Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Fran Mikulicic is active.

Publication


Featured researches published by Fran Mikulicic.


Academic Radiology | 2016

Minimized Radiation and Contrast Agent Exposure for Coronary Computed Tomography Angiography: First Clinical Experience on a Latest Generation 256-slice Scanner

Dominik C. Benz; Christoph Gräni; Beatrice Hirt Moch; Fran Mikulicic; Jan Vontobel; Tobias A. Fuchs; Julia Stehli; Olivier F. Clerc; Mathias Possner; Aju P. Pazhenkottil; Oliver Gaemperli; Ronny R. Buechel; Philipp A. Kaufmann

RATIONALE AND OBJECTIVES The aim of the study was to evaluate the impact of the latest coronary computed tomography angiography (CCTA) techniques allowing a radiation- and contrast-sparing protocol on image quality in unselected patients referred for exclusion of suspected coronary artery disease (CAD). MATERIALS AND METHODS This prospective study was approved by the local ethics committee, and all patients provided written informed consent. Between March and June 2015, 89 consecutive patients (61% male; mean age 55 ± 11 years) referred for exclusion of CAD by 256-slice CCTA using prospective electrocardiogram triggering were included. Tube voltage (80-120 kVp), tube current (180-310 mA) as well contrast agent volume (25-45 mL) and flow rate (3.5-5 mL/s) were adapted to body mass index. Signal intensity was measured by placing a region of interest in the aortic root, the left main artery, and the proximal right coronary artery. Image noise was measured in the aortic root. Two independent blinded readers semi-quantitatively assessed the image quality regarding motion, noise, and contrast on a 4-point scale. RESULTS Median contrast agent volume and median effective radiation dose were 35 mL (interquartile range, 30-40 mL) and 0.5 mSv (interquartile range, 0.4-0.6 mSv), respectively. Mean attenuation in the aortic root was 412 ± 89 Hounsfield units. Diagnostic image quality was obtained in 1050 of 1067 (98.4%) coronary segments and, on an intention-to-diagnosis basis, in 85 of 89 (95.5%) patients. Below a cut-off heart rate of 67 beats/min, only 1 of 974 (0.1%) coronary segments was nondiagnostic. CONCLUSION A radiation- and contrast-sparing protocol for CCTA on a latest generation 256-slice computed tomography scanner yields diagnostic image quality in patients referred for CAD exclusion in daily clinical routine.


Eurointervention | 2016

Impact of percutaneous mitral valve repair using the MitraClip system on tricuspid regurgitation

Antonio H. Frangieh; Christiane Gruner; Fran Mikulicic; Adrian Attinger-Toller; Felix C. Tanner; Maurizio Taramasso; Roberto Corti; Jürg Grünenfelder; Thomas F Lüsche; Frank Ruschitzka; Dominique Bettex; Francesco Maisano; Oliver Gaemperli

AIMS Tricuspid regurgitation (TR) severity and right ventricular (RV) dysfunction have been identified as significant predictors of outcome after mitral valve surgery. The aim of the present study was to investigate the impact of percutaneous mitral valve repair (PMVR) with the MitraClip system on functional TR severity and RV function. METHODS AND RESULTS Among 119 consecutive patients with severe mitral regurgitation who underwent PMVR, 67 had complete baseline and follow-up transthoracic echocardiography after 3-12 months (6.8±2.9 months). TR severity was graded as mild, moderate, and severe. RV systolic function was assessed by fractional area change (FAC) and tricuspid annular plane systolic excursion (TAPSE). Clinical endpoints at follow-up included mortality, reoperation of the mitral valve, hospitalisation for congestive heart failure and New York Heart Association (NYHA) functional class. After PMVR, a significant decrease in TR severity (by at least one grade) was observed in 22 (33%) patients, while an increase occurred in only seven (10%) patients (p=0.02). Overall, systolic RV function (FAC and TAPSE), RV dimensions, and tricuspid annular diameter did not change significantly. Baseline SPAP was significantly higher (57±15 vs. 43±14 mmHg, p=0.002) and SPAP reduction significantly larger (-14±13 versus 1±15 mmHg, p=0.012) in patients who improved their TR. Multivariate logistic regression analysis identified the change in SPAP as the only significant predictor of changes in TR (odds ratio [OR] [for every change in SPAP by 10 mmHg] 1.90, 95% CI: 1.02±3.54; p=0.044). Patients with mild/moderate TR at follow-up after PMVR had lower event rates compared to those with severe TR (35% vs. 78%, respectively, p=0.025). CONCLUSIONS PMVR using the MitraClip device improves functional TR severity in approximately one third of patients, particularly in those who experience a significant SPAP reduction after the procedure.


Journal of Computer Assisted Tomography | 2016

Adaptive Statistical Iterative Reconstruction-V: Impact on Image Quality in Ultralow-Dose Coronary Computed Tomography Angiography.

Dominik C. Benz; Christoph Gräni; Fran Mikulicic; Jan Vontobel; Tobias A. Fuchs; Mathias Possner; Olivier F. Clerc; Julia Stehli; Oliver Gaemperli; Aju P. Pazhenkottil; Ronny R. Buechel; Philipp A. Kaufmann

Objective The clinical utility of a latest generation iterative reconstruction algorithm (adaptive statistical iterative reconstruction [ASiR-V]) has yet to be elucidated for coronary computed tomography angiography (CCTA). This study evaluates the impact of ASiR-V on signal, noise and image quality in CCTA. Methods Sixty-five patients underwent clinically indicated CCTA on a 256-slice CT scanner using an ultralow-dose protocol. Data sets from each patient were reconstructed at 6 different levels of ASiR-V. Signal intensity was measured by placing a region of interest in the aortic root, LMA, and RCA. Similarly, noise was measured in the aortic root. Image quality was visually assessed by 2 readers. Results Median radiation dose was 0.49 mSv. Image noise decreased with increasing levels of ASiR-V resulting in a significant increase in signal-to-noise ratio in the RCA and LMA (P < 0.001). Correspondingly, image quality significantly increased with higher levels of ASiR-V (P < 0.001). Conclusions ASiR-V yields substantial noise reduction and improved image quality enabling introduction of ultralow-dose CCTA.


Swiss Medical Weekly | 2016

Prevalence and characteristics of coronary artery anomalies detected by coronary computed tomography angiography in 5 634 consecutive patients in a single centre in Switzerland.

Christoph Gräni; Dominik C. Benz; Christian Schmied; Jan Vontobel; Mathias Possner; Olivier F. Clerc; Fran Mikulicic; Julia Stehli; Tobias A. Fuchs; Aju P. Pazhenkottil; Oliver Gaemperli; Philipp A. Kaufmann; Ronny R. Buechel

STUDY PRINCIPLES Coronary computed tomography angiography (CCTA) allows three-dimensional visualisation of the origin, course and ending of the coronary vessels with high spatial resolution, yielding an accurate depiction of coronary artery anomalies (CAAs). This study sought to determine the prevalence, incidence and characteristics of CAAs detected with CCTA in a single centre in Switzerland. METHODS CAAs were retrospectively identified in 5 634 consecutive patients referred for CCTA between March 2007 and July 2015. Single coronary arteries, Bland-White-Garland syndrome, anomalous coronary arteries originating from the opposite site of the sinus of Valsalva (ACAOS) with an interarterial course and coronary artery fistulas were classified as potentially malignant CAAs. RESULTS We identified 145 patients with CAAs, resulting in an overall prevalence of 2.6% and cumulative incidence of 2.1% in all patients referred for CCTA in the observation period. Forty-nine (33.8%) patients showed malignant CAAs including 1 (0.7%) patient with Bland-White-Garland syndrome, 7 (4.8%) with single coronary arteries, 36 (24.8%) with ACAOS and an interarterial course, and 5 (3.5%) with coronary artery fistulas. The remaining 96 (66.2%) patients were classified as having benign variants. CONCLUSIONS The prevalence of CAA detected by CCTA is not negligible. Because of its noninvasive nature, relatively low cost and low radiation exposure, a further increase in the utilisation of CCTA may be expected, which may consequently be paralleled by an increasing absolute number of incidentally detected CAAs. Hence, awareness of the main issues and possible management strategies regarding CAAs is of importance for every treating physician.


International Journal of Cardiology | 2017

Long-term outcome prediction by functional parameters derived from coronary computed tomography angiography

Dominik C. Benz; Fran Mikulicic; Christoph Gräni; Dominic Moret; Mathias Possner; Olivier F. Clerc; Annina Studer Bruengger; Oliver Gaemperli; Ronny R. Buechel; Aju P. Pazhenkottil; Philipp A. Kaufmann

BACKGROUND Estimation of hemodynamic relevance of a coronary stenosis from coronary computed angiography (CCTA) has raised substantial interest. Recently, the corrected coronary opacification (CCO) decrease and the transluminal attenuation gradient (TAG) have been suggested as faster alternatives to the FFRCT. The aim of the study was to evaluate whether the diagnostic accuracy of CCO decrease and TAG translates into an added prognostic value in patients evaluated for coronary artery disease (CAD). METHODS This retrospective study consists of 162 consecutive patients referred for evaluation of known or suspected CAD by CCTA. CCO decrease was defined as difference of mean luminal coronary attenuation normalized to aorta attenuation proximal-distal of a stenosis. To calculate TAG, mean attenuation was measured at 5-mm intervals from the ostium to a distal segment with a minimal cross-sectional area of 2.0mm2. Death, myocardial infarction, unstable angina requiring hospitalization, and coronary revascularization were defined as major adverse cardiac events (MACE). Multivariate analysis included covariates age, sex, ≥3 cardiovascular risk factors and stenosis severity. RESULTS Follow-up was completed in 154 patients, CAD was found in 72. During median follow-up of 6.1years (interquartile range, 5.8-6.9years), 55 patients experienced a MACE. Among CAD patients, the presence of an abnormal CCO decrease (p<0.05) but not TAG (p=0.894) was associated with a worse MACE-free survival. In multivariate analysis, CCO decrease was an independent predictor of MACE (HR, 2.27; 95% CI, 1.14-4.52; p=0.02) while TAG was not predictive (p=0.895). CONCLUSION In CAD patients, CCO decrease adds long-term prognostic value over clinical characteristics and stenosis severity while TAG does not.


European Journal of Echocardiography | 2017

Real-time respiratory triggered SPECT myocardial perfusion imaging using CZT technology: impact of respiratory phase matching between SPECT and low-dose CT for attenuation correction

Olivier F. Clerc; Tobias A. Fuchs; Mathias Possner; Jan Vontobel; Fran Mikulicic; Julia Stehli; Riccardo Liga; Dominik C. Benz; Christoph Gräni; Aju P. Pazhenkottil; Oliver Gaemperli; Ronny R. Buechel; Philipp A. Kaufmann

Aims To assess the impact of respiratory phase matching between single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) and low-dose computed tomography (CT) for attenuation correction (AC). Methods and results Forty patients underwent 1-day 99mTc-tetrofosmin pharmacological stress/rest SPECT-MPI using a cadmium–zinc–telluride gamma camera. Low-dose CT for AC was performed at deep-inspiration breath-hold. SPECT-MPI was acquired once with free-breathing (FB) and repeated at deep-inspiration breath-hold (BH) to match the respiratory phase of AC. From these acquisitions we reconstructed four data sets: free-breathing SPECT-MPI without AC (non-corrected; FB-NC), breath-hold SPECT-MPI without AC (non-corrected; BH-NC), free-breathing SPECT-MPI with AC (FB-AC), and breath-hold SPECT-MPI with AC (BH-AC), the latter representing respiratory-phase-matched AC SPECT-MPI. We compared semi-quantitative segmental tracer uptake, visual diagnosis, inter-observer agreement, and image quality. Compared with FB-NC, deep-inspiration BH-NC increases inferior and lateral uptake, but decreases septal uptake. Addition of AC to FB increases inferior and septal uptake, but decreases anterolateral uptake. Combining breath-hold MPI with breath-hold CT AC (BH-AC) increases inferior, inferolateral, and septal uptake, but reduces apical uptake, without affecting anterolateral uptake, with significant differences to all other protocols. Frequency of normal scans increases across protocols: 10% with FB-NC, 21% with BH-NC, 38% with FB-AC, and 51% with BH-AC. Image quality and inter-observer agreement were highest for BH-AC among all protocols. Conclusion Compared with non-corrected breath-hold SPECT-MPI and with free-breathing AC SPECT-MPI, respiratory-phase-matched AC SPECT-MPI significantly affects segmental semi-quantitative uptake, increases the frequency of normal scans, yields the best inter-observer agreement, and significantly improves image quality. These findings suggest a potential role of respiratory triggered SPECT-MPI in clinical routine.


European Heart Journal | 2017

Outcome in middle-aged individuals with anomalous origin of the coronary artery from the opposite sinus: a matched cohort study

Christoph Gräni; Dominik C. Benz; Dominik A. Steffen; Olivier F. Clerc; Christian Schmied; Mathias Possner; Jan Vontobel; Fran Mikulicic; Catherine Gebhard; Aju P. Pazhenkottil; Oliver Gaemperli; Shelley Hurwitz; Philipp A. Kaufmann; Ronny R. Buechel

Aims Anomalous origin of a coronary artery from the opposite sinus (ACAOS) has been associated with adverse cardiac events in the young. It remains unknown whether this holds true for middle-aged patients with uncorrected ACAOS as well. We assessed the outcome in middle-aged patients with newly diagnosed ACAOS by coronary computed tomography angiography (CCTA) compared with a matched cohort. Methods and results We retrospectively identified 68 consecutive patients with ACAOS documented by CCTA. ACAOS with a course of the anomalous vessel between the aorta and pulmonary artery were classified as interarterial course (IAC). Each patient with ACAOS was matched to two controls without ACAOS. Major adverse cardiac events (i.e. myocardial infarction, revascularization and cardiac death) were recorded for all patients and controls. Two (3%) patients were lost to follow-up. Thus, 66 patients with ACAOS were included in the final analysis and matched with 132 controls. Mean age of patients was 56 ± 11 years, 73% were male and the mean follow-up was 49 months. Forty (65%) patients were classified as having ACAOS with IAC. The annual event rate of ACAOS vs. controls was 4.9 and 4.8%, the hazard ratio (HR) 0.94 (0.39-2.28, P = 0.89). The annual event rate of ACAOS with IAC compared with their matched controls was 5.2 and 4.3%, and the HR 1.01 (95% CI 0.39-2.58, P = 0.99). Conclusions In middle-aged individuals with newly diagnosed ACAOS mid-term outcome is not statistically different to a matched control cohort without coronary artery anomalies, regardless of whether ACAOS with or without IAC variants are present.


European Journal of Echocardiography | 2018

Head-to-head comparison of adaptive statistical and model-based iterative reconstruction algorithms for submillisievert coronary CT angiography

Dominik C. Benz; Tobias A. Fuchs; Christoph Gräni; Annina Studer Bruengger; Olivier F. Clerc; Fran Mikulicic; Michael Messerli; Julia Stehli; Mathias Possner; Aju P. Pazhenkottil; Oliver Gaemperli; Philipp A. Kaufmann; Ronny R. Buechel

Aims Iterative reconstruction (IR) algorithms allow for a significant reduction in radiation dose of coronary computed tomography angiography (CCTA). We performed a head-to-head comparison of adaptive statistical IR (ASiR) and model-based IR (MBIR) algorithms to assess their impact on quantitative image parameters and diagnostic accuracy for submillisievert CCTA. Methods and results CCTA datasets of 91 patients were reconstructed using filtered back projection (FBP), increasing contributions of ASiR (20, 40, 60, 80, and 100%), and MBIR. Signal and noise were measured in the aortic root to calculate signal-to-noise ratio (SNR). In a subgroup of 36 patients, diagnostic accuracy of ASiR 40%, ASiR 100%, and MBIR for diagnosis of coronary artery disease (CAD) was compared with invasive coronary angiography. Median radiation dose was 0.21 mSv for CCTA. While increasing levels of ASiR gradually reduced image noise compared with FBP (up to - 48%, P < 0.001), MBIR provided largest noise reduction (-79% compared with FBP) outperforming ASiR (-59% compared with ASiR 100%; P < 0.001). Increased noise and lower SNR with ASiR 40% and ASiR 100% resulted in substantially lower diagnostic accuracy to detect CAD as diagnosed by invasive coronary angiography compared with MBIR: sensitivity and specificity were 100 and 37%, 100 and 57%, and 100 and 74% for ASiR 40%, ASiR 100%, and MBIR, respectively. Conclusion MBIR offers substantial noise reduction with increased SNR, paving the way for implementation of submillisievert CCTA protocols in clinical routine. In contrast, inferior noise reduction by ASiR negatively affects diagnostic accuracy of submillisievert CCTA for CAD detection.


British Journal of Radiology | 2017

A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol

Dominik C. Benz; Christoph Gräni; Beatrice Hirt Moch; Fran Mikulicic; Jan Vontobel; Tobias A. Fuchs; Julia Stehli; Olivier F. Clerc; Mathias Possner; Aju P. Pazhenkottil; Oliver Gaemperli; Ronny R. Buechel; Philipp A. Kaufmann

OBJECTIVE To evaluate the impact of a low-dose (LD) and an ultra-LD (ULD) contrast protocol for coronary CT angiography on qualitative and quantitative image parameters in a clinical setting. METHODS We scanned 120 consecutive patients with a 256-slice CT scanner applying a LD (60 patients, 35-55 ml) or ULD (60 patients, 25-45 ml) contrast protocol adapted to the body mass index. Visually assessed image quality and attenuation measured in each coronary segment were retrospectively compared in 20 consecutive patients scanned with a normal-dose (ND, 40-105 ml) contrast protocol. RESULTS Visually assessed image quality did not differ significantly among protocols. By contrast, attenuation obtained from the ULD protocol (median contrast volume 35 ml) differed significantly from the LD (median 45 ml) and ND (median 70 ml) protocols in the coronary segments (316 ± 52 vs 363 ± 60 and 359 ± 52 HU, p < 0.001). Attenuation did not differ significantly between the LD and ND protocol. The proportion of patients with inadequate coronary vessel attenuation was significantly higher (p < 0.001) in the ULD protocol (37%) than in the ND (5%) and LD (10%) protocols but did not differ significantly between the ND and LD protocols. CONCLUSION In a clinical setting, a LD contrast protocol with a median volume of 45 ml is feasible for the latest generation 256-slice coronary CT angiography as it yields attenuation comparable to a ND protocol. By contrast, the implementation of an ULD protocol remains challenging. Advances in knowledge: Although not perceived by the naked eye, an ULD contrast protocol in a clinical setting yields attenuation below a threshold for diagnostic image quality.


European Journal of Echocardiography | 2016

Quantification of epicardial and intrathoracic fat volume does not provide an added prognostic value as an adjunct to coronary artery calcium score and myocardial perfusion single-photon emission computed tomography

Mathias Possner; Riccardo Liga; Thomas Gaisl; Jan Vontobel; Olivier F. Clerc; Fran Mikulicic; Dominik C. Benz; Christoph Gräni; Julia Stehli; Tobias A. Fuchs; Damini Dey; Aju P. Pazhenkottil; Bernhard A. Herzog; Oliver Gaemperli; Ronny R. Buechel; Philipp A. Kaufmann

AIMS To compare the predictive value of epicardial and intrathoracic fat volume (EFV, IFV), coronary artery calcium (CAC) score, and single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) for major adverse cardiac events (MACE). METHODS AND RESULTS Follow-up was obtained in 275 patients with known or suspected coronary artery disease (CAD), who underwent SPECT-MPI including non-contrast cardiac computed tomography (CT) for attenuation correction to evaluate ischaemic heart disease and in whom EFV, IFV, and CAC score were calculated from non-contrast CT. Associations between fat volume, traditional cardiovascular risk factors, CAC score, and SPECT-MPI results were assessed and MACE predictors identified by Cox proportional hazard regression and global χ(2) statistics. After a median follow-up of 2.9 years, MACE were recorded in 38 patients. In univariate Cox regression analysis, EFV and IFV were predictors of MACE (P = 0.013 and P = 0.004, respectively). In multivariate analysis, EFV and IFV provided incremental predictive value beyond traditional cardiovascular risk factors (P < 0.05 and P < 0.01). However, after adjustment for CAC score and SPECT-MPI results, EFV and IFV fell short of statistical significance as independent outcome predictors. CONCLUSION Quantification of EFV and IFV is associated with MACE and may improve risk stratification beyond traditional cardiovascular risk factors. However, once CAC score and/or SPECT-MPI results are known, EFV and IFV do not provide any added clinically relevant prognostic value. Further studies may identify the subpopulation with the largest relative merit of EFV and IFV as an adjunct to SPECT-MPI and CAC score.

Collaboration


Dive into the Fran Mikulicic's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge