Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Cecilia Eriksson Linsmeier is active.

Publication


Featured researches published by Cecilia Eriksson Linsmeier.


PLOS ONE | 2011

Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS

Jonas Thelin; Henrik Jörntell; Elia Psouni; Martin Garwicz; Jens Schouenborg; Nils Danielsen; Cecilia Eriksson Linsmeier

The function of chronic brain machine interfaces depends on stable electrical contact between neurons and electrodes. A key step in the development of interfaces is therefore to identify implant configurations that minimize adverse long-term tissue reactions. To this end, we here characterized the separate and combined effects of implant size and fixation mode at 6 and 12 weeks post implantation in rat (n = 24) cerebral cortex. Neurons and activated microglia and astrocytes were visualized using NeuN, ED1 and GFAP immunofluorescence microscopy, respectively. The contributions of individual experimental variables to the tissue response were quantified. Implants tethered to the skull caused larger tissue reactions than un-tethered implants. Small diameter (50 µm) implants elicited smaller tissue reactions and resulted in the survival of larger numbers of neurons than did large diameter (200 µm) implants. In addition, tethering resulted in an oval-shaped cavity, with a cross-section area larger than that of the implant itself, and in marked changes in morphology and organization of neurons in the region closest to the tissue interface. Most importantly, for implants that were both large diameter and tethered, glia activation was still ongoing 12 weeks after implantation, as indicated by an increase in GFAP staining between week 6 and 12, while this pattern was not observed for un-tethered, small diameter implants. Our findings therefore clearly indicate that the combined small diameter, un-tethered implants cause the smallest tissue reactions.


Journal of Neural Engineering | 2010

Gelatine-embedded electrodes?a novel biocompatible vehicle allowing implantation of highly flexible microelectrodes

Gustav Lind; Cecilia Eriksson Linsmeier; Jonas Thelin; Jens Schouenborg

Chronic neural interfaces that are both structurally and functionally stable inside the brain over years or decades hold great promise to become an invaluable clinical tool in the near future. A key flaw in the current electrode interfaces is that their recording capabilities deteriorate over time, possibly due to the lack of flexibility, which causes movements in relation to the neural tissue that result in small inflammations and loss of electrode function. We have developed a new neural probe using the stabilizing property of gelatine that allows the implantation of ultra-thin and flexible electrodes into the central nervous system. The microglial and astrocytic reactions evoked by implanted gelatine needles, as well as the wire bundles in combination with gelatine, were investigated using immunohistochemistry and fluorescence microscopy up to 12 weeks after implantation. The results indicate that pure gelatine needles were stiff enough to penetrate the brain tissue on their own, and evoked a significantly smaller chronic scar than stab wounds. Moreover, gelatine embedding appeared to reduce the acute reactions caused by the implants and we found no adverse effects of gelatine or gelatine-embedded electrodes. Successful electrophysiological recordings were made from very thin electrodes implanted in this fashion.


Scientific Reports | 2013

The density difference between tissue and neural probes is a key factor for glial scarring.

Gustav Lind; Cecilia Eriksson Linsmeier; Jens Schouenborg

A key to successful chronic neural interfacing is to achieve minimal glial scarring surrounding the implants, as the astrocytes and microglia may functionally insulate the interface. A possible explanation for the development of these reactions is mechanical forces arising between the implants and the brain. Here, we show that the difference between the density of neural probes and that of the tissue, and the resulting inertial forces, are key factors for the development of the glial scar. Two probes of similar size, shape, surface structure and elastic modulus but differing greatly in density were implanted into the rat brain. After six weeks, significantly lower astrocytic and microglial reactions were found surrounding the low-density probes, approaching no reaction at all. This provides a major key to design fully biocompatible neural interfaces and a new platform for in vivo assays of tissue reactions to probes with differing materials, surface structures, and shapes.


Nano Letters | 2009

Nanowire Biocompatibility in the Brain - Looking for a Needle in a 3D Stack.

Cecilia Eriksson Linsmeier; Christelle N. Prinz; Lina M.E. Pettersson; Philippe Caroff; Lars Samuelson; Jens Schouenborg; Lars Montelius; Nils Danielsen

We investigated the brain-tissue response to nanowire implantations in the rat striatum after 1, 6, and 12 weeks using immunohistochemistry. The nanowires could be visualized in the scar by confocal microscopy (through the scattered laser light). For the nanowire-implanted animals, there is a significant astrocyte response at week 1 compared to controls. The nanowires are phagocytized by ED1 positive microglia, and some of them are degraded and/or transported away from the brain.


IEEE Transactions on Biomedical Engineering | 2008

The Influence of Porous Silicon on Axonal Outgrowth in Vitro

Fredrik Johansson; Martin Kanje; Cecilia Eriksson Linsmeier; Lars Wallman

Axonal outgrowth on smooth and porous silicon surfaces was studied in organ culture. The pore size of the silicon substrata varied between 100 and 1500 nm. We found that axons preferred to grow and elongate on porous silicon surfaces only when pores of (150-500 nm) are available.


Biomaterials | 2008

Soft tissue reactions evoked by implanted gallium phosphide.

Cecilia Eriksson Linsmeier; Lars Wallman; Linda Faxius; Jens Schouenborg; Lars Magnus Bjursten; Nils Danielsen

Neural devices may play an important role in the diagnosis and therapy of several clinical conditions, such as stroke, trauma or neurodegenerative disorders, by facilitating motor and pain control. Such interfaces, chronically implanted in the CNS, need to be biocompatible and have the ability to stimulate and record nerve signals. However, neural devices of today are not fully optimized. Nanostructured surfaces may improve electrical properties and lower evoked tissue responses. Vertical gallium phosphide (GaP) nanowires epitaxially grown from a GaP surface is one way of creating nanostructured electrodes. Thus, we chose to study the soft tissue reactions evoked by GaP surfaces. GaP and the control material titanium (Ti) were implanted in the rat abdominal wall for evaluation of tissue reactions after 1, 6, or 12 weeks. The foreign-body response was evaluated by measuring the reactive capsule thickness and by quantification of ED1-positive macrophages and total cells in the capsule. Furthermore, the concentration of Ga was measured in blood, brain, liver and kidneys. Statistically significant differences were noticed between GaP and Ti at 12 weeks for total and ED1-positive cell densities in the capsule. The chemical analysis showed that the concentration of Ga in brain, liver and kidneys increased during 12 weeks of implantation, indicating loss of Ga from the implant. Taken together, our results show that the biocompatible properties of GaP are worse than those of the well-documented biomaterial Ti.


Biomaterials | 2015

Size-dependent long-term tissue response to biostable nanowires in the brain

Lina Gällentoft; Lina M.E. Pettersson; Nils Danielsen; Jens Schouenborg; Christelle N. Prinz; Cecilia Eriksson Linsmeier

Nanostructured neural interfaces, comprising nanotubes or nanowires, have the potential to overcome the present hurdles of achieving stable communication with neuronal networks for long periods of time. This would have a strong impact on brain research. However, little information is available on the brain response to implanted high-aspect-ratio nanoparticles, which share morphological similarities with asbestos fibres. Here, we investigated the glial response and neuronal loss in the rat brain after implantation of biostable and structurally controlled nanowires of different lengths for a period up to one year post-surgery. Our results show that, as for lung and abdominal tissue, the brain is subject to a sustained, local inflammation when biostable and high-aspect-ratio nanoparticles of 5 μm or longer are present in the brain tissue. In addition, a significant loss of neurons was observed adjacent to the 10 μm nanowires after one year. Notably, the inflammatory response was restricted to a narrow zone around the nanowires and did not escalate between 12 weeks and one year. Furthermore, 2 μm nanowires did not cause significant inflammatory response nor significant loss of neurons nearby. The present results provide key information for the design of future neural implants based on nanomaterials.


PLOS ONE | 2015

Influence of Probe Flexibility and Gelatin Embedding on Neuronal Density and Glial Responses to Brain Implants

Per Köhler; Anette Wolff; Fredrik Ejserholm; Lars Wallman; Jens Schouenborg; Cecilia Eriksson Linsmeier

To develop long-term high quality communication between brain and computer, a key issue is how to reduce the adverse foreign body responses. Here, the impact of probe flexibility and gelatine embedding on long-term (6w) tissue responses, was analyzed. Probes of same polymer material, size and shape, flexible mainly in one direction, were implanted in rat cerebral cortex (nimplants = 3 x 8) in two orientations with respect to the major movement direction of the brain relative to the skull: parallel to (flex mode) or transverse to (rigid mode). Flex mode implants were either embedded in gelatin or non-embedded. Neurons, activated microglia and astrocytes were visualized using immunohistochemistry. The astrocytic reactivity, but not microglial response, was significantly lower to probes implanted in flex mode as compared to rigid mode. The microglial response, but not astrocytic reactivity, was significantly smaller to gelatin embedded probes (flex mode) than non-embedded. Interestingly, the neuronal density was preserved in the inner zone surrounding gelatin embedded probes. This contrasts to the common reports of reduced neuronal density close to implanted probes. In conclusion, sheer stress appears to be an important factor for astrocytic reactivity to implanted probes. Moreover, gelatin embedding can improve the neuronal density and reduce the microglial response close to the probe.


Neuroreport | 2007

Galectin-3 inhibits Schwann cell proliferation in cultured sciatic nerve

Per M. Gustavsson; Cecilia Eriksson Linsmeier; Hakon Leffler; Martin Kanje

The production of galectin-3, a carbohydrate-binding mammalian lectin, is upregulated in Schwann cells after peripheral nerve injury in areas where Schwann cells proliferate. Here we tested if galectin-3 affected proliferation of Schwann cells in cultured sciatic nerve segments. Galectin-3 significantly decreased the number of bromodeoxyuridine-labelled Schwann cell nuclei. Neither lactose nor a synthetic inhibitor directed against the carbohydrate-binding region abolished the effects of galectin-3. In addition, a mutant galectin-3 unable to bind endogenous carbohydrates had similar effects as normal galectin-3. We conclude that galectin-3 reduces proliferation of Schwann cells in cultured sciatic nerve segments by a mechanism which is independent of its carbohydrate-binding moiety.


Progress in Brain Research | 2011

Can histology solve the riddle of non-functioning electrodes; factors influencing the biocompatibillity of brain machine interfaces.

Cecilia Eriksson Linsmeier; Jonas Thelin; Nils Danielsen

Neural interfaces hold great promise to become invaluable clinical and diagnostic tools in the near future. However, the biocompatibility and the long-term stability of the implanted interfaces are far from optimized. There are several factors that need to be addressed and standardized when improving the long-term success of an implanted electrode. We have chosen to focus on three key factors when evaluating the evoked tissue responses after electrode implantation into the brain: implant size, fixation mode, and evaluation period. Further, we show results from an ultrathin multichannel wire electrode that has been implanted in the rat cerebral cortex for 1 year. To improve biocompatibility of implanted electrodes, we would like to suggest that free-floating, very small, flexible, and, in time, wireless electrodes would elicit a diminished cell encapsulation. We would also like to suggest standardized methods for the electrode design, the electrode implantation method, and the analyses of cell reactions after implantation into the CNS in order to improve the long-term success of implanted neural interfaces.

Collaboration


Dive into the Cecilia Eriksson Linsmeier's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge