Daniel R. Turner
Wayne State University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Daniel R. Turner.
Catheterization and Cardiovascular Interventions | 2007
Thomas J. Forbes; Swati Garekar; Zahid Amin; Evan M. Zahn; David Nykanen; Phillip Moore; Shakeel A. Qureshi; John P. Cheatham; Makram R. Ebeid; Ziyad M. Hijazi; Satinder Sandhu; Donald J. Hagler; Horst Sievert; Thomas E. Fagan; Jeremy M. Ringewald; Wei Du; Liwen Tang; David F. Wax; John F. Rhodes; Troy A. Johnston; Thomas K. Jones; Daniel R. Turner; Carlos A. C. Pedra; William E. Hellenbrand
Background: We report a multi‐institutional experience with intravascular stenting (IS) for treatment of coarctation of the aorta. Methods and Results: Data was collected retrospectively by review of medical records from 17 institutions. The data was broken down to prior to 2002 and after 2002 for further analysis. A total of 565 procedures were performed with a median age of 15 years (mean = 18.1 years). Successful reduction in the post stent gradient (<20 mm Hg) or increase in post stent coarctation to descending aorta (DAo) ratio of >0.8 was achieved in 97.9% of procedures. There was significant improvement (P < 0.01) in pre versus post stent coarctation dimensions (7.4 mm ± 3.0 mm vs. 14.3 ± 3.2mm), systolic gradient (31.6 mm Hg ± 16.0 mm Hg vs. 2.7 mm Hg ± 4.2 mm Hg) and ratio of the coarctation segment to the DAo (0.43 ± 0.17 vs. 0.85 ± 0.15). Acute complications were encountered in 81/565 (14.3%) procedures. There were two procedure related deaths. Aortic wall complications included: aneurysm formation (n = 6), intimal tears (n = 8), and dissections (n = 9). The risk of aortic dissection increased significantly in patients over the age of 40 years. Technical complications included stent migration (n = 28), and balloon rupture (n = 13). Peripheral vascular complications included cerebral vascular accidents (CVA) (n = 4), peripheral emboli (n = 1), and significant access arterial injury (n = 13). Older age was significantly associated with occurrence of CVAs. A significant decrease in the technical complication rate from 16.3% to 6.1% (P < 0.001) was observed in procedures performed after January 2002. Conclusions: Stent placement for coarctation of aorta is an effective treatment option, though it remains a technically challenging procedure. Technical and aortic complications have decreased over the past 3 years due to, in part, improvement in balloon and stent design. Improvement in our ability to assess aortic wall compliance is essential prior to placement of ISs in older patients with coarctation of the aorta.
Journal of the American College of Cardiology | 2011
Thomas J. Forbes; Dennis W. Kim; Wei Du; Daniel R. Turner; Ralf Holzer; Zahid Amin; Ziyad M. Hijazi; Abdolrahim Ghasemi; Jonathan J. Rome; David Nykanen; Evan M. Zahn; Collin G. Cowley; Mark Hoyer; David Waight; Daniel H. Gruenstein; Alex Javois; Susan Foerster; Jacqueline Kreutzer; Nancy Sullivan; Asra Khan; Carl Y. Owada; Donald J. Hagler; Scott Lim; Joshua Canter; Thomas M. Zellers
OBJECTIVES The purpose of this study was to compare the safety and efficacy of surgical, stent, and balloon angioplasty (BA) treatment of native coarctation acutely and at follow-up. BACKGROUND Controversy surrounds the optimal treatment for native coarctation of the aorta. This is the first multicenter study evaluating acute and follow-up outcomes of these 3 treatment options in children weighing >10 kg. METHODS This is a multicenter observational study. Baseline, acute, short-term (3 to 18 months), and intermediate (>18 months) follow-up hemodynamic, imaging data, and complications were recorded. RESULTS Between June 2002 and July 2009, 350 patients from 36 institutions were enrolled: 217 underwent stent, 61 underwent BA, and 72 underwent surgery. All 3 arms showed significant improvement acutely and at follow-up in resting systolic blood pressure and upper to lower extremity systolic blood pressure gradient (ULG). Stent was superior to BA in achieving lower ULG acutely. Surgery and stent were superior to BA at short-term follow-up in achieving lower ULG. Stent patients had shorter hospitalization than surgical patients (2.4 vs. 6.4 days; p < 0.001) and fewer complications than surgical and BA patients (2.3%, 8.1%, and 9.8%; p < 0.001). The BA patients were more likely to encounter aortic wall injury, both acutely and at follow-up (p < 0.001). CONCLUSIONS Stent patients had significantly lower acute complications compared with surgery patients or BA patients, although they were more likely to require a planned reintervention. At short-term and intermediate follow-up, stent and surgical patients achieved superior hemodynamic and integrated aortic arch imaging outcomes compared with BA patients. Because of the nonrandomized nature of this study, these results should be interpreted with caution.
Catheterization and Cardiovascular Interventions | 2007
Thomas J. Forbes; Phillip Moore; Carlos A. C. Pedra; Evan M. Zahn; David Nykanen; Zahid Amin; Swati Garekar; David F. Teitel; Shakeel A. Qureshi; John P. Cheatham; Makram R. Ebeid; Ziyad M. Hijazi; Satinder Sandhu; Donald J. Hagler; Horst Sievert; Thomas E. Fagan; Jeremy Ringwald; Wei Du; Liwen Tang; David F. Wax; John F. Rhodes; Troy A. Johnston; Thomas K. Jones; Daniel R. Turner; Robert H. Pass; Alejandro Torres; William E. Hellenbrand
Background: We report a multiinstitutional study on intermediate‐term outcome of intravascular stenting for treatment of coarctation of the aorta using integrated arch imaging (IAI) techniques. Methods and Results: Medical records of 578 patients from 17 institutions were reviewed. A total of 588 procedures were performed between May 1989 and Aug 2005. About 27% (160/588) procedures were followed up by further IAI of their aorta (MRI/CT/repeat cardiac catheterization) after initial stent procedures. Abnormal imaging studies included: the presence of dissection or aneurysm formation, stent fracture, or the presence of reobstruction within the stent (instent restenosis or significant intimal build‐up within the stent). Forty‐one abnormal imaging studies were reported in the intermediate follow‐up at median 12 months (0.5–92 months). Smaller postintervention of the aorta (CoA) diameter and an increased persistent systolic pressure gradient were associated with encountering abnormal follow‐up imaging studies. Aortic wall abnormalities included dissections (n = 5) and aneurysm (n = 13). The risk of encountering aortic wall abnormalities increased with larger percent increase in CoA diameter poststent implant, increasing balloon/coarc ratio, and performing prestent angioplasty. Stent restenosis was observed in 5/6 parts encountering stent fracture and neointimal buildup (n = 16). Small CoA diameter poststent implant and increased poststent residual pressure gradient increased the likelihood of encountering instent restenosis at intermediate follow‐up. Conclusions: Abnormalities were observed at intermediate follow‐up following IS placement for treatment of native and recurrent coarctation of the aorta. Not exceeding a balloon:coarctation ratio of 3.5 and avoidance of prestent angioplasty decreased the likelihood of encountering an abnormal follow‐up imaging study in patients undergoing intravascular stent placement for the treatment of coarctation of the aorta. We recommend IAI for all patients undergoing IS placement for treatment of CoA.
Circulation | 2003
Titus Kuehne; Maythem Saeed; Kelly Gleason; Daniel R. Turner; David F. Teitel; Charles B. Higgins; Phillip Moore
Background—This study was conducted to determine the effects of chronic pulmonary insufficiency (PI) on right (RV) and left (LV) ventricular function in young growing swine. Methods and Results—Six PI and 5 control animals were studied. PI was induced by transcatheter placement of stents across the pulmonary valve. Indices of systolic function (ejection fraction, cardiac output, and cardiac functional reserve), diastolic function (compliance), and myocardial contractility (the slope of the relationship of end-systolic pressure versus end-systolic volume [Emax] and the slope of the dP/dtmax–end-diastolic volume relationship [MdP/dt]) were assessed within 2 days of intervention and 3 months later. MRI was used to quantify PI and ventricular volumes. Conductance catheter techniques were used to obtain indices of contractility and diastolic compliance from pressure-volume relations at rest and under dobutamine infusion. In the PI group, pulmonary regurgitant fraction was 49.2±5.9% at 3-month follow-up. RV cardiac functional reserve was limited, diastolic function was preserved, and myocardial contractility was altered (Emax=2.6±0.3 mm Hg/mL for the PI group versus 3.5±0.4 mm Hg/mL for control; P <0.01). LV cardiac functional reserve was limited, ventricular compliance decreased, and myocardial contractility was preserved. Conclusions—In the young developing heart, chronic PI alters biventricular systolic function, RV myocardial contractility, and LV diastolic performance.
Catheterization and Cardiovascular Interventions | 2010
Abdolrahim Ghasemi; Swati Pandya; Surendranath R. Veeram Reddy; Daniel R. Turner; Wei Du; Mohamad Ali Navabi; Mohammad Reza Mirzaaghayan; Abdolrazagh Kiani; Katherine Sloan; Thomas J. Forbes
Background: Over the past three decades, transcatheter occlusion of patent ductus arteriosus (PDA) has evolved to be the procedure of choice. Gianturco and Flipper coils are the most commonly used coils in the United States for closure of small and moderate size PDAs. For larger PDAs, interventionalists in the United States commonly use the Amplatzer Duct Occluder (ADO) and those in Europe use the ADO or the Nit‐Occlud Coils (NOC). A comparison between Gianturco coils, Flipper coils, ADO, and NOC has never been made. Objective: To compare the success and complication rate associated with the four different devices used for transcatheter closure of PDA. Success was defined as complete closure of PDA with absence of a residual shunt (R.S.) at six months follow‐up. Methods: Two institutions collaborated in combining their data to evaluate the results of transcatheter closure of PDA. Results: Totally, 546 patients underwent successful PDA occlusion at both institutions. Gianturco and Flipper coils were used in 120 (22%) and 119 (22%) patients respectively. A total of 152 (28%) patients received ADO and 155 (28%) patients received NOC. Immediate R.S. were noted in 226 (41.4%) patients in the entire study group with the NOC group having the highest percentage of R.S. (80/155, 51.6%, P = 0.004). Of the 484 patients with follow‐up echocardiograms at 6 months, 35 (7.2%) patients had persistent R.S. The NOC (3/143, 2.1%) and ADO (5/150, 3.3%) groups had the least R.S. at six months follow‐up. Conclusion: Per our definition of success, the Nit‐Occlud coils and the Amplatzer duct‐occluder devices had significantly higher success rate for PDA occlusion versus the coils.
Catheterization and Cardiovascular Interventions | 2013
Srinath T. Gowda; Thomas J. Forbes; Harinder R. Singh; Julie Kovach; Lourdes R. Prieto; Larry A. Latson; Daniel R. Turner
To evaluate postdiscovery outcome of coronary artery fistulae (CAF). CAF treatment sequelae and risk factors for coronary thrombosis have not been adequately evaluated.
Catheterization and Cardiovascular Interventions | 2004
Thomas J. Forbes; Ashraf Harahsheh; Edwin Rodriguez-Cruz; William R. Morrow; Ronald Thomas; Daniel R. Turner; Julie A. Vincent
Transcatheter occlusion of patent ductus arteriosus (PDA) using Gianturco coils (GCs) has been performed for the past decade. However, little has been written regarding anatomical and hemodynamic predictors for successful occlusion of the PDA in infants. This report is to evaluate the outcome of transcatheter occlusion of PDA in symptomatic infants less than 8 kg and to assess predictors of successful occlusion. Retrospective review of catheterization charts and cineangiograms of 42 symptomatic infants who underwent cardiac catheterization for attempted transcatheter occlusion of their PDA was conducted. The hemodynamic and angiographic data evaluated included the length/diameter (L/D) ratio, defined as the length divided by the narrowest diameter of the ductus arteriosus, and preocclusion pulmonary artery pressures. Thirty‐one out of 42 patients (74%) had successful occlusion. Twenty‐nine out of 42 infants had an L/D ratio > 3. Of these, 26 (90%) had successful occlusion of their PDA. Thirteen out of 42 patients had an L/D ratio ≤ 3. Of these, 8 (62%) had unsuccessful occlusion. Complications encountered were transient loss of femoral arterial pulse (n = 6), coil embolization (n = 5), hemolysis (n = 2), and mild left pulmonary artery obstruction (n = 2). No permanent loss of femoral arterial pulse was noted. These complications resulted in no mortality and minimal morbidity. The L/D ratio was the strongest predictor of successful outcome, with an L/D ratio greater than 3.0 being more amenable to transcatheter occlusion (odds ratio of 4.6). Other predictors for success included lower preocclusion systolic, diastolic, and mean pulmonary artery pressure and smaller ductal diameter. Our conclusion was that infants less than 8 kg with an L/D ratio > 3.0 can safely and successfully undergo transcatheter occlusion of their PDA using transcatheter coils. Catheter Cardiovasc Interv 2004;61:117–122.
Congenital Heart Disease | 2007
Clifford L. Cua; Mark Galantowicz; Daniel R. Turner; Thomas J. Forbes; Sharon L. Hill; Timothy M. Hoffman; John P. Cheatham
Despite improvements in survival of patients with hypoplastic left heart syndrome (HLHS) with various palliative procedures, certain risk factors, such as weight less than 2.5 kg, continue to predict increased mortality. We report the palliation of a patient with HLHS weighing 1.4 kg via a hybrid procedure consisting of banding of the pulmonary arteries bilaterally, stenting the ductus arteriosus, and balloon atrial septostomy. We propose that this may be another alternative for palliation in this high-risk patient group.
Catheterization and Cardiovascular Interventions | 2005
Swati Garekar; Melissa M. Paules; Surendranath R. Veeram Reddy; Daniel R. Turner; Sanjeev Sanjeev; Joshua Wynne; Michael L. Epstein; Peter P. Karpawich; Robert D. Ross; Thomas J. Forbes
Objective: To determine the complication rate during the catheterization in adults with congenital heart disease (CHD) in a pediatric catheterization laboratory (PCL). Background: An increasing number of patients with CHD are surviving into adulthood, with diagnostic and interventional cardiac catheterization being essential for the management of their disease. The complication rate during the catheterization of adults with CHD has not been reported. Methods: A retrospective chart review was performed on all adult patients (>18 years) with CHD who underwent diagnostic or interventional catheterization in our PCL within the past 8.5 years. Results: A total of 576 procedures were performed on 436 adult patients (median age 26 years). Complex heart disease was present in 387/576 (67%) procedures. An isolated atrial septal defect or patent foramen ovale was present in 115/576 (20%) procedures, and 51/576 (9%) procedures were performed on patients with structurally normal hearts with arrhythmias. Interventional catheterization was performed in 378/576 (66%) procedures. There were complications during 61/576 (10.6%) procedures; 19 were considered major and 42 minor. Major complications were death (1), ventricular fibrillation (1), hypotension requiring inotropes (7), atrial flutter (3), retroperitoneal hematoma, pneumothorax, hemothorax, aortic dissection, renal failure, myocardial ischemia and stent malposition (1 each). The most common minor complications were vascular entry site hematomas and hypotension not requiring inotropes. Procedures performed on patients ≥ 45 years of age had a 19% occurrence of complications overall compared with 9% occurrence rate in patients of age < 45 years (P < 0.01). Conclusions: The complication rate during the catheterization of adults with CHD in a PCL is similar to the complication rate of children with CHD undergoing cardiac catheterization. The older subset of patients are more likely to encounter complications overall. The encountered complications could be handled effectively in the PCL. With screening in place, it is safe to perform cardiac catheterization on most adults with CHD in a PCL.
Catheterization and Cardiovascular Interventions | 2003
Kavitha Chintala; Daniel R. Turner; Stephanie Leaman; Edwin Rodriguez-Cruz; Joshua Wynne; Adam Greenbaum; Thomas J. Forbes
CardioSEAL device closure of patent foramen ovale (PFO) has been advocated for the treatment of patients with cryptogenic stroke. Using the standard delivery technique, partial deployment of the CardioSEAL device can occur, especially in patients with a thick septum secundum and/or long PFO tunnel. We hypothesized that using a left atrial‐to‐right atrial balloon pull‐through to make the septum primum incompetent would result in improved final device position regardless of septal thickness or tunnel length. Catheterization reports, cineangiograms, and transesophageal echocardiograms of 51 patients who underwent CardioSEAL device closure of PFO between March 2000 and August 2002 were retrospectively reviewed. Group 1 (n = 21) included patients with CardioSEAL placement using the standard technique and group 2 (n = 30) included patients with CardioSEAL placement using the balloon pull‐through technique. There were no differences between the groups in terms of age (43.6 vs. 45.3 years; P = NS), weight (83.3 vs. 89.9 kg; P = NS), septum secundum thickness (6.4 vs. 7.0 mm; P = NS), PFO tunnel length (15.5 vs. 13.1 mm; P = NS), or device size. In group 1, 4/21 (19%) had partial deployment of the CardioSEAL device, while in group 2, no partial CardioSEAL deployment (0/30) was observed. No complications were associated with the balloon pull‐through technique. We conclude that the left atrial‐to‐right atrial balloon pull‐through technique is safe and may allow for better final position of the CardioSEAL device during PFO closure. Catheter Cardiovasc Interv 2003;60:101–106.