IEEE Transactions on Medical Imaging | 2015
Mohammad Mehrmohammadi; Pengfei Song; Duane D. Meixner; Robert T. Fazzio; Shigao Chen; James F. Greenleaf; Mostafa Fatemi; Azra Alizad
In clinical practice, an overwhelming majority of biopsied thyroid nodules are benign. Therefore, there is a need for a complementary and noninvasive imaging tool to provide clinically relevant diagnostic information about thyroid nodules to reduce the rate of unnecessary biopsies. The goal of this study was to evaluate the feasibility of utilizing comb-push ultrasound shear elastography (CUSE) to measure the mechanical properties (i.e., stiffness) of thyroid nodules and use this information to help classify nodules as benign or malignant. CUSE is a fast and robust 2-D shear elastography technique in which multiple laterally distributed acoustic radiation force beams are utilized simultaneously to produce shear waves. Unlike other shear elasticity imaging modalities, CUSE does not suffer from limited field of view (FOV) due to shear wave attenuation and can provide a large FOV at high frame rates. To evaluate the utility of CUSE in thyroid imaging, a preliminary study was performed on a group of five healthy volunteers and 10 patients with ultrasound-detected thyroid nodules prior to fine needle aspiration biopsy. The measured shear wave speeds in normal thyroid tissue and thyroid nodules were converted to Youngs modulus (E), indicating a measure of tissue stiffness. Our results indicate an increase in E for thyroid nodules compared to normal thyroid tissue. This increase was significantly higher in malignant nodules compared to benign. The Youngs modulus in normal thyroid tissue, benign and malignant nodules were found to be 23.2 ±8.29 kPa, 91.2±34.8 kPa, and 173.0±17.1 kPa, respectively. Results of this study suggest the utility of CUSE in differentiating between benign and malignant thyroid nodules.
IEEE Transactions on Medical Imaging | 2014
Heng Zhao; Pengfei Song; Duane D. Meixner; Randall R. Kinnick; Matthew R. Callstrom; William Sanchez; Matthew W. Urban; Armando Manduca; James F. Greenleaf; Shigao Chen
Shear wave speed can be used to assess tissue elasticity, which is associated with tissue health. Ultrasound shear wave elastography techniques based on measuring the propagation speed of the shear waves induced by acoustic radiation force are becoming promising alternatives to biopsy in liver fibrosis staging. However, shear waves generated by such methods are typically very weak. Therefore, the penetration may become problematic, especially for overweight or obese patients. In this study, we developed a new method called external vibration multi-directional ultrasound shearwave elastography (EVMUSE), in which external vibration from a loudspeaker was used to generate a multi-directional shear wave field. A directional filter was then applied to separate the complex shear wave field into several shear wave fields propagating in different directions. A 2-D shear wave speed map was reconstructed from each individual shear wave field, and a final 2-D shear wave speed map was constructed by compounding these individual wave speed maps. The method was validated using two homogeneous phantoms and one multi-purpose tissue-mimicking phantom. Ten patients undergoing liver magnetic resonance elastography (MRE) were also studied with EVMUSE to compare results between the two methods. Phantom results showed EVMUSE was able to quantify tissue elasticity accurately with good penetration. In vivo EVMUSE results were well correlated with MRE results, indicating the promise of using EVMUSE for liver fibrosis staging.
PLOS ONE | 2015
Max Denis; Mohammad Mehrmohammadi; Pengfei Song; Duane D. Meixner; Robert T. Fazzio; Sandhya Pruthi; Dana H. Whaley; Shigao Chen; Mostafa Fatemi; Azra Alizad
Purpose or Objective To evaluate the performance of Comb-push Ultrasound Shear Elastography (CUSE) for classification of breast masses. Materials and Methods CUSE is an ultrasound-based quantitative two-dimensional shear wave elasticity imaging technique, which utilizes multiple laterally distributed acoustic radiation force (ARF) beams to simultaneously excite the tissue and induce shear waves. Female patients who were categorized as having suspicious breast masses underwent CUSE evaluations prior to biopsy. An elasticity estimate within the breast mass was obtained from the CUSE shear wave speed map. Elasticity estimates of various types of benign and malignant masses were compared with biopsy results. Results Fifty-four female patients with suspicious breast masses from our ongoing study are presented. Our cohort included 31 malignant and 23 benign breast masses. Our results indicate that the mean shear wave speed was significantly higher in malignant masses (6 ± 1.58 m/s) in comparison to benign masses (3.65 ± 1.36 m/s). Therefore, the stiffness of the mass quantified by the Young’s modulus is significantly higher in malignant masses. According to the receiver operating characteristic curve (ROC), the optimal cut-off value of 83 kPa yields 87.10% sensitivity, 82.61% specificity, and 0.88 for the area under the curve (AUC). Conclusion CUSE has the potential for clinical utility as a quantitative diagnostic imaging tool adjunct to B-mode ultrasound for differentiation of malignant and benign breast masses.
Journal of Pediatric Gastroenterology and Nutrition | 2009
Mhd Louai Manini; Duane Burton; Duane D. Meixner; Deborah J. Eckert; Matthew R. Callstrom; Grant D. Schmit; Mounif El-Youssef; Michael Camilleri
Objectives:Abnormal gastric accommodation to a meal results in dyspepsia. Current methods to measure gastric volume (GV) are invasive or involve ionizing radiation. The aims of this study were to compare fasting and postprandial (PP) GVs measured by 99mTc-single photon emission computed tomography (SPECT) and 3-dimensional ultrasound (3D-US) in adults, to assess the performance characteristics of 3D-US measurement of GV during fasting and postprandially, and to develop normative data of GVs in 24 healthy adolescents. Patients and Methods:Eleven adults underwent SPECT and 3D-US simultaneously to measure GV, and a second 3D-US alone within 1 week of the first study. Twenty-four adolescents underwent 1 3D-US measurement. Each study included fasting, a 300-mL Ensure meal, and 0 to 30-minute PP GV measurements. Results:3D-US identifies GV accommodation to 300 mL Ensure. Delta (0–30 minutes average PP fasting) GV was 444 mL (median, interquartile range [IQR] = 422, 534) for 3D-US and 543 mL (median, IQR = 486, 564) for SPECT (P = 0.15). There were larger interindividual coefficients of variation for GV by 3D-US (60.3% fasting and 21.3% average PP) compared with 19% fasting and 9.2% PP for SPECT. Intraindividual coefficients of variation for the 2 3D-US measurements in adults were 84% fasting and 44% average PP. The estimated GVs for the adolescent group (median [25th–75th IQR]) were 33 (18–53) mL fasting, 330 (284–357) mL 30 minutes PP, and 281 (240–324) mL for delta GV. Conclusions:3D-US is a promising method to measure GV accommodation to a meal. Large coefficients of variation reflect the learning stage in development of this promising technique.
Journal of Ultrasound in Medicine | 2014
Heng Zhao; Jun Chen; Duane D. Meixner; Hua Xie; Vijay Shamdasani; Shiwei Zhou; Jean Luc Robert; Matthew W. Urban; William Sanchez; Matthew R. Callstrom; Richard L. Ehman; James F. Greenleaf; Shigao Chen
Magnetic resonance elastography (MRE) has excellent performance in detecting liver fibrosis and is becoming an alternative to liver biopsy in clinical practice. Ultrasound techniques based on measuring the propagation speed of the shear waves induced by acoustic radiation force also have shown promising results for liver fibrosis staging. The objective of this study was to compare ultrasound‐based shear wave measurement to MRE.
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control | 2017
Xiaoming Zhang; Thomas Osborn; Boran Zhou; Duane D. Meixner; Randall R. Kinnick; Brian J. Bartholmai; James F. Greenleaf; Sanjay Kalra
A lung ultrasound surface wave elastography (LUSWE) technique is developed to measure superficial lung tissue elastic properties. The purpose of this paper was to translate LUSWE into clinical studies for assessing patients with interstitial lung disease (ILD) and present the pilot data from lung measurements on 10 healthy subjects and 10 patients with ILD. ILD includes multiple lung disorders in which the lung tissue is distorted and stiffened by tissue fibrosis. Chest radiography and computed tomography are the most commonly used techniques for assessing lung disease, but they are associated with radiation and cannot directly measure lung elastic properties. LUSWE provides a noninvasive and nonionizing technique to measure the elastic properties of superficial lung tissue. LUSWE was used to measure regions of both lungs through six intercostal spaces for patients and healthy subjects. The data are presented as wave speed at 100, 150, and 200 Hz at the six intercostal spaces. As an example, the surface wave speeds are, respectively, 1.88 ± 0.11 m/s at 100 Hz, 2.74 ± 0.26 m/s at 150 Hz, and 3.62 ± 0.13 m/s at 200 Hz for a healthy subject in the upper right lung; this is in comparison to measurements from an ILD patient of 3.3 ± 0.37 m/s at 100 Hz, 4.38 ± 0.33 m/s at 150 Hz, and 5.24 ± 0.44 m/s at 200 Hz in the same lung space. Significant differences in wave speed between healthy subjects and ILD patients were found. LUSWE is a safe and noninvasive technique which may be useful for assessing ILD.
Journal of Ultrasound in Medicine | 2016
Pengfei Song; Daniel C. Mellema; Shannon P. Sheedy; Duane D. Meixner; Ryan M. Karshen; Matthew W. Urban; Armando Manduca; William Sanchez; Matthew R. Callstrom; James F. Greenleaf; Shigao Chen
To investigate the correlation between 2‐dimensional (2D) ultrasound shear wave elastography (SWE) and magnetic resonance elastography (MRE) in liver stiffness measurement and the diagnostic performance of 2D SWE for liver fibrosis when imaging from different intercostal spaces and using MRE as the reference standard.
PLOS ONE | 2017
Mahdi Bayat; Max Denis; Adriana Gregory; Mohammad Mehrmohammadi; Viksit Kumar; Duane D. Meixner; Robert T. Fazzio; Mostafa Fatemi; Azra Alizad
Background Lesion stiffness measured by shear wave elastography has shown to effectively separate benign from malignant breast masses. The aim of this study was to evaluate different aspects of Comb-push Ultrasound Shear Elastography (CUSE) performance in differentiating breast masses. Methods With written signed informed consent, this HIPAA- compliant, IRB approved prospective study included patients from April 2014 through August 2016 with breast masses identified on conventional imaging. Data from 223 patients (19–85 years, mean 59.93±14.96 years) with 227 suspicious breast masses identifiable by ultrasound (mean size 1.83±2.45cm) were analyzed. CUSE was performed on all patients. Three regions of interest (ROI), 3 mm in diameter each, were selected inside the lesion on the B-mode ultrasound which also appeared in the corresponding shear wave map. Lesion elasticity values were measured in terms of the Young’s modulus. In correlation to pathology results, statistical analyses were performed. Results Pathology revealed 108 lesions as malignant and 115 lesions as benign. Additionally, 4 lesions (BI-RADS 2 and 3) were considered benign and were not biopsied. Average lesion stiffness measured by CUSE resulted in 84.26% sensitivity (91 of 108), 89.92% specificity (107 of 119), 85.6% positive predictive value, 89% negative predictive value and 0.91 area under the curve (P<0.0001). Stiffness maps showed spatial continuity such that maximum and average elasticity did not have significantly different results (P > 0.21). Conclusion CUSE was able to distinguish between benign and malignant breast masses with high sensitivity and specificity. Continuity of stiffness maps allowed for choosing multiple quantification ROIs which covered large areas of lesions and resulted in similar diagnostic performance based on average and maximum elasticity. The overall results of this study, highlights the clinical value of CUSE in differentiation of breast masses based on their stiffness.
Ultrasound in Medicine and Biology | 2016
Carolina Amador; Pengfei Song; Duane D. Meixner; Shigao Chen; Matthew W. Urban
Quantification of liver elasticity is a major application of shear wave elasticity imaging (SWEI) to non-invasive assessment of liver fibrosis stages. SWEI measurements can be highly affected by ultrasound image quality. Ultrasound harmonic imaging has exhibited a significant improvement in ultrasound image quality as well as for SWEI measurements. This was previously illustrated in cardiac SWEI. The purpose of this study was to evaluate liver shear wave particle displacement detection and shear wave velocity (SWV) measurements with fundamental and filter-based harmonic ultrasound imaging. In a cohort of 17 patients with no history of liver disease, a 2.9-fold increase in maximum shear wave displacement, a 0.11 m/s decrease in the overall interquartile range and median SWV and a 17.6% increase in the success rate of SWV measurements were obtained when filter-based harmonic imaging was used instead of fundamental imaging.
Academic Radiology | 2018
Adriana Gregory; Mahdi Bayat; Viksit Kumar; Max Denis; Bae Hyung Kim; Jeremy Webb; Duane D. Meixner; Mabel Ryder; John M. Knudsen; Shigao Chen; Mostafa Fatemi; Azra Alizad
RATIONALE AND OBJECTIVES Low specificity of traditional ultrasound in differentiating benign from malignant thyroid nodules leads to a great number of unnecessary (ie, benign) fine-needle aspiration biopsies that causes a significant financial and physical burden to the patients. Ultrasound shear wave elastography is a technology capable of providing additional information related to the stiffness of tissues. In this study, quantitative stiffness values acquired by ultrasound shear wave elastography in two different imaging planes were evaluated for the prediction of malignancy in thyroid nodules. In addition, the association of elasticity measurements with sonographic characteristics of thyroid gland and nodules is presented. MATERIALS AND METHODS A total number of 155 patients (106 female and 49 male) (average age 57.48 ± 14.44 years) with 173 thyroid nodules (average size 24.89 ± 15.41 mm, range 5-68 mm) scheduled for fine-needle aspiration biopsy were recruited from March 2015 to May 2017. Comb-push shear elastography imaging was performed at longitudinal and transverse anatomic planes. Mean (Emean) and maximum (Emax) elasticity values were obtained. RESULTS Measurements at longitudinal view were statistically significantly higher than measurements at transverse view. Nodules with calcifications were associated with increased elasticity, and nodules with a vascular component or within an enlarged thyroid gland (goiter) were associated with a lower elasticity value. Receiver operating characteristic curve analysis was performed for Emean and Emax at each imaging plane and for the average of both planes. Sensitivity of 95.45%, specificity of 86.61%, 0.58 positive predictive value, and 0.99 negative predictive value were achieved by the average of the two planes for each Emean and Emax parameters, with area under the curve of 92% and 93%, and a cutoff value of 49.09 kPa and 105.61 kPa, respectively. CONCLUSIONS The elastic properties of thyroid nodules showed promise to be a good discriminator between malignant and benign nodules (P < .0001). However, probe orientation and internal features such as calcifications, vascular component, and goiter may influence the final elastography measurements. A larger number of malignant nodules need to be studied to further validate our results.