Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Dominic A.M.J. Theuns is active.

Publication


Featured researches published by Dominic A.M.J. Theuns.


The New England Journal of Medicine | 2010

An Entirely Subcutaneous Implantable Cardioverter–Defibrillator

Gust H. Bardy; W.M. Smith; Margaret Hood; Ian Crozier; Iain Melton; Luc Jordaens; Dominic A.M.J. Theuns; Robert Park; David J. Wright; Derek T. Connelly; Simon P. Fynn; Francis Murgatroyd; Johannes Sperzel; Joerg Neuzner; Stefan G. Spitzer; Andrey V. Ardashev; A. Oduro; Lucas Boersma; Alexander H. Maass; Isabelle C. Van Gelder; Arthur A.M. Wilde; Pascal F.H.M. van Dessel; Reinoud E. Knops; Craig S. Barr; Pierpaolo Lupo; Riccardo Cappato; Andrew A. Grace

BACKGROUND Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS First, we conducted two short-term clinical trials to identify a suitable device configuration and assess energy requirements. We evaluated four subcutaneous ICD configurations in 78 patients who were candidates for ICD implantation and subsequently tested the best configuration in 49 additional patients to determine the subcutaneous defibrillation threshold in comparison with that of the standard transvenous ICD. Then we evaluated the long-term use of subcutaneous ICDs in a pilot study, involving 6 patients, which was followed by a trial involving 55 patients. RESULTS The best device configuration consisted of a parasternal electrode and a left lateral thoracic pulse generator. This configuration was as effective as a transvenous ICD for terminating induced ventricular fibrillation, albeit with a significantly higher mean (+/-SD) energy requirement (36.6+/-19.8 J vs. 11.1+/-8.5 J). Among patients who received a permanent subcutaneous ICD, ventricular fibrillation was successfully detected in 100% of 137 induced episodes. Induced ventricular fibrillation was converted twice in 58 of 59 patients (98%) with the delivery of 65-J shocks in two consecutive tests. Clinically significant adverse events included two pocket infections and four lead revisions. After a mean of 10+/-1 months, the device had successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. CONCLUSIONS In small, nonrandomized studies, an entirely subcutaneous ICD consistently detected and converted ventricular fibrillation induced during electrophysiological testing. The device also successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. (ClinicalTrials.gov numbers, NCT00399217 and NCT00853645.)


European Heart Journal | 2014

Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry

Pier D. Lambiase; Craig S. Barr; Dominic A.M.J. Theuns; Reinoud E. Knops; Petr Neuzil; Jens Brock Johansen; Margaret Hood; Susanne S. Pedersen; Stefan Kääb; Francis Murgatroyd; Helen Reeve; Nathan Carter; Lucas Boersma

Aims The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large international patient population collected as part of the EFFORTLESS S-ICD Registry. Methods and results The EFFORTLESS S-ICD Registry is a non-randomized, standard of care, multicentre Registry designed to collect long-term, system-related, clinical, and patient reported outcome data from S-ICD implanted patients since June 2009. Follow-up data are systematically collected over 60-month post-implant including Quality of Life. The study population of 472 patients of which 241 (51%) were enrolled prospectively has a mean follow-up duration of 558 days (range 13–1342 days, median 498 days), 72% male, mean age of 49 ± 18 years (range 9–88 years), 42% mean left ventricular ejection fraction. Complication-free rates were 97 and 94%, at 30 and 360 days, respectively. Three hundred and seventeen spontaneous episodes were recorded in 85 patients during the follow-up period. Of these episodes, 169 (53%) received therapy, 93 being for Ventricular Tachycardia/Fibrillation (VT/VF). One patient died of recurrent VF and severe bradycardia. Regarding discrete VT/VF episodes, first shock conversion efficacy was 88% with 100% overall successful clinical conversion after a maximum of five shocks. The 360-day inappropriate shock rate was 7% with the vast majority occurring for oversensing (62/73 episodes), primarily of cardiac signals (94% of oversensed episodes). Conclusion The first large cohort of real-world data from an International patient S-ICD population demonstrates appropriate system performance with clinical event rates and inappropriate shock rates comparable with those reported for conventional ICDs. Clinical trial registration URL: http://www.clinicaltrials.gov. Unique identifier NCT01085435.


Journal of the American College of Cardiology | 2015

Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator: 2-Year Results From a Pooled Analysis of the IDE Study and EFFORTLESS Registry

Martin C. Burke; Michael R. Gold; Bradley P. Knight; Craig S. Barr; Dominic A.M.J. Theuns; Lucas Boersma; Reinoud E. Knops; Raul Weiss; Angel R. Leon; John M. Herre; Michael Husby; Kenneth M. Stein; Pier D. Lambiase

BACKGROUND The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) is the first implantable defibrillator that avoids placing electrodes in or around the heart. Two large prospective studies (IDE [S-ICD System IDE Clinical Investigation] and EFFORTLESS [Boston Scientific Post Market S-ICD Registry]) have reported 6-month to 1-year data on the S-ICD. OBJECTIVES The objective of this study was to evaluate the safety and efficacy of the S-ICD in a large diverse population. METHODS Data from the IDE and EFFORTLESS studies were pooled. Shocks were independently adjudicated, and complications were measured with a standardized classification scheme. Enrollment date quartiles were used to assess event rates over time. RESULTS Eight hundred eighty-two patients who underwent implantation were followed for 651±345 days. Spontaneous ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) events (n=111) were treated in 59 patients; 100 (90.1%) events were terminated with 1 shock, and 109 events (98.2%) were terminated within the 5 available shocks. The estimated 3-year inappropriate shock rate was 13.1%. Estimated 3-year, all-cause mortality was 4.7% (95% confidence interval: 0.9% to 8.5%), with 26 deaths (2.9%). Device-related complications occurred in 11.1% of patients at 3 years. There were no electrode failures, and no S-ICD-related endocarditis or bacteremia occurred. Three devices (0.3%) were replaced for right ventricular pacing. The 6-month complication rate decreased by quartile of enrollment (Q1: 8.9%; Q4: 5.5%), and there was a trend toward a reduction in inappropriate shocks (Q1: 6.9% Q4: 4.5%). CONCLUSIONS The S-ICD demonstrated high efficacy for VT/VF. Complications and inappropriate shock rates were reduced consistently with strategic programming and as operator experience increased. These data provide further evidence for the safety and efficacy of the S-ICD. (Boston Scientific Post Market S-ICD Registry [EFFORTLESS]; NCT01085435; S-ICD® System IDE Clinical Study; NCT01064076).


Psychosomatic Medicine | 2004

Type D personality is associated with increased anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator and their partners

Susanne S. Pedersen; Ron T. van Domburg; Dominic A.M.J. Theuns; Luc Jordaens; Ruud A.M. Erdman

Objective: We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress. Methods: Of all surviving patients (n = 221) having had an ICD implanted between October 1998 and January 2003, 182 patients and 144 partners completed the Hospital Anxiety and Depression Scale, the Type D Personality Scale, and the Perceived Social Support Scale. Type D personality defines those who tend to experience increased negative distress and who do not express these negative emotions in social interactions. Clinical variables for the patients were obtained from medical records. Results: Thirty-one percent of patients versus 42% of partners suffered from symptoms of anxiety (p = .048); symptoms of anxiety were particularly prevalent in male partners. Twenty-eight vs. 29% suffered from depressive symptoms (p = .901). In patients, Type D personality was independently related to anxiety (OR: 7.03; 95% CI: 2.32–21.32) and depressive symptoms (OR: 7.40; 95% CI: 2.49–21.94) adjusting for all other variables. Underlying cardiac disease pathology did not explain differences in patient distress. In partners, Type D personality was independently associated with increased symptoms of anxiety (OR: 8.77; 95% CI: 3.19–24.14) and depression (OR: 4.40; 95% CI: 1.76–11.01). Conclusion: Partners experienced similar levels of depression but higher levels of anxiety compared with ICD patients. Personality was an important explanatory factor of distress in both ICD patients and their partners. Research is now warranted to investigate the implications of this finding for the clinical course of ICD patients, as Type D personality has been associated with adverse prognosis in patients with coronary artery disease. CAD = coronary artery disease; ICD = implantable cardioverter defibrillator; MI = myocardial infarction.


Journal of the American College of Cardiology | 2012

The entirely subcutaneous implantable cardioverter-defibrillator: initial clinical experience in a large Dutch cohort.

Louise R.A. Olde Nordkamp; Lara Dabiri Abkenari; Lucas Boersma; Alexander H. Maass; Joris R. de Groot; Antonie J.H.H.M. van Oostrom; Dominic A.M.J. Theuns; Luc Jordaens; Arthur A.M. Wilde; Reinoud E. Knops

OBJECTIVES The purpose of the study was to evaluate the efficacy and safety of the entirely subcutaneous implantable cardioverter-defibrillator (S-ICD). BACKGROUND A new entirely S-ICD has been introduced, that does not require lead placement in or on the heart. The authors report the largest multicenter experience to date with the S-ICD with a minimum of 1-year follow-up in the first 118 Dutch patients who were implanted with this device. METHODS Patients were selected if they had a class I or IIa indication for primary or secondary prevention of sudden cardiac death. All consecutive patients from 4 high-volume centers in the Netherlands with an S-ICD implanted between December 2008 and April 2011 were included. RESULTS A total of 118 patients (75% males, mean age 50 years) received the S-ICD. After 18 months of follow-up, 8 patients experienced 45 successful appropriate shocks (98% first shock conversion efficacy). No sudden deaths occurred. Fifteen patients (13%) received inappropriate shocks, mainly due to T-wave oversensing, which was mostly solved by a software upgrade and changing the sensing vector of the S-ICD. Sixteen patients (14%) experienced complications. Adverse events were more frequent in the first 15 implantations per center compared with subsequent implantations (inappropriate shocks 19% vs. 6.7%, p = 0.03; complications 17% vs. 10%, p = 0.10). CONCLUSIONS This study demonstrates that the S-ICD is effective in terminating ventricular arrhythmias. There is, however, a considerable percentage of ICD related adverse events, which decreases as the therapy evolves and experience increases.


Journal of Cardiovascular Electrophysiology | 2012

Head-to-head comparison of arrhythmia discrimination performance of subcutaneous and transvenous ICD arrhythmia detection algorithms: The START study

Michael R. Gold; Dominic A.M.J. Theuns; Bradley P. Knight; J. Lacy Sturdivant; Rick Sanghera; Kenneth A. Ellenbogen; Mark A. Wood; Martin C. Burke

Arrhythmia Detection with S‐ICD Versus Transvenous ICDs.


Europace | 2008

One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation

Yves Van Belle; Petter Janse; Dominic A.M.J. Theuns; Tamas Szili-Torok; Luc Jordaens

Aims Pulmonary vein isolation (PVI) with cryoenergy delivered through a balloon is a new approach in the treatment of atrial fibrillation (AF), but long-term follow-up is lacking. The aim of this study was to provide insight in the success rate and the incidence of recurrences. Methods and results Patients with symptomatic AF despite anti-arrhythmic drugs (AADs) were treated with cryoballoon PVI. Daily transtelephonic ECG monitoring, 24 h Holter-ECG, and an arrhythmia-focused questionnaire were used to document AF. One hundred and forty-one patients completed a follow-up of 457 ± 252 days. Before ablation, Holter-ECG showed AF in 45%, including 16% continuous AF throughout the recording. Event recording revealed a median AF burden of 26%. The questionnaire showed a median of weekly AF complaints lasting for hours. All but one patient had successful PVI with a single procedure. After ablation, AF (defined as lasting for more than 30 s) was seen in 11% of Holter-ECGs, with 1% continuous AF. The event recording showed an AF burden of 9%. The median patient reported no more AF-related symptoms. Recurrence during the first 3 months was predictive for later recurrence. A second procedure was performed in 24 patients. The freedom of AF was 59% without AADs after 1,2 procedures. Four right phrenic nerve paralyses occurred, all resolving within 6 months. No PV stenoses were observed. Conclusion Pulmonary vein isolation with a cryothermal balloon is an effective treatment for paroxysmal AF, resulting in a clinical success rate comparable to studies involving radiofrequency ablation. Temporary right phrenic nerve paralysis is the most important complication.


Circulation-heart Failure | 2010

Long-Term Outcome of Alcohol Septal Ablation in Patients with Obstructive Hypertrophic Cardiomyopathy: A Word of Caution

Folkert J. ten Cate; Osama Ibrahim Ibrahim Soliman; Michelle Michels; Dominic A.M.J. Theuns; Peter L. de Jong; Marcel L. Geleijnse; Patrick W. Serruys

Background—The impact of alcohol septal ablation (ASA)-induced scar is not known. This study sought to examine the long-term outcome of ASA among patients with obstructive hypertrophic cardiomyopathy. Methods and Results—Ninety-one consecutive patients (aged 54±15 years) with obstructive hypertrophic cardiomyopathy underwent ASA. Primary study end point was a composite of cardiac death and aborted sudden cardiac death including appropriate cardioverter-defibrillator discharges for fast ventricular tachycardia/ventricular fibrillation. Secondary end points were noncardiac death and other nonfatal complications. Outcomes of ASA patients were compared with 40 patients with hypertrophic cardiomyopathy who underwent septal myectomy. During 5.4±2.5 years, primary and/or secondary end points were seen in 35 (38%) ASA patients of whom 19 (21%) patients met the primary end point. The 1-, 5-, and 8-year survival-free from the primary end point was 96%, 86%, and 67%, respectively in ASA patients versus 100%, 96%, and 96%, respectively in myectomy patients during 6.6±2.7 years (log-rank, P=0.01). ASA patients had a ≈5-fold increase in the estimated annual primary end point rate (4.4% versus 0.9%) compared with myectomy patients. In a multivariable model including a propensity score, ASA was an independent predictor of the primary end point (unadjusted hazard ratio, 5.2; 95% CI, 1.2 to 22.1; P=0.02 and propensity score-adjusted hazard ratio, 6.1; 95% CI, 1.4 to 27.1; P=0.02). Conclusions—This study shows that ASA has potentially unwanted long-term effects. This poses special precaution, given the fact that ASA is practiced worldwide at increasing rate. We recommend myectomy as the preferred intervention in patients with obstructive hypertrophic cardiomyopathy.


Europace | 2010

Effectiveness of prophylactic implantation of cardioverter-defibrillators without cardiac resynchronization therapy in patients with ischaemic or non-ischaemic heart disease: a systematic review and meta-analysis

Dominic A.M.J. Theuns; Tim Smith; Myriam Hunink; Gust H. Bardy; Luc Jordaens

Aims Much controversy exists concerning the efficacy of primary prophylactic implantable cardioverter-defibrillators (ICDs) in patients with low ejection fraction due to coronary artery disease (CAD) or dilated cardiomyopathy (DCM). This is also related to the bias created by function improving interventions added to ICD therapy, e.g. resynchronization therapy. The aim was to investigate the efficacy of ICD-only therapy in primary prevention in patients with CAD or DCM. Methods and results Public domain databases, MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials, were searched from 1980 to 2009 for randomized clinical trials of ICD vs. conventional therapy. Two investigators independently abstracted the data. Pooled estimates were calculated using both fixed-effects and random-effects models. Eight trials were included in the final analysis (5343 patients). Implantable cardioverter-defibrillators significantly reduced the arrhythmic mortality [relative risk (RR): 0.40; 95% confidence interval (CI): 0.27–0.67] and all-cause mortality (RR: 0.73; 95% CI: 0.64–0.82). Regardless of aetiology of heart disease, ICD benefit was similar for CAD (RR: 0.67; 95% CI: 0.51–0.88) vs. DCM (RR: 0.74; 95% CI: 0.59–0.93). Conclusions The results of this meta-analysis provide strong evidence for the beneficial effect of ICD-only therapy on the survival of patients with ischaemic or non-ischaemic heart disease, with a left ventricular ejection fraction ≤35%, if they are 40 days from myocardial infarction and ≥3 months from a coronary revascularization procedure.


European Heart Journal | 2008

New-onset atrial fibrillation is an independent predictor of in-hospital mortality in hospitalized heart failure patients: results of the EuroHeart Failure Survey

Maximo Rivero-Ayerza; Wilma Scholte op Reimer; Mattie J. Lenzen; Dominic A.M.J. Theuns; Luc Jordaens; Michel Komajda; Ferenc Follath; Karl Swedberg; John G.F. Cleland

AIMS The prognostic significance of atrial fibrillation (AF) in hospitalized patients with heart failure (HF) remains poorly understood. To evaluate in what way AF and its different modes of presentation affect the in-hospital mortality in patients admitted with HF. METHODS AND RESULTS The EuroHeart Failure Survey was conducted to ascertain how hospitalized HF patients are managed in Europe. The survey enrolled patients over a 6-week period in 115 hospitals from 24 countries. For this analysis, patients were categorized into three groups according to the type of AF, previous AF (patients known to have had AF prior to admission), new-onset AF (no previous AF with AF diagnosed during hospitalization), and no AF (no previous AF and no AF during hospitalization). Clinical variables, duration of hospitalization, and in-hospital survival status were assessed and compared among groups. Of the 10 701 patients included in the survey; 6027 (57%) had no AF, 3673 (34%) had previous AF, and 1001 (9%) had new-onset AF. Patients with new-onset AF had a longer stay in the intensive care unit (ICU) when compared with previous AF and no AF patients (mean 2.6 +/- 5.3, 1.2 +/- 3.5, and 1.5 +/- 4.1 days, respectively; P < 0.001). In-hospital mortality was higher among patients with new-onset AF when compared with previous AF or no AF patients (12, 7, and 7% respectively; P < 0.001). After adjusting for multiple clinical variables, new-onset AF (not previous AF) was an independent predictor of in-hospital mortality (odds ratio 1.53, 95% CI 1.1-2.0). CONCLUSION In hospitalized patients with HF, new-onset AF is an independent predictor of in-hospital mortality and a longer ICU and hospital stay.

Collaboration


Dive into the Dominic A.M.J. Theuns's collaboration.

Top Co-Authors

Avatar

Luc Jordaens

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Tamas Szili-Torok

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Susanne S. Pedersen

University of Southern Denmark

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Folkert J. ten Cate

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Lucas Boersma

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Maximo Rivero-Ayerza

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Sing-Chien Yap

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Marcel L. Geleijnse

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge