Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Dotse Selali Chormey is active.

Publication


Featured researches published by Dotse Selali Chormey.


Analytical Letters | 2016

Determination of Lead in Drinking and Wastewater by Hydride Generation Atomic Absorption Spectrometry

Sezgin Bakırdere; Dotse Selali Chormey; Çağdaş Büyükpınar; Nevim San; Seyfullah Keyf

ABSTRACT This work describes the optimization of hydride generation atomic absorption spectrometry for the determination of lead at trace concentrations. The parameters affecting the production, transport, and atomization of plumbane in a closed vessel were optimized. The concentrations of reagents affecting the generation of the lead hydride were also optimized to obtain high hydride generation efficiency. The atomization temperature, reaction period, pump speed, pump period, and flow rates of reducing agent and carrier gas were varied to maximize the sensitivity for lead. The accuracy of the method was evaluated by the analysis of certified reference materials. The method provided a linear dynamic range for lead from 2.0 to 40 µg/L with a limit of detection of 0.56 µg/L.


Analytical Methods | 2016

Development of a sensitive liquid–liquid extraction method for the determination of N-butyryl-L-homoserine lactone produced in a submerged membrane bioreactor by gas chromatography mass spectrometry and deuterated anthracene as the internal standard

Nouha Bakaraki; Dotse Selali Chormey; Sezgin Bakırdere; Guleda Onkal Engin

Quorum sensing is defined as the bacterial communication through sending and receiving chemical signals such as N-acyl homoserine lactone (AHL) and oligopeptide for Gram negative bacteria and Gram positive bacteria, respectively. This mysterious bacterial interaction regulates a wide range of activities affecting the environment, agriculture, and therefore, humans. In the last century, quorum sensing investigations trying to follow and measure these chemical signals have accelerated. In this study, an analytical method was developed and optimized in order to extract and measure one of the AHLs: N-butyryl-L-homoserine lactone (C4-HSL) by gas chromatography-mass spectrometry (GC-MS). The aim of the study was to develop a method that increases the sensitivity and precision of AHL detection by GC-MS due to the problem in the determination of analytes in wastewater which have a complex matrix. The limits of detection and quantification obtained for C4-HSL were 12.9 ng mL−1 and 43.3 ng mL−1, respectively. The precision of the method was improved upon using deuterated anthracene as the internal standard, which gave a lower relative standard deviation compared to that without the internal standard.


International Journal of Environmental Analytical Chemistry | 2017

Arsenic speciation in water and biota samples at trace levels by ion chromatography inductively coupled plasma-mass spectrometry

Merve Fırat; Sezgin Bakırdere; Sabriye Sel; Dotse Selali Chormey; Ömer Elkıran; Fatih Erulaş; Fatma Turak

ABSTRACT A sensitive, reliable, simple and rapid analytical method was developed for the determination of arsenite [As(III)], arsenate [As(V)] and arsenobetaine (AsB) species using ion chromatography combined with inductively coupled plasma-mass spectrometry (IC-ICP-MS). Inorganic and organic arsenic species were separated with an anion exchange column (Dionex AS9) and a 50 mM sodium bicarbonate mobile phase (pH 10) at a flow rate of 1.0 mL min−1. %RSD values were found to be lower than 5.1% for all arsenic species. The limits of detection (LOD) obtained for As(III), As(V) and AsB were 16.5 ng L−1, 14.1 ng L−1 and 6.2 ng L−1, respectively. The developed analytical method was tested using AsB certified reference material (NMIJ CRM 7901-a), and spring water certified reference material (UME CRM 1201) for accuracy check. This method was applied for the quantitative determination of arsenic species in different water samples and chicken samples as a solid matrix.


Pure and Applied Chemistry | 2018

Accurate determination of pesticides, hormones and endocrine disruptor compounds in complex environmental samples using matrix dilution and matrix matching with dispersive liquid–liquid microextraction

Dotse Selali Chormey; Merve Fırat; Çağdaş Büyükpınar; Fatih Erulaş; Okan Tarık Komesli; Fatma Turak; Sezgin Bakırdere

Abstract Quantitative determination of contaminants in environmental samples is usually hampered by low analyte recovery which results from the complex nature of the sample matrix. This study presents the application of a developed dispersive liquid–liquid microextraction method for the determination of 12 analytes in environmental samples including sea water, fresh water (lake, well and tap water), brackish water and soil samples. Matrix matched standards were used to compensate for the low analyte recovery recorded by the conventional calibration method. The effect of matrix dilution on analyte recovery was also tested. All matrix matched and matrix diluted spiked recoveries were done concurrently with calibration standards prepared in deionized water. Percent recoveries recorded for the analytes according to deionized water calibration standards ranged between 66 and 137%. Matrix matching and matrix dilution yielded close to 100% recovery results, but the later lowered the detection limit according to the dilution factor.


Instrumentation Science & Technology | 2018

Development of a sensitive closed batch vessel hydride generation atomic absorption spectrometry method for the determination of cadmium in aqueous samples

Çağdaş Büyükpınar; Büşra Bekar; Esra Maltepe; Dotse Selali Chormey; Fatma Turak; Nevin San; Sezgin Bakırdere

ABSTRACT Hydride generation atomic absorption spectrometry was used as a simple, sensitive, and economical method for the determination of cadmium at trace levels. This study includes a stepwise optimization of all parameters that have an impact on the production, transport, and atomization of cadmium hydride for rapid determination due to the unstable nature of the hydride produced. The cell temperature for atomization, pump period, and flow rate of carrier gas were varied, and the best conditions were defined to obtain lower detection limits. In addition, the acid and sodium borohydride concentrations were optimized since they directly affect the production of the cadmium hydride. Under optimum experimental conditions, the hydride generation efficiency was greatly enhanced to record optimized analytical signals. The accuracy of the method was determined by the analysis of a certified reference material, and the results were in good agreement with the certified value. A linear dynamic range for cadmium was observed from 0.10 to 2.0 µg/L. High sensitivity was obtained with a limit of detection of 0.029 µg/L.


Analytical Letters | 2018

Determination of Bismuth in Bottled and Mineral Water Samples at Trace Levels by T-Shaped Slotted Quartz Tube – Atom Trapping – Flame Atomic Absorption Spectrometry

Süleyman Bodur; Sezin Erarpat; Dotse Selali Chormey; Çağdaş Büyükpınar; Sezgin Bakırdere

Abstract An accurate and reliable analytical method for the determination of bismuth at trace levels in bottled and mineral water samples has been developed based on hydrogen assisted T-shape slotted quartz tube-atom trap-flame atomic absorption spectrometry (T-SQT-AT-FAAS). Conventional FAAS is not sufficiently sensitive to measure trace and ultra-trace levels of metals due to the low nebulization efficiency and short residence time of atoms in the light path. To overcome this problem, atom trapping with a T-shaped slotted quartz tube was coupled to the FAAS system. Bismuth atoms were trapped on the surface of T-SQT and released by hydrogen gas, which provided a reducing environment. All of the system parameters such as flame type, hydrogen flow rate, the height of T-SQT from the burner head, and trapping period were optimized to enhance the analytical signal to attain low detection limits. After obtaining the optimum conditions, the limit of detection and limit of quantitation of the developed method were found to be 0.95 and 3.2 µg L−1, respectively. Recovery values were obtained between 90% and 104% that showed good accuracy and applicability of the proposed method to the analysis of bottled and mineral water samples.


Spectrochimica Acta Part B: Atomic Spectroscopy | 2017

Determination of trace amount of cadmium using dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry

Merve Fırat; Sezgin Bakırdere; Maral Selin Fındıkoğlu; Emine Betül Kafa; Elif Yazıcı; Melda Yolcu; Çağdaş Büyükpınar; Dotse Selali Chormey; Sabriye Sel; Fatma Turak


Trends in Analytical Chemistry | 2017

Quorum sensing: Little talks for an effective bacterial coordination

Nouha Bakaraki Turan; Dotse Selali Chormey; Çağdaş Büyükpınar; Guleda Onkal Engin; Sezgin Bakırdere


Microchemical Journal | 2017

Sensitive determination of copper in water samples using dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry

Gözde Özzeybek; Sezin Erarpat; Dotse Selali Chormey; Merve Fırat; Çağdaş Büyükpınar; Fatma Turak; Sezgin Bakırdere


Microchemical Journal | 2017

Determination of cadmium at ultratrace levels by dispersive liquid-liquid microextraction and batch type hydride generation atomic absorption spectrometry

Nursu Aylin Kasa; Dotse Selali Chormey; Çağdaş Büyükpınar; Fatma Turak; Türkan Börklü Budak; Sezgin Bakırdere

Collaboration


Dive into the Dotse Selali Chormey's collaboration.

Top Co-Authors

Avatar

Sezgin Bakırdere

Yıldız Technical University

View shared research outputs
Top Co-Authors

Avatar

Fatma Turak

Yıldız Technical University

View shared research outputs
Top Co-Authors

Avatar

Merve Fırat

Yıldız Technical University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sezin Erarpat

Yıldız Technical University

View shared research outputs
Top Co-Authors

Avatar

Gözde Özzeybek

Yıldız Technical University

View shared research outputs
Top Co-Authors

Avatar

Süleyman Bodur

Yıldız Technical University

View shared research outputs
Top Co-Authors

Avatar

Sabriye Sel

Yıldız Technical University

View shared research outputs
Top Co-Authors

Avatar

Elif Öztürk Er

Yıldız Technical University

View shared research outputs
Top Co-Authors

Avatar

Emine Betül Kafa

Yıldız Technical University

View shared research outputs
Researchain Logo
Decentralizing Knowledge