Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Choonsik Lee is active.

Publication


Featured researches published by Choonsik Lee.


The Lancet | 2012

Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study

Mark S. Pearce; J Salotti; Mark P. Little; Kieran McHugh; Choonsik Lee; Kwang Pyo Kim; Nicola L Howe; Cécile M. Ronckers; Preetha Rajaraman; Alan W. Craft; Louise Parker; Amy Berrington de Gonzalez

Summary Background Although CT scans are very useful clinically, potential cancer risks exist from associated ionising radiation, in particular for children who are more radiosensitive than adults. We aimed to assess the excess risk of leukaemia and brain tumours after CT scans in a cohort of children and young adults. Methods In our retrospective cohort study, we included patients without previous cancer diagnoses who were first examined with CT in National Health Service (NHS) centres in England, Wales, or Scotland (Great Britain) between 1985 and 2002, when they were younger than 22 years of age. We obtained data for cancer incidence, mortality, and loss to follow-up from the NHS Central Registry from Jan 1, 1985, to Dec 31, 2008. We estimated absorbed brain and red bone marrow doses per CT scan in mGy and assessed excess incidence of leukaemia and brain tumours cancer with Poisson relative risk models. To avoid inclusion of CT scans related to cancer diagnosis, follow-up for leukaemia began 2 years after the first CT and for brain tumours 5 years after the first CT. Findings During follow-up, 74 of 178 604 patients were diagnosed with leukaemia and 135 of 176 587 patients were diagnosed with brain tumours. We noted a positive association between radiation dose from CT scans and leukaemia (excess relative risk [ERR] per mGy 0·036, 95% CI 0·005–0·120; p=0·0097) and brain tumours (0·023, 0·010–0·049; p<0·0001). Compared with patients who received a dose of less than 5 mGy, the relative risk of leukaemia for patients who received a cumulative dose of at least 30 mGy (mean dose 51·13 mGy) was 3·18 (95% CI 1·46–6·94) and the relative risk of brain cancer for patients who received a cumulative dose of 50–74 mGy (mean dose 60·42 mGy) was 2·82 (1·33–6·03). Interpretation Use of CT scans in children to deliver cumulative doses of about 50 mGy might almost triple the risk of leukaemia and doses of about 60 mGy might triple the risk of brain cancer. Because these cancers are relatively rare, the cumulative absolute risks are small: in the 10 years after the first scan for patients younger than 10 years, one excess case of leukaemia and one excess case of brain tumour per 10 000 head CT scans is estimated to occur. Nevertheless, although clinical benefits should outweigh the small absolute risks, radiation doses from CT scans ought to be kept as low as possible and alternative procedures, which do not involve ionising radiation, should be considered if appropriate. Funding US National Cancer Institute and UK Department of Health.


JAMA | 2012

Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996-2010

Rebecca Smith-Bindman; Diana L. Miglioretti; Eric Johnson; Choonsik Lee; Heather Spencer Feigelson; Michael J. Flynn; Robert T. Greenlee; Randell Kruger; Mark C. Hornbrook; Douglas W. Roblin; Leif I. Solberg; Nicholas Vanneman; Sheila Weinmann; Andrew E. Williams

CONTEXT Use of diagnostic imaging has increased significantly within fee-for-service models of care. Little is known about patterns of imaging among members of integrated health care systems. OBJECTIVE To estimate trends in imaging utilization and associated radiation exposure among members of integrated health care systems. DESIGN, SETTING, AND PARTICIPANTS Retrospective analysis of electronic records of members of 6 large integrated health systems from different regions of the United States. Review of medical records allowed direct estimation of radiation exposure from selected tests. Between 1 million and 2 million member-patients were included each year from 1996 to 2010. MAIN OUTCOME MEASURE Advanced diagnostic imaging rates and cumulative annual radiation exposure from medical imaging. RESULTS During the 15-year study period, enrollees underwent a total of 30.9 million imaging examinations (25.8 million person-years), reflecting 1.18 tests (95% CI, 1.17-1.19) per person per year, of which 35% were for advanced diagnostic imaging (computed tomography [CT], magnetic resonance imaging [MRI], nuclear medicine, and ultrasound). Use of advanced diagnostic imaging increased from 1996 to 2010; CT examinations increased from 52 per 1000 enrollees in 1996 to 149 per 1000 in 2010, 7.8% annual increase (95% CI, 5.8%-9.8%); MRI use increased from 17 to 65 per 1000 enrollees, 10% annual growth (95% CI, 3.3%-16.5%); and ultrasound rates increased from 134 to 230 per 1000 enrollees, 3.9% annual growth (95% CI, 3.0%-4.9%). Although nuclear medicine use decreased from 32 to 21 per 1000 enrollees, 3% annual decline (95% CI, 7.7% decline to 1.3% increase), PET imaging rates increased after 2004 from 0.24 to 3.6 per 1000 enrollees, 57% annual growth. Although imaging use increased within all health systems, the adoption of different modalities for anatomic area assessment varied. Increased use of CT between 1996 and 2010 resulted in increased radiation exposure for enrollees, with a doubling in the mean per capita effective dose (1.2 mSv vs 2.3 mSv) and the proportion of enrollees who received high (>20-50 mSv) exposure (1.2% vs 2.5%) and very high (>50 mSv) annual radiation exposure (0.6% vs 1.4%). By 2010, 6.8% of enrollees who underwent imaging received high annual radiation exposure (>20-50 mSv) and 3.9% received very high annual exposure (>50 mSv). CONCLUSION Within integrated health care systems, there was a large increase in the rate of advanced diagnostic imaging and associated radiation exposure between 1996 and 2010.


Physics in Medicine and Biology | 2010

The UF family of reference hybrid phantoms for computational radiation dosimetry

Choonsik Lee; Daniel Lodwick; Jorge L. Hurtado; Deanna Pafundi; Jonathan L. Williams; Wesley E. Bolch

Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms-those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR. NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros. The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference organ masses from ICRP Publication 89, (3) reference elemental compositions provided in ICRP 89 as well as ICRU Report 46, and (4) reference data on the alimentary tract organs given in ICRP Publications 89 and 100. Various adjustments and refinements to the organ systems of the previously described newborn, 15 year and adult phantoms are also presented. The UF series of hybrid phantoms retain the non-uniform scalability of stylized phantoms while maintaining the anatomical realism of patient-specific voxel phantoms with respect to organ shape, depth and inter-organ distance. While the final versions of these phantoms are in a voxelized format for radiation transport simulation, their primary format is given as NURBS and polygon mesh surfaces, thus permitting one to sculpt non-reference phantoms using the reference phantoms as an anatomic template.


Physics in Medicine and Biology | 2007

Hybrid computational phantoms of the male and female newborn patient : NURBS-based whole-body models

Choonsik Lee; Daniel Lodwick; Deanna Hasenauer; Jonathan L. Williams; Choonik Lee; Wesley E. Bolch

Anthropomorphic computational phantoms are computer models of the human body for use in the evaluation of dose distributions resulting from either internal or external radiation sources. Currently, two classes of computational phantoms have been developed and widely utilized for organ dose assessment: (1) stylized phantoms and (2) voxel phantoms which describe the human anatomy via mathematical surface equations or 3D voxel matrices, respectively. Although stylized phantoms based on mathematical equations can be very flexible in regard to making changes in organ position and geometrical shape, they are limited in their ability to fully capture the anatomic complexities of human internal anatomy. In turn, voxel phantoms have been developed through image-based segmentation and correspondingly provide much better anatomical realism in comparison to simpler stylized phantoms. However, they themselves are limited in defining organs presented in low contrast within either magnetic resonance or computed tomography images-the two major sources in voxel phantom construction. By definition, voxel phantoms are typically constructed via segmentation of transaxial images, and thus while fine anatomic features are seen in this viewing plane, slice-to-slice discontinuities become apparent in viewing the anatomy of voxel phantoms in the sagittal or coronal planes. This study introduces the concept of a hybrid computational newborn phantom that takes full advantage of the best features of both its stylized and voxel counterparts: flexibility in phantom alterations and anatomic realism. Non-uniform rational B-spline (NURBS) surfaces, a mathematical modeling tool traditionally applied to graphical animation studies, was adopted to replace the limited mathematical surface equations of stylized phantoms. A previously developed whole-body voxel phantom of the newborn female was utilized as a realistic anatomical framework for hybrid phantom construction. The construction of a hybrid phantom is performed in three steps: polygonization of the voxel phantom, organ modeling via NURBS surfaces and phantom voxelization. Two 3D graphic tools, 3D-DOCTOR and Rhinoceros, were utilized to polygonize the newborn voxel phantom and generate NURBS surfaces, while an in-house MATLAB code was used to voxelize the resulting NURBS model into a final computational phantom ready for use in Monte Carlo radiation transport calculations. A total of 126 anatomical organ and tissue models, including 38 skeletal sites and 31 cartilage sites, were described within the hybrid phantom using either NURBS or polygon surfaces. A male hybrid newborn phantom was constructed following the development of the female phantom through the replacement of female-specific organs with male-specific organs. The outer body contour and internal anatomy of the NURBS-based phantoms were adjusted to match anthropometric and reference newborn data reported by the International Commission on Radiological Protection in their Publication 89. The voxelization process was designed to accurately convert NURBS models to a voxel phantom with minimum volumetric change. A sensitivity study was additionally performed to better understand how the meshing tolerance and voxel resolution would affect volumetric changes between the hybrid-NURBS and hybrid-voxel phantoms. The male and female hybrid-NURBS phantoms were constructed in a manner so that all internal organs approached their ICRP reference masses to within 1%, with the exception of the skin (-6.5% relative error) and brain (-15.4% relative error). Both hybrid-voxel phantoms were constructed with an isotropic voxel resolution of 0.663 mm--equivalent to the ICRP 89 reference thickness of the newborn skin (dermis and epidermis). Hybrid-NURBS phantoms used to create their voxel counterpart retain the non-uniform scalability of stylized phantoms, while maintaining the anatomic realism of segmented voxel phantoms with respect to organ shape, depth and inter-organ positioning.


CA: A Cancer Journal for Clinicians | 2012

Cancer Risks Associated With External Radiation From Diagnostic Imaging Procedures

Martha S. Linet; Thomas L. Slovis; Donald L. Miller; Ruth A. Kleinerman; Choonsik Lee; Preetha Rajaraman; Amy Berrington de Gonzalez

The 600% increase in medical radiation exposure to the US population since 1980 has provided immense benefit, but increased potential future cancer risks to patients. Most of the increase is from diagnostic radiologic procedures. The objectives of this review are to summarize epidemiologic data on cancer risks associated with diagnostic procedures, describe how exposures from recent diagnostic procedures relate to radiation levels linked with cancer occurrence, and propose a framework of strategies to reduce radiation from diagnostic imaging in patients. We briefly review radiation dose definitions, mechanisms of radiation carcinogenesis, key epidemiologic studies of medical and other radiation sources and cancer risks, and dose trends from diagnostic procedures. We describe cancer risks from experimental studies, future projected risks from current imaging procedures, and the potential for higher risks in genetically susceptible populations. To reduce future projected cancers from diagnostic procedures, we advocate the widespread use of evidence‐based appropriateness criteria for decisions about imaging procedures; oversight of equipment to deliver reliably the minimum radiation required to attain clinical objectives; development of electronic lifetime records of imaging procedures for patients and their physicians; and commitment by medical training programs, professional societies, and radiation protection organizations to educate all stakeholders in reducing radiation from diagnostic procedures. CA Cancer J Clin 2012.


Clinical Oncology | 2011

Medical Exposure to Radiation and Thyroid Cancer

Sara J. Schonfeld; Choonsik Lee; A. Berrington de González

In 2008, the worldwide estimated age-standardised incidence rates for thyroid cancer incidence were 4.7 and 1.5 per 100,000 women and men, respectively. Thyroid cancers overall contribution to the worldwide cancer burden is relatively small, but incidence rates have increased over the last three decades throughout the world. This trend has been hypothesised to reflect a combination of technological advances enabling increased detection, but also changes in environmental factors, including population exposure to ionising radiation from fallout, diagnostic tests and treatment for benign and malignant conditions. Studies of the atomic bomb survivors and populations treated with radiotherapy have established radiation as a risk factor for thyroid cancer, particularly from early life exposure. About 0.62 mSv (20%) of the global annual per caput effective radiation dose comes from diagnostic medical and dental radiation for the period of 1997-2007, increased from 0.4 mSv for the years 1991-1996. This international trend of increasing population exposure to medical diagnostic sources of radiation, attributed in large part to the growing use of computed tomography scans, but also interventional radiology procedures, has raised concerns about exposure to radiosensitive organs such as the thyroid. Worldwide, medical and dental X-rays constitute the most common type of diagnostic medical exposures, but their contribution to the cumulative effective dose is relatively low, whereas computed tomography scans account for 7.9% of diagnostic radiology examinations but 47% of the collective effective dose from diagnostic radiation procedures in parts of the world. Although the radiation exposure from computed tomography scans is substantially lower than that from radiotherapy, multiple computed tomography scans could result in non-trivial cumulative doses to the thyroid. Studies are currently underway to assess the incidence of cancer in large cohorts of children who received computed tomography scans. National and international efforts have been developed to raise awareness and to standardise procedures for use of computed tomography and interventional radiology procedures in paediatric and general populations.


Medical Physics | 2008

Hybrid computational phantoms of the 15-year male and female adolescent: Applications to CT organ dosimetry for patients of variable morphometry

Choonsik Lee; Daniel Lodwick; Jonathan L. Williams; Wesley E. Bolch

Currently, two classes of the computational phantoms have been developed for dosimetry calculation: (1) stylized (or mathematical) and (2) voxel (or tomographic) phantoms describing human anatomy through mathematical surface equations and three-dimensional labeled voxel matrices, respectively. Mathematical surface equations in stylized phantoms provide flexibility in phantom design and alteration, but the resulting anatomical description is, in many cases, not very realistic. Voxel phantoms display far better anatomical realism, but they are limited in terms of their ability to alter organ shape, position, and depth, as well as body posture. A new class of computational phantoms--called hybrid phantoms-takes advantage of the best features of stylized and voxel phantoms-flexibility and anatomical realism, respectively. In the current study, hybrid computational phantoms representing reference 15-year male and female body anatomy and anthropometry are presented. For the male phantom, organ contours were extracted from the University of Florida (UF) 14-year series B male voxel phantom, while for the female phantom, original computed tomography (CT) data from two 14-year female patients were used. Polygon mesh models for the major organs and tissues were reconstructed for nonuniform rational B-spline (NURBS) surface modeling. The resulting NURBS/polygon mesh models representing body contour and internal anatomy were matched to anthropometric data and reference organ mass data provided by the Centers for Disease Control and Prevention (CDC) and the International Commission on Radiation Protection (ICRP), respectively. Finally, two hybrid 15-year male and female phantoms were completed where a total of eight anthropometric data categories were matched to standard values within 4% and organ masses matched to ICRP data within 1% with the exception of total skin. To highlight the flexibility of the hybrid phantoms, 10th and 90th weight percentile 15-year male and female phantoms were further developed from the 50th percentile phantoms through adjustments in the body contour to match the total body masses given in CDC pediatric growth curves. The resulting six NURBS phantoms, male and female phantoms representing their 10th, 50th, and 90th weight percentiles, were used to investigate the influence of body fat distributions on internal organ doses following CT imaging. The phantoms were exposed to multislice chest and abdomen helical CT scans, and in-field organ absorbed doses were calculated. The results demonstrated that the use of traditional stylized phantoms yielded organ dose estimates that deviate from those given by the UF reference hybrid phantoms by up to a factor of 2. The study also showed that use of reference, or 50th percentile, phantoms to assess organ doses in underweight 15-year-old children would not lead to significant organ dose errors (typically less than 10%). However, more significant errors were noted (up to approximately 30%) when reference phantoms are used to represent overweight children in CT imaging dosimetry. These errors are expected to only further increase as one considers CT organ doses in overweight and obese individuals of the adult patient population, thus emphasizing the advantages of patient-sculptable phantom technology.


Medical Physics | 2006

Development of the two Korean adult tomographic computational phantoms for organ dosimetry

Choonsik Lee; Choonik Lee; Sang-Hyun Park; Jai Ki Lee

Following the previously developed Korean tomographic phantom, KORMAN, two additional whole-body tomographic phantoms of Korean adult males were developed from magnetic resonance (MR) and computed tomography (CT) images, respectively. Two healthy male volunteers, whose body dimensions were fairly representative of the average Korean adult male, were recruited and scanned for phantom development. Contiguous whole body MR images were obtained from one subject exclusive of the arms, while whole-body CT images were acquired from the second individual. A total of 29 organs and tissues and 19 skeletal sites were segmented via image manipulation techniques such as gray-level thresholding, region growing, and manual drawing, in which each of segmented image slice was subsequently reviewed by an experienced radiologist for anatomical accuracy. The resulting phantoms, the MR-based KTMAN-1 (Korean Typical MAN-1) and the CT-based KTMAN-2 (Korean Typical MAN-2), consist of 300 X 150 X 344 voxels with a voxel resolution of 2 X 2 X 5 mm3 for both phantoms. Masses of segmented organs and tissues were calculated as the product of a nominal reference density, the prevoxel volume, and the cumulative number of voxels defining each organs or tissue. These organs masses were then compared with those of both the Asian and the ICRP reference adult male. Organ masses within both KTMAN-1 and KTMAN-2 showed differences within 40% of Asian and ICRP reference values, with the exception of the skin, gall bladder, and pancreas which displayed larger differences. The resulting three-dimensional binary file was ported to the Monte Carlo code MCNPX2.4 to calculate organ doses following external irradiation for illustrative purposes. Colon, lung, liver, and stomach absorbed doses, as well as the effective dose, for idealized photon irradiation geometries (anterior-posterior and right lateral) were determined, and then compared with data from two other tomographic phantoms (Asian and Caucasian), and stylized ORNL phantom. The armless KTMAN-1 can be applied to dosimetry for computed tomography or lateral x-ray examination, while the whole body KTMAN-2 can be used for radiation protection dosimetry.


Medical Physics | 2005

The UF series of tomographic computational phantoms of pediatric patients

Choonik Lee; Jonathan L. Williams; Choonsik Lee; Wesley E. Bolch

Two classes of anthropomorphic computational phantoms exist for use in Monte Carlo radiation transport simulations: tomographic voxel phantoms based upon three-dimensional (3D) medical images, and stylized mathematical phantoms based upon 3D surface equations for internal organ definition. Tomographic phantoms have shown distinct advantages over the stylized phantoms regarding their similarity to real human anatomy. However, while a number of adult tomographic phantoms have been developed since the early 1990s, very few pediatric tomographic phantoms are presently available to support dosimetry in pediatric diagnostic and therapy examinations. As part of a larger effort to construct a series of tomographic phantoms of pediatric patients, five phantoms of different ages (9-month male, 4-year female, 8-year female, 11-year male, and 14-year male) have been constructed from computed tomography (CT) image data of live patients using an IDL-based image segmentation tool. Lungs, bones, and adipose tissue were automatically segmented through use of window leveling of the original CT numbers. Additional organs were segmented either semiautomatically or manually with the aid of both anatomical knowledge and available image-processing techniques. Layers of skin were created by adding voxels along the exterior contour of the bodies. The phantoms were created from fused images taken from head and chest-abdomen-pelvis CT exams of the same individuals (9-month and 4-year phantoms) or of two different individuals of the same sex and similar age (8-year, 11-year, and 14-year phantoms). For each model, the resolution and slice positions of the image sets were adjusted based upon their anatomical coverage and then fused to a single head-torso image set. The resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year, and 14-year are 0.43 x 0.43 x 3.0 mm, 0.45 x 0.45 x 5.0 mm, 0.58 x 0.58 x 6.0 mm, 0.47 X 0.47 x 6.00 mm, and 0.625 x 0.625 x 6.0 mm, respectively. While organ masses can be matched to reference values in both stylized and tomographic phantoms, side-by-side comparisons of organ doses in both phantom classes indicate that organ shape and positioning are equally important parameters to consider in accurate determinations of organ absorbed dose from external photon irradiation. Preliminary studies of external photon irradiation of the 11-year phantom indicate significant departures of organ dose coefficients from that predicted by the existing stylized phantom series. Notable differences between pediatric stylized and tomographic phantoms include anterior-posterior (AP) and right lateral (RLAT) irradiation of the stomach wall, left lateral (LLAT) and right lateral (RLAT) irradiation of the thyroid, and AP and posterior-anterior (PA) irradiation of the urinary bladder.


Physics in Medicine and Biology | 2006

Whole-body voxel phantoms of paediatric patients--UF Series B.

Choonik Lee; Choonsik Lee; Jonathan L. Williams; Wesley E. Bolch

Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult (UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm x 0.86 mm x 3.0 mm, 0.90 mm x 0.90 mm x 5.0 mm, 1.16 mm x 1.16 mm x 6.0 mm, 0.94 mm x 0.94 mm x 6.00 mm and 1.18 mm x 1.18 mm x 6.72 mm, respectively.

Collaboration


Dive into the Choonsik Lee's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Steven L. Simon

National Institutes of Health

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kieran McHugh

Great Ormond Street Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Stephanie Lamart

National Institutes of Health

View shared research outputs
Researchain Logo
Decentralizing Knowledge