Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Corinne R. Henak is active.

Publication


Featured researches published by Corinne R. Henak.


Journal of Biomechanics | 2011

Role of the acetabular labrum in load support across the hip joint

Corinne R. Henak; Benjamin J. Ellis; Michael D. Harris; Andrew E. Anderson; Christopher L. Peters; Jeffrey A. Weiss

The relatively high incidence of labral tears among patients presenting with hip pain suggests that the acetabular labrum is often subjected to injurious loading in vivo. However, it is unclear whether the labrum participates in load transfer across the joint during activities of daily living. This study examined the role of the acetabular labrum in load transfer for hips with normal acetabular geometry and acetabular dysplasia using subject-specific finite element analysis. Models were generated from volumetric CT data and analyzed with and without the labrum during activities of daily living. The labrum in the dysplastic model supported 4-11% of the total load transferred across the joint, while the labrum in the normal model supported only 1-2% of the total load. Despite the increased load transferred to the acetabular cartilage in simulations without the labrum, there were minimal differences in cartilage contact stresses. This was because the load supported by the cartilage correlated with the cartilage contact area. A higher percentage of load was transferred to the labrum in the dysplastic model because the femoral head achieved equilibrium near the lateral edge of the acetabulum. The results of this study suggest that the labrum plays a larger role in load transfer and joint stability in hips with acetabular dysplasia than in hips with normal acetabular geometry.


Journal of Orthopaedic Research | 2012

Finite element prediction of cartilage contact stresses in normal human hips

Michael D. Harris; Andrew E. Anderson; Corinne R. Henak; Benjamin J. Ellis; Christopher L. Peters; Jeffrey A. Weiss

Our objectives were to determine cartilage contact stress during walking, stair climbing, and descending stairs in a well‐defined group of normal volunteers and to assess variations in contact stress and area among subjects and across loading scenarios. Ten volunteers without history of hip pain or disease with normal lateral center‐edge angle and acetabular index were selected. Computed tomography imaging with contrast was performed on one hip. Bone and cartilage surfaces were segmented from volumetric image data, and subject‐specific finite element models were constructed and analyzed using a validated protocol. Acetabular contact stress and area were determined for seven activities. Peak stress ranged from 7.52 ± 2.11 MPa for heel‐strike during walking (233% BW) to 8.66 ± 3.01 MPa for heel‐strike during descending stairs (261% BW). Average contact area across all activities was 34% of the surface area of the acetabular cartilage. The distribution of contact stress was highly non‐uniform, and more variability occurred among subjects for a given activity than among activities for a single subject. The magnitude and area of contact stress were consistent between activities, although inter‐activity shifts in contact pattern were found as the direction of loading changed. Relatively small incongruencies between the femoral and acetabular cartilage had a large effect on the contact stresses. These effects tended to persist across all simulated activities. These results demonstrate the diversity and trends in cartilage contact stress in healthy hips during activities of daily living and provide a basis for future comparisons between normal and pathologic hips.


Osteoarthritis and Cartilage | 2014

Patient-specific Analysis of Cartilage and Labrum Mechanics in Human Hips with Acetabular Dysplasia

Corinne R. Henak; Christine L. Abraham; Andrew E. Anderson; Steve A. Maas; Benjamin J. Ellis; Christopher L. Peters; Jeffrey A. Weiss

BACKGROUND Acetabular dysplasia is a major predisposing factor for development of hip osteoarthritis (OA), and may result from alterations to chondrolabral loading. Subject-specific finite element (FE) modeling can be used to evaluate chondrolabral mechanics in the dysplastic hip, thereby providing insight into mechanics that precede OA. OBJECTIVE To evaluate chondrolabral contact mechanics and congruency in dysplastic hips and normal hips using a validated approach to subject-specific FE modeling. METHODS FE models of ten subjects with normal acetabula and ten subjects with dysplasia were constructed using a previously validated protocol. Labrum load support, and labrum and acetabular cartilage contact stress and contact area were compared between groups. Local congruency was determined at the articular surface for two simulated activities. RESULTS The labrum in dysplastic hips supported 2.8-4.0 times more of the load transferred across the joint than in normal hips. Dysplastic hips did not have significantly different congruency in the primary load-bearing regions than normal hips, but were less congruent in some unloaded regions. Normal hips had larger cartilage contact stress than dysplastic hips in the few regions that had significant differences. CONCLUSIONS The labrum in dysplastic hips has a far more significant role in hip mechanics than it does in normal hips. The dysplastic hip is neither less congruent than the normal hip, nor subjected to elevated cartilage contact stresses. This study supports the concept of an outside-in pathogenesis of OA in dysplastic hips and that the labrum in dysplastic hips should be preserved during surgery.


Biomacromolecules | 2013

Synthesis and characterization of a matrix-metalloproteinase responsive silk-elastinlike protein polymer

Joshua A. Gustafson; Robert Price; Jordan Frandsen; Corinne R. Henak; Joseph Cappello; Hamidreza Ghandehari

Silk-elastinlike protein polymers (SELPs) are recombinant polymers consisting of tandem repeats of silk (GAGAGS) and elastin (GVGVP) units. By modification of the length and composition of these repeats, the properties of SELP hydrogels can be controlled for specific applications including nucleic acid and virus delivery and tissue engineering. Here, the structure of SELPs is further modified to include a sequence that is sensitive to matrix-metalloproteinases (MMPs). MMPs are a ubiquitous family of extracellular matrix-modifying enzymes that are commonly associated with numerous vital processes. Increased levels of MMPs are found at high levels locally in many types of solid tumors. By modifying the SELP backbone with MMP-sensitive peptide sequences, a hydrogel that is degradable by MMPs was produced. The MMP-sensitivity of the polymer was examined by incubation with MMP-2 and MMP-9, which yielded complete cleavage of all full-length polymers by 36 hours and 48 hours, respectively, with no observable effect on unmodified SELP. Hydrogel sensitivity was tested by exposure to MMP-2 or MMP-9 for 2 weeks, during which samples were taken to analyze protein loss from the hydrogel and release of 100 nm fluorescent beads. Following the incubation period, hydrogels were tested in mechanical compression to examine the loss of hydrogel stiffness due to degradation. It was found that MMP-2 and MMP-9 caused 63% and 44% increased protein loss and 65% and 95% increased release from MMP-sensitive hydrogels, while the compressive modulus decreased by 41% and 29%. These results suggest the potential of MMP-responsive SELPs for localized delivery of bioactive agents where MMPs are overexpressed.


Journal of Biomechanical Engineering-transactions of The Asme | 2013

Subject-Specific Analysis of Joint Contact Mechanics: Application to the Study of Osteoarthritis and Surgical Planning

Corinne R. Henak; Andrew E. Anderson; Jeffrey A. Weiss

Advances in computational mechanics, constitutive modeling, and techniques for subject-specific modeling have opened the door to patient-specific simulation of the relationships between joint mechanics and osteoarthritis (OA), as well as patient-specific preoperative planning. This article reviews the application of computational biomechanics to the simulation of joint contact mechanics as relevant to the study of OA. This review begins with background regarding OA and the mechanical causes of OA in the context of simulations of joint mechanics. The broad range of technical considerations in creating validated subject-specific whole joint models is discussed. The types of computational models available for the study of joint mechanics are reviewed. The types of constitutive models that are available for articular cartilage are reviewed, with special attention to choosing an appropriate constitutive model for the application at hand. Issues related to model generation are discussed, including acquisition of model geometry from volumetric image data and specific considerations for acquisition of computed tomography and magnetic resonance imaging data. Approaches to model validation are reviewed. The areas of parametric analysis, factorial design, and probabilistic analysis are reviewed in the context of simulations of joint contact mechanics. Following the review of technical considerations, the article details insights that have been obtained from computational models of joint mechanics for normal joints; patient populations; the study of specific aspects of joint mechanics relevant to OA, such as congruency and instability; and preoperative planning. Finally, future directions for research and application are summarized.


Journal of Biomechanical Engineering-transactions of The Asme | 2014

Finite element prediction of transchondral stress and strain in the human hip.

Corinne R. Henak; Gerard A. Ateshian; Jeffrey A. Weiss

Cartilage fissures, surface fibrillation, and delamination represent early signs of hip osteoarthritis (OA). This damage may be caused by elevated first principal (most tensile) strain and maximum shear stress. The objectives of this study were to use a population of validated finite element (FE) models of normal human hips to evaluate the required mesh for converged predictions of cartilage tensile strain and shear stress, to assess the sensitivity to cartilage constitutive assumptions, and to determine the patterns of transchondral stress and strain that occur during activities of daily living. Five specimen-specific FE models were evaluated using three constitutive models for articular cartilage: quasilinear neo-Hookean, nonlinear Veronda Westmann, and tension-compression nonlinear ellipsoidal fiber distribution (EFD). Transchondral predictions of maximum shear stress and first principal strain were determined. Mesh convergence analysis demonstrated that five trilinear elements were adequate through the depth of the cartilage for precise predictions. The EFD model had the stiffest response with increasing strains, predicting the largest peak stresses and smallest peak strains. Conversely, the neo-Hookean model predicted the smallest peak stresses and largest peak strains. Models with neo-Hookean cartilage predicted smaller transchondral gradients of maximum shear stress than those with Veronda Westmann and EFD models. For FE models with EFD cartilage, the anterolateral region of the acetabulum had larger peak maximum shear stress and first principal strain than all other anatomical regions, consistent with observations of cartilage damage in disease. Results demonstrate that tension-compression nonlinearity of a continuous fiber distribution exhibiting strain induced anisotropy incorporates important features that have large effects on predictions of transchondral stress and strain. This population of normal hips provides baseline data for future comparisons to pathomorphologic hips. This approach can be used to evaluate these and other mechanical variables in the human hip and their potential role in the pathogenesis of osteoarthritis (OA).


Journal of Biomechanics | 2015

Toward patient-specific articular contact mechanics

Gerard A. Ateshian; Corinne R. Henak; Jeffrey A. Weiss

The mechanics of contacting cartilage layers is fundamentally important to understanding the development, homeostasis and pathology of diarthrodial joints. Because of the highly nonlinear nature of both the materials and the contact problem itself, numerical methods such as the finite element method are typically incorporated to obtain solutions. Over the course of five decades, we have moved from an initial qualitative understanding of articular cartilage material behavior to the ability to perform complex, three-dimensional contact analysis, including multiphasic material representations. This history includes the development of analytical and computational contact analysis methods that now provide the ability to perform highly nonlinear analyses. Numerical implementations of contact analysis based on the finite element method are rapidly advancing and will soon enable patient-specific analysis of joint contact mechanics using models based on medical image data. In addition to contact stress on the articular surfaces, these techniques can predict variations in strain and strain through the cartilage layers, providing the basis to predict damage and failure. This opens up exciting areas for future research and application to patient-specific diagnosis and treatment planning applied to a variety of pathologies that affect joint function and cartilage homeostasis.


Clinical Radiology | 2014

Computed tomography arthrography with traction in the human hip for three-dimensional reconstruction of cartilage and the acetabular labrum

Corinne R. Henak; Christine L. Abraham; Christopher L. Peters; R.K. Sanders; Jeffrey A. Weiss; Andrew E. Anderson

AIM To develop and demonstrate the efficacy of a computed tomography arthrography (CTA) protocol for the hip that enables accurate three-dimensional reconstructions of cartilage and excellent visualization of the acetabular labrum. MATERIALS AND METHODS Ninety-three subjects were imaged (104 scans); 68 subjects with abnormal anatomy, 11 patients after periacetabular osteotomy surgery, and 25 subjects with normal anatomy. Fifteen to 25 ml of contrast agent diluted with lidocaine was injected using a lateral oblique approach. A Hare traction splint applied traction during CT. The association between traction force and intra-articular joint space was assessed qualitatively under fluoroscopy. Cartilage geometry was reconstructed from the CTA images for 30 subjects; the maximum joint space under traction was measured. RESULTS Using the Hare traction splint, the intra-articular space and boundaries of cartilage could be clearly delineated throughout the joint; the acetabular labrum was also visible. Dysplastic hips required less traction (∼5 kg) than normal and retroverted hips required (>10 kg) to separate the cartilage. An increase in traction force produced a corresponding widening of the intra-articular joint space. Under traction, the maximum width of the intra-articular joint space during CT ranged from 0.98-6.7 mm (2.46 ± 1.16 mm). CONCLUSIONS When applied to subjects with normal and abnormal hip anatomy, the CTA protocol presented yields clear delineation of the cartilage and the acetabular labrum. Use of a Hare traction splint provides a simple, cost-effective method to widen the intra-articular joint space during CT, and provides flexibility to vary the traction as required.


Journal of Biomechanical Engineering-transactions of The Asme | 2017

Multiscale Strain as a Predictor of Impact-Induced Fissuring in Articular Cartilage

Corinne R. Henak; Lena R. Bartell; Itai Cohen; Lawrence J. Bonassar

Mechanical damage is central to both initiation and progression of osteoarthritis (OA). However, specific causal links between mechanics and cartilage damage are incompletely understood, which results in an inability to predict failure. The lack of understanding is primarily due to the difficulty in simultaneously resolving the high rates and small length scales relevant to the problem and in correlating such measurements to the resulting fissures. This study leveraged microscopy and high-speed imaging to resolve mechanics on the previously unexamined time and length scales of interest in cartilage damage, and used those mechanics to develop predictive models. The specific objectives of this study were to: first, quantify bulk and local mechanics during impact-induced fissuring; second, develop predictive models of fissuring based on bulk mechanics and local strain; and third, evaluate the accuracy of these models in predicting fissures. To achieve these three objectives, bovine tibial cartilage was impacted using a custom spring-loaded device mounted on an inverted microscope. The occurrence of fissures was modulated by varying impact energy. For the first objective, during impact, deformation was captured at 10,000 frames per second and bulk and local mechanics were analyzed. For the second objective, data from samples impacted with a 1.2 mm diameter rod were fit to logistic regression functions, creating models of fissure probability based on bulk and local mechanics. Finally, for the third objective, data from samples impacted with a 0.8 mm diameter rod were used to test the accuracy of model predictions. This study provides a direct comparison between bulk and local mechanical thresholds for the prediction of fissures in cartilage samples, and demonstrates that local mechanics provide more accurate predictions of local failure than bulk mechanics provide. Bulk mechanics were accurate predictors of fissure for the entire sample cohort, but poor predictors of fissure for individual samples. Local strain fields were highly heterogeneous and significant differences were determined between fissured and intact samples, indicating the presence of damage thresholds. In particular, first principal strain rate and maximum shear strain were the best predictors of local failure, as determined by concordance statistics. These data provide an important step in establishing causal links between local mechanics and cartilage damage; ultimately, data such as these can be used to link macro- and micro-scale mechanics and thereby predict mechanically mediated disease on a subject-specific basis.


Journal of Biomechanics | 2016

Human talar and femoral cartilage have distinct mechanical properties near the articular surface.

Corinne R. Henak; Keir A. Ross; Edward D. Bonnevie; Lisa A. Fortier; Itai Cohen; John G. Kennedy; Lawrence J. Bonassar

Talar osteochondral lesions (OCL) frequently occur following injury. Surgical interventions such as femoral condyle allogeneic or autogenic osteochondral transplant (AOT) are often used to treat large talar OCL. Although AOT aims to achieve OCL repair by replacing damaged cartilage with mechanically matched cartilage, the spatially inhomogeneous material behavior of the talar dome and femoral donor sites have not been evaluated or compared. The objective of this study was to characterize the depth-dependent shear properties and friction behavior of human talar and donor-site femoral cartilage. To achieve this objective, depth-dependent shear modulus, depth-dependent energy dissipation and coefficient of friction were measured on osteochondral cores from the femur and talus. Differences between anatomical regions were pronounced near the articular surface, where the femur was softer, dissipated more energy and had a lower coefficient of friction than the talus. Conversely, shear modulus near the osteochondral interface was nearly indistinguishable between anatomical regions. Differences in energy dissipation, shear moduli and friction coefficients have implications for graft survival and host cartilage wear. When the biomechanical variation is combined with known biological variation, these data suggest the use of caution in transplanting cartilage from the femur to the talus. Where alternatives exist in the form of talar allograft, donor-recipient mechanical mismatch can be greatly reduced.

Collaboration


Dive into the Corinne R. Henak's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge