Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Christen Gray is active.

Publication


Featured researches published by Christen Gray.


The Journal of Infectious Diseases | 2013

Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria

Spencer D. Polley; Iveth J. González; Deqa Mohamed; Rosemarie Daly; Kathy Bowers; Julie Watson; Emma Mewse; Margaret Armstrong; Christen Gray; Mark D. Perkins; David Bell; Hidetoshi Kanda; Norihiro Tomita; Yutaka Kubota; Yasuyoshi Mori; Peter L. Chiodini; Colin J. Sutherland

Background. Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. Methods. The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum–specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. Results. A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. Conclusions. Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy.


PLOS ONE | 2012

Impact of Xpert MTB/RIF testing on tuberculosis management and outcomes in hospitalized patients in Uganda.

Christina Yoon; Adithya Cattamanchi; J. Lucian Davis; William Worodria; Saskia den Boon; Nelson Kalema; Winceslaus Katagira; Sylvia Kaswabuli; Cecily Miller; Alfred Andama; Heidi Albert; Pamela Nabeta; Christen Gray; Irene Ayakaka; Laurence Huang

Rationale The clinical impact of Xpert MTB/RIF for tuberculosis (TB) diagnosis in high HIV-prevalence settings is unknown. Objective To determine the diagnostic accuracy and impact of Xpert MTB/RIF among high-risk TB suspects. Methods We prospectively enrolled consecutive, hospitalized, Ugandan TB suspects in two phases: baseline phase in which Xpert MTB/RIF results were not reported to clinicians and an implementation phase in which results were reported. We determined the diagnostic accuracy of Xpert MTB/RIF in reference to culture (solid and liquid) and compared patient outcomes by study phase. Results 477 patients were included (baseline phase 287, implementation phase 190). Xpert MTB/RIF had high sensitivity (187/237, 79%, 95% CI: 73–84%) and specificity (190/199, 96%, 95% CI: 92–98%) for culture-positive TB overall, but sensitivity was lower (34/81, 42%, 95% CI: 31–54%) among smear-negative TB cases. Xpert MTB/RIF reduced median days-to-TB detection for all TB cases (1 [IQR 0–26] vs. 0 [IQR 0–1], p<0.001), and for smear-negative TB (35 [IQR 22–55] vs. 22 [IQR 0–33], p = 0.001). However, median days-to-TB treatment was similar for all TB cases (1 [IQR 0–5] vs. 0 [IQR 0–2], p = 0.06) and for smear-negative TB (7 [IQR 3–53] vs. 6 [IQR 1–61], p = 0.78). Two-month mortality was also similar between study phases among 252 TB cases (17% vs. 14%, difference +3%, 95% CI: −21% to +27%, p = 0.80), and among 87 smear-negative TB cases (28% vs. 22%, difference +6%, 95% CI: −34 to +46%, p = 0.77). Conclusions Xpert MTB/RIF facilitated more accurate and earlier TB diagnosis, leading to a higher proportion of TB suspects with a confirmed TB diagnosis prior to hospital discharge in a high HIV/low MDR TB prevalence setting. However, our study did not detect a decrease in two-month mortality following implementation of Xpert MTB/RIF possibly because of insufficient powering, differences in empiric TB treatment rates, and disease severity between study phases.


PLOS ONE | 2015

Use of Xpert MTB/RIF in Decentralized Public Health Settings and Its Effect on Pulmonary TB and DR-TB Case Finding in India

Kuldeep Singh Sachdeva; Neeraj Raizada; Achuthan Sreenivas; Anna H. van’t Hoog; Susan van den Hof; Puneet Dewan; Rahul Thakur; Radhey Shyam Gupta; Shubhangi Kulsange; Bhavin Vadera; Ameet Babre; Christen Gray; Malik Parmar; Mayank Ghedia; Umesh Alavadi; Nimalan Arinaminpathy; Claudia M. Denkinger; Catharina Boehme; C. N. Paramasivan

Background Xpert MTB/RIF, the first automated molecular test for tuberculosis, is transforming the diagnostic landscape in high-burden settings. This study assessed the impact of up-front Xpert MTB/RIF testing on detection of pulmonary tuberculosis (PTB) and rifampicin-resistant PTB (DR-TB) cases in India. Methods This demonstration study was implemented in 18 sub-district level TB programme units (TUs) in India in diverse geographic and demographic settings covering a population of 8.8 million. A baseline phase in 14 TUs captured programmatic baseline data, and an intervention phase in 18 TUs had Xpert MTB/RIF offered to all presumptive TB patients. We estimated changes in detection of TB and DR-TB, the former using binomial regression models to adjust for clustering and covariates. Results In the 14 study TUs, which participated in both phases, 10,675 and 70,556 presumptive TB patients were enrolled in the baseline and intervention phase, respectively, and 1,532 (14.4%) and 14,299 (20.3%) bacteriologically confirmed PTB cases were detected. The implementation of Xpert MTB/RIF was associated with increases in both notification rates of bacteriologically confirmed TB cases (adjusted incidence rate ratio [aIRR] 1.39; CI 1.18-1.64), and proportion of bacteriological confirmed TB cases among presumptive TB cases (adjusted risk ratio (aRR) 1.33; CI 1.6-1.52). Compared with the baseline strategy of selective drug-susceptibility testing only for PTB cases at high risk of drug-resistant TB, Xpert MTB/RIF implementation increased rifampicin resistant TB case detection by over fivefold. Among, 2765 rifampicin resistance cases detected, 1055 were retested with conventional drug susceptibility testing (DST). Positive predictive value (PPV) of rifampicin resistance detected by Xpert MTB/RIF was 94.7% (CI 91.3-98.1), in comparison to conventional DST. Conclusion Introduction of Xpert MTB/RIF as initial diagnostic test for TB in public health facilities significantly increased case-notification rates of all bacteriologically confirmed TB by 39% and rifampicin-resistant TB case notification by fivefold.


PLOS ONE | 2014

Feasibility of Decentralised Deployment of Xpert MTB/RIF Test at Lower Level of Health System in India

Neeraj Raizada; Kuldeep Singh Sachdeva; Achuthan Sreenivas; Bhavin Vadera; Radhey Shyam Gupta; Malik Parmar; Shubhangi Kulsange; Ameet Babre; Rahul Thakur; Christen Gray; Umesh Alavadi; Mayank Ghedia; Balasangameshwara Vollepore; Puneet Dewan; Catharina Boehme; Chinnambedu Nainarappan Paramsivan

Background Xpert MTB/RIF is an automated cartridge-based nucleic acid amplification test that has demonstrated its potential to detect tuberculosis and rifampicin resistance with high accuracy. To assist scale-up decisions in India, a feasibility assessment of Xpert MTB/RIF implementation was conducted within microscopy centres of 18 RNTCP TB units. Methods As part of programme-based demonstration of Xpert MTB/RIF implementation, we recorded and analysed association between key implementation factors and the ability of test to produce valid results. Factors contributing to test failures were analysed from GeneXpert software data which provides ‘failure codes’ and causes for test failures. Results From March’12 to January’13, total 40,035 suspects were tested by Xpert MTB/RIF, and 39,680 (99.1%) received valid results (Cumulative: 37157 (92.8%) on first attempt, 39410 (98.4%) on second attempt, 39637 (99.0%) on third attempt and 39680 (99.1%) on more attempts). Overall initial test failure was 2,878 (7.2% (4%–17%)); of these, 2,594 (90.1%) were re-tested and produced valid results. Most frequent reason of test failure was inadequate sample processing or equipment malfunction (3.9%). Other reasons included power failure (1.1%), cartridge integrity/component failure (0.8%), device-computer communication error (0.5%), and temperature-related errors (0.08%). Significant variation was observed in failure rates both across instruments and over time; furthermore, substantial variation was observed in failure rate in two cartridges lots. Conclusion Installation required minimal infrastructure modifications and concerns about adequacy of human resources under public sector facilities and temperature extremes proved unfounded. Under routine conditions, Xpert MTB/RIF provided 99.1% valid results in TB suspects with low overall failure rates (7.2% initial failure, 0.9% final failure); devices provided valuable real-time feedback on reasons for test failure, which were used for rapid corrective action. High modular replacement (32%) and inter-lot cartridge performance variation remain sources of concern, and warrant close monitoring of failure rates as a key quality indicator.


PLOS ONE | 2012

Evaluation of genotype MTBDRsl assay to detect drug resistance associated with fluoroquinolones, aminoglycosides and ethambutol on clinical sediments.

Kanchan Ajbani; Chaitali Nikam; Mubin Kazi; Christen Gray; Catharina Boehme; Kavita Balan; Anjali Shetty; Camilla Rodrigues

Background The emergence of resistant tuberculosis (TB) is a major setback to the global control of the disease as the treatment of such resistance is complex and expensive. Use of direct detection of mutations by molecular methods could facilitate rapid diagnosis of resistance to offset diagnostic delays. We evaluated the performance of the Genotype MTBDRsl (Hain Life Sciences) for the detection of second line resistant TB directly from stored smear positive sputum sediments. Methodology/Principal Findings The assay showed a diverse range of sensitivity and specificity, 91.26% [95% CI, 84–96] and 95.5% [95% CI, 87–99] for FQ (PPV ∼97% & NPV ∼ 87.67%), 56.19% [95%CI, 46–66] and 81% [95%CI, 66–91] for EMB (PPV ∼ 88.06% & NPV ∼ 43.21%) and 100% for SLD. Diagnostic accuracy for FQ, SLD and EMB was 94%, 100% and 63.51%, respectively. 1.17% (2/170) were heteroresistance strains, where the heteroresistance was linked to rrs gene. A varying rate of validity was observed 100% (170/170) for FQ, 94.11% (160/170) for EMB, 88.23% (150/170) for SLD. Conclusions/Significance Genotype MTBDRsl is simple, rapid, economical assay that can be used to detect commonly known resistance associated with Fluoroquinolone, second line injectable drugs and ethambutol. The assay detects the targeted resistance in less time as compared to phenotypic DST. But due to low NPV to FQ (88%) and EMB (43.21%), the assay results must be interpreted in coordination with the phenotypic DST.


PLOS ONE | 2014

Enhancing TB Case Detection: Experience in Offering Upfront Xpert MTB/RIF Testing to Pediatric Presumptive TB and DR TB Cases for Early Rapid Diagnosis of Drug Sensitive and Drug Resistant TB

Neeraj Raizada; Kuldeep Singh Sachdeva; Sreenivas Achuthan Nair; Shubhangi Kulsange; Radhey Shayam Gupta; Rahul Thakur; Malik Parmar; Christen Gray; Bhavin Vadera; Shobha Ekka; Shikha Dhawan; Ameet Babre; Mayank Ghedia; Umesh Alavadi; Puneet Dewan; Mini Khetrapal; Ashwini Khanna; Catharina Boehme; Chinnambedu Nainarappan Paramsivan

Background Diagnosis of pulmonary tuberculosis (PTB) in children is challenging due to difficulties in obtaining good quality sputum specimens as well as the paucibacillary nature of disease. Globally a large proportion of pediatric tuberculosis (TB) cases are diagnosed based only on clinical findings. Xpert MTB/RIF, a highly sensitive and specific rapid tool, offers a promising solution in addressing these challenges. This study presents the results from pediatric groups taking part in a large demonstration study wherein Xpert MTB/RIF testing replaced smear microscopy for all presumptive PTB cases in public health facilities across India. Methods The study covered a population of 8.8 million across 18 programmatic sub-district level tuberculosis units (TU), with one Xpert MTB/RIF platform established at each study TU. Pediatric presumptive PTB cases (both TB and Drug Resistant TB (DR-TB)) accessing any public health facilities in study area were prospectively enrolled and tested on Xpert MTB/RIF following a standardized diagnostic algorithm. Results 4,600 pediatric presumptive pulmonary TB cases were enrolled. 590 (12.8%, CI 11.8–13.8) pediatric PTB were diagnosed. Overall 10.4% (CI 9.5–11.2) of presumptive PTB cases had positive results by Xpert MTB/RIF, compared with 4.8% (CI 4.2–5.4) who had smear-positive results. Upfront Xpert MTB/RIF testing of presumptive PTB and presumptive DR-TB cases resulted in diagnosis of 79 and 12 rifampicin resistance cases, respectively. Positive predictive value (PPV) for rifampicin resistance detection was high (98%, CI 90.1–99.9), with no statistically significant variation with respect to past history of treatment. Conclusion Upfront access to Xpert MTB/RIF testing in pediatric presumptive PTB cases was associated with a two-fold increase in bacteriologically-confirmed PTB, and increased detection of rifampicin-resistant TB cases under routine operational conditions across India. These results suggest that routine Xpert MTB/RIF testing is a promising solution to present-day challenges in the diagnosis of PTB in pediatric patients.


Journal of Clinical Microbiology | 2016

Feasibility and Operational Performance of Tuberculosis Detection by Loop-Mediated Isothermal Amplification Platform in Decentralized Settings: Results from a Multicenter Study

Christen Gray; Achilles Katamba; Pratibha Narang; Jorge Giraldo; Carlos Zamudio; Moses Joloba; Rahul Narang; C. N. Paramasivan; Doris Hillemann; Pamela Nabeta; Danielle Amisano; David Alland; Frank Cobelens; Catharina Boehme

ABSTRACT Currently available nucleic acid amplification platforms for tuberculosis (TB) detection are not designed to be simple or inexpensive enough to implement in decentralized settings in countries with a high burden of disease. The loop-mediated isothermal amplification platform (LAMP) may change this. We conducted a study in adults with symptoms suggestive of TB in India, Uganda, and Peru to establish the feasibility of using TB-LAMP (Eiken Chemical Co.) in microscopy laboratories compared with using smear microscopy against a reference standard of solid and liquid cultures. Operational characteristics were evaluated as well. A total of 1,777 participants met the eligibility criteria and were included for analysis. Overall, TB-LAMP sensitivities among culture-positive samples were 97.2% (243/250; 95% confidence interval [CI], 94.3% to 98.2%) and 62.0% (88/142; 95% CI, 53.5% to 70.0%) for smear-positive and smear-negative TB, respectively, but varied widely by country and operator. Specificities ranged from 94.5% (446/472; 95% CI, 92.0% to 96.4%) to 98.0% (350/357; 95% CI, 96.0% to 99.2%) by country. A root cause analysis identified high temperatures, high humidity, and/or low reaction volumes as possible causes for false-positive results, as they may result in nonspecific amplification. The study was repeated in India with training focused on vulnerable steps and an updated protocol; 580 participants were included for analysis. Specificity in the repeat trial was 96.6% (515/533; 95% CI, 94.7% to 97.9%). To achieve acceptable performance of LAMP at the microscopy center level, significant training and infrastructure requirements are necessary.


Clinical Infectious Diseases | 2017

Diagnostic Performance of Tuberculosis-Specific IgG Antibody Profiles in Patients with Presumptive Tuberculosis from Two Continents

Tobias Broger; Robindra Basu Roy; Angela Filomena; Charles Greef; Stefanie Rimmele; Joshua Havumaki; David Danks; Nicole Schneiderhan-Marra; Christen Gray; Mahavir Singh; Ida Rosenkrands; Peter Andersen; Gregory M. Husar; Thomas O. Joos; Maria Laura Gennaro; Michael J. Lochhead; Claudia M. Denkinger; Mark Perkins

Summary Samples from >750 patients with presumptive TB in two continents were tested with a field-based IgG serological assay incorporating 57 M. tuberculosis antigens, and showed that responses to single antigens or multiple antigen sets have no clinically useful discriminating power.


International Journal of Infectious Diseases | 2018

Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study

Thu Hang Pham; Jonathan C. Peter; Fernanda Carvalho de Queiroz Mello; Tommy Parraga; Nguyen Thi Ngoc Lan; Pamela Nabeta; Eloise Valli; Tatiana Caceres; Keertan Dheda; Susan E. Dorman; Doris Hillemann; Christen Gray; Mark D. Perkins

Abstract Objective To evaluate the diagnostic performance of TB-LAMP, a manual molecular tuberculosis (TB) detection method, and provide comparison to the Xpert MTB/RIF assay. Methods In a large multicentre study, two sputum samples were collected from participants with TB symptoms in reference laboratories in Peru, South Africa, Brazil, and Vietnam. Each sample was tested with TB-LAMP. The reference standard consisted of four direct smears, four cultures, and clinical and radiological findings. Individuals negative on conventional tests were followed up after 8 weeks. The Xpert MTB/RIF assay was performed on fresh or frozen samples as a molecular test comparison. Results A total of 1036 adults with suspected TB were enrolled. Among 375 culture-confirmed TB cases with 750 sputum samples, TB-LAMP detected 75.6% (95% confidence interval (CI) 71.8–79.4%), including 97.9% (95% CI 96.4–99.4%) of smear-positive TB samples and 46.6% (95% CI 40.6–52.7%) of smear-negative TB samples. Specificity in 477 culture-negative participants not treated for TB (954 sputum samples) was 98.7% (95% CI 97.9–99.6%). TB-LAMP test results were indeterminate in 0.3% of cases. Conclusions TB-LAMP detects nearly all smear-positive and half of smear-negative TB cases and has a high specificity when performed in reference laboratories. Performance was similar to the Xpert MTB/RIF assay.


The Lancet | 2011

Feasibility, diagnostic accuracy, and effectiveness of decentralised use of the Xpert MTB/RIF test for diagnosis of tuberculosis and multidrug resistance: a multicentre implementation study

Catharina Boehme; Mark P. Nicol; Pamela Nabeta; Joy Sarojini Michael; Eduardo Gotuzzo; Rasim Tahirli; Ma Tarcela Gler; Robert Blakemore; William Worodria; Christen Gray; Laurence Huang; Tatiana Caceres; Rafail Mehdiyev; Lawrence W. Raymond; Andrew Whitelaw; Kalaiselvan Sagadevan; Heather Alexander; Heidi Albert; Frank Cobelens; Helen Cox; David Alland; Mark D. Perkins

Collaboration


Dive into the Christen Gray's collaboration.

Top Co-Authors

Avatar

Catharina Boehme

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Pamela Nabeta

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Ameet Babre

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Bhavin Vadera

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Mark D. Perkins

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Neeraj Raizada

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Rahul Thakur

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Shubhangi Kulsange

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar

Umesh Alavadi

Foundation for Innovative New Diagnostics

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge