Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Dieter Wirz is active.

Publication


Featured researches published by Dieter Wirz.


Fems Microbiology Letters | 2010

Use of isothermal microcalorimetry to monitor microbial activities

Olivier Braissant; Dieter Wirz; Beat Göpfert; A. U. Daniels

Isothermal calorimetry measures the heat flow of biological processes, which is proportional to the rate at which a given chemical or physical process takes place. Modern isothermal microcalorimeters make measurements of less than a microwatt of heat flow possible. As a result, as few as 10 000-100 000 active bacterial cells in culture are sufficient to produce a real-time signal dynamically related to the number of cells present and their activity. Specimens containing bacteria need little preparation, and isothermal microcalorimetry (IMC) is a nondestructive method. After IMC measurements, the undisturbed samples can be evaluated by any other means desired. In this review, we present a basic description of microcalorimetry and examples of microbiological applications of IMC for medical and environmental microbiology. In both fields, IMC has been used to quantify microbial activity over periods of hours or even days. Finally, the recent development of highly parallel instruments (up to 48 channels) and the constantly decreasing costs of equipment have made IMC increasingly attractive for microbiology. Miniaturization of isothermal calorimeters provides an even wider range of possibilities.


Biophysical Journal | 2010

Micro- and Nanomechanical Analysis of Articular Cartilage by Indentation-Type Atomic Force Microscopy: Validation with a Gel-Microfiber Composite

Marko Loparic; Dieter Wirz; A. U. Daniels; Roberto Raiteri; Mark R. VanLandingham; Geraldine Guex; Ivan Martin; Ueli Aebi; Martin Stolz

As documented previously, articular cartilage exhibits a scale-dependent dynamic stiffness when probed by indentation-type atomic force microscopy (IT-AFM). In this study, a micrometer-size spherical tip revealed an unimodal stiffness distribution (which we refer to as microstiffness), whereas probing articular cartilage with a nanometer-size pyramidal tip resulted in a bimodal nanostiffness distribution. We concluded that indentation of the cartilages soft proteoglycan (PG) gel gave rise to the lower nanostiffness peak, whereas deformation of its collagen fibrils yielded the higher nanostiffness peak. To test our hypothesis, we produced a gel-microfiber composite consisting of a chondroitin sulfate-containing agarose gel and a fibrillar poly(ethylene glycol)-terephthalate/poly(butylene)-terephthalate block copolymer. In striking analogy to articular cartilage, the microstiffness distribution of the synthetic composite was unimodal, whereas its nanostiffness exhibited a bimodal distribution. Also, similar to the case with cartilage, addition of the negatively charged chondroitin sulfate rendered the gel-microfiber composites water content responsive to salt. When the ionic strength of the surrounding buffer solution increased from 0.15 to 2 M NaCl, the cartilages microstiffness increased by 21%, whereas that of the synthetic biomaterial went up by 31%. When the nanostiffness was measured after the ionic strength was raised by the same amount, the cartilages lower peak increased by 28%, whereas that of the synthetic biomaterial went up by 34%. Of interest, the higher peak values remained unchanged for both materials. Taken together, these results demonstrate that the nanoscale lower peak is a measure of the soft PG gel, and the nanoscale higher peak measures collagen fibril stiffness. In contrast, the micrometer-scale measurements fail to resolve separate stiffness values for the PG and collagen fibril moieties. Therefore, we propose to use nanostiffness as a new biomarker to analyze structure-function relationships in normal, diseased, and engineered cartilage.


Arthritis & Rheumatism | 2008

Engineered Cartilage generated by Nasal chondrocytes is responsive to physical forces resembling joint loading

C Candrian; D Vonwil; Andrea Barbero; E Bonacina; S Miot; J Farhadi; Dieter Wirz; Sally C. Dickinson; Anthony P. Hollander; M Jakob; Z Li; M Alini; Michael Heberer; Ivan Martin

OBJECTIVE To determine whether engineered cartilage generated by nasal chondrocytes (ECN) is responsive to different regimens of loading associated with joint kinematics and previously shown to be stimulatory of engineered cartilage generated by articular chondrocytes (ECA). METHODS Human nasal and articular chondrocytes, harvested from 5 individuals, were expanded and cultured for 2 weeks into porous polymeric scaffolds. The resulting ECN and ECA were then maintained under static conditions or exposed to the following loading regimens: regimen 1, single application of cyclic deformation for 30 minutes; regimen 2, intermittent application of cyclic deformation for a total of 10 days, followed by static culture for 2 weeks; regimen 3, application of surface motion for a total of 10 days. RESULTS Prior to loading, ECN constructs contained significantly higher amounts of glycosaminoglycan (GAG) and type II collagen compared with ECA constructs. ECN responded to regimen 1 by increasing collagen and proteoglycan synthesis, to regimen 2 by increasing the accumulation of GAG and type II collagen as well as the dynamic modulus, and to regimen 3 by increasing the expression of superficial zone protein, at the messenger RNA level and the protein level, as well as the release of hyaluronan. ECA constructs were overall less responsive to all loading regimens, likely due to the lower extracellular matrix content. CONCLUSION Human ECN is responsive to physical forces resembling joint loading and can up-regulate molecules typically involved in joint lubrication. These findings should prompt future in vivo studies exploring the possibility of using nasal chondrocytes as a cell source for articular cartilage repair.


BMC Microbiology | 2009

Isothermal micro calorimetry – a new method for MIC determinations: results for 12 antibiotics and reference strains of E. coli and S. aureus

Ueli von Ah; Dieter Wirz; A. U. Daniels

BackgroundAntimicrobial susceptibility testing of microorganisms is performed by either disc diffusion or broth dilution tests. In clinical use, the tests are often still performed manually although automated systems exist. Most systems, however, are based on turbidometric methods which have well-known drawbacks.ResultsIn this study we evaluated isothermal micro calorimetry (IMC) for the determination of minimal inhibitory concentrations (MICs) of 12 antibiotics for five micro-organisms. Here we present the data for the 12 antibiotics and two representative microorganisms E. coli (a Gram-) and S. aureus (a Gram+). IMC was able to determine the MICs correctly according to CLSI values. Since MICs require 24 hours, time was not reduced. However, IMC provided new additional data – a continuous record of heat-producing bacterial activity (e.g. growth) in calorimetry ampoules at subinhibitory antibiotic concentrations. Key features of the heatflow (P) and aggregate heat (Q) vs. time curves were identified (tdelayand ΔQ/Δt respectively). Antibiotics with similar modes of action proved to have similar effects on tdelayand/or ΔQ/Δt.ConclusionIMC can be a powerful tool for determining the effects of antibiotics on microorganisms in vitro. It easily provides accurate MICs – plus a potential means for analyzing and comparing the modes of action of antibiotics at subinhibitory concentrations. Also IMC is completely passive, so after evaluation, ampoule contents (media, bacteria, etc.) can be analyzed by any other method desired.


Biomaterials | 2010

Bioreactor based engineering of large-scale human cartilage grafts for joint resurfacing.

Rosaria Santoro; Andy L. Olivares; Gerben Brans; Dieter Wirz; Cristina Longinotti; Damien Lacroix; Ivan Martin; David Wendt

Apart from partial or total joint replacement, no surgical procedure is currently available to treat large and deep cartilage defects associated with advanced diseases such as osteoarthritis. In this work, we developed a perfusion bioreactor system to engineer human cartilage grafts in a size with clinical relevance for unicompartmental resurfacing of human knee joints (50 mm diameter × 3 mm thick). Computational fluid dynamics models were developed to optimize the flow profile when designing the perfusion chamber. Using the developed system, human chondrocytes could be seeded throughout large 50 mm diameter scaffolds with a uniform distribution. Following two weeks culture, tissues grown in the bioreactor were viable and homogeneously cartilaginous, with biomechanical properties approaching those of native cartilage. In contrast, tissues generated by conventional manual production procedures were highly inhomogeneous and contained large necrotic regions. The unprecedented engineering of human cartilage tissues in this large-scale opens the practical perspective of grafting functional biological substitutes for the clinical treatment for extensive cartilage defects, possibly in combination with surgical or pharmacological therapies to support durability of the implant. Ongoing efforts are aimed at integrating the up-scaled bioreactor based processes within a fully automated and closed manufacturing system for safe, standardized, and GMP compliant production of large-scale cartilage grafts.


Sensors | 2010

Biomedical Use of Isothermal Microcalorimeters

Olivier Braissant; Dieter Wirz; Beat Göpfert; A.U. Daniels

Isothermal microcalorimetry is becoming widely used for monitoring biological activities in vitro. Microcalorimeters are now able to measure heat production rates of less than a microwatt. As a result, metabolism and growth of relatively small numbers of cultured bacteria, protozoans, human cells and even small animals can be monitored continuously and extremely accurately at any chosen temperature. Dynamic effects on these organisms of changes in the culture environment—or of additions to it—are easily assessed over periods from hours to days. In addition microcalorimetry is a non-destructive method that does not require much sample preparation. It is also completely passive and thus allows subsequent evaluations of any kind on the undisturbed sample. In this review, we present a basic description of current microcalorimetry instruments and an overview of their use for various biomedical applications. These include detecting infections, evaluating effects of pharmaceutical or antimicrobial agents on cells, monitoring growth of cells harvested for tissue eingineering, and assessing medical and surgical device material physico-chemical stability and cellular biocompatibility.


Biomaterials | 2010

Engineering human cell-based, functionally integrated osteochondral grafts by biological bonding of engineered cartilage tissues to bony scaffolds

Celeste Scotti; Dieter Wirz; Francine Wolf; Dirk J. Schaefer; Vivienne Bürgin; A. U. Daniels; Victor Valderrabano; Christian Candrian; Marcel Jakob; Ivan Martin; Andrea Barbero

In this study, we aimed at developing and validating a technique for the engineering of osteochondral grafts based on the biological bonding of a chondral layer with a bony scaffold by cell-laid extracellular matrix. Osteochondral composites were generated by combining collagen-based matrices (Chondro-Gide) containing human chondrocytes with devitalized spongiosa cylinders (Tutobone) using a fibrin gel (Tisseel). We demonstrate that separate pre-culture of the chondral layer for 3 days prior to the generation of the composite allows for (i) more efficient cartilaginous matrix accumulation than no pre-culture, as assessed histologically and biochemically, and (ii) superior biological bonding to the bony scaffold than 14 days of pre-culture, as assessed using a peel-off mechanical test, developed to measure integration of bilayered materials. The presence of the bony scaffold induced an upregulation in the infiltrated cells of the osteoblast-related gene bone sialoprotein, indicative of the establishment of a gradient of cell phenotypes, but did not affect per se the quality of the cartilaginous matrix in the chondral layer. The described strategy to generate osteochondral plugs is simple to be implemented and--since it is based on clinically compliant cells and materials--is amenable to be readily tested in the clinic.


Journal of Clinical Microbiology | 2008

Rapid Differentiation of Methicillin-Susceptible Staphylococcus aureus from Methicillin-Resistant S. aureus and MIC Determinations by Isothermal Microcalorimetry

Ueli von Ah; Dieter Wirz; A.U. Daniels

ABSTRACT In this study, the use of isothermal microcalorimetry (IMC) for differentiation between methicillin-resistant Staphylococcus aureus (MRSA) and methicillin-susceptible S. aureus (MSSA) and MIC determination was evaluated. It was possible to differentiate between MRSA and MSSA within 4 h, whereas the standard method required 24 h. The MICs of cefoxitin were successfully determined for MRSA and MSSA by using IMC.


Annals of Surgery | 2006

Precultivation of Engineered Human Nasal Cartilage Enhances the Mechanical Properties Relevant for Use in Facial Reconstructive Surgery

Jian Farhadi; Ilario Fulco; Sylvie Miot; Dieter Wirz; Martin Haug; Sally C. Dickinson; Anthony P. Hollander; A.U. Daniels; Michael Heberer; Ivan Martin

Objective:To investigate if precultivation of human engineered nasal cartilage grafts of clinically relevant size would increase the suture retention strength at implantation and the tensile and bending stiffness 2 weeks after implantation. Summary Background Information:To be used for reconstruction of nasal cartilage defects, engineered grafts need to be reliably sutured at implantation and resist to bending/tension forces about 2 weeks after surgery, when fixation is typically removed. Methods:Nasal septum chondrocytes from 4 donors were expanded for 2 passages and statically loaded on 15 × 5 × 2-mm size nonwoven meshes of esterified hyaluronan (Hyaff-11). Constructs were implanted for 2 weeks in nude mice between muscle fascia and subcutaneous tissue either directly after cell seeding or after 2 or 4 weeks of preculture in chondrogenic medium. Engineered tissues and native nasal cartilage were assessed histologically, biochemically, and biomechanically. Results:Engineered constructs reproducibly developed with culture time into cartilaginous tissues with increasing content of glycosaminoglycans and collagen type II. Suture retention strength was significantly higher (3.6 ± 2.2-fold) in 2-week precultured constructs than in freshly seeded meshes. Following in vivo implantation, tissues further developed and maintained the original scaffold size and shape. The bending stiffness was significantly higher (1.8 ± 0.8-fold) if constructs were precultured for 2 weeks than if they were directly implanted, whereas tensile stiffness was close to native cartilage in all groups. Conclusion:In our experimental setup, preculture for 2 weeks was necessary to engineer nasal cartilage grafts with enhanced mechanical properties relevant for clinical use in facial reconstructive surgery.


Tuberculosis | 2010

“The heat is on”: Rapid microcalorimetric detection of mycobacteria in culture

Olivier Braissant; Dieter Wirz; Beat Göpfert; A. U. Daniels

Detection of mycobacterial infection can be achieved by different means; however, culture-based methods remain the gold standard. In this paper, we present a new culture-based method using real-time microcalorimetric detection of growth of Mycobacterium species including Mycobacterium tuberculosis. Microcalorimetric detection of heat production by 6 different growing species of Mycobacterium was achieved between 20 and 310h depending on their type (fast vs. slow-growing mycobacteria) and initial concentration. This study demonstrates that microcalorimetric detection of mycobacterial growth is a potential advantageous alternative to methods using fluorescent or radiolabeled growth indicators.

Collaboration


Dive into the Dieter Wirz's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

R. Imer

École Polytechnique Fédérale de Lausanne

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

U. Staufer

Swiss Center for Electronics and Microtechnology

View shared research outputs
Top Co-Authors

Avatar