Publication
Featured researches published by Ding-Cai Zhang.
Journal of Heat Transfer-transactions of The Asme | 2010
Wen-Tao Ji; Ding-Cai Zhang; Nan Feng; Jian-Fei Guo; Mitsuharu Numata; Guannan Xi; Wen-Quan Tao
Pool boiling heat transfer coefficients of R134a with different lubricant mass fractions for one smooth tube and five enhanced tubes were tested at a saturation temperature of 6°C. The lubricant used was polyvinyl ether. The lubrication mass fractions were 0.25%, 0.5%, 1.0%, 2.0%, 3.0%, 5.0%, 7.0%, and 10.0%, respectively. Within the tested heat flux range, from 9000 W/m 2 to 90,000 W/m 2 , the lubricant generally has a different influence on pool boiling heat transfer of these six tubes.
ASME 2014 International Mechanical Engineering Congress and Exposition | 2014
Wen-Tao Ji; Chuang-Yao Zhao; Qi-Bin Dai; Shu-Heng Han; Ding-Cai Zhang; Ya-Ling He; Wen-Quan Tao
The thermo-hydraulic performance of two shell and tube condensers was investigated with an experimental approach. The experiment is conducted in a water cooled centrifugal chiller test rig. The condensers are made of three-dimensional (3-D) and high fin density integral-finned (2-D) tubes. 2-D and 3-D tubes all have the diameter of 3/4 inch (19mm). The 2-D tube has external fin density of 56fpi (fins per inch), fin height 1.023mm and 48 internal ribs per circle. The 3-D enhanced tube has the external fin density of 45fpi, fin height of 0.981mm and 45 internal ribs per circle. The 3-D tube is widely used in the water cooled chillers. 2-D tube is a newly designed surface with enhanced external fin density. Condensing heat transfer coefficient of R134a outside single horizontal tube is firstly tested at saturate temperature of 40°C. At the internal water velocity of 2.2m/s, the overall heat transfer coefficients of 2-D tube is in the range of 10364.7 to 12420.9W/m2K, 4.2% ∼ 9.0% higher than 3-D tube. External condensing heat transfer coefficient is 16.3% ∼ 25.2% higher than 3-D tube. The condensers are manufactured with these two types of tubes. Both condensers have the same geometric parameters except the tubes and tube bundle space. The length of tube in the condenser is 4000mm. The tube bundles are arranged in a staggered mode. For the integral-fin tube condenser, the longitudinal tube pitch of tube arrays is 23mm in rows and the transverse is 20mm. At the same power input and cooling water inlet temperature of 32°C, the cooling power of 2-D tube condenser are respectively of 1755.4kW and 1769.4kW; 3-D tube condenser is 1727.5kW and 1770.5kW. The pressure drop increased about 11.2% ∼ 15.9% for the 2-D tube condenser compared with 3-D tube condenser. Generally, the two condensers have the same heat transfer performance, while the integral-fin tube condenser saves 15% of copper material consumption.Copyright
International Journal of Heat and Mass Transfer | 2012
Wen-Tao Ji; Ding-Cai Zhang; Ya-Ling He; Wen-Quan Tao
International Journal of Thermal Sciences | 2011
Wen-Tao Ji; Z.G. Qu; Zeng-Yao Li; Jian-Fei Guo; Ding-Cai Zhang; Wen-Quan Tao
International Journal of Heat and Mass Transfer | 2014
Wen-Tao Ji; Chuang-Yao Zhao; Ding-Cai Zhang; Zeng-Yao Li; Ya-Ling He; Wen-Quan Tao
International Communications in Heat and Mass Transfer | 2007
Ding-Cai Zhang; Wen-Tao Ji; Wen-Quan Tao
International Journal of Heat and Mass Transfer | 2016
Wen-Tao Ji; Chuang-Yao Zhao; Ding-Cai Zhang; Shun Yoshioka; Ya-Ling He; Wen-Quan Tao
Applied Thermal Engineering | 2015
Wen-Tao Ji; Zeng-Yao Li; Z.G. Qu; Jian-Fei Guo; Ding-Cai Zhang; Ya-Ling He; Wen-Quan Tao
Applied Thermal Engineering | 2012
Wen-Tao Ji; Chuang-Yao Zhao; Ding-Cai Zhang; Ya-Ling He; Wen-Quan Tao
Archive | 2008
Wen-Quan Tao; Ding-Cai Zhang; Ya-Ling He