Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ed Mok is active.

Publication


Featured researches published by Ed Mok.


Physics in Medicine and Biology | 1998

Monte Carlo calculations of electron beam output factors for a medical linear accelerator

Ajay Kapur; C.-M. Ma; Ed Mok; D. Findley; Arthur L. Boyer

The purpose of this study was to investigate the application of the Monte Carlo technique to the calculation and analysis of output factors for electron beams used in radiotherapy. The code EGS4/BEAM was used to obtain phase-space files for 6, 12 and 20 MeV clinical electron beams from a scattering-foil linac (Varian Clinac 2100C) for a clinically representative range of applicator and square or rectangular insert combinations. The source-to-surface distance used was 100 cm. The field sizes ranged from 1 x 1 cm2 to 20 x 20 cm2. These phase-space files were analysed to study the intrinsic beam characteristics and used as source input for relative dose and output factor computations in homogeneous water phantoms using the code EGS4/DOSXYZ. The calculated relative central-axis depth-dose and transverse dose profiles at various depths of clinical interest agreed with the corresponding measured dose profiles to within 2% of the maximum dose. Calculated output factors for the fields studied agreed with measured output factors to about 2%. This demonstrated that for the Varian Clinac 2100C linear accelerator, electron beam dose calculations in homogeneous water phantoms can be performed accurately at the 2% level using Monte Carlo simulations.


International Journal of Radiation Oncology Biology Physics | 2013

Dosimetric Analysis of Organs at Risk During Expiratory Gating in Stereotactic Body Radiation Therapy for Pancreatic Cancer

Cullen M. Taniguchi; James D. Murphy; Neville Eclov; Todd F. Atwood; K Kielar; Claudia Christman-Skieller; Ed Mok; Lei Xing; Albert C. Koong; Daniel T. Chang

PURPOSEnTo determine how the respiratory phase impacts dose to normal organs during stereotactic body radiation therapy (SBRT) for pancreatic cancer.nnnMETHODS AND MATERIALSnEighteen consecutive patients with locally advanced, unresectable pancreatic adenocarcinoma treated with SBRT were included in this study. On the treatment planning 4-dimensional computed tomography (CT) scan, the planning target volume (PTV), defined as the gross tumor volume plus 3-mm margin, the duodenum, and the stomach were contoured on the end-expiration (CTexp) and end-inspiration (CTinsp) phases for each patient. A separate treatment plan was constructed for both phases with the dose prescription of 33 Gy in 5 fractions with 95% coverage of the PTV by the 100% isodose line. The dose-volume histogram (DVH) endpoints, volume of duodenum that received 20 Gy (V20), V25, and V30 and maximum dose to 5 cc of contoured organ (D5cc), D1cc, and D0.1cc, were evaluated.nnnRESULTSnDosimetric parameters for the duodenum, including V25, V30, D1cc, and D0.1cc improved by planning on the CTexp compared to those on the CTinsp. There was a statistically significant overlap of the PTV with the duodenum but not the stomach during the CTinsp compared to the CTexp (0.38 ± 0.17 cc vs 0.01 ± 0.01 cc, P=.048). A larger expansion of the PTV, in accordance with a Danish phase 2 trial, showed even more overlapping volume of duodenum on the CTinsp compared to that on the CTexp (5.5 ± 0.9 cc vs 3.0 ± 0.8 cc, P=.0003) but no statistical difference for any stomach dosimetric DVH parameter.nnnCONCLUSIONSnDose to the duodenum was higher when treating on the inspiratory than on thexa0expiratory phase. These data suggest that expiratory gating may be preferable to inspiratory breath-hold and free breathing strategies for minimizing risk of toxicity.


Physics in Medicine and Biology | 2012

An end-to-end examination of geometric accuracy of IGRT using a new digital accelerator equipped with onboard imaging system

L. Wang; K Kielar; Ed Mok; A Hsu; Sonja Dieterich; Lei Xing

The Varians new digital linear accelerator (LINAC), TrueBeam STx, is equipped with a high dose rate flattening filter free (FFF) mode (6 MV and 10 MV), a high definition multileaf collimator (2.5 mm leaf width), as well as onboard imaging capabilities. A series of end-to-end phantom tests were performed, TrueBeam-based image guided radiation therapy (IGRT), to determine the geometric accuracy of the image-guided setup and dose delivery process for all beam modalities delivered using intensity modulated radiation therapy (IMRT) and RapidArc. In these tests, an anthropomorphic phantom with a Ball Cube II insert and the analysis software (FilmQA (3cognition)) were used to evaluate the accuracy of TrueBeam image-guided setup and dose delivery. Laser cut EBT2 films with 0.15 mm accuracy were embedded into the phantom. The phantom with the film inserted was first scanned with a GE Discovery-ST CT scanner, and the images were then imported to the planning system. Plans with steep dose fall off surrounding hypothetical targets of different sizes were created using RapidArc and IMRT with FFF and WFF (with flattening filter) beams. Four RapidArc plans (6 MV and 10 MV FFF) and five IMRT plans (6 MV and 10 MV FFF; 6 MV, 10 MV and 15 MV WFF) were studied. The RapidArc plans with 6 MV FFF were planned with target diameters of 1 cm (0.52 cc), 2 cm (4.2 cc) and 3 cm (14.1 cc), and all other plans with a target diameter of 3 cm. Both onboard planar and volumetric imaging procedures were used for phantom setup and target localization. The IMRT and RapidArc plans were then delivered, and the film measurements were compared with the original treatment plans using a gamma criteria of 3%/1 mm and 3%/2 mm. The shifts required in order to align the film measured dose with the calculated dose distributions was attributed to be the targeting error. Targeting accuracy of image-guided treatment using TrueBeam was found to be within 1 mm. For irradiation of the 3 cm target, the gammas (3%, 1 mm) were found to be above 90% in all plan deliveries. For irradiations of smaller targets (2 cm and 1 cm), similar accuracy was achieved for 6 MV and 10 MV beams. Slightly degraded accuracy was observed for irradiations with higher energy beam (15 MV). In general, gammas (3%, 2 mm) were found to be above 97% for all the plans. Our end-to-end tests showed an excellent relative dosimetric agreement and sub-millimeter targeting accuracy for 6 MV and 10 MV beams, using both FFF and WFF delivery methods. However, increased deviations in spatial and dosimetric accuracy were found when treating lesions smaller than 2 cm or with 15 MV beam.


Medical Physics | 2011

Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters

W Cho; K Kielar; Ed Mok; Lei Xing; Jeong-Hoon Park; Won-Gyun Jung; Tae-Suk Suh

PURPOSEnWith the introduction of flattening filter free (FFF) linear accelerators to radiation oncology, new analytical source models for a FFF beam applicable to current treatment planning systems is needed. In this work, a multisource model for the FFF beam and the optimization of involved model parameters were designed.nnnMETHODSnThe model is based on a previous three source model proposed by Yang et al. [A three-source model for the calculation of head scatter factors, Med. Phys. 29, 2024-2033 (2002)]. An off axis ratio (OAR) of photon fluence was introduced to the primary source term to generate cone shaped profiles. The parameters of the source model were determined from measured head scatter factors using a line search optimization technique. The OAR of the photon fluence was determined from a measured dose profile of a 40 x 40 cm2 field size with the same optimization technique, but a new method to acquire gradient terms for OARs was developed to enhance the speed of the optimization process. The improved model was validated with measured dose profiles from 3 x 3 to 40 x 40 cm2 field sizes at 6 and 10 MV from a TrueBeam STx linear accelerator. Furthermore, planar dose distributions for clinically used radiation fields were also calculated and compared to measurements using a 2D array detector using the gamma index method.nnnRESULTSnAll dose values for the calculated profiles agreed with the measured dose profiles within 0.5% at 6 and 10 MV beams, except for some low dose regions for larger field sizes. A slight overestimation was seen in the lower penumbra region near the field edge for the large field sizes by 1%-4%. The planar dose calculations showed comparable passing rates (> 98%) when the criterion of the gamma index method was selected to be 3%/3 mm.nnnCONCLUSIONSnThe developed source model showed good agreements between measured and calculated dose distributions. The model is easily applicable to any other linear accelerator using FFF beams as the required data include only the measured PDD, dose profiles, and output factors for various field sizes, which are easily acquired during conventional beam commissioning process.


Medical Physics | 2011

Verification of dosimetric accuracy on the TrueBeam STx: rounded leaf effect of the high definition MLC.

K Kielar; Ed Mok; A Hsu; L. Wang; Gary Luxton

PURPOSEnThe dosimetric leaf gap (DLG) in the Varian Eclipse treatment planning system is determined during commissioning and is used to model the effect of the rounded leaf-end of the multileaf collimator (MLC). This parameter attempts to model the physical difference between the radiation and light field and account for inherent leakage between leaf tips. With the increased use of single fraction high dose treatments requiring larger monitor units comes an enhanced concern in the accuracy of leakage calculations, as it accounts for much of the patient dose. This study serves to verify the dosimetric accuracy of the algorithm used to model the rounded leaf effect for the TrueBeam STx, and describes a methodology for determining best-practice parameter values, given the novel capabilities of the linear accelerator such as flattening filter free (FFF) treatments and a high definition MLC (HDMLC).nnnMETHODSnDuring commissioning, the nominal MLC position was verified and the DLG parameter was determined using MLC-defined field sizes and moving gap tests, as is common in clinical testing. Treatment plans were created, and the DLG was optimized to achieve less than 1% difference between measured and calculated dose. The DLG value found was tested on treatment plans for all energies (6 MV, 10 MV, 15 MV, 6 MV FFF, 10 MV FFF) and modalities (3D conventional, IMRT, conformal arc, VMAT) available on the TrueBeam STx.nnnRESULTSnThe DLG parameter found during the initial MLC testing did not match the leaf gap modeling parameter that provided the most accurate dose delivery in clinical treatment plans. Using the physical leaf gap size as the DLG for the HDMLC can lead to 5% differences in measured and calculated doses.nnnCONCLUSIONSnSeparate optimization of the DLG parameter using end-to-end tests must be performed to ensure dosimetric accuracy in the modeling of the rounded leaf ends for the Eclipse treatment planning system. The difference in leaf gap modeling versus physical leaf gap dimensions is more pronounced in the more recent versions of Eclipse for both the HDMLC and the Millennium MLC. Once properly commissioned and tested using a methodology based on treatment plan verification, Eclipse is able to accurately model radiation dose delivered for SBRT treatments using the TrueBeam STx.


Medical Physics | 2013

Development of a fast and feasible spectrum modeling technique for flattening filter free beams

W Cho; K Bush; Ed Mok; Lei Xing; Tae-Suk Suh

PURPOSEnTo develop a fast and robust technique for the determination of optimized photon spectra for flattening filter free (FFF) beams to be applied in convolution/superposition dose calculations.nnnMETHODSnA two-step optimization method was developed to derive optimal photon spectra for FFF beams. In the first step, a simple functional form of the photon spectra proposed by Ali [Functional forms for photon spectra of clinical linacs, Phys. Med. Biol. 57, 31-50 (2011)] is used to determine generalized shapes of the photon spectra. In this method, the photon spectra were defined for the ranges of field sizes to consider the variations of the contributions of scattered photons with field size. Percent depth doses (PDDs) for each field size were measured and calculated to define a cost function, and a collapsed cone convolution (CCC) algorithm was used to calculate the PDDs. In the second step, the generalized functional form of the photon spectra was fine-tuned in a process whereby the weights of photon fluence became the optimizing free parameters. A line search method was used for the optimization and first order derivatives with respect to the optimizing parameters were derived from the CCC algorithm to enhance the speed of the optimization. The derived photon spectra were evaluated, and the dose distributions using the optimized spectra were validated.nnnRESULTSnThe optimal spectra demonstrate small variations with field size for the 6 MV FFF beam and relatively large variations for the 10 MV FFF beam. The mean energies of the optimized 6 MV FFF spectra were decreased from 1.31 MeV for a 3 × 3 cm(2) field to 1.21 MeV for a 40 × 40 cm(2) field, and from 2.33 MeV at 3 × 3 cm(2) to 2.18 MeV at 40 × 40 cm(2) for the 10 MV FFF beam. The developed method could significantly improve the agreement between the calculated and measured PDDs. Root mean square differences on the optimized PDDs were observed to be 0.41% (3 × 3 cm(2)) down to 0.21% (40 × 40 cm(2)) for the 6 MV FFF beam, and 0.35% (3 × 3 cm(2)) down to 0.29% (40 × 40 cm(2)) for the 10 MV FFF beam. The first order derivatives from the functional form were found to improve the speed of computational time up to 20 times compared to the other techniques.nnnCONCLUSIONSnThe derived photon spectra resulted in good agreements with measured PDDs over the range of field sizes investigated. The suggested method is easily applicable to commercial radiation treatment planning systems since it only requires measured PDDs as input.


international conference on machine learning and applications | 2011

Development of a Beam Source Modeling Technique for a Flattening Filter Free (FFF) Beam

W Cho; Jeong-Hoon Park; Won-Gyun Jung; Tae-Suk Suh; K Kielar; Ed Mok; Ruijiang Li; Lei Xing

This study was focused on a new beam source modeling technique for a flattening filter free (FFF) beam. The model was based on a previous three source model, and improved by introducing off axis ratio (OAR) of photon fluence to the primary and scattered photon sources to generate cone shaped dose profiles. The model parameters and the OAR were optimized from measured head scatter factors and a dose profile with 40 x 40 cm2 field size by using line search optimization algorithm. The model was validated by comparing various dose profiles on 6 and 10 MV FFF beam from a True Beam STx linear accelerator. Planar dose distributions for clinically used radiation fields were also calculated and compared with measured data. All calculated dose profiles were agreed with the measured data within 1.5% for 6 MV FFF beam, and within 1% for 10 MV FFF beam. The calculated planar doses showed good passing rates (> 94%) at 3%/3 mm of gamma indexing criteria. This model expected to be easily applicable to any FFF beams for treatment planning systems because it only required measured PDD, dose profiles and output factors which were easily acquired during conventional beam commissioning process.


International Journal of Radiation Oncology Biology Physics | 1997

2222 Physical characterization of a miniature multileaf collimator

Paul Geis; Ken Forster; P. Xia; Ed Mok; Lei Xing; Arthur L. Boyer


International Journal of Radiation Oncology Biology Physics | 1998

Implementation of dynamic conformal arcs with a Mini-MLC*

Arthur L. Boyer; K.M. Forster; P. Geis; C-M. Ma; Ed Mok; Lei Xing; D. Findley; S. Chang; E. Lindquist; M. Ahrens; S. Froelich


International Journal of Radiation Oncology Biology Physics | 1998

Verification of IMRT dose calculations using monte carlo simulaitons

C.-M. Ma; Lei Xing; Ed Mok; Ajay Kapur; Arthur L. Boyer

Collaboration


Dive into the Ed Mok's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Tae-Suk Suh

Catholic University of Korea

View shared research outputs
Top Co-Authors

Avatar

W Cho

Seoul National University Hospital

View shared research outputs
Top Co-Authors

Avatar

A Hsu

Stanford University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge