Bernhard Sattler; Jürgen F. Schäfer; Fritz Schick; Barry A. Siegel; Heinz Peter Schlemmer; Nina F. Schwenzer; Jörg van den Hoff; Patrick Veit-Haibach

This workshop was held a year after the initial positron emission tomography/magnetic resonance (PET/MR) workshop in Tübingen, which was recently reported in this journal. The discussions at the 2013 workshop, however, differed substantially from those of the initial workshop, attesting to the progress of combined PET/MR as an innovative imaging modality. Discussions were focused on the search for truly novel, unique clinical and research applications as well as technical issues such as reliable and accurate approaches for attenuation and scatter correction of PET emission data. The workshop provided hands-on experience with PET and MR imaging. In addition, structured and moderated open discussion sessions, including six dialogue boards and two roundtable discussions, provided input from current and future PET/MR imaging users. This summary provides a snapshot of the current achievements and challenges for PET/MR.


European Journal of Nuclear Medicine and Molecular Imaging | 2017

EANM/EARL harmonization strategies in PET quantification: from daily practice to multicentre oncological studies

Nicolas Aide; Charline Lasnon; Patrick Veit-Haibach; Terez Sera; Bernhard Sattler; Ronald Boellaard

Quantitative positron emission tomography/computed tomography (PET/CT) can be used as diagnostic or prognostic tools (i.e. single measurement) or for therapy monitoring (i.e. longitudinal studies) in multicentre studies. Use of quantitative parameters, such as standardized uptake values (SUVs), metabolic active tumor volumes (MATVs) or total lesion glycolysis (TLG), in a multicenter setting requires that these parameters be comparable among patients and sites, regardless of the PET/CT system used. This review describes the motivations and the methodologies for quantitative PET/CT performance harmonization with emphasis on the EANM Research Ltd. (EARL) Fluorodeoxyglucose (FDG) PET/CT accreditation program, one of the international harmonization programs aiming at using FDG PET as a quantitative imaging biomarker. In addition, future accreditation initiatives will be discussed. The validation of the EARL accreditation program to harmonize SUVs and MATVs is described in a wide range of tumor types, with focus on therapy assessment using either the European Organization for Research and Treatment of Cancer (EORTC) criteria or PET Evaluation Response Criteria in Solid Tumors (PERCIST), as well as liver-based scales such as the Deauville score. Finally, also presented in this paper are the results from a survey across 51 EARL-accredited centers reporting how the program was implemented and its impact on daily routine and in clinical trials, harmonization of new metrics such as MATV and heterogeneity features.


European Journal of Nuclear Medicine and Molecular Imaging | 1997

Age-specific cerebral perfusion in 4- to 15-year-old children: a high-resolution brain SPET study using 99mTc-ECD.

Henryk Barthel; Michael Wiener; Claudia Dannenberg; Simone Bettin; Bernhard Sattler; Wolfram H. Knapp

Abstract.This study addresses the question of whether the normal range for distribution of local cerebral blood flow (lCBF) in adults can be transferred to the 4- to 15-year-old age group. Twenty-three children (age: 4–15 years; mean 11±3 years, group I) and 10 adults (age: 27–56 years; mean 45±10 years, group II) without evidence of cerebrovascular disease or other brain diseases underwent technetium-99m ethyl cysteinate dimer single-photon emission tomography. Counts in cortical and subcortical regions of interest (ROIs) were related to those in cerebellar ROIs (= 100%). Relative cortical activity in group I exceeded that in group II, particularly in left parietal (107.6%±9.8% vs 84.1%±12.4%), left frontal (97.7%±6.7% vs 79.4%±8.9%) and left temporal areas (99.7%±7.4% vs 84.9%±10.1%) and in the cingulate cortex (112.1%±9.1% vs 95.9%±10.1%, P<0.05). Cerebral activity uptake per injected dose was inversely correlated with age in 19 children of group I (r = –0.77, P<0.001). In group I, there was also an inverse correlation between age and the relative local count density in the parietal (r = –0.42 to –0.57), frontal (r = –0.48), temporal (r = –0.42 to –0.58) and occipital cortex (r = –0.44). In these cortical regions relative counts differed when subgroups of children aged 4–10 and 11–15 years were analysed. It is concluded that there are systematic differences between 4- to 15-year-old children and adults with regard to normal lCBF. Diagnostic use of perfusion agents has to consider age-adjusted normal flow maps; normal ranges should be determined separately for the age groups 4–10 and 11–15 years.


NeuroImage | 2015

First-in-human PET quantification study of cerebral α4β2* nicotinic acetylcholine receptors using the novel specific radioligand (−)-( 18 F)Flubatine☆

Osama Sabri; Georg-Alexander Becker; Philipp M. Meyer; Swen Hesse; Stephan Wilke; Susanne Graef; Marianne Patt; Julia Luthardt; Gudrun Wagenknecht; Alexander Hoepping; René Smits; Annegret Franke; Bernhard Sattler; Bernd Habermann; Petra Neuhaus; Steffen Fischer; Solveig Tiepolt; Winnie Deuther-Conrad; Henryk Barthel; Peter Schönknecht; Peter Brust

α4β2* nicotinic receptors (α4β2* nAChRs) could provide a biomarker in neuropsychiatric disorders (e.g., Alzheimers and Parkinsons diseases, depressive disorders, and nicotine addiction). However, there is a lack of α4β2* nAChR specific PET radioligands with kinetics fast enough to enable quantification of nAChR within a reasonable time frame. Following on from promising preclinical results, the aim of the present study was to evaluate for the first time in humans the novel PET radioligand (-)-[(18)F]Flubatine, formerly known as (-)-[(18)F]NCFHEB, as a tool for α4β2* nAChR imaging and in vivo quantification. Dynamic PET emission recordings lasting 270min were acquired on an ECAT EXACT HR+ scanner in 12 healthy male non-smoking subjects (71.0±5.0years) following the intravenous injection of 353.7±9.4MBq of (-)-[(18)F]Flubatine. Individual magnetic resonance imaging (MRI) was performed for co-registration. PET frames were motion-corrected, before the kinetics in 29 brain regions were characterized using 1- and 2-tissue compartment models (1TCM, 2TCM). Given the low amounts of metabolite present in plasma, we tested arterial input functions with and without metabolite corrections. In addition, pixel-based graphical analysis (Logan plot) was used. The models goodness of fit, with and without metabolite correction was assessed by Akaikes information criterion. Model parameters of interest were the total distribution volume VT (mL/cm(3)), and the binding potential BPND relative to the corpus callosum, which served as a reference region. The tracer proved to have high stability in vivo, with 90% of the plasma radioactivity remaining as untransformed parent compound at 90min, fast brain kinetics with rapid uptake and equilibration between free and receptor-bound tracer. Adequate fits of brain TACs were obtained with the 1TCM. VT could be reliably estimated within 90min for all regions investigated, and within 30min for low-binding regions such as the cerebral cortex. The rank order of VT by region corresponded well with the known distribution of α4β2* receptors (VT [thalamus] 27.4±3.8, VT [putamen] 12.7±0.9, VT [frontal cortex] 10.0±0.8, and VT [corpus callosum] 6.3±0.8). The BPND, which is a parameter of α4β2* nAChR availability, was 3.41±0.79 for the thalamus, 1.04±0.25 for the putamen and 0.61±0.23 for the frontal cortex, indicating high specific tracer binding. Use of the arterial input function without metabolite correction resulted in a 10% underestimation in VT, and was without important biasing effects on BPND. Altogether, kinetics and imaging properties of (-)-[(18)F]Flubatine appear favorable and suggest that (-)-[(18)F]Flubatine is a very suitable and clinically applicable PET tracer for in vivo imaging of α4β2* nAChRs in neuropsychiatric disorders.


Journal of Cerebral Blood Flow and Metabolism | 2015

Simultaneous PET/Mri in Stroke: A Case Series

Peter Werner; Dorothee Saur; Vilia Zeisig; Barbara Ettrich; Marianne Patt; Bernhard Sattler; Thies Jochimsen; Donald Lobsien; Philipp M. Meyer; Florian Then Bergh; Antje Y. Dreyer; Johannes Boltze; Joseph Classen; Dominik Fritzsch; Karl-Titus Hoffmann; Osama Sabri; Henryk Barthel

Prospective studies on magnetic resonance imaging (MRI)-guided systemic thrombolysis 44.5 hours after stroke onset did not reach their primary end points. It was discussed and observed in post hoc data re-assessment that this was partly because of limited MRI accuracy to measure critical hypoperfusion. We report the first cases of simultaneous [15O]H2O-positron emission tomography (PET)/MRI in stroke patients and an ovine model. Discrepancies between simultaneously obtained PET and MRI readouts were observed that might explain the above current limitations of stroke MRI. By offering highly complementary information, [15O]H2O-PET/MRI might help to identify critically hypoperfused tissue resulting in an improved patient stratification in thrombolysis trials.


Medical Physics | 2015

Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems

Ronald Boellaard; Ivo Rausch; Thomas Beyer; Gaspar Delso; Maqsood Yaqub; Harald H. Quick; Bernhard Sattler

PURPOSE Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. METHODS The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. RESULTS Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to -8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. CONCLUSIONS Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.


EJNMMI Physics | 2016

Fully automated calculation of image-derived input function in simultaneous PET/MRI in a sheep model

Thies Jochimsen; Vilia Zeisig; Jessica Schulz; Peter Werner; Marianne Patt; Jörg Patt; Antje Y. Dreyer; Johannes Boltze; Henryk Barthel; Osama Sabri; Bernhard Sattler

BackgroundObtaining the arterial input function (AIF) from image data in dynamic positron emission tomography (PET) examinations is a non-invasive alternative to arterial blood sampling. In simultaneous PET/magnetic resonance imaging (PET/MRI), high-resolution MRI angiographies can be used to define major arteries for correction of partial-volume effects (PVE) and point spread function (PSF) response in the PET data. The present study describes a fully automated method to obtain the image-derived input function (IDIF) in PET/MRI. Results are compared to those obtained by arterial blood sampling.MethodsTo segment the trunk of the major arteries in the neck, a high-resolution time-of-flight MRI angiography was postprocessed by a vessel-enhancement filter based on the inertia tensor. Together with the measured PSF of the PET subsystem, the arterial mask was used for geometrical deconvolution, yielding the time-resolved activity concentration averaged over a major artery. The method was compared to manual arterial blood sampling at the hind leg of 21 sheep (animal stroke model) during measurement of blood flow with O15-water. Absolute quantification of activity concentration was compared after bolus passage during steady state, i.e., between 2.5- and 5-min post injection. Cerebral blood flow (CBF) values from blood sampling and IDIF were also compared.ResultsThe cross-calibration factor obtained by comparing activity concentrations in blood samples and IDIF during steady state is 0.98 ± 0.10. In all examinations, the IDIF provided a much earlier and sharper bolus peak than in the time course of activity concentration obtained by arterial blood sampling. CBF using the IDIF was 22 % higher than CBF obtained by using the AIF yielded by blood sampling.ConclusionsThe small deviation between arterial blood sampling and IDIF during steady state indicates that correction of PVE and PSF is possible with the method presented. The differences in bolus dynamics and, hence, CBF values can be explained by the different sampling locations (hind leg vs. major neck arteries) with differences in delay/dispersion. It will be the topic of further work to test the method on humans with the perspective of replacing invasive blood sampling by an IDIF using simultaneous PET/MRI.


Molecular Imaging and Biology | 2018

Combined PET/MRI: Global Warming—Summary Report of the 6th International Workshop on PET/MRI, March 27–29, 2017, Tübingen, Germany

Dale L. Bailey; Bernd J. Pichler; Brigitte Gückel; Gerald Antoch; Henryk Barthel; Z. M. Bhujwalla; Saskia Biskup; Sandip Biswal; M. Bitzer; Ronald Boellaard; R. F. Braren; Cornelia Brendle; Kevin M. Brindle; Arturo Chiti; C. la Fougère; Robert J. Gillies; Vicky Goh; M. Goyen; Marcus Hacker; L. Heukamp; Gitte M. Knudsen; A. M. Krackhardt; Ian Law; John C. Morris; Konstantin Nikolaou; Johan Nuyts; Alvaro A. Ordonez; K. Pantel; Harald H. Quick; Katrine Riklund

The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants critically assessed the current state of PET/MRI, both clinically and as a research tool, and attempted to chart future directions. The meeting addressed the use of PET/MRI and workflows in oncology, neurosciences, infection, inflammation and chronic pain syndromes, as well as deeper discussions about how best to characterise the tumour microenvironment, optimise the complementary information available from PET and MRI, and how advanced data mining and bioinformatics, as well as information from liquid biomarkers (circulating tumour cells and nucleic acids) and pathology, can be integrated to give a more complete characterisation of disease phenotype. Some issues that have dominated previous meetings, such as the accuracy of MR-based attenuation correction (AC) of the PET scan, were finally put to rest as having been adequately addressed for the majority of clinical situations. Likewise, the ability to standardise PET systems for use in multicentre trials was confirmed, thus removing a perceived barrier to larger clinical imaging trials. The meeting openly questioned whether PET/MRI should, in all cases, be used as a whole-body imaging modality or whether in many circumstances it would best be employed to give an in-depth study of previously identified disease in a single organ or region. The meeting concluded that there is still much work to be done in the integration of data from different fields and in developing a common language for all stakeholders involved. In addition, the participants advocated joint training and education for individuals who engage in routine PET/MRI. It was agreed that PET/MRI can enhance our understanding of normal and disrupted biology, and we are in a position to describe the in vivo nature of disease processes, metabolism, evolution of cancer and the monitoring of response to pharmacological interventions and therapies. As such, PET/MRI is a key to advancing medicine and patient care.

Collaboration


Dive into the Bernhard Sattler's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peter Brust

Schiller International University

View shared research outputs
Top Co-Authors

Avatar

Winnie Deuther-Conrad

Helmholtz-Zentrum Dresden-Rossendorf

View shared research outputs
Top Co-Authors

Avatar

Mathias Kranz

Helmholtz-Zentrum Dresden-Rossendorf

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Steffen Fischer

Helmholtz-Zentrum Dresden-Rossendorf

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge