Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Cacio Moura-Netto is active.

Publication


Featured researches published by Cacio Moura-Netto.


Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology | 2009

Comparison of different irrigants on calcium hydroxide medication removal: microscopic cleanliness evaluation

Ricardo Julio Cabrales Salgado; Cacio Moura-Netto; Andrea Kanako Yamazaki; Luciano Natividade Cardoso; Abílio Albuquerque Maranhão de Moura; Igor Prokopowitsch

Calcium hydroxide dressing residuals can compromise endodontic sealing. This study evaluated the cleaning efficacy of different endodontic irrigants in removing calcium hydroxide by SEM image analysis. Fifty-four single-rooted mandibular premolars were instrumented to a master apical file #60 and dressed with calcium hydroxide. After 36 hours, the teeth were reopened and Ca(OH)(2) medication was removed by 5 different experimental groups: 0.5% NaOCl (G1), EDTA-C (G2), citric acid (G3), EDTA-T (G4), and re-instrumentation with MAF using NaOCl and lubrificant, followed by EDTA-T (G5). The roots were split in the buccal-lingual direction and prepared for SEM analysis in cervical, middle, and apical thirds (9, 6, and 3mm from the apex). Five blinded examiners evaluated the wall cleanliness using a scale from 1 to 5. Statistical analysis was performed using Kruskal-Wallis at 5% level of significance. Group G5 had the best results in all thirds, with significant statistical differences compared to all other groups in the middle and coronal third, and to G1 in the apical third. On the other hand, G1, only flushed with NaOCl, had the worst results, with statistical differences in all thirds compared to the other groups. The best cleanliness was achieved by G4 and G5 groups. The recapitulation of MAF in combination with irrigants improved the removal of calcium hydroxide medication better than an irrigant flush alone.


Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology | 2011

Accuracy of working length determination using 3 electronic apex locators and direct digital radiography.

Denis Gonçalves Real; Harry Davidowicz; Cacio Moura-Netto; Clacir de Lourdes Londero Zenkner; Claudia Medianeira Londero Pagliarin; Fernando Branco Barletta; Abílio Albuquerque Maranhão de Moura

OBJECTIVES The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). STUDY DESIGN Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of ±1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the χ(2) tests. RESULTS Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of ±1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. CONCLUSIONS Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography.


Photomedicine and Laser Surgery | 2008

Morphologic changes and removal of debris on apical dentin surfaces after Nd:YAG laser and diode laser irradiation.

Cacio Moura-Netto; Abílio Albuquerque Maranhão de Moura; Harry Davidowicz; Carlos Eduardo Aun; Miriam Porcel do Santos Antonio

OBJECTIVE To verify the effects of laser energy on intracanal dentin surfaces, by analyzing the morphologic changes and removal of debris in the apical third of 30 extracted human teeth, prepared and irradiated with the Nd:YAG laser and diode laser. BACKGROUND DATA Lasers have been widely used in endodontics. The morphologic changes in dentin walls caused by Nd:YAG and diode laser irradiation could improve apical seals and cleanliness. MATERIALS AND METHODS The protocol used for Nd:YAG laser irradiation was 1.5 W, 100 mJ, and 15 Hz, in pulsed mode, and for diode laser was 2.5 W in continuous mode. Each specimen was irradiated four times at a speed of 2 mm/sec with a 20-sec interval between applications. Five calibrated examiners scored the morphologic changes and debris removal on a 4-point scale. RESULTS In analyzing the scores, there were no statistically significant differences between the two types of laser for either parameter, according to Kruskal-Wallis testing at p = 0.05. The SEM images showed fusion and resolidification of the dentin surface, with partial removal of debris on the specimens irradiated with the Nd:YAG laser and the diode laser, compared with controls. CONCLUSION Both lasers promote morphologic changes and debris removal. These alterations of the dentin surface appeared to be more evident in the Nd:YAG laser group, but the diode laser group showed more uniform changes.


Brazilian Dental Journal | 2011

Nd:YAG Laser Irradiation Effect on Apical Intracanal Dentin - A Microleakage and SEM Evaluation

Cacio Moura-Netto; Camila de Almeida Brandão Guglielmi; Anna Carolina Volpi Mello-Moura; Renato Miotto Palo; Daniela Prócida Raggio; Celso Luiz Caldeira

The purpose of this in vitro study was to evaluate the effect of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser irradiation on intracanal dentin surface by SEM analysis and its interference in the apical seal of filled canals. After endodontic treatment procedures, 34 maxillary human incisors were randomly assigned to 2 groups. In the negative control group (n=17), no additional treatment was performed and teeth were filled with vertically condensed gutta-percha; in the laser-treated group (n=17), the root canals were irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz) before filling as described for the control group. Two specimens of each group were prepared for SEM analysis to evaluate the presence and extent of morphological changes and removal of debris; the other specimens were immersed in 0.5% methylene blue dye (pH 7.2) for 24 h for evaluation of the linear dye leakage at the apical third. SEM analysis of the laser-treated group showed dentin fusion and resolidification without smear layer or debris. The Students t-test showed that the laser-treated group had significantly less leakage in apical third than the control group. Within the limitations of this study, it may be concluded that the morphological changes on the apical intraradicular dentin surface caused by Nd:YAG laser resulted in less linear dye apical leakage.


Brazilian Oral Research | 2010

In vitro analysis of thermocompaction time and gutta-percha type on quality of main canal and lateral canals filling

André Luiz da Costa Michelotto; Cacio Moura-Netto; Ângela Toshie Araki; Eduardo Akisue; Abílio Albuquerque Maranhão de Moura; Gilson Blitzkow Sydney

The aim of this study was to evaluate the quality of filling in main and lateral root canals performed with the McSpadden technique, regarding the time spent on the procedure and the type of gutta-percha employed. Fifty simulated root canals, made with six lateral canals placed two apiece in the cervical, middle and apical thirds of the root, were divided into 5 groups. Group A: McSpadden technique with conventional gutta-percha, performed with sufficient time for canal filling; Group B: McSpadden technique with conventional gutta-percha, performed in twice the mean time used in Group A; Group C: McSpadden technique with TP gutta-percha, performed with sufficient time for canal filling; Group D: McSpadden technique with TP gutta-percha, performed in twice the mean time used in Group C; Group E: lateral condensation technique. Images of the filled root canals were taken using a stereomicroscope and analyzed using the Leica QWIN Pro software for filling material flow, gutta-percha filling extension and sealer flow. Data were analyzed by analysis of variance (ANOVA) and Tukey test (p < 0.05). The best values of penetration in lateral canals in the middle third occurred in the groups where TP gutta-percha was used. However, in the apical third, group B showed the best values. Although a longer time of compactor use allows greater penetration of the filling material into the lateral canals, the presence of voids resulted in bad quality radiographic images, suggesting porosity. The best quality of filling material was observed in Group A (McSpadden technique with conventional Gutta-Percha, performed with sufficient time for root canal filling).


Brazilian Oral Research | 2010

Accuracy of three electronic apex locators in the presence of different irrigating solutions

Ana Laura Pion de Carvalho; Cacio Moura-Netto; Abílio Albuquerque Maranhão de Moura; Márcia Martins Marques; Harry Davidowicz

The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9% saline solution and 1% sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p > 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.


Brazilian Oral Research | 2013

Micro-CT assessment of two different endodontic preparation systems

Cacio Moura-Netto; Renato Miotto Palo; Carlos Henrique Ribeiro Camargo; Cornelis H. Pameijer; Márcia Regina Ramalho da Silva Bardauil

The aim of this study was to compare two endodontic preparation systems using micro-CT analysis. Twenty-four one-rooted mandibular premolars were selected and randomly assigned to two groups. The samples (n = 12) of Group 1 were prepared using the ProTaper Universal rotary system, while Group 2 (n = 12) was prepared using the EndoEZE AET system complemented by manual apical preparation with K-type hand files up to #30. A 2.5% sodium hypochlorite solution was used in both groups for irrigating. Both groups were scanned by high-resolution microcomputed tomography before and after preparation (SkyScan 1172, SkyScan, Kontich, Belgium). The root canal volume and surface area was measured before and after preparation, and the differences were calculated and analyzed for statistically significant differences using ANOVA complemented by the Tukey test (p < 0.05). The results showed no statistically significant differences between the mean volumes of dentin removal by the two systems. However, the EndoEZE AET system presented a significantly greater mean surface area compared to the ProTaper system (p < 0.05). The EndoEZE AET system enabled preparation of a greater root canal surface area when compared to the ProTaper Universal system. There seemed to be no difference in dentin volume loss between the two systems used.


Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology | 2010

Morphological assessment of dentine and cementum following apicectomy with Zekrya burs and Er:YAG laser associated with direct and indirect Nd:YAG laser irradiation

Abílio Albuquerque Maranhão de Moura; Cacio Moura-Netto; Fernando Branco Barletta; Nilson Dias Vieira-Júnior; Carlos de Paula Eduardo

OBJECTIVES This study aimed to assess the apical surface morphology of maxillary central incisors resected 3.0 mm from the tooth apex using Zekrya burs or Er:YAG laser, with or without subsequent direct Nd:YAG laser irradiation (apical and buccal surfaces) and indirect irradiation (palatal surface). STUDY DESIGN Forty maxillary central incisors were instrumented and obturated. The roots were divided into 4 groups according to the root resection method (Zekrya bur or Er:YAG laser - 1.8 W, 450 mJ, 4 Hz, 113 J/cm(2)) and further surface treatment (none or Nd:YAG laser - 2.0 W, 100 mJ, 20 Hz, 124 J/cm(2)). The teeth were prepared for SEM analysis. Scores ranging from 1 to 4 were attributed to cut quality and morphological changes. The data were analyzed by the Kruskal-Wallis test and by Dunns test. RESULTS SEM images showed irregular surfaces on the apical portions resected with Zekrya burs, with smear layer and grooves in the resected dentine and slight gutta-percha displacement and plasticization. On the other hand, apicectomies carried out with Er:YAG laser showed morphological changes compatible with ablated dentine, with rough surfaces and craters. In spite of the presence of plasticized gutta-percha, with the presence of bubbles, an irregular adaptation of the filling material to the root walls was also observed. Direct Nd:YAG laser irradiation of the apical and buccal surfaces of the resected roots resulted in areas of resolidification and fusion in the dentine and cementum, with a vitrified aspect; indirect Nd:YAG laser irradiation of the palatal surfaces yielded a lower number of changes in the cementum, with irregular resolidification areas. CONCLUSIONS There were no differences in terms of cut quality between the use of burs and Er:YAG laser or between the 2 surfaces (apical and buccal) treated with Nd:YAG laser with direct irradiation. However, morphological changes were significantly less frequent on surfaces submitted to indirect irradiation (palatal) when compared with those directly irradiated.


Brazilian Oral Research | 2015

Changes in irradiance and energy density in relation to different curing distances

Rafael Silva Beolchi; Cacio Moura-Netto; Renato Miotto Palo; Carlos Rocha Gomes Torres; Bruno Pelissier

The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm(2) of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukeys tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm(2) (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm(2) at all curing distances.


Photomedicine and Laser Surgery | 2009

Apical Leakage of Three Resin-Based Endodontic Sealers after 810-nm-Diode Laser Irradiation

Cacio Moura-Netto; Tiago Pinto; Harry Davidowicz; Abílio Albuquerque Maranhão de Moura

OBJECTIVE To evaluate the influence of 810-nm-diode laser irradiation, applied before root canal filling, on apical sealing ability of three different resin-based sealers (AH Plus, EndoRez, and RealSeal). BACKGROUND Lasers have been widely used in endodontics. The dentin wall changes caused by laser irradiation could improve the sealing ability of endodontic cements. METHODS Sixty single-rooted human teeth were divided into six groups, according to the endodontic sealer used and previous 810-nm-diode laser irradiation. The protocol for laser irradiation was 2.5 W in a continuous wave, in scanning mode, with four irradiations per tooth. After sample preparation, they were analyzed according to apical leakage with silver nitrate impregnation. RESULTS The RealSeal sealer achieved minimum leakage rates (1.24 mm), with significant differences at the 1% level (Tukeys test, p<0.01) from AH Plus (1.84 mm) in nonirradiated groups. When the laser was used, there were also significant differences at the 5% level (p<0.05) between irradiated groups (1.31 and 1.78 mm, respectively). CONCLUSION The 810-nm-diode laser irradiation did not promote significant differences in apical leakage.

Collaboration


Dive into the Cacio Moura-Netto's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Eduardo Akisue

University of São Paulo

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge