Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where E. Testa is active.

Publication


Featured researches published by E. Testa.


Applied Physics Letters | 2008

Monitoring the Bragg peak location of 73MeV∕u carbon ions by means of prompt γ-ray measurements

E. Testa; M. Bajard; M. Chevallier; D. Dauvergne; F. Le Foulher; N. Freud; J.M. Létang; J.-C. Poizat; C. Ray; M. Testa

By means of a time-of-flight technique, we measured the longitudinal profile of prompt γ-rays emitted by 73MeV∕u C13 ions irradiating a polymethyl methacrylate target. This technique allowed us to minimize the shielding against neutrons and scattered γ-rays, and to correlate prompt gamma emission to the ion path. This correlation, together with a high counting rate, paves the way toward real-time monitoring of the longitudinal dose profile during ion therapy treatments. Moreover, the time correlation between the prompt gamma detection and the transverse position of the incident ions measured by a beam monitor can provide real-time three dimensional control of the irradiation.


Physics in Medicine and Biology | 2013

Distributions of secondary particles in proton and carbon-ion therapy: a comparison between GATE/Geant4 and FLUKA Monte Carlo codes

Charlotte Robert; George Dedes; G. Battistoni; T.T. Böhlen; Irène Buvat; F. Cerutti; M P W Chin; A. Ferrari; Pierre Gueth; Christopher Kurz; Loïc Lestand; A. Mairani; G. Montarou; R Nicolini; Pablo G. Ortega; Katia Parodi; Y Prezado; P. Sala; David Sarrut; E. Testa

Monte Carlo simulations play a crucial role for in-vivo treatment monitoring based on PET and prompt gamma imaging in proton and carbon-ion therapies. The accuracy of the nuclear fragmentation models implemented in these codes might affect the quality of the treatment verification. In this paper, we investigate the nuclear models implemented in GATE/Geant4 and FLUKA by comparing the angular and energy distributions of secondary particles exiting a homogeneous target of PMMA. Comparison results were restricted to fragmentation of (16)O and (12)C. Despite the very simple target and set-up, substantial discrepancies were observed between the two codes. For instance, the number of high energy (>1 MeV) prompt gammas exiting the target was about twice as large with GATE/Geant4 than with FLUKA both for proton and carbon ion beams. Such differences were not observed for the predicted annihilation photon production yields, for which ratios of 1.09 and 1.20 were obtained between GATE and FLUKA for the proton beam and the carbon ion beam, respectively. For neutrons and protons, discrepancies from 14% (exiting protons-carbon ion beam) to 57% (exiting neutrons-proton beam) have been identified in production yields as well as in the energy spectra for neutrons.


IEEE Transactions on Nuclear Science | 2011

Design Guidelines for a Double Scattering Compton Camera for Prompt-

M.-H. Richard; M. Chevallier; D. Dauvergne; N. Freud; P. Henriquet; F. Le Foulher; J.M. Létang; G. Montarou; C. Ray; F. Roellinghoff; E. Testa; M. Testa; A.H. Walenta

In hadrontherapy in order to fully take advantage of the assets of the ion irradiation, the position of the Bragg peak has to be monitored accurately. Here, we investigate a monitoring method relying on the detection in real time of the prompt γ emitted quasi instantaneously during the nuclear fragmentation processes. Our detection system combines a beam hodoscope and a double scattering Compton camera. The prompt-γ emission points are reconstructed by intersecting the ion trajectories given by the hodoscope and the Compton cones reconstructed with the camera. We propose here to study in terms of point spread function and efficiency the theoretical feasibility of the emission points reconstruction with our set-up in the case of a photon point source in air. First we analyze the nature of all the interactions which are likely to produce an energy deposit in the three detectors of the camera. It is underlined that upper energy thresholds in both scatter detectors are required in order to select mainly Compton events (one Compton interaction in each scatter detector and one interaction in the absorber detector). Then, we study the influence of various parameters such as the photon energy and the inter-detector distances on the Compton camera response. These studies are carried out by means of Geant4 simulations. We use a source with a spectrum corresponding to the prompt-γ spectrum emitted during the carbon ion irradiation of a water phantom. In the current configuration, the spatial resolution of the Compton camera is about 6 mm (Full Width at Half Maximum) and the detection efficiency 10-5. Finally, provided the detection efficiency is increased, the clinical applicability of our system is considered.


Physics in Medicine and Biology | 2014

\gamma

F. Roellinghoff; A. Benilov; D. Dauvergne; George Dedes; N. Freud; Guillaume Janssens; J. Krimmer; J.M. Létang; M. Pinto; D. Prieels; C. Ray; J. Smeets; Frédéric Stichelbaut; E. Testa

Prompt-gamma profile was measured at WPE-Essen using 160 MeV protons impinging a movable PMMA target. A single collimated detector was used with time-of-flight (TOF) to reduce the background due to neutrons. The target entrance rise and the Bragg peak falloff retrieval precision was determined as a function of incident proton number by a fitting procedure using independent data sets. Assuming improved sensitivity of this camera design by using a greater number of detectors, retrieval precisions of 1 to 2 mm (rms) are expected for a clinical pencil beam. TOF improves the contrast-to-noise ratio and the performance of the method significantly.


Physics in Medicine and Biology | 2014

Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study

G. Dedes; M. Pinto; D. Dauvergne; N. Freud; J. Krimmer; J.M. Létang; C. Ray; E. Testa

Monte Carlo simulations are nowadays essential tools for a wide range of research topics in the field of radiotherapy. They also play an important role in the effort to develop a real-time monitoring system for quality assurance in proton and carbon ion therapy, by means of prompt-gamma detection. The internal theoretical nuclear models of Monte Carlo simulation toolkits are of decisive importance for the accurate description of neutral or charged particle emission, produced by nuclear interactions between beam particles and target nuclei. We assess the performance of Geant4 nuclear models in the context of prompt-gamma emission, comparing them with experimental data from proton and carbon ion beams. As has been shown in the past and further indicated in our study, the prompt-gamma yields are consistently overestimated by Geant4 by a factor of about 100% to 200% over an energy range from 80 to 310 MeV/u for the case of (12)C, and to a lesser extent for 160 MeV protons. Furthermore, we focus on the quantum molecular dynamics (QMD) modeling of ion-ion collisions, in order to optimize its description of light nuclei, which are abundant in the human body and mainly anticipated in hadrontherapy applications. The optimization has been performed by benchmarking QMD free parameters with well established nuclear properties. In addition, we study the effect of this optimization on charged particle emission. With the usage of the proposed parameter values, discrepancies reduce to less than 70%, with the highest values being attributed to the nucleon-ion induced prompt-gammas. This conclusion, also confirmed by the disagreement we observe in the case of proton beams, indicates the need for further investigation on nuclear models which describe proton and neutron induced nuclear reactions.


ieee nuclear science symposium | 2009

Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera

M.-H. Richard; M. Chevallier; D. Dauvergne; N. Freud; P. Henriquet; F. Le Foulher; J.M. Létang; G. Montarou; C. Ray; F. Roellinghoff; E. Testa; M. Testa; A.H. Walenta

In hadron therapy in order to fully take advantage of the assets of the ion irradiation, the position of the Bragg peak has to be monitored accurately. Here, we propose a monitoring method relying on the detection in real time of the prompt γ emitted quasi instantaneously during the nuclear fragmentation processes. Our detection system combines a beam hodoscope and a double scattering Compton camera. The prompt γ emission points are reconstructed by intersecting the ion trajectories given by the hodoscope and the Compton cones reconstructed with the camera. We studied the influence of various parameters such as the photon energy and the inter-detector distances on the Compton camera response to a photon point source. This study was carried out by means of Geant4 simulations. In the current configuration, for a photon source with a typical prompt γ spectrum, the spatial resolution of the Compton camera is about 5.6 mm and the detection efficiency 10-5.


Physics in Medicine and Biology | 2015

Assessment and improvements of Geant4 hadronic models in the context of prompt-gamma hadrontherapy monitoring

N Arbor; D. Dauvergne; G. Dedes; J.M. Létang; Katia Parodi; C T Quiñones; E. Testa; Simon Rit

Proton computed tomography (CT) has been described as a solution for imaging the proton stopping power of patient tissues, therefore reducing the uncertainty of the conversion of x-ray CT images to relative stopping power (RSP) maps and its associated margins. This study aimed to investigate this assertion under the assumption of ideal detection systems. We have developed a Monte Carlo framework to assess proton CT performances for the main steps of a proton therapy treatment planning, i.e. proton or x-ray CT imaging, conversion to RSP maps based on the calibration of a tissue phantom, and proton dose simulations. Irradiations of a computational phantom with pencil beams were simulated on various anatomical sites and the proton range was assessed on the reference, the proton CT-based and the x-ray CT-based material maps. Errors on the tissues RSP reconstructed from proton CT were found to be significantly smaller and less dependent on the tissue distribution. The imaging dose was also found to be much more uniform and conformal to the primary beam. The mean absolute deviation for range calculations based on x-ray CT varies from 0.18 to 2.01 mm depending on the localization, while it is smaller than 0.1 mm for proton CT. Under the assumption of a perfect detection system, proton range predictions based on proton CT are therefore both more accurate and more uniform than those based on x-ray CT.


ieee nuclear science symposium | 2011

Design study of a Compton camera for prompt γ imaging during ion beam therapy

M.-H. Richard; M. Dahoumane; D. Dauvergne; M. De Rydt; George Dedes; N. Freud; J. Krimmer; J.M. Létang; X. Lojacono; V. Maxim; G. Montarou; C. Ray; F. Roellinghoff; E. Testa; A.H. Walenta

The goal of this study is to tune the design of the absorber detector of a Compton camera for prompt γ-ray imaging during ion beam therapy. The response of the Compton camera to a photon point source with a realistic energy spectrum (corresponding to the prompt γ-ray spectrum emitted during the carbon irradiation of a water phantom) is studied by means of Geant4 simulations. Our Compton camera consists of a stack of 2 mm thick silicon strip detectors as a scatter detector and of a scintillator plate as an absorber detector. Four scintillators are considered: LYSO, NaI, LaBr3 and BGO. LYSO and BGO appear as the most suitable materials, due to their high photo-electric cross-sections, which leads to a high percentage of fully absorbed photons. Depth-of-interaction measurements are shown to have limited influence on the spatial resolution of the camera. In our case, the thickness which gives the best compromise between a high percentage of photons that are fully absorbed and a low parallax error is about 4 cm for the LYSO detector and 4.5 cm for the BGO detector. The influence of the width of the absorber detector on the spatial resolution is not very pronounced as long as it is lower than 30 cm.


Journal of Instrumentation | 2015

Monte Carlo comparison of x-ray and proton CT for range calculations of proton therapy beams

J. Krimmer; M. Chevallier; J. Constanzo; D. Dauvergne; M. De Rydt; George Dedes; N. Freud; P. Henriquet; C. La Tessa; J.M. Létang; Radek Pleskac; M. Pinto; C. Ray; V. Reithinger; M.-H. Richard; I. Rinaldi; F. Roellinghoff; C. Schuy; E. Testa; M. Testa

Longitudinal prompt-gamma ray profiles have been measured with a multi-slit multi-detector configuration at a 75 MeV/u 13C beam and with a PMMA target. Selections in time-of-flight and energy have been applied in order to discriminate prompt-gamma rays produced in the target from background events. The ion ranges which have been extracted from each individual detector module agree amongst each other and are consistent with theoretical expectations. In a separate dedicated experiment with 200 MeV/u 12C ions the fraction of inter-detector scattering has been determined to be on the 10%-level via a combination of experimental results and simulations. At the same experiment different collimator configurations have been tested and the shielding properties of tungsten and lead for prompt-gamma rays have been measured.


Physics in Medicine and Biology | 2016

Design study of the absorber detector of a compton camera for on-line control in ion beam therapy

V. Maxim; X. Lojacono; E. Hilaire; J. Krimmer; E. Testa; D. Dauvergne; Isabelle E. Magnin; Rémy Prost

This paper addresses the problem of evaluating the system matrix and the sensitivity for iterative reconstruction in Compton camera imaging. Proposed models and numerical calculation strategies are compared through the influence they have on the three-dimensional reconstructed images. The study attempts to address four questions. First, it proposes an analytic model for the system matrix. Second, it suggests a method for its numerical validation with Monte Carlo simulated data. Third, it compares analytical models of the sensitivity factors with Monte Carlo simulated values. Finally, it shows how the system matrix and the sensitivity calculation strategies influence the quality of the reconstructed images.

Collaboration


Dive into the E. Testa's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

F. Roellinghoff

Université catholique de Louvain

View shared research outputs
Researchain Logo
Decentralizing Knowledge