Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Bi-Yi Xu is active.

Publication


Featured researches published by Bi-Yi Xu.


Biosensors and Bioelectronics | 2013

Simultaneous electrochemical immunoassay using CdS/DNA and PbS/DNA nanochains as labels

Fen-Ying Kong; Bi-Yi Xu; Jing-Juan Xu; Hong-Yuan Chen

An electrochemical method for the simultaneous detection of two different tumor markers, carcinoembryonic antigen (CEA) and α-fetoprotein (AFP), in one-pot, using CdS/DNA and PbS/DNA nanochains as labels was developed. Herein, magnetic beads (MBs) as bimolecule immobilizing carriers, were used for co-immobilization of primary anti-CEA and anti-AFP antibodies. The distinguishable signal labels were synthesized by in situ growth of CdS and PbS nanoparticles on DNA chains, respectively, which were further employed to label the corresponding secondary antibodies. A sandwich-type immunoassay format was formed by the biorecognition of the antigens and corresponding antibodies. The assay was based on the peak currents of Cd(2+) and Pb(2+) dissolved from CdS and PbS nanoparticles by HNO(3) using square wave stripping voltammetry. Experimental results show that the multiplexed electrochemical immunoassay has enabled the simultaneous monitoring of CEA and AFP in a single run with wide working ranges of 0.1-100ng mL(-1) for CEA and 0.5-200ng mL(-1) for AFP. The detection limits reach to 3.3pg mL(-1) for CEA and 7.8pg mL(-1) for AFP.


Lab on a Chip | 2013

A novel microfluidic platform with stable concentration gradient for on chip cell culture and screening assays.

Bi-Yi Xu; Shan-Wen Hu; Guang-Sheng Qian; Jing-Juan Xu; Hong-Yuan Chen

In this work a novel microfluidic platform for cell culture and assay is developed. On the chip a static cell culture region is coupled with dynamic fluidic nutrition supply structures. The cell culture unit has a sandwich structure with liquid channels on the top, the cell culture reservoir in the middle and gas channels on the bottom. Samples can be easily loaded into the reservoir and exchange constantly with the external liquid environment by diffusion. Since the flow direction is perpendicular to the liquid channel on the top of the reservoir, the cells in the reservoir are shielded from shear-force. By assembling the basic units into an array, a steady concentration gradient can be generated. Cell culture models both for continuous perfusion and one-off perfusion were established on the chip. Both adherent and suspended cells were successfully cultured on the chip in 2D and 3D culture modes. After culturing, the trapped cells were recovered for use in a later assay. As a competitive candidate for a standard cell culture and assay platform, this chip is also adaptable for cytotoxicity and cell growth assays.


ACS Applied Materials & Interfaces | 2015

Versatile Microfluidic Droplets Array for Bioanalysis

Shan-Wen Hu; Bi-Yi Xu; Wei-ke Ye; Xing-Hua Xia; Hong-Yuan Chen; Jing-Juan Xu

We propose a novel method to obtain versatile droplets arrays on a regional hydrophilic chip that is fabricated by PDMS soft lithography and regional plasma treatment. It enables rapid liquid dispensation and droplets array formation just making the chip surface in contact with solution. By combining this chip with a special Christmas Tree structure, the droplets array with concentrations in gradient is generated. It possesses the greatly improved performance of convenience and versatility in bioscreening and biosensing. For example, high throughput condition screening of toxic tests of CdSe quantum dots on HL-60 cells are conducted and cell death rates are successfully counted quickly and efficiently. Furthermore, a rapid biosensing approach for cancer biomarkers carcinoma embryonic antigen (CEA) is developed via magnetic beads (MBs)-based sandwich immunoassay methods.


Analytical Chemistry | 2017

Dual-Functional Carbon Dots Pattern on Paper Chips for Fe3+ and Ferritin Analysis in Whole Blood

Shan-Wen Hu; Shu Qiao; Bi-Yi Xu; Xiang Peng; Jing-Juan Xu; Hong-Yuan Chen

Though microfluidic paper analytical devices (μPADs) have attracted paramounting attentions in recent years as promising devices for low cost point-of-care tests, their real applications for blood analysis are still challenged by integrating sample preparation with different detection modes on a same μPAD. Herein, we developed a novel μPAD, which well coupled automatic serum extraction with reliable dual mode iron health tests: fluorescent analysis for Fe3+ and colorimetric ELISA for ferritin. All these functions are made available by in situ carbon dots (CDs) and AuNPs sequential patterning techniques. For CDs immobilization, hydrothermal reaction was taken on paper, to which a patterned through-hole polydimethylsiloxane (PDMS) mask was applied. None fluorescence CDs (nF-CDs) were generated on exposed regions, while the fluorescent CDs (F-CDs) were generated simultaneously on covered regions. Sensitive serum iron quantification was realized on the F-CDs modified regions, where Fe3+ ion can selectively quench the fluorescence of F-CDs. For AuNPs immobilization, electroless plating was taken on nF-CDs modified regions. The resulting AuNPs on nF-CDs layer on one hand triggered the coagulation of blood cells and thus led to the longest ever wicking distance for serum separation, on the other hand facilitated colorimetric enzyme linked immunosorbent assay (ELISA) for detection of serum ferritin. Combining the two readings, the μPAD can provide reliable measurement for serum iron and serum ferritin in whole blood. Furthermore, as CDs and AuNPs modified μPAD has the features of easy handling, low-cost, lightweight, and disposability, it is accounting for a promising prototype for whole blood point-of-care analysis.


Lab on a Chip | 2012

On chip steady liquid-gas phase separation for flexible generation of dissolved gas concentration gradient.

Bi-Yi Xu; Shan-Wen Hu; Xiao-Na Yan; Xing-Hua Xia; Jing-Juan Xu; Hong-Yuan Chen

In this study, steady liquid-gas phase separation is realized by applying a hydrophobic small microchannel array (SMA) to bridge two large microchannels, one for liquid phase and one for gas phase. In this structure, a capillary pressure difference between that in the SMA and the larger channel results in a steady liquid-gas interface. The generated liquid-gas interface allows for fast gas dissolving speed. By coupling the liquid-gas interface with a one directional fluidic field, a steady dissolved gas concentration gradient (DgCG) is generated. The DgCG distribution is easily designable for linear or exponential modes, providing improved flexibility for gas participated processes on chip. To demonstrate its applicability, a CO(2) DgCG chip is fabricated and applied for screening CaCO(3) crystal growth conditions in the DgCG chip. Crystals with transitional structures are successfully fabricated, which is consistent with the CO(2) DgCG distribution.


Biomicrofluidics | 2012

One step high quality poly(dimethylsiloxane)-hydrocarbon plastics bonding

Bi-Yi Xu; Xiao-Na Yan; Jing-Juan Xu; Hong-Yuan Chen

In this paper, one-step air plasma treatment is successfully used for poly(dimethylsiloxane)(PDMS)-plastic chip bonding. The technique is green, cheap, and requires no other reagent other than air. Hydrocarbon plastics: polystyrene (PS), cyclic olefin copolymer (COC), and polypropylene (PP) have all been successfully bonded to PDMS irreversibly. The corresponding compressed air resistances are measured to be around 500 kPa for PDMS-PS, PDMS-COC, and PDMS-PP hybrid chips. The bondings are also of good quality even after storage under different temperatures and subject to solutions from acid to base.


Lab on a Chip | 2017

Microfluidic PDMS on paper (POP) devices

Jin-Wen Shangguan; Yu Liu; Jian-Bin Pan; Bi-Yi Xu; Jing-Juan Xu; Hong-Yuan Chen

In this paper, we propose a generalized concept of microfluidic polydimethylsiloxane (PDMS) on paper (POP) devices, which combines well the merits of paper chips and PDMS chips. First, we optimized the conditions for accurate PDMS spatial patterning on paper, based on screen printing and a high temperature enabled superfast curing technique, which enables PDMS patterning to an accuracy of tens of microns in less than ten seconds. This, in turn, makes it available for seamless, reversible and reliable integration of the resulting paper layer with other PDMS channel structures. The integrated POP devices allow for both porous paper and smooth channels to be spatially defined on the devices, greatly extending the flexibility for designers to be able to construct powerful functional structures. To demonstrate the versatility of this design, a prototype POP device for the colorimetric analysis of liver function markers, serum protein, alkaline phosphatase (ALP) and aspartate aminotransferase (AST), was constructed. On this POP device, quantitative sample loading, mixing and multiplex analysis have all been realized.


Biomicrofluidics | 2013

Liquid gradient in two-dimensional matrix for high throughput screening

Shan-Wen Hu; Bi-Yi Xu; Jing-Juan Xu; Hong-Yuan Chen

Based on the ingenious combination of two different gradient generation mechanisms, this work reports a novel approach for a high throughput linear liquid gradient in a two-dimensional (2D) matrix. Specifically, a typical Christmas Tree structure with two inlets was designed as the first mixture gradient generator, upon which the second diffusion gradient generator was coupled to produce the desired concentration series on the basis of the distance difference. Rather than a simple 1D line, the integration of the two generators would result in an innovative 2D matrix of reservoirs, which was then characterized both theoretically and experimentally. Theoretically, calculation of fluid field demonstrated the formation of a concentration gradient, which was then confirmed by the dye solution visualization analysis. For high throughput screening application, doxorubicin (Dox) was then selected as model medicine to treat the acute myeloblastic leukemia (HL-60) cells. Cell viability displayed that cell death rate enhanced with the increase of drug concentration, and this result was higher than that on a 96-well plate, and the corresponding mechanism was properly discussed. Subsequently, Dox and quercetin were employed simultaneously to generate an overlapping gradient and its effect on HL-60 cells was investigated. Due to the automatic formation of concentration gradient that could improve the work efficiency, this work provides a promising tool for future high throughput drug screening.


Talanta | 2016

A microfluidic cigarette smoke collecting platform for simultaneous sample extraction and multiplex analysis.

Shan-Wen Hu; Bi-Yi Xu; Shu Qiao; Ge Zhao; Jing-Juan Xu; Hong-Yuan Chen; Fu-Wei Xie

In this work, we report a novel microfluidic gas collecting platform aiming at simultaneous sample extraction and multiplex mass spectrometry (MS) analysis. An alveolar-mimicking elastic polydimethylsiloxane (PDMS) structures was designed to move dynamically driven by external pressure. The movement was well tuned both by its amplitude and rhythm following the natural process of human respiration. By integrating the alveolar units into arrays and assembling them to gas channels, a cyclic contraction/expansion system for gas inhale and exhale was successfully constructed. Upon equipping this system with a droplet array on the alveolar array surface, we were able to get information of inhaled smoke in a new strategy. Here, with cigarette smoke as an example, analysis of accumulation for target molecules during passive smoking is taken. Relationships between the breathing times, distances away from smokers and inhaled content of nicotine are clarified. Further, by applying different types of extraction solvent droplets on different locations of the droplet array, simultaneous extraction of nicotine, formaldehyde and caproic acid in sidestream smoke (SS) are realized. Since the extract droplets are spatially separated, they can be directly analyzed by MS which is fast and can rid us of all complex sample separation and purification steps. Combining all these merits, this small, cheap and portable platform might find wide application in inhaled air pollutant analysis both in and outdoors.


Talanta | 2018

Microfluidic liquid-air dual-gradient chip for synergic effect bio-evaluation of air pollutant

Xianjun Liu; Shan-Wen Hu; Bi-Yi Xu; Ge Zhao; Xiang Li; Fuwei Xie; Jing-Juan Xu; Hong-Yuan Chen

In this paper, a novel prototype liquid-air dual gradient chip is introduced, which has paved the way for effective synergic effect bio-evaluation of air pollutant. The chip is composed of an array of the agarose liquid-air interfaces, top air gradient layer and bottom liquid gradient layer. The novel agarose liquid-air interface allows for non-biased exposure of cells to all the substances in the air and diffusive interactions with the liquid phase; while the dual liquid-air gradient provides powerful screening abilities, which well reduced errors, saved time and cost from repeated experiment. Coupling the two functions, the chip subsequently facilitates synergic effect evaluation of both liquid and air factors on cells. Here cigarette smoke was taken as the model air pollutant, and its strong synergic effects with inflammatory level of A549 lung cancer cells on their fate were successfully quantified for the first time. These results well testified that the proposed dual-gradient chip is powerful and indispensable for bio-evaluation of air pollutant.

Collaboration


Dive into the Bi-Yi Xu's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge