Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Chun Yuh Huang is active.

Publication


Featured researches published by Chun Yuh Huang.


Journal of Biomechanical Engineering-transactions of The Asme | 2001

The role of flow-independent viscoelasticity in the biphasic tensile and compressive responses of articular cartilage

Chun Yuh Huang; Van C. Mow; Gerard A. Ateshian

A long-standing challenge in the biomechanics of connective tissues (e.g., articular cartilage, ligament, tendon) has been the reported disparities between their tensile and compressive properties. In general, the intrinsic tensile properties of the solid matrices of these tissues are dictated by the collagen content and microstructural architecture, and the intrinsic compressive properties are dictated by their proteoglycan content and molecular organization as well as water content. These distinct materials give rise to a pronounced and experimentally well-documented nonlinear tension-compression stress-strain responses, as well as biphasic or intrinsic extracellular matrix viscoelastic responses. While many constitutive models of articular cartilage have captured one or more of these experimental responses, no single constitutive law has successfully described the uniaxial tensile and compressive responses of cartilage within the same framework. The objective of this study was to combine two previously proposed extensions of the biphasic theory of Mow et al. [1980, ASME J. Biomech. Eng., 102, pp. 73-84] to incorporate tension-compression nonlinearity as well as intrinsic viscoelasticity of the solid matrix of cartilage. The biphasic-conewise linear elastic model proposed by Soltz and Ateshian [2000, ASME J. Biomech. Eng., 122, pp. 576-586] and based on the bimodular stress-strain constitutive law introduced by Curnier et al. [1995, J. Elasticity, 37, pp. 1-38], as well as the biphasic poroviscoelastic model of Mak [1986, ASME J. Biomech. Eng., 108, pp. 123-130], which employs the quasi-linear viscoelastic model of Fung [1981, Biomechanics: Mechanical Properties of Living Tissues, Springer-Verlag, New York], were combined in a single model to analyze the response of cartilage to standard testing configurations. Results were compared to experimental data from the literature and it was found that a simultaneous prediction of compression and tension experiments of articular cartilage, under stress-relaxation and dynamic loading, can be achieved when properly taking into account both flow-dependent and flow-independent viscoelasticity effects, as well as tension-compression nonlinearity.


Journal of Biomechanical Engineering-transactions of The Asme | 2003

Experimental Verification of the Roles of Intrinsic Matrix Viscoelasticity and Tension-Compression Nonlinearity in the Biphasic Response of Cartilage

Chun Yuh Huang; Michael A. Soltz; Monika Kopacz; Van C. Mow; Gerard A. Ateshian

A biphasic-CLE-QLV model proposed in our recent study [2001, J. Biomech. Eng., 123, pp. 410-417] extended the biphasic theory of Mow et al. [1980, J. Biomech. Eng., 102, pp. 73-84] to include both tension-compression nonlinearity and intrinsic viscoelasticity of the cartilage solid matrix by incorporating it with the conewise linear elasticity (CLE) model [1995, J. Elasticity, 37, pp. 1-38] and the quasi-linear viscoelasticity (QLV) model [Biomechanics: Its foundations and objectives, Prentice Hall, Englewood Cliffs, 1972]. This model demonstrates that a simultaneous prediction of compression and tension experiments of articular cartilage, under stress-relaxation and dynamic loading, can be achieved when properly taking into account both flow-dependent and flow-independent viscoelastic effects, as well as tension-compression nonlinearity. The objective of this study is to directly test this biphasic-CLE-QLV model against experimental data from unconfined compression stress-relaxation tests at slow and fast strain rates as well as dynamic loading. Twelve full-thickness cartilage cylindrical plugs were harvested from six bovine glenohumeral joints and multiple confined and unconfined compression stress-relaxation tests were performed on each specimen. The material properties of specimens were determined by curve-fitting the experimental results from the confined and unconfined compression stress relaxation tests. The findings of this study demonstrate that the biphasic-CLE-QLV model is able to describe the strain-rate-dependent mechanical behaviors of articular cartilage in unconfined compression as attested by good agreements between experimental and theoretical curvefits (r2 = 0.966 +/- 0.032 for testing at slow strain rate; r2 = 0.998 +/- 0.002 for testing at fast strain rate) and predictions of the dynamic response (r2 = 0.91 +/- 0.06). This experimental study also provides supporting evidence for the hypothesis that both tension-compression nonlinearity and intrinsic viscoelasticity of the solid matrix of cartilage are necessary for modeling the transient and equilibrium responses of this tissue in tension and compression. Furthermore, the biphasic-CLE-QLV model can produce better predictions of the dynamic modulus of cartilage in unconfined dynamic compression than the biphasic-CLE and biphasic poroviscoelastic models, indicating that intrinsic viscoelasticity and tension-compression nonlinearity of articular cartilage may play important roles in the load-support mechanism of cartilage under physiologic loading.


Stem Cells | 2005

Temporal Expression Patterns and Corresponding Protein Inductions of Early Responsive Genes in Rabbit Bone Marrow–Derived Mesenchymal Stem Cells Under Cyclic Compressive Loading

Chun Yuh Huang; Paul M. Reuben; Herman S. Cheung

Our recent study suggested that cyclic compressive loading may promote chondrogenesis of rabbit bone‐marrow mesenchymal stem cells (BM‐MSCs) in agarose cultures through the transforming growth factor (TGF)–β signaling pathway. It has been shown that the activating protein 1 (AP‐1) (Jun‐Fos) complex mediated autoinduction of TGF‐β1 and its binding activity was essential for promoting chondrogenesis of mesenchymal cells, whereas Sox9 was identified as an essential transcription factor for chondrogenesis of embryonic mesenchymal cells. The objective of this study was to examine temporal expression patterns of early responsive genes (Sox9, c‐Fos, c‐Jun, and TGF‐β type I and II receptors) and induction of their corresponding proteins in agarose culture of rabbit BM‐MSCs subjected to cyclic compressive loading. The rabbit BM‐MSCs were obtained from the tibias and femurs of New Zealand White rabbits. Cell‐agarose constructs were made by suspending BM‐MSCs in 2% agarose gel (107 cells/ml) for cyclic, unconfined compression tests performed in a custom‐made bioreactor. In the loading experiment, specimens were subjected to sinusoidal loading with a magnitude of 15% strain at a frequency of 1 hertz for 4 hours per day. Experiments were conducted for 2 consecutive days. This study showed that cyclic compressive loading promoted gene expressions of Sox9, c‐Jun, and both TGF‐β receptors and productions of their corresponding proteins, whereas those gene expressions exhibited different temporal expression patterns among genes and between 2 days of testing. The gene expression of c‐Fos was detected only in the samples subjected to1‐hour dynamic compressive loading. These findings suggest that the TGF‐β signal transduction and activities of AP‐1 and Sox9 are involved in the early stage of BM‐MSC chondrogenesis promoted by dynamic compressive loading.


Regenerative Medicine | 2009

Plasticity of stem cells derived from adult periodontal ligament

Chun Yuh Huang; Daniel Pelaez; Juan Dominguez Bendala; Franklin Garcia-Godoy; Herman S. Cheung

BACKGROUND The neural crest contains pluripotent cells that can give rise to neurons and glial cells of the peripheral nervous system, endocrine cells, connective tissue cells, muscle cells and pigment cells during embryonic development. Stem cells derived from the neural crest may still reside in neural crest derivatives including the periodontal ligament (PDL). However, the pluripotency of PDL-derived stem cells has not been investigated. AIM To identify subpopulations of stem cells from the adult PDL and study their pluripotency. Human PDLs were harvested from impacted wisdom teeth (patients aged 19-22 years). RESULTS This study demonstrated that subpopulations of PDL cells expressed embryonic stem cell markers (Oct4, Sox2, Nanog and Klf4) and a subset of neural crest markers (Nestin, Slug, p75 and Sox10). Such PDL cell subpopulations exhibited the potential to differentiate into neurogenic, cardiomyogenic, chondrogenic and osteogenic lineages. Furthermore, preliminary evidence suggesting insulin production of PDL cells might be indicative of the generation of cells of the endodermal lineage. CONCLUSION These findings suggest that the PDL may contain pluripotent stem cells that originate from the neural crest. Our observations open the door to prospective autologous therapeutic applications for a variety of conditions.


Journal of Biomechanics | 2008

Effects of mechanical compression on metabolism and distribution of oxygen and lactate in intervertebral disc

Chun Yuh Huang; Wei Yong Gu

The objective of this study was to examine the effects of mechanical compression on metabolism and distributions of oxygen and lactate in the intervertebral disc (IVD) using a new formulation of the triphasic theory. In this study, the cellular metabolic rates of oxygen and lactate were incorporated into the newly developed formulation of the mechano-electrochemical mixture model [Huang, C.-Y., Gu, W.Y., 2007. Effect of tension-compression nonlinearity on solute transport in charged hydrated fibrosus tissues under dynamic unconfined compression. Journal of Biomechanical Engineering 129, 423-429]. The model was used to numerically analyze metabolism and transport of oxygen and lactate in the IVD under static or dynamic compression. The theoretical analyses demonstrated that compressive loading could affect transport and metabolism of nutrients. Dynamic compression increased oxygen concentration, reduced lactate accumulation, and promoted oxygen consumption and lactate production (i.e., energy conversion) within the IVD. Such effects of dynamic loading were dependent on strain level and loading frequency, and more pronounced in the IVD with less permeable endplate. In contrast, static compression exhibited inverse effects on transport and metabolism of oxygen and lactate. The theoretical predictions in this study are in good agreement with those in the literature. This study established a new theoretical model for analyzing cellular metabolism of nutrients in hydrated, fibrous soft tissues under mechanical compression.


Spine | 2008

EFFECT OF COMPRESSION AND ANISOTROPY ON THE DIFFUSION OF GLUCOSE IN ANNULUS FIBROSUS

Alicia R. Jackson; Tai Yi Yuan; Chun Yuh Huang; Francesco Travascio; Wei Yong Gu

Study Design. Investigation of the effect of static compression and anisotropy on the apparent diffusivity of glucose in bovine annulus fibrosus (AF). Objective. To determine the apparent glucose diffusivity in 2 directions (axial and radial) of bovine AF under 3 levels of compressive strain (0%, 10%, and 20%). Summary of Background Data. Knowledge of diffusivity of small molecules is important for understanding nutritional supply in intervertebral discs and the mechanisms of disc degeneration. However, little is known regarding the strain-dependent and anisotropic behavior of glucose diffusivity in intervertebral discs. Methods. Apparent glucose diffusivity measurements were performed on 10 axial and 10 radial AF specimens from bovine coccygeal discs. The dependence of diffusivity on compression was determined using 3 levels of strain (0%, 10%, and 20%). Results. The apparent glucose diffusivity (mean ± standard deviation) of the bovine AF in the axial direction was 1.38 ± 0.015 × 10−6 cm2/s (n = 10) at 0%, 1.00 ± 0.070 × 10−6 cm2/s (n = 10) at 10%, and 7.65 ± 0.552 × 10−7 cm2/s (n = 10) at 20% compression. For radial specimens, the apparent glucose diffusivity was determined to be 9.17 ± 1.12 × 10−7 cm2/s (n = 10), 7.29 ± 0.863 × 10−7 cm2/s (n = 10), and 5.43 ± 1.16 × 10−7 cm2/s (n = 10) for 0%, 10%, and 20% compressions, respectively. A significant decrease in diffusivity with increasing strain was found for both axial and radial specimens [analysis of variance (ANOVA), P < 0.05]. Diffusion in the radial direction was determined to be significantly less than that in the axial direction (ANOVA, P < 0.05). A significant interaction was found between the level of strain and the direction of diffusion (ANOVA, P < 0.05). Conclusion. Diffusion of glucose in bovine AF is dependent on strain and the direction of diffusion.


Computer Methods in Biomechanics and Biomedical Engineering | 2011

Effect of endplate calcification and mechanical deformation on the distribution of glucose in intervertebral disc: a 3D finite element study

Alicia R. Jackson; Chun Yuh Huang; Wei Yong Gu

The intervertebral disc (IVD) is avascular, receiving nutrition from surrounding vasculature. Theoretical modelling can supplement experimental results to understand nutrition to IVD more clearly. A new, 3D finite element model of the IVD was developed to investigate effects of endplate calcification and mechanical deformation on glucose distributions in IVD. The model included anatomical disc geometry, non-linear coupling of cellular metabolism with pH and oxygen concentration and strain-dependent properties of the extracellular matrix. Calcification was simulated by reducing endplate permeability (∼79%). Mechanical loading was applied based on in vivo disc deformation during the transition from supine to standing positions. Three static strain conditions were considered: supine, standing and weight-bearing standing. Minimum glucose concentrations decreased 45% with endplate calcification, whereas disc deformation led to a 4.8–63% decrease, depending on the endplate condition (i.e. normal vs. calcified). Furthermore, calcification more strongly affected glucose concentrations in the nucleus compared to the annulus fibrous region. This study provides important insight into nutrient distributions in IVD under mechanical deformation.


Journal of Biomechanical Engineering-transactions of The Asme | 2011

3D Finite Element Analysis of Nutrient Distributions and Cell Viability in the Intervertebral Disc: Effects of Deformation and Degeneration

Alicia R. Jackson; Chun Yuh Huang; Mark D. Brown; Wei Yong Gu

The intervertebral disc (IVD) receives important nutrients, such as glucose, from surrounding blood vessels. Poor nutritional supply is believed to play a key role in disc degeneration. Several investigators have presented finite element models of the IVD to investigate disc nutrition; however, none has predicted nutrient levels and cell viability in the disc with a realistic 3D geometry and tissue properties coupled to mechanical deformation. Understanding how degeneration and loading affect nutrition and cell viability is necessary for elucidating the mechanisms of disc degeneration and low back pain. The objective of this study was to analyze the effects of disc degeneration and static deformation on glucose distributions and cell viability in the IVD using finite element analysis. A realistic 3D finite element model of the IVD was developed based on mechano-electrochemical mixture theory. In the model, the cellular metabolic activities and viability were related to nutrient concentrations, and transport properties of nutrients were dependent on tissue deformation. The effects of disc degeneration and mechanical compression on glucose concentrations and cell density distributions in the IVD were investigated. To examine effects of disc degeneration, tissue properties were altered to reflect those of degenerated tissue, including reduced water content, fixed charge density, height, and endplate permeability. Two mechanical loading conditions were also investigated: a reference (undeformed) case and a 10% static deformation case. In general, nutrient levels decreased moving away from the nutritional supply at the disc periphery. Minimum glucose levels were at the interface between the nucleus and annulus regions of the disc. Deformation caused a 6.2% decrease in the minimum glucose concentration in the normal IVD, while degeneration resulted in an 80% decrease. Although cell density was not affected in the undeformed normal disc, there was a decrease in cell viability in the degenerated case, in which averaged cell density fell 11% compared with the normal case. This effect was further exacerbated by deformation of the degenerated IVD. Both deformation and disc degeneration altered the glucose distribution in the IVD. For the degenerated case, glucose levels fell below levels necessary for maintaining cell viability, and cell density decreased. This study provides important insight into nutrition-related mechanisms of disc degeneration. Moreover, our model may serve as a powerful tool in the development of new treatments for low back pain.


Journal of Dentistry | 2014

Neural crest-derived dental stem cells—Where we are and where we are going

Vera Mayo; Yoh Sawatari; Chun Yuh Huang; Franklin Garcia-Godoy

OBJECTIVES There are five types of post-natal human dental stem cells that have been identified, isolated and characterized. Here, we review the information available on dental stem cells as well as their potential applications in dentistry, regenerative medicine and the development of other therapeutic approaches. DATA Data pertinent to dental stem cells and their applications, published in peer-reviewed journals from 1982 to 2013 in English were reviewed. SOURCES Sources were retrieved from PubMed databases as well as related references that the electronic search yielded. STUDY SELECTION Manuscripts describing the origin, retrieval, characterization and application of dental stem cells were obtained and reviewed. CONCLUSIONS Dental stem cell populations present properties similar to those of mesenchymal stem cells, such as the ability to self-renew and the potential for multilineage differentiation. While they have greater capacity to give rise to odontogenic cells and regenerate dental pulp and periodontal tissue, they have the capacity to differentiate into all three germ line cells, proving that a population of pluripotent stem cells exists in the dental tissues. CLINICAL SIGNIFICANCE Dental stem cells have the capacity to differentiate into endoderm, mesoderm and ectoderm tissues. Consequently they do not only have applications in dentistry, but also neurodegenerative and ischemic diseases, diabetes research, bone repair, and other applications in the field of tissue regeneration.


Journal of Biomechanics | 2009

TEMPERATURE-DEPENDENT VISCOELASTIC PROPERTIES OF THE HUMAN SUPRASPINATUS TENDON

Chun Yuh Huang; Vincent M. Wang; Evan L. Flatow; Van C. Mow

Temperature effects on the viscoelastic properties of the human supraspinatus tendon were investigated using static stress-relaxation experiments and the quasi-linear viscoelastic (QLV) theory. Twelve supraspinatus tendons were randomly assigned to one of two test groups for tensile testing using the following sequence of temperatures: (1) 37, 27, and 17 degrees C (Group I, n=6), or (2) 42, 32, and 22 degrees C (Group II, n=6). QLV parameter C was found to increase at elevated temperatures, suggesting greater viscous mechanical behavior at higher temperatures. Elastic parameters A and B showed no significant difference among the six temperatures studied, implying that the viscoelastic stress response of the supraspinatus tendon is not sensitive to temperature over shorter testing durations. Using regression analysis, an exponential relationship between parameter C and test temperature was implemented into QLV theory to model temperature-dependent viscoelastic behavior. This modified approach facilitates the theoretical determination of the viscoelastic behavior of tendons at arbitrary temperatures.

Collaboration


Dive into the Chun Yuh Huang's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Evan L. Flatow

Icahn School of Medicine at Mount Sinai

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Vincent M. Wang

Icahn School of Medicine at Mount Sinai

View shared research outputs
Researchain Logo
Decentralizing Knowledge