Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Christian Nemoz is active.

Publication


Featured researches published by Christian Nemoz.


International Symposium on Optical Science and Technology | 2001

Weanling piglet cerebellum: a surrogate for tolerance to MRT (microbeam radiation therapy) in pediatric neuro-oncology

Jean A. Laissue; Hans Blattmann; Marco Di Michiel; Daniel N. Slatkin; Nadia Lyubimova; Raphael Guzman; Werner Zimmermann; Stephan Birrer; Tim Bley; Patrick Kircher; Regina Stettler; Rosmarie Fatzer; A. Jaggy; Henry M. Smilowitz; Elke Brauer; Alberto Bravin; Géraldine Le Duc; Christian Nemoz; M. Renier; W Thomlinson; Jiri Stepanek; Hans-Peter Wagner

The cerebellum of the weanling piglet (Yorkshire) was used as a surrogate for the radiosensitive human infant cerebellum in a Swiss-led program of experimental microbeam radiation therapy (MRT) at the ESRF. Five weanlings in a 47 day old litter of seven, and eight weanlings in a 40 day old litter of eleven were irradiated in November, 1999 and June, 2000, respectively. A 1.5 cm-wide x 1.5 xm-high array of equally space approximately equals 20-30 micrometers wide, upright microbeams spaced at 210 micrometers intervals was propagated horizontally, left to right, through the cerebella of the prone, anesthetized piglets. Skin-entrance intra-microbeam peak adsorbed doses were uniform, either 150, 300, 425, or 600 gray (Gy). Peak and inter-microbeam (valley) absorbed doses in the cerebellum were computed with the PSI version of the Monte Carlo code GEANT and benchmarked using Gafchromic and radiochromic film microdosimetry. For approximately equals 66 weeks [first litter; until euthanasia], or approximately equals 57 weeks [second litter; until July 30, 2001] after irradiation, the littermates were developmentally, behaviorally, neurologically and radiologically normal as observed and tested by experienced farmers and veterinary scientists unaware of which piglets were irradiated or sham-irradiated. Morever, MRT implemented at the ESRF with a similar array of microbeams and a uniform skin-entrance peak dose of 625 Gy, followed by immunoprophylaxis, was shown to be palliative or curative in young adult rats bearing intracerebral gliosarcomas. These observations give further credence to MRTs potential as an adjunct therapy for brain tumors in infancy, when seamless therapeutic irradiation of the brain is hazardous.


Physics in Medicine and Biology | 2007

High-resolution CT by diffraction-enhanced x-ray imaging : mapping of breast tissue samples and comparison with their histo-pathology

Alberto Bravin; Jani Keyriläinen; Manuel Fernández; Stefan Fiedler; Christian Nemoz; Marja-Liisa Karjalainen-Lindsberg; Mikko Tenhunen; Pekka Virkkunen; Marjut Leidenius; Karl von Smitten; Petri Sipilä; Pekka Suortti

The aim of this study was to introduce high-resolution computed tomography (CT) of breast tumours using the diffraction-enhanced x-ray imaging (DEI) technique and to compare results with radiological and histo-pathological examinations. X-ray CT images of tumour-bearing breast tissue samples were acquired by monochromatic synchrotron radiation (SR). Due to the narrow beam and a large sample-to-detector distance scattering is rejected in the absorption contrast images (SR-CT). Large contrast enhancement is achieved by the use of the DEI-CT method, where the effects of refraction and scatter rejection are analysed by crystal optics. Clinical mammograms and CT images were recorded as reference material for a radiological examination. Three malignant and benign samples were studied in detail. Their radiographs were compared with optical images of stained histological sections. The DEI-CT images map accurately the morphology of the samples, including collagen strands and micro-calcifications of dimensions less than 0.1 mm. Histo-pathological examination and reading of the radiographs were done independently, and the conclusions were in general agreement. High-resolution DEI-CT images show strong contrast and permit visualization of details invisible in clinical radiographs. The radiation dose may be reduced by an order of magnitude without compromising image quality, which would make possible clinical in vivo DEI-CT with future compact SR sources.


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 1999

Instrumentation of the ESRF medical imaging facility

Hélène Elleaume; A. M. Charvet; P. Berkvens; Gilles Berruyer; Thierry Brochard; Y. Dabin; M.C. Dominguez; A. Draperi; Stefan Fiedler; G. Goujon; G. Le Duc; M. Mattenet; Christian Nemoz; M. Perez; M. Renier; C. Schulze; P. Spanne; P. Suortti; W. Thomlinson; F. Estève; Bernard Bertrand; J.F. Le Bas

Abstract At the European Synchrotron Radiation Facility (ESRF) a beamport has been instrumented for medical research programs. Two facilities have been constructed for alternative operation. The first one is devoted to medical imaging and is focused on intravenous coronary angiography and computed tomography (CT). The second facility is dedicated to pre-clinical microbeam radiotherapy (MRT). This paper describes the instrumentation for the imaging facility. Two monochromators have been designed, both are based on bent silicon crystals in the Laue geometry. A versatile scanning device has been built for pre-alignment and scanning of the patient through the X-ray beam in radiography or CT modes. An intrinsic germanium detector is used together with large dynamic range electronics (16 bits) to acquire the data. The beamline is now at the end of its commissioning phase; intravenous coronary angiography is intended to start in 1999 with patients and the CT pre-clinical program is underway on small animals. The first in vivo images obtained on animals in angiography and CT modes are presented to illustrate the performances of these devices.


Physics in Medicine and Biology | 2001

Quantitative functional lung imaging with synchrotron radiation using inhaled xenon as contrast agent

S Bayat; G. Le Duc; Liisa Porra; Gilles Berruyer; Christian Nemoz; S. Monfraix; Stefan Fiedler; W Thomlinson; Pekka Suortti; C G Standertskjöld-Nordenstam; Anssi Sovijärvi

Small airways play a key role in the distribution of ventilation and in the matching of ventilation to perfusion. The purpose of this study was to introduce an imaging method that allows measurement of regional lung ventilation and evaluation of the function of airways with a small diameter. The experiments were performed at the Medical Beamline of the European Synchrotron Radiation Facility. Monochromatic synchrotron radiation beams were used to obtain quantitative respiration-gated images of lungs and airways in two anaesthetized and mechanically ventilated rabbits using inhaled stable xenon (Xe) gas as a contrast agent. Two simultaneous images were acquired at two different energies, above and below the K-edge of Xe. Logarithmic subtraction of the two images yields absolute Xe concentrations. This technique is known as K-edge subtraction (KES) radiography. Two-dimensional planar and CT images were obtained showing spatial distribution of Xe concentrations within the airspaces, as well as the dynamics of filling with Xe. Bronchi down to 1 mm in diameter were visible both in the subtraction radiographs and in tomographic images. Absolute concentrations of Xe gas were calculated within the tube carrying the inhaled gas mixture, small and large bronchi, and lung tissue. Local time constants of ventilation with Xe were obtained by following the evolution of gas concentration in sequential computed tomography images. The results of this first animal study indicate that KES imaging of lungs with Xe gas as a contrast agent has great potential in studies of the distribution of ventilation within the lungs and of airway function, including airways with a small diameter.


Physics in Medicine and Biology | 2005

Quantitative measurement of regional lung gas volume by synchrotron radiation computed tomography

S. Monfraix; S Bayat; Liisa Porra; Gilles Berruyer; Christian Nemoz; William Thomlinson; Pekka Suortti; Anssi Sovijärvi

The aim of this study was to assess the feasibility of a novel respiration-gated spiral synchrotron radiation computed tomography (SRCT) technique for direct quantification of absolute regional lung volumes, using stable xenon (Xe) gas as an inhaled indicator. Spiral SRCT with K-edge subtraction using two monochromatic x-ray beams was used to visualize and directly quantify inhaled Xe concentrations and airspace volumes in three-dimensional (3D) reconstructed lung images. Volume measurements were validated using a hollow Xe-filled phantom. Spiral images spanning 49 mm in lung height were acquired following 60 breaths of an 80% Xe-20% O2 gas mixture, in two anaesthetized and mechanically ventilated rabbits at baseline and after histamine aerosol inhalation. Volumetric images of 20 mm lung sections were obtained at functional residual capacity (FRC) and at end-inspiration. 3D images showed large patchy filling defects in peripheral airways and alveoli following histamine provocation. Local specific lung compliance was calculated based on FRC/end-inspiration images in normal lung. This study demonstrates spiral SRCT as a new technique for direct determination of regional lung volume, offering possibilities for non-invasive investigation of regional lung function and mechanics, with a uniquely high spatial resolution. An example of non-uniform volume distribution in rabbit lung following histamine inhalation is presented.


Physics in Medicine and Biology | 2000

First human transvenous coronary angiography at the European Synchrotron Radiation Facility

Hélène Elleaume; Stefan Fiedler; F. Estève; Bernard Bertrand; A. M. Charvet; P. Berkvens; Gilles Berruyer; Thierry Brochard; G. Le Duc; Christian Nemoz; M. Renier; P. Suortti; W Thomlinson; J.F. Le Bas

The first operation of the European Synchrotron Radiation Facility (ESRF) medical beamline is reported in this paper. The goal of the angiography project is to develop a reduced risk imaging technique, which can be used to follow up patients after coronary intervention. After the intravenous injection of a contrast agent (iodine) two images are produced with monochromatic beams, bracketing the iodine K-edge. The logarithmic subtraction of the two measurements results in an iodine enhanced image, which can be precisely quantified. A research protocol has been designed to evaluate the performances of this method in comparison with the conventional technique. Patients included in the protocol have previously undergone angioplasty. If a re-stenosis is suspected, the patient is imaged both at the ESRF and at the hospital with the conventional technique, within the next few days. This paper reports the results obtained with the first patients. To date, eight patients have been imaged and excellent image quality was obtained.


SPIE's International Symposium on Optical Science, Engineering, and Instrumentation | 1999

Microbeam radiation therapy

Jean A. Laissue; Nadia Lyubimova; Hans-Peter Wagner; David W. Archer; Daniel N. Slatkin; Marco Di Michiel; Christian Nemoz; M. Renier; Elke Brauer; Per O. Spanne; Jan-Olef Gebbers; Keith Dixon; Hans Blattmann

The central nervous system of vertebrates, even when immature, displays extraordinary resistance to damage by microscopically narrow, multiple, parallel, planar beams of x rays. Imminently lethal gliosarcomas in the brains of mature rats can be inhibited and ablated by such microbeams with little or no harm to mature brain tissues and neurological function. Potentially palliative, conventional wide-beam radiotherapy of malignant brain tumors in human infants under three years of age is so fraught with the danger of disrupting the functional maturation of immature brain tissues around the targeted tumor that it is implemented infrequently. Other kinds of therapy for such tumors are often inadequate. We suggest that microbeam radiation therapy (MRT) might help to alleviate the situation. Wiggler-generated synchrotron x-rays were first used for experimental microplanar beam (microbeam) radiation therapy (MRT) at Brookhaven National Laboratorys National Synchrotron Light Source in the early 1990s. We now describe the progress achieved in MRT research to date using immature and adult rats irradiated at the European Synchrotron Radiation Facility in Grenoble, France, and investigated thereafter at the Institute of Pathology of the University of Bern.


PLOS ONE | 2010

High-Precision Radiosurgical Dose Delivery by Interlaced Microbeam Arrays of High-Flux Low-Energy Synchrotron X-Rays

Raphaël Serduc; Elke Bräuer-Krisch; Erik Albert Siegbahn; Audrey Bouchet; Benoit Pouyatos; Romain Carron; Nicolas Pannetier; Luc Renaud; Gilles Berruyer; Christian Nemoz; Thierry Brochard; Chantal Rémy; Emmanuel L. Barbier; Alberto Bravin; Géraldine Le Duc; Antoine Depaulis; François Estève; Jean A. Laissue

Microbeam Radiation Therapy (MRT) is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very high radiation doses (hundreds of Gy). Based on this well described normal tissue sparing effect of microplanar beams, we developed a new irradiation geometry which allows the delivery of a high uniform dose deposition at a given brain target whereas surrounding normal tissues are irradiated by well tolerated parallel microbeams only. Normal rat brains were exposed to 4 focally interlaced arrays of 10 microplanar beams (52 µm wide, spaced 200 µm on-center, 50 to 350 keV in energy range), targeted from 4 different ports, with a peak entrance dose of 200Gy each, to deliver an homogenous dose to a target volume of 7 mm3 in the caudate nucleus. Magnetic resonance imaging follow-up of rats showed a highly localized increase in blood vessel permeability, starting 1 week after irradiation. Contrast agent diffusion was confined to the target volume and was still observed 1 month after irradiation, along with histopathological changes, including damaged blood vessels. No changes in vessel permeability were detected in the normal brain tissue surrounding the target. The interlacing radiation-induced reduction of spontaneous seizures of epileptic rats illustrated the potential pre-clinical applications of this new irradiation geometry. Finally, Monte Carlo simulations performed on a human-sized head phantom suggested that synchrotron photons can be used for human radiosurgical applications. Our data show that interlaced microbeam irradiation allows a high homogeneous dose deposition in a brain target and leads to a confined tissue necrosis while sparing surrounding tissues. The use of synchrotron-generated X-rays enables delivery of high doses for destruction of small focal regions in human brains, with sharper dose fall-offs than those described in any other conventional radiation therapy.


Radiation Research | 2002

Lack of Cell Death Enhancement after Irradiation with Monochromatic Synchrotron X Rays at the K-Shell Edge of Platinum Incorporated in Living SQ20B Human Cells as cis-Diamminedichloroplatinum (II)

Stéphanie Corde; Marie-Claude Biston; Hélène Elleaume; F. Estève; A. M. Charvet; A. Joubert; V. Ducros; S. Bohic; A. Simionovici; Thierry Brochard; Christian Nemoz; M. Renier; Irène Troprès; Stephan Fiedler; Alberto Bravin; W. Thomlinson; J.F. Le Bas; Jacques Balosso

Abstract Corde, S., Biston, M. C., Elleaume, H., Estève, F., Charvet, A. M., Joubert, A., Ducros, V., Bohic, S., Simionovici, A., Brochard, T., Nemoz, C., Renier, Troprès, I., Fiedler, S., Bravin, A., M., Thomlinson, W., Le Bas, J. F. and Balosso, J. Lack of Cell Death Enhancement after Irradiation with Monochromatic Synchrotron X Rays at the K-Shell Edge of Platinum Incorporated in Living SQ20B Human Cells as cis-Diamminedichloroplatinum (II). Radiat. Res. 158, 763–770 (2002). In this paper we describe the results of experiments using synchrotron radiation to trigger the Auger effect in living human cancer cells treated with a widely used chemotherapy drug: cis-diamminedichloroplatinum (II) (cisplatin). The experiments were carried out at the ID17 beamline of the European Synchrotron Radiation Facility, which produces a high-fluence monochromatic beam that is adjustable from 20 to 80 keV. Cisplatin was chosen as the carrier of platinum atoms in the cells because of its alkylating-like activity and the irradiation was done with monochromatic beams above and below the platinum K-shell edge (78.39 keV). Cell survival curves were comparable with those obtained for the same cells under conventional irradiation conditions. At a low dose of cisplatin (0.1 μM, 48 h), no difference was seen in survival when the cells were irradiated above and below the K-shell edge of platinum. Higher cisplatin concentrations were investigated to enhance the cellular platinum content. The results with 1 μM cisplatin for 12 h showed no difference when the cells were irradiated with beams above or below the platinum K-shell edge with the exception of the higher cell death resulting from drug toxicity. The intracellular content of platinum was significant, as measured macroscopically by inductively coupled plasma mass spectrometry. Its subcellular localization and particularly its presence in the cell nucleus were verified by microscopic synchrotron X-ray fluorescence. This was the first known attempt at K-shell edge photon activation of stable platinum in living cells with a platinum complex used for chemotherapy. Its evident toxicity in these cells leads us to put forth the hypothesis that cisplatin toxicity can mask the enhancement of cell death induced by the irradiation above the K-shell edge. However, K-shell edge photon activation of stable elements provides a powerful technique for the understanding of the biological effects of Auger processes. Further avenues of development are discussed.


European Journal of Radiology | 2008

The radiotherapy clinical trials projects at the ESRF: Technical aspects

M. Renier; Th. Brochard; Christian Nemoz; Herwig Requardt; E. Bräuer; François Estève; J. Balosso; P. Suortti; J. Baruchel; Hélène Elleaume; G. Berruyer; P. Berkvens; Alberto Bravin

The radiotherapy clinical trials projects, both aiming at treating aggressive brain tumors, require several major modifications and new constructions at the ESRF ID17 Biomedical beamline. The application of the Stereotactic Synchrotron Radiation Therapy (SSRT) technique mainly necessitates an upgrade of the existing patient positioning system, which was formerly used for the angiography program. It will allow for accurate positioning, translation and rotation of the patient during the treatment. For the Microbeam Radiation Therapy (MRT) clinical trials project, a new white beam hutch will be constructed to accommodate a dedicated patient positioning system. Consequently, the existing control hutches and the related installations will also be completely refurbished. Furthermore, the foreseen installation of a second X-ray source, which will allow doubling the currently available photon flux at high energies, requires a redesign of most optical components to handle the increased power and power densities. Starting from the current ID17 Biomedical beamline layout, the paper will present an update of the different modification/construction projects, including the general organization and planning.

Collaboration


Dive into the Christian Nemoz's collaboration.

Top Co-Authors

Avatar

M. Renier

European Synchrotron Radiation Facility

View shared research outputs
Top Co-Authors

Avatar

Thierry Brochard

European Synchrotron Radiation Facility

View shared research outputs
Top Co-Authors

Avatar

Alberto Bravin

European Synchrotron Radiation Facility

View shared research outputs
Top Co-Authors

Avatar

Gilles Berruyer

European Synchrotron Radiation Facility

View shared research outputs
Top Co-Authors

Avatar

P. Berkvens

European Synchrotron Radiation Facility

View shared research outputs
Top Co-Authors

Avatar

Elke Bräuer-Krisch

European Synchrotron Radiation Facility

View shared research outputs
Top Co-Authors

Avatar

F. Estève

Joseph Fourier University

View shared research outputs
Top Co-Authors

Avatar

Stefan Fiedler

European Synchrotron Radiation Facility

View shared research outputs
Top Co-Authors

Avatar

W Thomlinson

European Synchrotron Radiation Facility

View shared research outputs
Top Co-Authors

Avatar

Géraldine Le Duc

European Synchrotron Radiation Facility

View shared research outputs
Researchain Logo
Decentralizing Knowledge