Journal of Prosthodontics | 2009

Influence of investment, disinfection, and storage on the microhardness of ocular resins.

Marcelo Coelho Goiato; Daniela Micheline dos Santos; Humberto Gennari-Filho; Adriana Cristina Zavanelli; Stefan Fiuza de Carvalho Dekon; Daniela Nardi Mancuso

PURPOSE The longevity of an ocular prosthesis is directly related to the resistance to erosion of its material. The purpose of this study was to evaluate the effects of chemical disinfection and the method of investment on the microhardness of ocular prosthesis acrylic resin. MATERIALS AND METHODS Thirty-two test specimen investments were obtained in two silicones. A segment was cut in each test specimen, and each specimen was fixed in an acrylic disk. The specimens were then polished and submitted to the first microhardness test before immersion in distilled water and incubation for 2 months. During this 2-month period, the specimens were immersed in a water bath at 37 degrees C and were disinfected daily; half were disinfected with neutral soap and the other half were disinfected with 4% chlorhexidine gluconate. After the storage phase and disinfection, a second microhardness test was performed. The surface microhardness values for the acrylic resins were submitted to ANOVA, followed by the Tukey test. RESULTS The disinfection and the period of storage did not statistically influence the surface microhardness of the acrylic resin, independent of the method of investment of the specimens (Zetalabor or Vipi Sil). The investment of specimens with Zetalabor silicone presented a greater surface hardness, independent of the type of disinfection and the period of storage. CONCLUSIONS Based on these results, we suggest that the microhardness of the resin evaluated was not influenced by the method of disinfection or the time of storage used and was affected only by the investment material.


Indian Journal of Dental Research | 2009

Visual evaluation of color stability after accelerated aging of pigmented and nonpigmented silicones to be used in facial prostheses.

Daniela Nardi Mancuso; Marcelo Coelho Goiato; Stefan Fiuza de Carvalho Dekon; Humberto Gennari-Filho

OBJECTIVES The objective of this study was to evaluate by a visual method of comparison the color stability of nonpigmented and pigmented facial silicones after accelerated aging. MATERIALS AND METHODS Two kinds of silicones were used in this study; one specifically formulated for facial prostheses and the other an acetic silicone for industrial use. Twenty-four trial bodies were made for each silicone. These were divided into colorless and intrinsically pigmented groups: ceramic, make-up, and iron oxide. The groups were submitted to accelerated aging for nonmetallic materials. An initial reading and subsequent readings were made at 163, 351, 692, and 1000 hours using a visual method of comparison. The values were annotated in a spreadsheet by two observers, according to scores elaborated for this study. RESULTS All groups presented color stability in the visual method. According to the results obtained and analyzed in this study, we can conclude that both silicones, Silastic 732 RTV and Silastic MDX 4-4210, behaved similarly, they can therefore be indicated for use in maxillofacial prosthesis. The time factor of aging influenced negatively, independently of the pigmentation, or lack of it, and of silicones and no group had visually noticeable alterations in any of the accelerated aging time, independently of the addition or not of pigments.


Brazilian Oral Research | 2009

Color stability after accelerated aging of two silicones, pigmented or not, for use in facial prostheses

Daniela Nardi Mancuso; Marcelo Coelho Goiato; Daniela Micheline dos Santos

One of the greatest challenges faced by buccomaxillofacial prosthetists is to reproduce the patients exact skin color and provide adequate esthetics. To reach this objective, professionals must use materials with easy characterization and that maintain color over long periods of time. The objective of this study was, thus, to evaluate the color stability of two types of silicones, Silastic 732 and Silastic MDX4-4210. Twenty-four test specimens were made from each type of silicone and were divided into a colorless group and groups intrinsically pigmented with ceramics, cosmetics or iron oxide. The specimens were submitted to an accelerated system of aging for non-metallic materials. Readings were carried out initially and after periods corresponding to 163, 351, 692 and 1,000 hours of aging, using a reflection spectrophotometer analysis, and color alterations were calculated by the CIE L*a*b* system. The data were submitted to variance analysis and Tukeys test at a 5% level of probability. The results demonstrated that, irrespective of the period of time analyzed, all the materials underwent some type of chromatic alteration (DeltaE > 0). The test specimens made with Silastic 732 and MDX4-4210, without pigmentation, presented the lowest color alteration values after 1,000 hours of aging. Of the pigments, ceramic presented the lowest color alteration values and cosmetic powder presented the highest values. Thus, it may be concluded that the materials without the incorporation of pigments presented similar color alteration values, and did not differ statistically. The cosmetic powder used in this study was the pigment that most altered the color of the test specimens.


Gerodontology | 2012

Effect of thermocycling on hardness, absorption, solubility and colour change of soft liners

Daniela Nardi Mancuso; Marcelo Coelho Goiato; Bruna Carolina Rossatti Zuccolotti; Amália Moreno; Daniela Micheline dos Santos; Aldiéris Alves Pesqueira

OBJECTIVE The effect of artificial ageing on the hardness, absorption, solubility, and colour of soft denture liners was investigated. MATERIALS AND METHODS Liner materials based on acrylic resin (Trusoft) or silicone (Dentusil, Ufi Gel P, and Ufi Gel SC) were tested before and after 2000 thermal cycles. A total of 20 specimens of each material were tested. Half of the specimens were used for hardness and colour evaluation, and the remainder for absorption and solubility tests. The hardness evaluation was carried out using a Shore A durometer, while absorption and solubility tests were performed by storing samples in a desiccator and weighing daily until reaching constant mass (W1). After thermocycling, the samples were again weighed (W2) and dried (W3). Colour was measured using a spectrophotometer. Statistical analysis was performed using GraphPad InStat at the p < 0.05 level. RESULTS Thermocycling significantly affected the hardness of the specimens. The Trusoft material exhibited the highest absorption (1.48 ± 0.48), solubility (1.26 ± 0.28), and colour change (3.92 ± 0.33), significantly different from the other materials. There were no significant differences among the silicones in terms of absorption, solubility, and colour change, except for the colour of Dentusil, which changed (0.83 ± 0.11). CONCLUSION It can be concluded that silicone liners performed significantly better compared to acrylic resin.


web science | 2010

Care and Cleaning of Maxillofacial Prostheses

Marcelo Coelho Goiato; Bruna Carolina Rossatti Zucolotti; Daniela Nardi Mancuso; Daniela Micheline dos Santos; Eduardo Piza Pellizzer; Fellippo Ramos Verri

Both the cleaning and care of the prosthesis are fundamental for maintaining its quality. Therefore, the aim of this study was to show the methods of cleaning and care the patient needs to take as regards the prosthesis and adjacent tissue, starting with correct instruction and training by the professional. It has been verified that among the materials for fabricating maxillofacial prostheses, silicone was considered the major retainer of microorganisms on its surface. Therefore, for cleaning prostheses, the use of water and neutral soap, as well as chlorhexidine, is recommended. As regards care of the adjacent tissues, it is recommended to remove the prosthesis before going to sleep, in addition to washing the prosthesis receptor tissues with water and neutral soap or with a mixture of hydrogen peroxide and water. Whereas for the mucosal surfaces of the ophthalmic cavity, cleaning with filtered and boiled water or physiological solution at least 3 times a day is recommended.


Primary dental care : journal of the Faculty of General Dental Practitioners | 2009

Evaluation of hardness and colour change of soft liners after accelerated ageing.

Daniela Nardi Mancuso; Marcelo Coelho Goiato; Bruna Carolina Rossatti Zuccolotti; Amália Moreno; Daniela Micheline dos Santos

Introduction Soft liners have been developed to offer comfort to denture wearers. However, this comfort is compromised when there is a change in the properties of the material, causing colour change, solubility, absorption and hardening. These characteristics can compromise the longevity of soft liners. Aim The aim of this in vitro study was to investigate the effect of ageing on both the hardness and colour change of two soft liners following accelerated ageing. Methods Two denture liners, one resin based (Trusoft, Bosworth, Illinois, USA) and one silicone based (Ufi Gel P, Voco GMBH, Cuxhaven, Germany), were tested in this study for both hardness (using the Shore A scale) and colour change (using the CIE L*a*b* colour scale), initially and after 1008 hours (6 weeks) of accelerated ageing. Statistical analysis was performed using the unpaired t-test with the Welch correction. Results These indicated that both materials increased in hardness and underwent colour change after accelerated ageing. The initial hardness of Trusoft was far lower than that of Ufi Gel P (18.2 Shore A units vs 34.8 Shore A units). However, for Trusoft the changes for both hardness (from 18.2 to 52.1 Shore A units) and colour change (16.85 on the CIE L*a*b* colour scale) were greater than those for Ufi Gel P, for which hardness changed from 34.8 to 36.5 Shore A units and the colour change was 5.19 on the CIE L*a*b* colour scale. Conclusions Ufi Gel P underwent less hardness and colour change after accelerated ageing than Trusoft. On the other hand, the use of Trusoft may be preferable in cases where initial softness is a major consideration, such as when relining an immediate denture after implant surgery.


Jcpsp-journal of The College of Physicians and Surgeons Pakistan | 2009

Finger prosthesis: the art of reconstruction.

Marcelo Coelho Goiato; Daniela Nardi Mancuso; Pedro Paulo Marques Ferreira; Daniela Micheline dos Santos

Hand deformities affect aesthetics function of hand severely compromised and also cause psychological disturbances. This report describes the fabrication of a silicone finger prosthesis for a patient after an accident at work. The finger prosthesis was retained by a vacuum effect on the stump. The silicone material Silastic-MDX 44210 was used to provide function and aesthetics. The finger prosthesis offered psychological, functional and rehabilitative advantages for the patient. Restoring the natural appearance with the prosthesis eliminated the trauma generated by the dysfunction and represented an efficient psychological therapy.


Brazilian Oral Research | 2018

Tissue reaction to Aroeira (Myracrodruon urundeuva) extracts associated with microorganisms: an in vivo study

Carlos Roberto Emerenciano Bueno; Diego Valentim; Elerson Gaetti-Jardim Júnior; Daniela Nardi Mancuso; Gustavo Sivieri-Araujo; Rogério de Castilho Jacinto; Luciano Tavares Angelo Cintra; Eloi Dezan-Júnior

Based on aroeiras (Myracrodruon urundeuva) antimicrobial activity and a future trend to compose intracanal medication, the aim of this study was to assess in vivo inflamatory tissue response to the extracts by edemogenic and histological analysis containing inactivated facultative and anaerobic microorganisms. For edema quantification, eighteen animals were divided into three groups (n = 3, periods: 3 and 6 hours) and 0.2 mL of 1% Evans blue per 100 g of body weight was injected into the penile vein under general anesthesia. After 30 min the animals received a subcutaneous injection in the dorsal region of aqueous or ethanolic extract of aroeira or saline (control) containing inactivated bacteria. Samples were collected, immersed in formamide for 72h, and evaluated by spectrophotometry (630 m). For histological analysis, polyethylene tubes with the extracts were implanted in the dorsal of 30 male rats. Analysis of the fibrous capsule and inflammatory infiltrate were performed after 7 and 30 days. The aqueous extract group induced less edema in both postoperative periods compared to the other groups, but the differences were not significant (p > 0.05). Tissue repair was significantly better after 30 days than after 7 days (p < 0.01). The aqueous solution showed less inflammatory response than the ethanolic solution (p < 0.05), with tendency for better results than control after 7 days. After 30 days, the response to both extracts was similar to control. The aqueous and ethanolic aroeira extracts containing inactivated microorganisms showed a trend for better results than saline, even when associated with microorganisms, and facilitated the tissue repair process.


Oral Oncology Extra | 2005

Aesthetic and functional ocular rehabilitation

Marcelo Coelho Goiato; Daniela Nardi Mancuso; Maria Lúcia Marçal Mazza Sundefeld; Marcelo Basilio Da Motta Gabriel; Ana Cristina Murakawa; Aimée Maria Guiotti


Arq. odontol | 2004

Estudo sobre as causas mais freqüentes de perdas oculares

Marcelo Coelho Goiato; Daniela Nardi Mancuso; Aline Úrsula Rocha Fernandes; Stefan Fiuza de Carvalho Dekon