Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Lucas Boersma is active.

Publication


Featured researches published by Lucas Boersma.


The New England Journal of Medicine | 2010

An Entirely Subcutaneous Implantable Cardioverter–Defibrillator

Gust H. Bardy; W.M. Smith; Margaret Hood; Ian Crozier; Iain Melton; Luc Jordaens; Dominic A.M.J. Theuns; Robert Park; David J. Wright; Derek T. Connelly; Simon P. Fynn; Francis Murgatroyd; Johannes Sperzel; Joerg Neuzner; Stefan G. Spitzer; Andrey V. Ardashev; A. Oduro; Lucas Boersma; Alexander H. Maass; Isabelle C. Van Gelder; Arthur A.M. Wilde; Pascal F.H.M. van Dessel; Reinoud E. Knops; Craig S. Barr; Pierpaolo Lupo; Riccardo Cappato; Andrew A. Grace

BACKGROUND Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS First, we conducted two short-term clinical trials to identify a suitable device configuration and assess energy requirements. We evaluated four subcutaneous ICD configurations in 78 patients who were candidates for ICD implantation and subsequently tested the best configuration in 49 additional patients to determine the subcutaneous defibrillation threshold in comparison with that of the standard transvenous ICD. Then we evaluated the long-term use of subcutaneous ICDs in a pilot study, involving 6 patients, which was followed by a trial involving 55 patients. RESULTS The best device configuration consisted of a parasternal electrode and a left lateral thoracic pulse generator. This configuration was as effective as a transvenous ICD for terminating induced ventricular fibrillation, albeit with a significantly higher mean (+/-SD) energy requirement (36.6+/-19.8 J vs. 11.1+/-8.5 J). Among patients who received a permanent subcutaneous ICD, ventricular fibrillation was successfully detected in 100% of 137 induced episodes. Induced ventricular fibrillation was converted twice in 58 of 59 patients (98%) with the delivery of 65-J shocks in two consecutive tests. Clinically significant adverse events included two pocket infections and four lead revisions. After a mean of 10+/-1 months, the device had successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. CONCLUSIONS In small, nonrandomized studies, an entirely subcutaneous ICD consistently detected and converted ventricular fibrillation induced during electrophysiological testing. The device also successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. (ClinicalTrials.gov numbers, NCT00399217 and NCT00853645.)


European Heart Journal | 2014

Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry

Pier D. Lambiase; Craig S. Barr; Dominic A.M.J. Theuns; Reinoud E. Knops; Petr Neuzil; Jens Brock Johansen; Margaret Hood; Susanne S. Pedersen; Stefan Kääb; Francis Murgatroyd; Helen Reeve; Nathan Carter; Lucas Boersma

Aims The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large international patient population collected as part of the EFFORTLESS S-ICD Registry. Methods and results The EFFORTLESS S-ICD Registry is a non-randomized, standard of care, multicentre Registry designed to collect long-term, system-related, clinical, and patient reported outcome data from S-ICD implanted patients since June 2009. Follow-up data are systematically collected over 60-month post-implant including Quality of Life. The study population of 472 patients of which 241 (51%) were enrolled prospectively has a mean follow-up duration of 558 days (range 13–1342 days, median 498 days), 72% male, mean age of 49 ± 18 years (range 9–88 years), 42% mean left ventricular ejection fraction. Complication-free rates were 97 and 94%, at 30 and 360 days, respectively. Three hundred and seventeen spontaneous episodes were recorded in 85 patients during the follow-up period. Of these episodes, 169 (53%) received therapy, 93 being for Ventricular Tachycardia/Fibrillation (VT/VF). One patient died of recurrent VF and severe bradycardia. Regarding discrete VT/VF episodes, first shock conversion efficacy was 88% with 100% overall successful clinical conversion after a maximum of five shocks. The 360-day inappropriate shock rate was 7% with the vast majority occurring for oversensing (62/73 episodes), primarily of cardiac signals (94% of oversensed episodes). Conclusion The first large cohort of real-world data from an International patient S-ICD population demonstrates appropriate system performance with clinical event rates and inappropriate shock rates comparable with those reported for conventional ICDs. Clinical trial registration URL: http://www.clinicaltrials.gov. Unique identifier NCT01085435.


Journal of the American College of Cardiology | 2015

Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator: 2-Year Results From a Pooled Analysis of the IDE Study and EFFORTLESS Registry

Martin C. Burke; Michael R. Gold; Bradley P. Knight; Craig S. Barr; Dominic A.M.J. Theuns; Lucas Boersma; Reinoud E. Knops; Raul Weiss; Angel R. Leon; John M. Herre; Michael Husby; Kenneth M. Stein; Pier D. Lambiase

BACKGROUND The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) is the first implantable defibrillator that avoids placing electrodes in or around the heart. Two large prospective studies (IDE [S-ICD System IDE Clinical Investigation] and EFFORTLESS [Boston Scientific Post Market S-ICD Registry]) have reported 6-month to 1-year data on the S-ICD. OBJECTIVES The objective of this study was to evaluate the safety and efficacy of the S-ICD in a large diverse population. METHODS Data from the IDE and EFFORTLESS studies were pooled. Shocks were independently adjudicated, and complications were measured with a standardized classification scheme. Enrollment date quartiles were used to assess event rates over time. RESULTS Eight hundred eighty-two patients who underwent implantation were followed for 651±345 days. Spontaneous ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) events (n=111) were treated in 59 patients; 100 (90.1%) events were terminated with 1 shock, and 109 events (98.2%) were terminated within the 5 available shocks. The estimated 3-year inappropriate shock rate was 13.1%. Estimated 3-year, all-cause mortality was 4.7% (95% confidence interval: 0.9% to 8.5%), with 26 deaths (2.9%). Device-related complications occurred in 11.1% of patients at 3 years. There were no electrode failures, and no S-ICD-related endocarditis or bacteremia occurred. Three devices (0.3%) were replaced for right ventricular pacing. The 6-month complication rate decreased by quartile of enrollment (Q1: 8.9%; Q4: 5.5%), and there was a trend toward a reduction in inappropriate shocks (Q1: 6.9% Q4: 4.5%). CONCLUSIONS The S-ICD demonstrated high efficacy for VT/VF. Complications and inappropriate shock rates were reduced consistently with strategic programming and as operator experience increased. These data provide further evidence for the safety and efficacy of the S-ICD. (Boston Scientific Post Market S-ICD Registry [EFFORTLESS]; NCT01085435; S-ICD® System IDE Clinical Study; NCT01064076).


Heart Rhythm | 2008

Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter

Lucas Boersma; Maurits C.E.F. Wijffels; Hakan Oral; Eric F.D. Wever; Fred Morady

BACKGROUND Pulmonary vein (PV) isolation for ablation of atrial fibrillation (AF) remains a complex and lengthy procedure. OBJECTIVE The purpose of this study was to evaluate the feasibility and safety of a novel multielectrode catheter that delivers duty-cycled bipolar and unipolar radiofrequency (RF) energy. METHODS Patients eligible for catheter ablation of paroxysmal AF after screening with magnetic resonance imaging and transesophageal echocardiography were included in the study. A decapolar (3-mm electrode, 3-mm spacing, 25-mm diameter), circular, over-the-wire mapping and ablation catheter was deployed in the antrum of each PV. Ablation was performed with 60-second, 60 degrees C applications of duty-cycled bipolar/unipolar RF in a 4:1 ratio simultaneously at all selected electrode pairs until local activity was no longer observed. At 6 months, 7-day Holter monitoring was performed to determine freedom from AF without use of antiarrhythmic drugs. RESULTS In 98 patients (mean age 59 +/- 9 years), the PV ablation catheter was used for ablation of 369 veins (20 common left antra). All targeted veins (100%) were isolated as confirmed by the absence of potentials in the ostium either by PV ablation catheter or Lasso mapping. Mean number of RF applications was 27 +/- 7, total procedural time 84 +/- 29 minutes, and fluoroscopy time 18 +/- 8 minutes. Follow-up after 6 months without antiarrhythmic drugs showed freedom from AF in 83% of patients. No procedure-related complications were observed. CONCLUSION PV isolation by duty-cycled bipolar/unipolar low-power RF energy through a circular, decapolar catheter can be achieved safely and efficiently, with good efficacy at 6 months.


Journal of the American College of Cardiology | 2012

The entirely subcutaneous implantable cardioverter-defibrillator: initial clinical experience in a large Dutch cohort.

Louise R.A. Olde Nordkamp; Lara Dabiri Abkenari; Lucas Boersma; Alexander H. Maass; Joris R. de Groot; Antonie J.H.H.M. van Oostrom; Dominic A.M.J. Theuns; Luc Jordaens; Arthur A.M. Wilde; Reinoud E. Knops

OBJECTIVES The purpose of the study was to evaluate the efficacy and safety of the entirely subcutaneous implantable cardioverter-defibrillator (S-ICD). BACKGROUND A new entirely S-ICD has been introduced, that does not require lead placement in or on the heart. The authors report the largest multicenter experience to date with the S-ICD with a minimum of 1-year follow-up in the first 118 Dutch patients who were implanted with this device. METHODS Patients were selected if they had a class I or IIa indication for primary or secondary prevention of sudden cardiac death. All consecutive patients from 4 high-volume centers in the Netherlands with an S-ICD implanted between December 2008 and April 2011 were included. RESULTS A total of 118 patients (75% males, mean age 50 years) received the S-ICD. After 18 months of follow-up, 8 patients experienced 45 successful appropriate shocks (98% first shock conversion efficacy). No sudden deaths occurred. Fifteen patients (13%) received inappropriate shocks, mainly due to T-wave oversensing, which was mostly solved by a software upgrade and changing the sensing vector of the S-ICD. Sixteen patients (14%) experienced complications. Adverse events were more frequent in the first 15 implantations per center compared with subsequent implantations (inappropriate shocks 19% vs. 6.7%, p = 0.03; complications 17% vs. 10%, p = 0.10). CONCLUSIONS This study demonstrates that the S-ICD is effective in terminating ventricular arrhythmias. There is, however, a considerable percentage of ICD related adverse events, which decreases as the therapy evolves and experience increases.


European Heart Journal | 2016

Implant success and safety of left atrial appendage closure with the WATCHMAN device: peri-procedural outcomes from the EWOLUTION registry

Lucas Boersma; Boris Schmidt; Timothy R. Betts; Horst Sievert; Corrado Tamburino; Emmanuel Teiger; Evgeny Pokushalov; Stephan Kische; Thomas Schmitz; Kenneth M. Stein; Martin W. Bergmann

Abstract Aims  Left atrial appendage closure is a non-pharmacological alternative for stroke prevention in high-risk patients with non-valvular atrial fibrillation. The objective of the multicentre EWOLUTION registry was to obtain clinical data on procedural success and complications, and long-term patient outcomes, including bleeding and incidence of stroke/transient ischaemic attack (TIA). Here, we report on the peri-procedural outcomes of up to 30 days. Methods and results  Baseline/implant data are available for 1021 subjects. Subjects in the study were at high risk of stroke (average CHADS 2 score: 2.8 ± 1.3, CHA 2 DS 2 -VASc: 4.5 ± 1.6) and moderate-to-high risk of bleeding (average HAS-BLED score: 2.3 ± 1.2). Almost half of the subjects (45.4%) had a history of TIA, ischaemic stroke, or haemorrhagic stroke; 62% of patients were deemed unsuitable for novel oral anticoagulant by their physician. The device was successfully deployed in 98.5% of patients with no flow or minimal residual flow achieved in 99.3% of implanted patients. Twenty-eight subjects experienced 31 serious adverse events (SAEs) within 1 day of the procedure. The overall 30-day mortality rate was 0.7%. The most common SAE occurring within 30 days of the procedure was major bleeding requiring transfusion. Incidence of SAEs within 30 days was significantly lower for subjects deemed to be ineligible for oral anticoagulation therapy (OAT) compared with those eligible for OAT (6.5 vs. 10.2%, P = 0.042). Conclusion  Left atrial appendage closure with the WATCHMAN device has a high success rate in complete LAAC with low peri-procedural risk, even in a population with a higher risk of stroke and bleeding, and multiple co-morbidities. Improvement in implantation techniques has led to a reduction of peri-procedural complications previously limiting the net clinical benefit of the procedure.


Europace | 2013

Personalized management of atrial fibrillation: Proceedings from the fourth Atrial Fibrillation competence NETwork/European Heart Rhythm Association consensus conference.

Paulus Kirchhof; Guenter Breithardt; Etienne Aliot; Sana Al Khatib; Stavros Apostolakis; Angelo Auricchio; Christophe Bailleul; Jeroen J. Bax; Gerlinde Benninger; Carina Blomström-Lundqvist; Lucas Boersma; Giuseppe Boriani; Axel Brandes; Helen Brown; Martina Brueckmann; Hugh Calkins; Barbara Casadei; Andreas Clemens; Harry J.G.M. Crijns; Roland Derwand; Dobromir Dobrev; Michael D. Ezekowitz; Thomas Fetsch; Andrea Gerth; Anne M. Gillis; Michele Gulizia; Guido Hack; Laurent M. Haegeli; Stéphane N. Hatem; Karl Georg Haeusler

The management of atrial fibrillation (AF) has seen marked changes in past years, with the introduction of new oral anticoagulants, new antiarrhythmic drugs, and the emergence of catheter ablation as a common intervention for rhythm control. Furthermore, new technologies enhance our ability to detect AF. Most clinical management decisions in AF patients can be based on validated parameters that encompass type of presentation, clinical factors, electrocardiogram analysis, and cardiac imaging. Despite these advances, patients with AF are still at increased risk for death, stroke, heart failure, and hospitalizations. During the fourth Atrial Fibrillation competence NETwork/European Heart Rhythm Association (AFNET/EHRA) consensus conference, we identified the following opportunities to personalize management of AF in a better manner with a view to improve outcomes by integrating atrial morphology and damage, brain imaging, information on genetic predisposition, systemic or local inflammation, and markers for cardiac strain. Each of these promising avenues requires validation in the context of existing risk factors in patients. More importantly, a new taxonomy of AF may be needed based on the pathophysiological type of AF to allow personalized management of AF to come to full fruition. Continued translational research efforts are needed to personalize management of this prevalent disease in a better manner. All the efforts are expected to improve the management of patients with AF based on personalized therapy.


The New England Journal of Medicine | 2018

Catheter Ablation for Atrial Fibrillation with Heart Failure

Nassir F. Marrouche; Johannes Brachmann; Dietrich Andresen; Jürgen Siebels; Lucas Boersma; Luc Jordaens; Béla Merkely; Evgeny Pokushalov; Prashanthan Sanders; Jochen Proff; Heribert Schunkert; Hildegard Christ; Jürgen Vogt; Dietmar Bänsch

Background Mortality and morbidity are higher among patients with atrial fibrillation and heart failure than among those with heart failure alone. Catheter ablation for atrial fibrillation has been proposed as a means of improving outcomes among patients with heart failure who are otherwise receiving appropriate treatment. Methods We randomly assigned patients with symptomatic paroxysmal or persistent atrial fibrillation who did not have a response to antiarrhythmic drugs, had unacceptable side effects, or were unwilling to take these drugs to undergo either catheter ablation (179 patients) or medical therapy (rate or rhythm control) (184 patients) for atrial fibrillation in addition to guidelines‐based therapy for heart failure. All the patients had New York Heart Association class II, III, or IV heart failure, a left ventricular ejection fraction of 35% or less, and an implanted defibrillator. The primary end point was a composite of death from any cause or hospitalization for worsening heart failure. Results After a median follow‐up of 37.8 months, the primary composite end point occurred in significantly fewer patients in the ablation group than in the medical‐therapy group (51 patients [28.5%] vs. 82 patients [44.6%]; hazard ratio, 0.62; 95% confidence interval [CI], 0.43 to 0.87; P=0.007). Significantly fewer patients in the ablation group died from any cause (24 [13.4%] vs. 46 [25.0%]; hazard ratio, 0.53; 95% CI, 0.32 to 0.86; P=0.01), were hospitalized for worsening heart failure (37 [20.7%] vs. 66 [35.9%]; hazard ratio, 0.56; 95% CI, 0.37 to 0.83; P=0.004), or died from cardiovascular causes (20 [11.2%] vs. 41 [22.3%]; hazard ratio, 0.49; 95% CI, 0.29 to 0.84; P=0.009). Conclusions Catheter ablation for atrial fibrillation in patients with heart failure was associated with a significantly lower rate of a composite end point of death from any cause or hospitalization for worsening heart failure than was medical therapy. (Funded by Biotronik; CASTLE‐AF ClinicalTrials.gov number, NCT00643188.)


American Heart Journal | 2012

Rationale and design of the PRAETORIAN trial: A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy

Louise R.A. Olde Nordkamp; Reinoud E. Knops; Gust H. Bardy; Yuri Blaauw; Lucas Boersma; Johannes S. Bos; Peter Paul H.M. Delnoy; Pascal F.H.M. van Dessel; Antoine H.G. Driessen; Joris R. de Groot; Jean Paul R. Herrman; Luc Jordaens; Kirsten M. Kooiman; Alexander H. Maass; Mathias Meine; Yuka Mizusawa; Sander G. Molhoek; Jurjen van Opstal; Jan G.P. Tijssen; Arthur A.M. Wilde

BACKGROUND Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutaneous ICD overcomes problems associated with transvenous leads. However, the role of the subcutaneous ICD as an adjunctive or primary therapy in patients at risk for sudden cardiac death is unclear. STUDY DESIGN The PRAETORIAN trial is an investigator-initiated, randomized, controlled, multicenter, prospective 2-arm trial that outlines the advantages and disadvantages of the subcutaneous ICD. Patients with a class I or IIa indication for ICD therapy without an indication for bradypacing or tachypacing are included. A total of 700 patients are randomized to either the subcutaneous or transvenous ICD (1:1). The study is powered to claim noninferiority of the subcutaneous ICD with respect to the composite primary endpoint of inappropriate shocks and ICD-related complications. After noninferiority is established, statistical analysis is done for potential superiority. Secondary endpoint comparisons of shock efficacy and patient mortality are also made. CONCLUSION The PRAETORIAN trial is a randomized trial that aims to gain scientific evidence for the use of the subcutaneous ICD compared with the transvenous ICD in a population of patients with conventional ICD with respect to major ICD-related adverse events. This trial is registered at ClinicalTrials.gov with trial ID NCT01296022.


European Heart Journal | 2015

Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study

Philippe Ritter; Gabor Z. Duray; Clemens Steinwender; Kyoko Soejima; Razali Omar; Lluis Mont; Lucas Boersma; Reinoud E. Knops; Larry Chinitz; Shuhong Zhang; Calambur Narasimhan; John D. Hummel; Michael S. Lloyd; Timothy Alexander Simmers; Andrew Voigt; Verla Laager; Kurt Stromberg; Matthew D. Bonner; Todd J. Sheldon; Dwight Reynolds

Aims Permanent cardiac pacing is the only effective treatment for symptomatic bradycardia, but complications associated with conventional transvenous pacing systems are commonly related to the pacing lead and pocket. We describe the early performance of a novel self-contained miniaturized pacemaker. Methods and results Patients having Class I or II indication for VVI pacing underwent implantation of a Micra transcatheter pacing system, from the femoral vein and fixated in the right ventricle using four protractible nitinol tines. Prespecified objectives were >85% freedom from unanticipated serious adverse device events (safety) and <2 V 3-month mean pacing capture threshold at 0.24 ms pulse width (efficacy). Patients were implanted (n = 140) from 23 centres in 11 countries (61% male, age 77.0 ± 10.2 years) for atrioventricular block (66%) or sinus node dysfunction (29%) indications. During mean follow-up of 1.9 ± 1.8 months, the safety endpoint was met with no unanticipated serious adverse device events. Thirty adverse events related to the system or procedure occurred, mostly due to transient dysrhythmias or femoral access complications. One pericardial effusion without tamponade occurred after 18 device deployments. In 60 patients followed to 3 months, mean pacing threshold was 0.51 ± 0.22 V, and no threshold was ≥2 V, meeting the efficacy endpoint (P < 0.001). Average R-wave was 16.1 ± 5.2 mV and impedance was 650.7 ± 130 ohms. Conclusion Early assessment shows the transcatheter pacemaker can safely and effectively be applied. Long-term safety and benefit of the pacemaker will further be evaluated in the trial. Clinical Trial Registration ClinicalTrials.gov ID NCT02004873.

Collaboration


Dive into the Lucas Boersma's collaboration.

Top Co-Authors

Avatar

Maurits C.E.F. Wijffels

Leiden University Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

J. Brugada

Cardiovascular Institute of the South

View shared research outputs
Researchain Logo
Decentralizing Knowledge