Da-Tren Chou
University of Pittsburgh
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Da-Tren Chou.
Acta Biomaterialia | 2015
Amy Chaya; Sayuri Yoshizawa; Kostas Verdelis; Nicole T. Myers; Bernard J. Costello; Da-Tren Chou; Siladitya Pal; Spandan Maiti; Prashant N. Kumta; Charles Sfeir
Each year, millions of Americans suffer bone fractures, often requiring internal fixation. Current devices, like plates and screws, are made with permanent metals or resorbable polymers. Permanent metals provide strength and biocompatibility, but cause long-term complications and may require removal. Resorbable polymers reduce long-term complications, but are unsuitable for many load-bearing applications. To mitigate complications, degradable magnesium (Mg) alloys are being developed for craniofacial and orthopedic applications. Their combination of strength and degradation make them ideal for bone fixation. Previously, we conducted a pilot study comparing Mg and titanium devices with a rabbit ulna fracture model. We observed Mg device degradation, with uninhibited healing. Interestingly, we observed bone formation around degrading Mg, but not titanium, devices. These results highlighted the potential for these fixation devices. To better assess their efficacy, we conducted a more thorough study assessing 99.9% Mg devices in a similar rabbit ulna fracture model. Device degradation, fracture healing, and bone formation were evaluated using microcomputed tomography, histology and biomechanical tests. We observed device degradation throughout, and calculated a corrosion rate of 0.40±0.04mm/year after 8 weeks. In addition, we observed fracture healing by 8 weeks, and maturation after 16 weeks. In accordance with our pilot study, we observed bone formation surrounding Mg devices, with complete overgrowth by 16 weeks. Bend tests revealed no difference in flexural load of healed ulnae with Mg devices compared to intact ulnae. These data suggest that Mg devices provide stabilization to facilitate healing, while degrading and stimulating new bone formation.
Acta Biomaterialia | 2013
Daeho Hong; Partha Saha; Da-Tren Chou; Boeun Lee; Boyce Collins; Zongqing Tan; Zhongyun Dong; Prashant N. Kumta
Mg-4 wt.% Zn-0.5 wt.% Zr (ZK40) alloy was studied as a candidate material for biodegradable metallic implants in terms of its biocorrosion resistance, mechanical properties and cytocompatibility. The corrosion characteristics of ZK40 alloy were assessed by potentiodynamic polarization and immersion testing in DMEM+10% FBS solution. Analysis of the degradation characteristics by potentiodynamic polarization measurements shows the corrosion rates of ZK40 alloy in as-cast and solution treatment (T4) condition were slightly higher than those of pure Mg or as-drawn AZ31. Determination of the corrosion rate by the weight loss technique reveals that the as-cast ZK40 resulted in slower degradation than other alloy specimens after 7 days of immersion but exhibited accelerated degradation after 14 and 21 days, respectively. T4-treated ZK40 exhibited stable degradation rates compared to as-cast ZK40 and close to those of pure Mg and AZ31 during immersion testing for 14 and 21 days. In order to examine the in vitro cytocompatibility of ZK40 alloy, live/dead cell viability assay and indirect MTT assay were performed using a murine osteoblast-like cell line (MC3T3). After 3 days of direct culture of MC3T3 on ZK40 alloys the live/dead assay indicated favorable cell viability and attachment. The degradation product of ZK40 also showed minimal cytotoxicity when assessed in indirect MTT assay. The mechanical properties of the as-cast and T4-treated ZK40 alloy were superior to those of pure Mg and comparable to as-drawn AZ31. Solution treatment did not significantly enhance the cytocompatibility and mechanical properties of ZK40 alloy. Overall, the ZK40 alloy exhibited favorable cytocompatibility, biocorrosion, and mechanical properties rendering it a potential candidate for degradable implant applications.
Acta Biomaterialia | 2013
Da-Tren Chou; Daeho Hong; Partha Saha; Jordan Ferrero; Boeun Lee; Zongqing Tan; Zhongyun Dong; Prashant N. Kumta
This study introduces a class of biodegradable Mg-Y-Ca-Zr alloys novel to biological applications and presents evaluations for orthopedic and craniofacial implant applications. Mg-Y-Ca-Zr alloys were processed using conventional melting and casting techniques. The effects of increasing Y content from 1 to 4 wt.% as well as the effects of T4 solution treatment were assessed. Basic material phase characterization was conducted using X-ray diffraction, optical microscopy and scanning electron microscopy. Compressive and tensile tests allowed for the comparison of mechanical properties of the as-cast and T4-treated Mg-Y-Ca-Zr alloys to pure Mg and as-drawn AZ31. Potentiodynamic polarization tests and mass loss immersion tests were used to evaluate the corrosion behavior of the alloys. In vitro cytocompatibility tests on MC3T3-E1 pre-osteoblast cells were also conducted. Finally, alloy pellets were implanted into murine subcutaneous tissue to observe in vivo corrosion as well as local host response through H&E staining. SEM/EDS analysis showed that secondary phase intermetallics rich in yttrium were observed along the grain boundaries, with the T4 solution treatment diffusing the secondary phases into the matrix while increasing the grain size. The alloys demonstrated marked improvement in mechanical properties over pure Mg. Increasing the Y content contributed to improved corrosion resistance, while solution-treated alloys resulted in lower strength and compressive strain compared to as-cast alloys. The Mg-Y-Ca-Zr alloys demonstrated excellent in vitro cytocompatibility and normal in vivo host response. The mechanical, corrosion and biological evaluations performed in this study demonstrated that Mg-Y-Ca-Zr alloys, especially with the 4 wt.% Y content, would perform well as orthopedic and craniofacial implant biomaterials.
Acta Biomaterialia | 2014
Sarah E. Henderson; Konstantinos Verdelis; Spandan Maiti; Siladitya Pal; William L. Chung; Da-Tren Chou; Prashant N. Kumta; Alejandro J. Almarza
Recently, magnesium (Mg) alloys have received significant attention as potential biomaterials for degradable implants, and this study was directed at evaluating the suitability of Mg for craniofacial bone screws. The objective was to implant screws fabricated from commercially available pure Mg and alloy AZ31 in vivo in a rabbit mandible. First, Mg and AZ31 screws were compared to stainless steel screws in an in vitro pull-out test and determined to have a similar holding strength (∼40N). A finite-element model of the screw was created using the pull-out test data, and this model can be used for future Mg alloy screw design. Then, Mg and AZ31 screws were implanted for 4, 8 and 12weeks, with two controls of an osteotomy site (hole) with no implant and a stainless steel screw implanted for 12weeks. Microcomputed tomography was used to assess bone remodeling and Mg/AZ31 degradation, both visually and qualitatively through volume fraction measurements for all time points. Histological analysis was also completed for the Mg and AZ31 at 12weeks. The results showed that craniofacial bone remodeling occurred around both Mg and AZ31 screws. Pure Mg had a different degradation profile than AZ31; however, bone growth occurred around both screw types. The degradation rate of both Mg and AZ31 screws in the bone marrow space and the muscle were faster than in the cortical bone space at 12weeks. Furthermore, it was shown that by alloying Mg, the degradation profile could be changed. These results indicate the promise of using Mg alloys for craniofacial applications.
Acta Biomaterialia | 2016
Daeho Hong; Da-Tren Chou; Oleg I. Velikokhatnyi; Abhijit Roy; Boeun Lee; Isaac Swink; Ilona Issaev; Howard A. Kuhn; Prashant N. Kumta
3D printing of various biomaterials including titanium and stainless steel has been studied for treating patients with cranio-maxillofacial bone defect. The potential long term complications with use of inert biometals have opened the opportunities for use of biodegradable metals in the clinical arena. The authors previously reported that binder-jet 3D printing technique enhanced the degradation rates of biodegradable Fe-Mn alloy by creating engineered micropores rendering the system attractive as biodegradable implantable devices. In the present study, the authors employed CALPHAD modeling to systematically study and modify the Fe-Mn alloy composition to achieve enhanced degradation rates. Accordingly, Ca and Mg addition to Fe-35wt% Mn solid solution predicted increase in degradation rates. In order to validate the CALPHAD results, Fe - (35-y)wt% Mn - ywt% X (X=Ca, Mg, and y=0, 1, 2) were synthesized by using high energy mechanical alloying (HEMA). Sintered pellets of Fe-Mn-Ca and Fe-Mn-Mg were then subjected to potentiodynamic polarization (PDP) and live/dead cell viability tests. Sintered pellets of Fe-Mn, Fe-Mn-Ca, and Fe-Mn-Mg also exhibited MC3T3 murine pre-osteoblast cells viability in the live/dead assay results. Fe-Mn and Fe-Mn-1Ca were thus accordingly selected for 3D printing and the results further confirmed enhanced degradation of Ca addition to 3D printed constructs validating the theoretical and alloy development studies. Live/dead and MTT cell viability results also confirmed good cytocompatibility of the 3D-printed Fe-Mn and Fe-Mn-1Ca constructs. STATEMENT OF SIGNIFICANCE Bone grafting is widely used for the treatment of cranio-maxillofacial bone injuries. 3D printing of biodegradable Fe alloy is anticipated to be advantageous over current bone grafting techniques. 3D printing offers the fabrication of precise and tailored bone grafts to fit the patient specific bone defect needs. Biodegradable Fe alloy is a good candidate for 3D printing synthetic grafts to regenerate bone tissue without eliciting complications. CALPHAD theoretical models were used to develop new Fe-Mn-Ca/Mg alloys to enhance the degradation rates of traditional Fe-Mn alloys. In vitro experimental results also showed enhanced degradation rates and good cytocompatibility of sintered Fe-Mn-Ca/Mg compacts. 3D printing of Fe-Mn and Fe-Mn-1Ca alloys further demonstrated their feasibility as potentially viable bone grafts for the future.
Acta Biomaterialia | 2017
Daoli Zhao; Tingting Wang; Keaton Nahan; Xuefei Guo; Zhanping Zhang; Zhongyun Dong; Shuna Chen; Da-Tren Chou; Daeho Hong; Prashant N. Kumta; William R. Heineman
The effect of widely different corrosion rates of Mg alloys on four parameters of interest for in vivo characterization was evaluated: (1) the effectiveness of transdermal H2 measurements with an electrochemical sensor for noninvasively monitoring biodegradation compared to the standard techniques of in vivo X-ray imaging and weight loss measurement of explanted samples, (2) the chemical compositions of the corrosion layers of the explanted samples by XPS, (3) the effect on animal organs by histology, and (4) the accumulation of corrosion by-products in multiple organs by ICP-MS. The in vivo biodegradation of three magnesium alloys chosen for their widely varying corrosion rates - ZJ41 (fast), WKX41 (intermediate) and AZ31 (slow) - were evaluated in a subcutaneous implant mouse model. Measuring H2 with an electrochemical H2 sensor is a simple and effective method to monitor the biodegradation process in vivo by sensing H2 transdermally above magnesium alloys implanted subcutaneously in mice. The correlation of H2 levels and biodegradation rate measured by weight loss shows that this non-invasive method is fast, reliable and accurate. Analysis of the insoluble biodegradation products on the explanted alloys by XPS showed all of them to consist primarily of Mg(OH)2, MgO, MgCO3 and Mg3(PO4)2 with ZJ41 also having ZnO. The accumulation of magnesium and zinc were measured in 9 different organs by ICP-MS. Histological and ICP-MS studies reveal that there is no significant accumulation of magnesium in these organs for all three alloys; however, zinc accumulation in intestine, kidney and lung for the faster biodegrading alloy ZJ41 was observed. Although zinc accumulates in these three organs, no toxicity response was observed in the histological study. ICP-MS also shows higher levels of magnesium and zinc in the skull than in the other organs. STATEMENT OF SIGNIFICANCE Biodegradable devices based on magnesium and its alloys are promising because they gradually dissolve and thereby avoid the need for subsequent removal by surgery if complications arise. In vivo biodegradation rate is one of the crucial parameters for the development of these alloys. Promising alloys are first evaluated in vivo by being implanted subcutaneously in mice for 1month. Here, we evaluated several magnesium alloys with widely varying corrosion rates in vivo using multiple characterization techniques. Since the alloys biodegrade by reacting with water forming H2 gas, we used a recently demonstrated, simple, fast and noninvasive method to monitor the biodegradation process by just pressing the tip of a H2 sensor against the skin above the implant. The analysis of 9 organs (intestine, kidney, spleen, lung, heart, liver, skin, brain and skull) for accumulation of Mg and Zn revealed no significant accumulation of magnesium in these organs. Zinc accumulation in intestine, kidney and lung was observed for the faster corroding implant ZJ41. The surfaces of explanted alloys were analyzed to determine the composition of the insoluble biodegradation products. The results suggest that these tested alloys are potential candidates for biodegradable implant applications.
Acta Biomaterialia | 2016
Daoli Zhao; Tingting Wang; William Hoagland; David Benson; Zhongyun Dong; Shuna Chen; Da-Tren Chou; Daeho Hong; Jingyao Wu; Prashant N. Kumta; William R. Heineman
A visual sensor for H2 was used to transdermally monitor H2 that originated from biodegrading magnesium (Mg) alloys implanted subcutaneously in mice. The visual sensor consisted of a thin film of H2-sensitive material (MoO3 and Pd catalyst) coated on a flexible plastic sheet that was pressed against the mouse skin directly above the implant. Although the H2 levels permeating through the skin during the degradation process were very low, the sensor changed color to give a three dimensional (3D) visualization of H2 permeation. The correlation between the visual sensor response and measurements made with an electrochemical H2 microsensor on several magnesium alloys demonstrates that the visual sensor has the capability to monitor in real-time the dissolution rate of implants in vivo. This detection method is noninvasive, easy to implement, effective and potentially low cost compared to electrochemical detection. STATEMENT OF SIGNIFICANCE Biodegradable Mg implants offer advantages over permanent implants such as stainless steel that are used for broken bone repair. Mg alloys gradually dissolve, avoiding the need for removal by a later surgery if complications arise. Here we report a visual H2 sensor that can be used in the research laboratory to monitor the corrosion process in vivo during animal testing of different Mg alloys. The sensor consists of a plastic sheet with a thin coating that changes color in the presence of H2 gas. The sensor is easily used by taping it on the skin over the Mg implant. The color change gives a map of the H2 level permeating from the degrading Mg through the skin above it. This low cost, simple method of monitoring the dissolution of biodegradable implants would greatly facilitate the development of the biodegradable materials, especially in animal studies where in vivo biodegradation is tested.
Journal of Biomedical Materials Research Part A | 2014
Sarah A. Luffy; Da-Tren Chou; Jenora Waterman; Peter D. Wearden; Prashant N. Kumta; Thomas W. Gilbert
Tracheomalacia is a relatively rare problem, but can be challenging to treat, particularly in pediatric patients. Due to the presence of mechanically deficient cartilage, the trachea is unable to resist collapse under physiologic pressures of respiration, which can lead to acute death if left untreated. However, if treated, the outcome for patients with congenital tracheomalacia is quite good because the cartilage tends to spontaneously mature over a period of 12 to 18 months. The present study investigated the potential for the use of degradable magnesium-3% yttrium alloy (W3) to serve as an extraluminal tracheal stent in a canine model. The host response to the scaffold included the formation of a thin, vascularized capsule consisting of collagenous tissue and primarily mononuclear cells. The adjacent cartilage structure was not adversely affected as observed by bronchoscopic, gross, histologic, and mechanical analysis. The W3 stents showed reproducible spatial and temporal fracture patterns, but otherwise tended to corrode quite slowly, with a mix of Ca and P rich corrosion product formed on the surface and observed focal regions of pitting. The study showed that the approach to use degradable magnesium alloys as an extraluminal tracheal stent is promising, although further development of the alloys is required to improve the resistance to stress corrosion cracking and improve the ductility.
ACS Biomaterials Science & Engineering | 2017
Gary Z. Yu; Da-Tren Chou; Daeho Hong; Abhijit Roy; Prashant N. Kumta
Additive manufacturing presents opportunities to treat bone defects using biomimetic tissue scaffolds. Past investigations have explored modulating scaffold mechanical properties through varying materials and geometric motifs. Herein, we applied the rotated plywood structure of bone tissue to a 3D printed scaffold with the goal of improving mechanical performance compared to an orthogonal mesh design commonly used in tissue scaffold applications. The scaffolds were subjected to uniaxial compression followed by scanning electron microscopy and microcomputer tomography. The uniaxial compression test was characterized through elastic modulus (mean 1.32 GPa biomimetic, 0.196 GPa orthogonal, p < 0.001), ultimate compressive strength (mean 16.546 MPa biomimetic, 6.309 MPa orthogonal design, p < 0.001), and ultimate compressive strain values (4.867% biomimetic, 9.000% orthogonal, p < 0.005). Correlation of microfracture imaging to bulk scaffold mode of failure suggest that utilizing the biomimetic plywood design not only improved mechanical performance, but also reduced asymmetrtic buckling, plastic deformation, and fracture propagation similar to bone tissue.
ASME 2013 Conference on Frontiers in Medical Devices: Applications of Computer Modeling and Simulation | 2013
Siladitya Pal; Amy Chaya; Sayuri Yoshizawa; Da-Tren Chou; Daeho Hong; Spandan Maiti; Prashant N. Kumta; Charles Sfeir
Each year, there are over six million bone fractures in the U.S., over 30% of which require internal fixation devices to stabilize bone fragments during healing [1–2]. Currently, the gold standard materials for these devices are non-degradable titanium alloys. Unfortunately, these devices cause numerous complications and often require a secondary invasive removal surgery [3–4]. To circumvent these issues, resorbable polymeric devices have been developed, but their mechanical limitations render them inadequate for most load bearing applications [5–7].Copyright