Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Dominik C. Benz is active.

Publication


Featured researches published by Dominik C. Benz.


Academic Radiology | 2016

Minimized Radiation and Contrast Agent Exposure for Coronary Computed Tomography Angiography: First Clinical Experience on a Latest Generation 256-slice Scanner

Dominik C. Benz; Christoph Gräni; Beatrice Hirt Moch; Fran Mikulicic; Jan Vontobel; Tobias A. Fuchs; Julia Stehli; Olivier F. Clerc; Mathias Possner; Aju P. Pazhenkottil; Oliver Gaemperli; Ronny R. Buechel; Philipp A. Kaufmann

RATIONALE AND OBJECTIVES The aim of the study was to evaluate the impact of the latest coronary computed tomography angiography (CCTA) techniques allowing a radiation- and contrast-sparing protocol on image quality in unselected patients referred for exclusion of suspected coronary artery disease (CAD). MATERIALS AND METHODS This prospective study was approved by the local ethics committee, and all patients provided written informed consent. Between March and June 2015, 89 consecutive patients (61% male; mean age 55 ± 11 years) referred for exclusion of CAD by 256-slice CCTA using prospective electrocardiogram triggering were included. Tube voltage (80-120 kVp), tube current (180-310 mA) as well contrast agent volume (25-45 mL) and flow rate (3.5-5 mL/s) were adapted to body mass index. Signal intensity was measured by placing a region of interest in the aortic root, the left main artery, and the proximal right coronary artery. Image noise was measured in the aortic root. Two independent blinded readers semi-quantitatively assessed the image quality regarding motion, noise, and contrast on a 4-point scale. RESULTS Median contrast agent volume and median effective radiation dose were 35 mL (interquartile range, 30-40 mL) and 0.5 mSv (interquartile range, 0.4-0.6 mSv), respectively. Mean attenuation in the aortic root was 412 ± 89 Hounsfield units. Diagnostic image quality was obtained in 1050 of 1067 (98.4%) coronary segments and, on an intention-to-diagnosis basis, in 85 of 89 (95.5%) patients. Below a cut-off heart rate of 67 beats/min, only 1 of 974 (0.1%) coronary segments was nondiagnostic. CONCLUSION A radiation- and contrast-sparing protocol for CCTA on a latest generation 256-slice computed tomography scanner yields diagnostic image quality in patients referred for CAD exclusion in daily clinical routine.


Clinical Neurophysiology | 2013

No increased sensitivity in brain activity of adolescents exposed to mobile phone-like emissions

Sarah P. Loughran; Dominik C. Benz; Marc R. Schmid; Manuel Murbach; Niels Kuster; Peter Achermann

OBJECTIVE To examine the potential sensitivity of adolescents to radiofrequency electromagnetic field (RF EMF) exposures, such as those emitted by mobile phones. METHODS In a double-blind, randomized, crossover design, 22 adolescents aged 11-13 years (12 males) underwent three experimental sessions in which they were exposed to mobile phone-like RF EMF signals at two different intensities, and a sham session. During exposure cognitive tasks were performed and waking EEG was recorded at three time-points subsequent to exposure (0, 30 and 60 min). RESULTS No clear significant effects of RF EMF exposure were found on the waking EEG or cognitive performance. CONCLUSIONS Overall, the current study was unable to demonstrate exposure-related effects previously observed on the waking EEG in adults, and also provides further support for a lack of an influence of mobile phone-like exposure on cognitive performance. SIGNIFICANCE Adolescents do not appear to be more sensitive than adults to mobile phone RF EMF emissions.


European Heart Journal | 2015

Ultra-low-dose hybrid single photon emission computed tomography and coronary computed tomography angiography: a comprehensive and non-invasive diagnostic workup of suspected coronary artery disease

Dominik C. Benz; Christian Templin; Philipp A. Kaufmann; Ronny R. Buechel

A 52-year-old male patient (body mass index: 23.5 kg/m2) without known coronary artery disease (CAD) or any cardiovascular risk factors was referred for non-invasive evaluation due to typical angina. The initial computed tomography (CT) for coronary artery calcium scoring (CACS) showed no calcifications. Subsequently, …


Journal of Computer Assisted Tomography | 2016

Adaptive Statistical Iterative Reconstruction-V: Impact on Image Quality in Ultralow-Dose Coronary Computed Tomography Angiography.

Dominik C. Benz; Christoph Gräni; Fran Mikulicic; Jan Vontobel; Tobias A. Fuchs; Mathias Possner; Olivier F. Clerc; Julia Stehli; Oliver Gaemperli; Aju P. Pazhenkottil; Ronny R. Buechel; Philipp A. Kaufmann

Objective The clinical utility of a latest generation iterative reconstruction algorithm (adaptive statistical iterative reconstruction [ASiR-V]) has yet to be elucidated for coronary computed tomography angiography (CCTA). This study evaluates the impact of ASiR-V on signal, noise and image quality in CCTA. Methods Sixty-five patients underwent clinically indicated CCTA on a 256-slice CT scanner using an ultralow-dose protocol. Data sets from each patient were reconstructed at 6 different levels of ASiR-V. Signal intensity was measured by placing a region of interest in the aortic root, LMA, and RCA. Similarly, noise was measured in the aortic root. Image quality was visually assessed by 2 readers. Results Median radiation dose was 0.49 mSv. Image noise decreased with increasing levels of ASiR-V resulting in a significant increase in signal-to-noise ratio in the RCA and LMA (P < 0.001). Correspondingly, image quality significantly increased with higher levels of ASiR-V (P < 0.001). Conclusions ASiR-V yields substantial noise reduction and improved image quality enabling introduction of ultralow-dose CCTA.


Swiss Medical Weekly | 2016

Prevalence and characteristics of coronary artery anomalies detected by coronary computed tomography angiography in 5 634 consecutive patients in a single centre in Switzerland.

Christoph Gräni; Dominik C. Benz; Christian Schmied; Jan Vontobel; Mathias Possner; Olivier F. Clerc; Fran Mikulicic; Julia Stehli; Tobias A. Fuchs; Aju P. Pazhenkottil; Oliver Gaemperli; Philipp A. Kaufmann; Ronny R. Buechel

STUDY PRINCIPLES Coronary computed tomography angiography (CCTA) allows three-dimensional visualisation of the origin, course and ending of the coronary vessels with high spatial resolution, yielding an accurate depiction of coronary artery anomalies (CAAs). This study sought to determine the prevalence, incidence and characteristics of CAAs detected with CCTA in a single centre in Switzerland. METHODS CAAs were retrospectively identified in 5 634 consecutive patients referred for CCTA between March 2007 and July 2015. Single coronary arteries, Bland-White-Garland syndrome, anomalous coronary arteries originating from the opposite site of the sinus of Valsalva (ACAOS) with an interarterial course and coronary artery fistulas were classified as potentially malignant CAAs. RESULTS We identified 145 patients with CAAs, resulting in an overall prevalence of 2.6% and cumulative incidence of 2.1% in all patients referred for CCTA in the observation period. Forty-nine (33.8%) patients showed malignant CAAs including 1 (0.7%) patient with Bland-White-Garland syndrome, 7 (4.8%) with single coronary arteries, 36 (24.8%) with ACAOS and an interarterial course, and 5 (3.5%) with coronary artery fistulas. The remaining 96 (66.2%) patients were classified as having benign variants. CONCLUSIONS The prevalence of CAA detected by CCTA is not negligible. Because of its noninvasive nature, relatively low cost and low radiation exposure, a further increase in the utilisation of CCTA may be expected, which may consequently be paralleled by an increasing absolute number of incidentally detected CAAs. Hence, awareness of the main issues and possible management strategies regarding CAAs is of importance for every treating physician.


Journal of Nuclear Cardiology | 2017

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Dominik C. Benz; Christoph Gräni; Paola Ferro; Luis Neumeier; Michael Messerli; Mathias Possner; Olivier F. Clerc; Catherine Gebhard; Oliver Gaemperli; Aju P. Pazhenkottil; Philipp A. Kaufmann; Ronny R. Buechel

AbstractBackgroundTo assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI).Methods and ResultsThis retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. ConclusionsCCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.


International Journal of Cardiology | 2017

Long-term outcome prediction by functional parameters derived from coronary computed tomography angiography

Dominik C. Benz; Fran Mikulicic; Christoph Gräni; Dominic Moret; Mathias Possner; Olivier F. Clerc; Annina Studer Bruengger; Oliver Gaemperli; Ronny R. Buechel; Aju P. Pazhenkottil; Philipp A. Kaufmann

BACKGROUND Estimation of hemodynamic relevance of a coronary stenosis from coronary computed angiography (CCTA) has raised substantial interest. Recently, the corrected coronary opacification (CCO) decrease and the transluminal attenuation gradient (TAG) have been suggested as faster alternatives to the FFRCT. The aim of the study was to evaluate whether the diagnostic accuracy of CCO decrease and TAG translates into an added prognostic value in patients evaluated for coronary artery disease (CAD). METHODS This retrospective study consists of 162 consecutive patients referred for evaluation of known or suspected CAD by CCTA. CCO decrease was defined as difference of mean luminal coronary attenuation normalized to aorta attenuation proximal-distal of a stenosis. To calculate TAG, mean attenuation was measured at 5-mm intervals from the ostium to a distal segment with a minimal cross-sectional area of 2.0mm2. Death, myocardial infarction, unstable angina requiring hospitalization, and coronary revascularization were defined as major adverse cardiac events (MACE). Multivariate analysis included covariates age, sex, ≥3 cardiovascular risk factors and stenosis severity. RESULTS Follow-up was completed in 154 patients, CAD was found in 72. During median follow-up of 6.1years (interquartile range, 5.8-6.9years), 55 patients experienced a MACE. Among CAD patients, the presence of an abnormal CCO decrease (p<0.05) but not TAG (p=0.894) was associated with a worse MACE-free survival. In multivariate analysis, CCO decrease was an independent predictor of MACE (HR, 2.27; 95% CI, 1.14-4.52; p=0.02) while TAG was not predictive (p=0.895). CONCLUSION In CAD patients, CCO decrease adds long-term prognostic value over clinical characteristics and stenosis severity while TAG does not.


European Journal of Echocardiography | 2017

Real-time respiratory triggered SPECT myocardial perfusion imaging using CZT technology: impact of respiratory phase matching between SPECT and low-dose CT for attenuation correction

Olivier F. Clerc; Tobias A. Fuchs; Mathias Possner; Jan Vontobel; Fran Mikulicic; Julia Stehli; Riccardo Liga; Dominik C. Benz; Christoph Gräni; Aju P. Pazhenkottil; Oliver Gaemperli; Ronny R. Buechel; Philipp A. Kaufmann

Aims To assess the impact of respiratory phase matching between single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) and low-dose computed tomography (CT) for attenuation correction (AC). Methods and results Forty patients underwent 1-day 99mTc-tetrofosmin pharmacological stress/rest SPECT-MPI using a cadmium–zinc–telluride gamma camera. Low-dose CT for AC was performed at deep-inspiration breath-hold. SPECT-MPI was acquired once with free-breathing (FB) and repeated at deep-inspiration breath-hold (BH) to match the respiratory phase of AC. From these acquisitions we reconstructed four data sets: free-breathing SPECT-MPI without AC (non-corrected; FB-NC), breath-hold SPECT-MPI without AC (non-corrected; BH-NC), free-breathing SPECT-MPI with AC (FB-AC), and breath-hold SPECT-MPI with AC (BH-AC), the latter representing respiratory-phase-matched AC SPECT-MPI. We compared semi-quantitative segmental tracer uptake, visual diagnosis, inter-observer agreement, and image quality. Compared with FB-NC, deep-inspiration BH-NC increases inferior and lateral uptake, but decreases septal uptake. Addition of AC to FB increases inferior and septal uptake, but decreases anterolateral uptake. Combining breath-hold MPI with breath-hold CT AC (BH-AC) increases inferior, inferolateral, and septal uptake, but reduces apical uptake, without affecting anterolateral uptake, with significant differences to all other protocols. Frequency of normal scans increases across protocols: 10% with FB-NC, 21% with BH-NC, 38% with FB-AC, and 51% with BH-AC. Image quality and inter-observer agreement were highest for BH-AC among all protocols. Conclusion Compared with non-corrected breath-hold SPECT-MPI and with free-breathing AC SPECT-MPI, respiratory-phase-matched AC SPECT-MPI significantly affects segmental semi-quantitative uptake, increases the frequency of normal scans, yields the best inter-observer agreement, and significantly improves image quality. These findings suggest a potential role of respiratory triggered SPECT-MPI in clinical routine.


European Heart Journal | 2017

Outcome in middle-aged individuals with anomalous origin of the coronary artery from the opposite sinus: a matched cohort study

Christoph Gräni; Dominik C. Benz; Dominik A. Steffen; Olivier F. Clerc; Christian Schmied; Mathias Possner; Jan Vontobel; Fran Mikulicic; Catherine Gebhard; Aju P. Pazhenkottil; Oliver Gaemperli; Shelley Hurwitz; Philipp A. Kaufmann; Ronny R. Buechel

Aims Anomalous origin of a coronary artery from the opposite sinus (ACAOS) has been associated with adverse cardiac events in the young. It remains unknown whether this holds true for middle-aged patients with uncorrected ACAOS as well. We assessed the outcome in middle-aged patients with newly diagnosed ACAOS by coronary computed tomography angiography (CCTA) compared with a matched cohort. Methods and results We retrospectively identified 68 consecutive patients with ACAOS documented by CCTA. ACAOS with a course of the anomalous vessel between the aorta and pulmonary artery were classified as interarterial course (IAC). Each patient with ACAOS was matched to two controls without ACAOS. Major adverse cardiac events (i.e. myocardial infarction, revascularization and cardiac death) were recorded for all patients and controls. Two (3%) patients were lost to follow-up. Thus, 66 patients with ACAOS were included in the final analysis and matched with 132 controls. Mean age of patients was 56 ± 11 years, 73% were male and the mean follow-up was 49 months. Forty (65%) patients were classified as having ACAOS with IAC. The annual event rate of ACAOS vs. controls was 4.9 and 4.8%, the hazard ratio (HR) 0.94 (0.39-2.28, P = 0.89). The annual event rate of ACAOS with IAC compared with their matched controls was 5.2 and 4.3%, and the HR 1.01 (95% CI 0.39-2.58, P = 0.99). Conclusions In middle-aged individuals with newly diagnosed ACAOS mid-term outcome is not statistically different to a matched control cohort without coronary artery anomalies, regardless of whether ACAOS with or without IAC variants are present.


European Heart Journal | 2013

Isolated persistent left superior vena cava draining into the left atrium of an otherwise normal heart.

Dominik C. Benz; Nazmi Krasniqi; Ute Wagnetz; Ruedi Stieger; Felix C. Tanner; Urs Eriksson

A 63-year-old male presented with progressive right-sided hemiparesis, facial palsy, and aphasia. He had been scheduled for neoadjuvant chemotherapy for relapsing adenocarcinoma of the left colic flexure, and a left-sided port-a-cath was implanted 7 days ago. The CCT scan revealed several already well-demarked ischaemic brain lesions. Treatment with aspirin and statin was …

Collaboration


Dive into the Dominik C. Benz's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge