Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Carina Reble is active.

Publication


Featured researches published by Carina Reble.


Biomedical Optics Express | 2011

Influence of tissue absorption and scattering on the depth dependent sensitivity of Raman fiber probes investigated by Monte Carlo simulations

Carina Reble; Ingo Gersonde; Chad A. Lieber; Jürgen Helfmann

We present a Monte Carlo model, which we use to calculate the depth dependent sensitivity or sampling volume of different single fiber and multi-fiber Raman probes. A two-layer skin model is employed to investigate the dependency of the sampling volume on the absorption and reduced scattering coefficients in the near infrared wavelength range (NIR). The shape of the sampling volume is mainly determined by the scattering coefficient and the wavelength dependency of absorption and scattering has only a small effect on the sampling volume of a typical fingerprint spectrum. An increase in the sampling depth in nonmelanoma skin cancer, compared to normal skin, is obtained.


Experimental Dermatology | 2015

In vivo study for the discrimination of cancerous and normal skin using fibre probe-based Raman spectroscopy.

Johannes Schleusener; Patrycja Gluszczynska; Carina Reble; Ingo Gersonde; Jürgen Helfmann; Joachim W. Fluhr; Jürgen Lademann; Joachim Röwert-Huber; Alexa Patzelt; Martina C. Meinke

Raman spectroscopy has proved its capability as an objective, non‐invasive tool for the detection of various melanoma and non‐melanoma skin cancers (NMSC) in a number of studies. Most publications are based on a Raman microspectroscopic ex vivo approach. In this in vivo clinical evaluation, we apply Raman spectroscopy using a fibre‐coupled probe that allows access to a multitude of affected body sites. The probe design is optimized for epithelial sensitivity, whereby a large part of the detected signal originates from within the epidermal layers depth down to the basal membrane where early stages of skin cancer develop. Data analysis was performed on measurements of 104 subjects scheduled for excision of lesions suspected of being malignant melanoma (MM) (n = 36), basal cell carcinoma (BCC) (n = 39) and squamous cell carcinoma (SCC) (n = 29). NMSC were discriminated from normal skin with a balanced accuracy of 73% (BCC) and 85% (SCC) using partial least squares discriminant analysis (PLS‐DA). Discriminating MM and pigmented nevi (PN) resulted in a balanced accuracy of 91%. These results lie within the range of comparable in vivo studies and the accuracies achieved by trained dermatologists using dermoscopy. Discrimination proved to be unsuccessful between cancerous lesions and suspicious lesions that had been histopathologically verified as benign by dermoscopy.


Applied Spectroscopy | 2015

Perturbation Factors in the Clinical Handling of a Fiber-Coupled Raman Probe for Cutaneous in Vivo Diagnostic Raman Spectroscopy:

Johannes Schleusener; Patrycja Gluszczynska; Carina Reble; Ingo Gersonde; Jürgen Helfmann; Hans-Joachim Cappius; Joachim W. Fluhr; Martina C. Meinke

The application of fiber-coupled Raman probes for the discrimination of cancerous and normal skin has the advantage of a noninvasive in vivo application, easy clinical handling, and access to the majority of body sites, which would otherwise be limited by stationary Raman microscopes. Nevertheless, including optical fibers and miniaturizing optical components, as well as measuring in vivo, involves the sensibility to external perturbation factors that could introduce artifacts to the acquired Raman spectra and thereby potentially reduce classification performance. In this study, typical perturbation factors of Raman measurements with a Raman fiber probe, optimized for clinical in vivo discrimination of skin cancer, were investigated experimentally. Measurements were performed under standardized conditions in clinical settings in vivo on human skin, as well as ex vivo on porcine ears. Raman spectra were analyzed in the fingerprint region between 1150 and 1730 cm−1 using principal component analysis. The largest artifacts in the Raman spectra were found in measurements performed under the influence of strong ambient light conditions as well as after miscellaneous pre-treatments to the skin, such as use of a permanent marker or a sunscreen. Minor influences were also found in measurements using H2O immersion and when varying the probe contact force. The effect of reasonable variation of the fiber-bending radius was found to be of negligible impact. The influence of measurements on hairy or sun-exposed body sites, as well as inter-subject variation, was also investigated. The presented results may serve as a guide to avoid negative effects during the process of data acquisition and so avoid misclassifcation in tumor discrimination.


Journal of Biomedical Optics | 2014

Evaluation of Raman spectroscopic macro raster scans of native cervical cone biopsies using histopathological mapping

Carina Reble; Ingo Gersonde; Cathrin Dressler; Jürgen Helfmann; Wolfgang Kühn; Hans Joachim Eichler

Abstract. Raman spectroscopy based discrimination of cervical precancer and normal tissue has been shown previously in vivo with fiber probe based measurements of colposcopically selected sites. With a view to developing in vivo large area imaging, macro raster scans of native cervical cone biopsies with an average of 200 spectra per sample are implemented (n=16). The diagnostic performance is evaluated using histopathological mapping of the cervix surface. Different data reduction and classification methods (principal component analysis, wavelets, k-nearest neighbors, logistic regression, partial least squares discriminant analysis) are compared. Using bootstrapping to estimate confidence intervals for sensitivity and specificity, it is concluded that differences among different spectra classification procedures are not significant. The classification performance is evaluated depending on the tissue pathologies included in the analysis using the average performance of different classification procedures. The highest sensitivity (91%) and specificity (81%) is obtained for the discrimination of normal squamous epithelium and high-grade precancer. When other non-high-grade tissue sites, such as columnar epithelium, metaplasia, and inflammation, are included, the diagnostic performance decreases.


Photonics and Lasers in Medicine | 2015

Raman spectroscopy for the discrimination of cancerous and normal skin

Johannes Schleusener; Carina Reble; Martina C. Meinke; Jürgen Helfmann

Abstract: Various studies have shown promising results in using Raman spectroscopy (RS) for the detection of skin cancers. In-vivo evaluations showed similar results to those found by trained dermatologists using dermoscopy, the current clinical practice for skin cancer diagnosis. However, dermoscopy is highly subjective which would make an objective, non-invasive diagnostic method useful. Although successful results were achieved, RS is barely applied in clinical routine yet. This review summarizes studies of Raman spectroscopy for skin cancer diagnosis ex vivo and in vivo. The latter has special demands that often lead to a tradeoff between applicability and classification performance. The necessary steps are explained for instrumentation design, handling, data analysis and clinical testing on groups with a sufficient amount of subjects in order to promote the application of RS in a routine clinical setting. A number of methods are summarized which attempt to overcome the ongoing challenge of reducing large background signals. Modifications of RS by combination with other diagnostic methods are summarized that can give a new perspective to future developments in RS.


Photonics and Lasers in Medicine | 2013

Spectral in vivo signature of carotenoids in visible light diffuse reflectance from skin in comparison to ex vivo absorption spectra

Stefan Andree; Carina Reble; Jürgen Helfmann

Abstract Objective: To increase the carotenoid concentration in skin by drinking carrot juice to generate an optical response and to determine an in vivo absorption spectrum of the carotenoids and compare it to ex vivo absorption spectra. Material and methods: The first author of the presented study consumed carrot juice over a period of several weeks and during this time regularly performed optical reflection measurements on his palm. The spectroscopic measurements were carried out with a fiber-based sensor using a thermal light source. Absorption coefficients have been deduced from the diffuse reflectance data. Measurements were also performed on a β-carotene solution, on carrot juice and its extracted carotenoids. The correlation coefficient between carrot juice intake in liters and the optical skin signal was used to select an optimal wavelength for carotenoid detection (493 nm). Results: An in vivo signal of the carotenoids was found in the spectral range from 400 nm to 580 nm. A 1-l intake of carrot juice resulted in a 0.6% decrease of the diffuse reflectance. The absorption of hemoglobin interferes with the carotenoid signal even though the blood was pressed away. Consequently, a method was used that could lead to the elimination of this disturbance and an in vivo absorption spectrum from the carotenoids in skin was determined by way of trial. The in vivo carotenoid spectrum and that of the carrot juice were both found to a similar extent to be spectrally broader than the absorption spectrum of β-carotene dissolved in cyclohexane. Conclusion: Detection of carotenoids in skin is possible by diffuse reflectance measurements with a simple spectroscopic optical setup, as it is described in this article. As found by comparing different publications, several geometries for illumination and detection support carotenoid quantification. However, the fiber probe described here is not limited to carotenoid detection and it does not need arrangement of several optical elements such as lenses, mirrors or apertures and therefore requiring less effort for development. To eliminate the interference of hemoglobin, the authors suggest the combination of pressure and the described software method. Other publications have reported hemoglobin interference with respect to in vivo carotenoid measurement. As the carotenoids are mainly found in the bloodless epidermis, setups are suggested which use smaller sampling volumes. Zusammenfassung Ziel: Erhöhen der Karotinoidkonzentration in der Haut, um messbare Veränderungen der optischen Eigenschaften der Haut zu erzeugen. Bestimmen eines In-vivo-Absorptionsspektrums der Karotinoide und Vergleich mit Ex-vivo-Absorptionsspektren. Material und Methoden: Über einen Zeitraum von mehreren Wochen nahm der Erstautor der Studie Karottensaft zu sich und führte währenddessen regelmäßige optische Reflektionsmessungen am Handballen durch. Die spektroskopischen Messungen wurden mit einem Faser-Sensor und einer thermischen Lichtquelle durchgeführt. Aus den Reflektionsspektren wurden Absorptionskoeffizienten ermittelt. Weitere Messungen wurden an einer Beta-Carotin-Lösung, an Karottensaft und an dessen extrahierten Karotinoiden durchgeführt. Es wurde eine optimale Wellenlänge für die Karotinoiddetektion (493 nm) bestimmt, bei der die Korrelation zwischen der diffusen Reflektion der Haut und der Menge an getrunkenem Karottensaft am höchsten war. Ergebnisse: Im Wellenlängenbereich von 400 bis 580 nm wurde ein In-vivo-Signal der Karotinoide gemessen. Pro Aufnahme von 1 l Karottensaft verringerte sich die diffuse Reflektion um 0.6%. Allerdings interferiert die Absorption von Hämoglobin mit der Karotinoidmessung, obwohl das Blut durch Anpressen des Messkopfes weggedrückt wurde. Folglich wurde eine Methode verwendet, die eine Korrektur dieses Störeinflusses ermöglichen könnte. Versuchsweise wurde hiermit ein In-vivo-Absorptionsspektrum der Karotinoide ermittelt. Es wurde festgestellt, dass das Signal der Karotinoide aus dem Karottensaft und der Haut in einem ähnlichen Ausmaß spektral breiter ist als das in Cyclohexan gelöste Beta-Carotin. Fazit: Karotinoide in der Haut können mit dem in diesem Artikel beschriebenen, einfachen spektroskopischen Messaufbau detektiert werden. Durch Vergleich mit anderen Versuchen zeigte sich, dass für die Beleuchtung und Detektion verschiedene Geometrien möglich sind. Der hier beschriebene Fasermesskopf ist jedoch nicht auf die Karotinoiddetektion beschränkt und es werden keine zusätzlichen Teile wie Linsen, Spiegel oder Blenden benötigt, womit der Entwicklungsaufwand verringert wird. Um den Störeinfluss durch Hämoglobin zu eliminieren, bietet sich eine Kombination aus Wegdrücken des Blutes und einer softwaretechnischen Korrekturrechnung an. Alternativ sollte die Beleuchtungs- und Detektionsgeometrie weiter verkleinert werden, damit hauptsächlich in der blutfreien Epidermis gemessen wird, denn dort ist die Karotinoidkonzentration am höchsten.


Clinical and Biomedical Spectroscopy (2009), paper 7368_0c | 2009

Correction of Raman signals for tissue optical properties

Carina Reble; Ingo Gersonde; Jürgen Helfmann; Stefan Andree; Gerd Illing

Raman signals of biological tissues are distorted by the influence of tissue absorption and scattering properties, which significantly challenges signal quantification. We investigated the influence of the tissue optical properties on the resonance Raman signal of β-carotene with tissue phantom measurements and Monte Carlo simulations. Both methods show that the Raman signal drops roughly proportional to 1/μa for absorption coefficients (μa) in the range of 0.1-4mm-1. The influence of the reduced scattering coefficient in the range of 0.1-8mm-1 is less strong, but not negligible. We introduce combined Raman and spatially resolved reflectance measurements to measure both Raman signals and tissue optical properties. The optical properties were deduced from the spatially resolved reflectance measurements by a Monte Carlo-based lookup table (LUT). For the signal correction we applied correction functions derived from the Monte Carlo simulations. We corrected in vivo resonance Raman measurements of carotenoids in caucasian skin (n=9) with respect to the mean optical properties of the group. The magnitude of the average correction effect was found to be 18±11% on the minimal pigmented palm.


Photonics and Lasers in Medicine | 2015

Development of an in-vivo sensor for monitoring of water content in skin

Rijk Schütz; Ihar Shchatsinin; Uwe Bindig; Carina Reble; Jürgen Helfmann

Abstract A change in the water distribution of the human body, such as water retention in the skin, can be a symptom of a pathological condition including heart failure. Therefore, a sensor for the non-invasive quantification of the water content of the skin could be useful where continuous monitoring of patients is required to detect and avoid life threatening conditions. As water is a major absorber of tissue in the near-infrared wavelength range, the water content can be determined based on reflectance measurements. Measuring the diffuse reflectance at multiple distances from the point of illumination allows the determination of absorption in scattering media such as skin. The aim of this project was to develop a small and portable sensor based on light emitting diodes and photodiodes. Evaluation of the first functional sensor design has showed that the water content of tissue phantoms can be predicted with a prediction error of 1%. Further developments towards a sensor that can be applied in a future field study are ongoing.


Biomedical spectroscopy and imaging | 2011

Evaluation of a novel fiber probe for spatially and spectrally resolved reflectance measurements of turbid media

Stefan Andree; Heiko Luckmann; Carina Reble; Ingo Gersonde; Jürgen Helfmann

A novel fiber probe for spatially resolved reflectance measurements is presented, which uses simultaneously read-out spectrometers for each source-detector separation. Therefore, with this fiber probe and a Monte Carlo simulation, it is possible to determine spectrally resolved absorption and reduced scattering coefficients from various skinsites. The absolute calibration is done by using an integrating sphere but a phantom based calibration procedure was undertaken to compare the results of different calibration techniques. For tissue measurements, a standard SMA adaptor with a one inch diameter face can be used to provide a stable base for placing the probe onto the tissue and the possibility to apply pressure. The evaluation process was carried out by comparing the measured absorption and scattering of silicone and liquid phantoms to their reference values, obtained by integrating sphere spectroscopy. In addition, preliminary skin measurements are presented.


Journal of Biomedical Optics | 2010

Quantitative Raman spectroscopy in turbid media

Carina Reble; Ingo Gersonde; Stefan Andree; Hans Joachim Eichler; Jürgen Helfmann

Collaboration


Dive into the Carina Reble's collaboration.

Top Co-Authors

Avatar

Stefan Andree

Technical University of Berlin

View shared research outputs
Top Co-Authors

Avatar

Hans Joachim Eichler

Technical University of Berlin

View shared research outputs
Researchain Logo
Decentralizing Knowledge