European Journal of Orthopaedic Surgery and Traumatology | 2004

Osseointegration study of porous nitinol versus titanium orthopaedic implants

Fidèle Likibi; Michel Assad; Peter Jarzem; Michel A. Leroux; Christine Coillard; Gilles Chabot; Charles-H. Rivard

The functionality of a new metallic interbody fusion implant manufactured out of porous nitinol (PNT) was evaluated in sheep and compared to a conventional titanium (TiAIV) intervertebral cage packed with autologous iliac crest bone. Both device types were implanted at two non-contiguous intervertebral lumbar sites. The objective was to evaluate the osseointegration capacity after 3, 6 and 12 months of implantation in the presence of these two implant types subjected to the same mechanical loads. Two-dimensional radiology, computer tomography and histology were used as techniques of parameter evaluation. The results indicated that PNT obtained a better intervertebral osseointegration capacity compared to the TiAlV cage. The functional difficulties of the titanium implant were related to its instability at the implantation site possibly due to a biofunctionality problem. The biocompatibility of both implants seemed comparable, however.RésuméLa fonctionnalité d’un nouvel implant métallique de fusion intervertébrale en nitinol poreux (PNT) a été évaluée chez la brebis, puis comparée à celle de la cage de fusion intervertébrale conventionnelle en titane (TiAlV). Le titane, contrairement au PNT, nécessitait une greffe osseuse à partir de la crête iliaque lors de l’implantation. L’objectif de ces recherches était d’évaluer, après 3, 6 et 12 mois postopératoires, la capacité ostéointégrative de ces deux types d’implants soumis aux mêmes sollicitations mécaniques du rachis à deux niveaux lombaires non-contigus. La radiologie bidimensionnelle, la tomographie et l’histologie furent utilisées comme techniques d’évaluation des paramètres d’intégration osseuse. Les résultats ont indiqué que le PNT, comparé au TiAlV, avait une meilleure capacité ostéointégrative. Les difficultés fonctionnelles du TiAlV étaient liées à son instabilité dans le site d’implantation, possiblement à cause d’un problème de biofonctionnalité. La biocompatibilité des deux implants semblait toutefois comparable.


Journal of Biomedical Materials Research | 2002

In vivo biocompatibility testing of peek polymer for a spinal implant system: A study in rabbits

Charles-H. Rivard; Souad Rhalmi; Christine Coillard


Journal of Biomedical Materials Research Part B | 2003

Porous titanium-nickel for intervertebral fusion in a sheep model: part 1. Histomorphometric and radiological analysis.

Michel Assad; Peter Jarzem; Michel A. Leroux; Christine Coillard; Alexandr Chernyshov; Sylvie Charette; Charles-H. Rivard


European Spine Journal | 2009

Postural imbalance in non-treated adolescent idiopathic scoliosis at different periods of progression.

Marlène Beaulieu; Claire Toulotte; Laura Gatto; Charles-H. Rivard; Normand Teasdale; Martin Simoneau; Paul Allard


Clinical Biomechanics | 2005

Evaluation of segmental postural characteristics during quiet standing in control and Idiopathic Scoliosis patients.

Karl Zabjek; Michel A. Leroux; Christine Coillard; Charles-H. Rivard; François Prince


Journal of Biomedical Materials Research Part B | 2003

Porous titanium-nickel for intervertebral fusion in a sheep model: Part 2. Surface analysis and nickel release assessment

Michel Assad; Alexandr Chernyshov; P. Jarzem; Michel A. Leroux; Christine Coillard; Sylvie Charette; Charles-H. Rivard


Journal of Spinal Disorders | 2000

Pre-, intra-, and postoperative three-dimensional evaluation of adolescent idiopathic scoliosis

S. Delorme; Hubert Labelle; Benoîfmt Poitras; Charles-H. Rivard; Christine Coillard; J. Dansereau


Bio-medical Materials and Engineering | 2002

A new porous titanium–nickel alloy: Part 1. Cytotoxicity and genotoxicity evaluation

Michel Assad; Alexandr Chernyshov; Michel A. Leroux; Charles-H. Rivard


European Spine Journal | 2008

Estimation of the centre of mass for the study of postural control in Idiopathic Scoliosis patients: a comparison of two techniques

Karl Zabjek; Christine Coillard; Charles-H. Rivard; François Prince


Annales De Chirurgie | 1998

Stereovideographic evaluation of the postural geometry of healthy and scoliotic patients

De la Huerta F; Michel A. Leroux; Karl Zabjek; Christine Coillard; Charles-H. Rivard

Collaboration


Dive into the Charles-H. Rivard's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Fidèle Likibi

Université de Montréal

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Hubert Labelle

Université de Montréal

View shared research outputs
Top Co-Authors

Avatar

J. Dansereau

École Polytechnique de Montréal

View shared research outputs
Top Co-Authors

Avatar

Laura Gatto

Université de Montréal

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge