Merve Fırat
Yıldız Technical University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Merve Fırat.
International Journal of Environmental Analytical Chemistry | 2017
Merve Fırat; Sezgin Bakırdere; Sabriye Sel; Dotse Selali Chormey; Ömer Elkıran; Fatih Erulaş; Fatma Turak
ABSTRACT A sensitive, reliable, simple and rapid analytical method was developed for the determination of arsenite [As(III)], arsenate [As(V)] and arsenobetaine (AsB) species using ion chromatography combined with inductively coupled plasma-mass spectrometry (IC-ICP-MS). Inorganic and organic arsenic species were separated with an anion exchange column (Dionex AS9) and a 50 mM sodium bicarbonate mobile phase (pH 10) at a flow rate of 1.0 mL min−1. %RSD values were found to be lower than 5.1% for all arsenic species. The limits of detection (LOD) obtained for As(III), As(V) and AsB were 16.5 ng L−1, 14.1 ng L−1 and 6.2 ng L−1, respectively. The developed analytical method was tested using AsB certified reference material (NMIJ CRM 7901-a), and spring water certified reference material (UME CRM 1201) for accuracy check. This method was applied for the quantitative determination of arsenic species in different water samples and chicken samples as a solid matrix.
Pure and Applied Chemistry | 2018
Dotse Selali Chormey; Merve Fırat; Çağdaş Büyükpınar; Fatih Erulaş; Okan Tarık Komesli; Fatma Turak; Sezgin Bakırdere
Abstract Quantitative determination of contaminants in environmental samples is usually hampered by low analyte recovery which results from the complex nature of the sample matrix. This study presents the application of a developed dispersive liquid–liquid microextraction method for the determination of 12 analytes in environmental samples including sea water, fresh water (lake, well and tap water), brackish water and soil samples. Matrix matched standards were used to compensate for the low analyte recovery recorded by the conventional calibration method. The effect of matrix dilution on analyte recovery was also tested. All matrix matched and matrix diluted spiked recoveries were done concurrently with calibration standards prepared in deionized water. Percent recoveries recorded for the analytes according to deionized water calibration standards ranged between 66 and 137%. Matrix matching and matrix dilution yielded close to 100% recovery results, but the later lowered the detection limit according to the dilution factor.
Spectrochimica Acta Part B: Atomic Spectroscopy | 2017
Merve Fırat; Sezgin Bakırdere; Maral Selin Fındıkoğlu; Emine Betül Kafa; Elif Yazıcı; Melda Yolcu; Çağdaş Büyükpınar; Dotse Selali Chormey; Sabriye Sel; Fatma Turak
Microchemical Journal | 2017
Gözde Özzeybek; Sezin Erarpat; Dotse Selali Chormey; Merve Fırat; Çağdaş Büyükpınar; Fatma Turak; Sezgin Bakırdere
Water Air and Soil Pollution | 2018
Maral Selin Fındıkoğlu; Merve Fırat; Dotse Selali Chormey; Fatma Turak; Çiğdem Şahin; Sezgin Bakırdere
Environmental Monitoring and Assessment | 2018
Merve Fırat; Süleyman Bodur; Büşra Tışlı; Cansu Özlü; Dotse Selali Chormey; Fatma Turak; Sezgin Bakırdere
Bulletin of Environmental Contamination and Toxicology | 2018
Şükran Melda Yolcu; Merve Fırat; Dotse Selali Chormey; Çağdaş Büyükpınar; Fatma Turak; Sezgin Bakırdere
Microchemical Journal | 2019
Betül Çiçek Özkan; Merve Fırat; Dotse Selali Chormey; Sezgin Bakırdere
Water Air and Soil Pollution | 2018
Dotse Selali Chormey; Merve Fırat; Sezgin Bakırdere
Measurement | 2018
Emine Betül Kafa; Merve Fırat; Dotse Selali Chormey; Fatma Turak; Sezgin Bakırdere