Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Edmond Sterpin is active.

Publication


Featured researches published by Edmond Sterpin.


Medical Physics | 2007

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator

Edmond Sterpin; Milan Tomsej; B De Smedt; Nick Reynaert; Stefaan Vynckier

The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2 x 2 cm(2)). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to the bone ribs were not fully taken into account by AAA, and small inhomogeneities may lead to planning errors. Second, AAA and MC were compared for IMRT plans in clinical conditions, i.e., dose calculations in a computed tomography scan of a patient. One ethmoid tumor, one orophaxynx and two lung tumors are presented in this paper. Small differences were found between the dose volume histograms. For instance, a 1.7% difference for the mean planning target volume dose was obtained for the ethmoid case. Since better agreement was achieved for the same plans but in homogeneous conditions, these differences must be attributed to the handling of inhomogeneities by AAA. Therefore, inherent assumptions of the algorithm, principally the assumption of independent depth and lateral directions in the scaling of the kernels, were slightly influencing AAAs validity in inhomogeneities. However, AAA showed a good accuracy overall and a great ability to handle small fields in inhomogeneous media compared to other pencil beam convolution algorithms.


Acta Oncologica | 2015

Hypoxia-guided adaptive radiation dose escalation in head and neck carcinoma: A planning study

Stéphanie Servagi-Vernat; Sarah Differding; Edmond Sterpin; François-Xavier Hanin; Daniel Labar; Anne Bol; John Aldo Lee; Vincent Grégoire

Abstract Objective. To evaluate from a planning point of view the dose distribution of adaptive radiation dose escalation in head and neck squamous cell carcinoma (HNSCC) using 18F-Fluoroazomycin arabinoside (FAZA) positron emission tomography/computed tomography (PET-CT). Material/methods. Twelve patients with locally advanced HNSCC underwent three FAZA PET-CT before treatment, after 7 fractions and after 17 fractions of a carboplatin-5FU chemo-radiotherapy regimen (70 Gy in 2 Gy per fraction over 7 weeks). The dose constraints were that every hypoxic voxel delineated before and during treatment (newborn hypoxic voxels) should receive a total dose of 86 Gy. A median dose of 2.47 Gy per fraction was prescribed on the hypoxic PTV defined on the pre-treatment FAZA PET-CT; a median dose of 2.57 Gy per fraction was prescribed on the newborn voxels identified on the first per-treatment FAZA PET-CT; a median dose of 2.89 Gy per fraction was prescribed on the newborn voxels identified on the second per-treatment FAZA PET-CT. Results. Ten of 12 patients had hypoxic volumes. Six of 10 patients completed all the FAZA PET-CT during radiotherapy. For the hypoxic PTVs, the average D50% matched the prescribed dose within 2% and the homogeneity indices reached 0.10 and 0.12 for the nodal PTV 86 Gy and the primary PTV 86 Gy, respectively. Compared to a homogeneous 70 Gy mean dose to the PTVs, the dose escalation up to 86 Gy to the hypoxic volumes did not typically modify the dose metrics on the surrounding normal tissues. Conclusion. From a planning point of view, FAZA-PET-guided dose adaptive escalation is feasible without substantial dose increase to normal tissues above tolerance limits. Clinical prospective studies, however, need to be performed to validate hypoxia-guided adaptive radiation dose escalation in head and neck carcinoma.


Physics in Medicine and Biology | 2015

Measurement of prompt gamma profiles in inhomogeneous targets with a knife-edge slit camera during proton irradiation.

Marlen Priegnitz; Stephan Helmbrecht; Guillaume Janssens; I. Perali; J. Smeets; F Vander Stappen; Edmond Sterpin; F. Fiedler

Proton and ion beam therapies become increasingly relevant in radiation therapy. To fully exploit the potential of this irradiation technique and to achieve maximum target volume conformality, the verification of particle ranges is highly desirable. Many research activities focus on the measurement of the spatial distributions of prompt gamma rays emitted during irradiation. A passively collimating knife-edge slit camera is a promising option to perform such measurements. In former publications, the feasibility of accurate detection of proton range shifts in homogeneous targets could be shown with such a camera. We present slit camera measurements of prompt gamma depth profiles in inhomogeneous targets. From real treatment plans and their underlying CTs, representative beam paths are selected and assembled as one-dimensional inhomogeneous targets built from tissue equivalent materials. These phantoms have been irradiated with monoenergetic proton pencil beams. The accuracy of range deviation estimation as well as the detectability of range shifts is investigated in different scenarios. In most cases, range deviations can be detected within less than 2 mm. In close vicinity to low-density regions, range detection is challenging. In particular, a minimum beam penetration depth of 7 mm beyond a cavity is required for reliable detection of a cavity filling with the present setup. Dedicated data post-processing methods may be capable of overcoming this limitation.


Medical Physics | 2012

Validation of GPU based TomoTherapy dose calculation engine.

Quan Chen; Weiguo Lu; Yu Chen; Mingli Chen; Douglas Henderson; Edmond Sterpin

PURPOSE The graphic processing unit (GPU) based TomoTherapy convolution/superposition(C/S) dose engine (GPU dose engine) achieves a dramatic performance improvement over the traditional CPU-cluster based TomoTherapy dose engine (CPU dose engine). Besides the architecture difference between the GPU and CPU, there are several algorithm changes from the CPU dose engine to the GPU dose engine. These changes made the GPU dose slightly different from the CPU-cluster dose. In order for the commercial release of the GPU dose engine, its accuracy has to be validated. METHODS Thirty eight TomoTherapy phantom plans and 19 patient plans were calculated with both dose engines to evaluate the equivalency between the two dose engines. Gamma indices (Γ) were used for the equivalency evaluation. The GPU dose was further verified with the absolute point dose measurement with ion chamber and film measurements for phantom plans. Monte Carlo calculation was used as a reference for both dose engines in the accuracy evaluation in heterogeneous phantom and actual patients. RESULTS The GPU dose engine showed excellent agreement with the current CPU dose engine. The majority of cases had over 99.99% of voxels with Γ(1%, 1 mm) < 1. The worst case observed in the phantom had 0.22% voxels violating the criterion. In patient cases, the worst percentage of voxels violating the criterion was 0.57%. For absolute point dose verification, all cases agreed with measurement to within ±3% with average error magnitude within 1%. All cases passed the acceptance criterion that more than 95% of the pixels have Γ(3%, 3 mm) < 1 in film measurement, and the average passing pixel percentage is 98.5%-99%. The GPU dose engine also showed similar degree of accuracy in heterogeneous media as the current TomoTherapy dose engine. CONCLUSIONS It is verified and validated that the ultrafast TomoTherapy GPU dose engine can safely replace the existing TomoTherapy cluster based dose engine without degradation in dose accuracy.


Physics in Medicine and Biology | 2015

Analytical computation of prompt gamma ray emission and detection for proton range verification

Edmond Sterpin; Guillaume Janssens; J. Smeets; François Vander Stappen; Damian Prieels; Marlen Priegnitz; I. Perali; Stefaan Vynckier

A prompt gamma (PG) slit camera prototype recently demonstrated that Bragg Peak position in a clinical proton scanned beam could be measured with 1-2 mm accuracy by comparing an expected PG detection profile to a measured one. The computation of the expected PG detection profile in the context of a clinical framework is challenging but must be solved before clinical implementation. Obviously, Monte Carlo methods (MC) can simulate the expected PG profile but at prohibitively long calculation times. We implemented a much faster method that is based on analytical processing of precomputed MC data that would allow practical evaluation of this range monitoring approach in clinical conditions. Reference PG emission profiles were generated with MC simulations (PENH) in targets consisting of either (12)C, (14)N, (16)O, (31)P or (40)Ca, with 10% of (1)H. In a given geometry, the local PG emission can then be derived by adding the contribution of each element, according to the local energy of the proton obtained by continuous slowing down approximation and the local composition. The actual incident spot size is taken into account using an optical model fitted to measurements and by super sampling the spot with several rays (up to 113). PG transport in the patient/camera geometries and the detector response are modelled by convolving the PG production profile with a transfer function. The latter is interpolated from a database of transfer functions fitted to MC data (PENELOPE) generated for a photon source in a cylindrical phantom with various radiuses and a camera placed at various positions. As a benchmark, the analytical model was compared to MC and experiments in homogeneous and heterogeneous phantoms. Comparisons with MC were also performed in a thoracic CT. For all cases, the analytical model reproduced the prediction of the position of the Bragg peak computed with MC within 1 mm for the camera in nominal configuration. When compared to measurements, the shape of the profiles was well reproduced and agreement for the estimation of the position of the Bragg peak was within 2.7 mm on average (1.4 mm standard deviation). On a non-optimized MATLAB code, computation time with the analytical model is between 0.3 to 10 s depending on the number of rays simulated per spot. The analytical model can be further used to determine which spots are the best candidates to evaluate the range in clinical conditions and eventually correct for over- and under-shoots depending on the acquired PG profiles.


Medical Physics | 2013

Extension of PENELOPE to protons: simulation of nuclear reactions and benchmark with Geant4.

Edmond Sterpin; Jefferson Sorriaux; Stefaan Vynckier

PURPOSE Describing the implementation of nuclear reactions in the extension of the Monte Carlo code (MC) PENELOPE to protons (PENH) and benchmarking with Geant4. METHODS PENH is based on mixed-simulation mechanics for both elastic and inelastic electromagnetic collisions (EM). The adopted differential cross sections for EM elastic collisions are calculated using the eikonal approximation with the Dirac-Hartree-Fock-Slater atomic potential. Cross sections for EM inelastic collisions are computed within the relativistic Born approximation, using the Sternheimer-Liljequist model of the generalized oscillator strength. Nuclear elastic and inelastic collisions were simulated using explicitly the scattering analysis interactive dialin database for (1)H and ICRU 63 data for (12)C, (14)N, (16)O, (31)P, and (40)Ca. Secondary protons, alphas, and deuterons were all simulated as protons, with the energy adapted to ensure consistent range. Prompt gamma emission can also be simulated upon user request. Simulations were performed in a water phantom with nuclear interactions switched off or on and integral depth-dose distributions were compared. Binary-cascade and precompound models were used for Geant4. Initial energies of 100 and 250 MeV were considered. For cases with no nuclear interactions simulated, additional simulations in a water phantom with tight resolution (1 mm in all directions) were performed with FLUKA. Finally, integral depth-dose distributions for a 250 MeV energy were computed with Geant4 and PENH in a homogeneous phantom with, first, ICRU striated muscle and, second, ICRU compact bone. RESULTS For simulations with EM collisions only, integral depth-dose distributions were within 1%/1 mm for doses higher than 10% of the Bragg-peak dose. For central-axis depth-dose and lateral profiles in a phantom with tight resolution, there are significant deviations between Geant4 and PENH (up to 60%/1 cm for depth-dose distributions). The agreement is much better with FLUKA, with deviations within 3%/3 mm. When nuclear interactions were turned on, agreement (within 6% before the Bragg-peak) between PENH and Geant4 was consistent with uncertainties on nuclear models and cross sections, whatever the material simulated (water, muscle, or bone). CONCLUSIONS A detailed and flexible description of nuclear reactions has been implemented in the PENH extension of PENELOPE to protons, which utilizes a mixed-simulation scheme for both elastic and inelastic EM collisions, analogous to the well-established algorithm for electrons/positrons. PENH is compatible with all current main programs that use PENELOPE as the MC engine. The nuclear model of PENH is realistic enough to give dose distributions in fair agreement with those computed by Geant4.


Journal of Physics: Conference Series | 2007

Monte Carlo simulation of the Tomotherapy treatment unit in the static mode using MC HAMMER, a Monte Carlo tool dedicated to Tomotherapy

Edmond Sterpin; M. Tomsej; B. Cravens; F. Salvat; K. Ruchala; G.H. Olivera; Stefaan Vynckier

Helical tomotherapy (HT) is designed to deliver highly modulated IMRT treatments. The concept of HT provides new challenges in MC simulation, because simultaneous movement of the gantry, the couch and the multi-leaf collimator (MLC) must be simulated accurately. However, before accounting for gantry, couch movement and multileaf collimator configurations, high accuracy must be achieved while simulating open static fields (1 times 40, 2.5 times 40 and 5 times 40 cm 2). This is performed using MC HAMMER, which is a graphical user interface allowing MC simulation using PENELOPE for various configurations of HT. Since the geometry of the different elements and materials involved in the beam generation are precisely known and defined, the only parameters that need to be tuned on are therefore electron source spot size and electron energy. Beyond the build up region, good agreement (2%/1 mm) is achieved for all the field sizes between measurements (ion chamber) and simulations with an electron source energy set to 5.5 MeV. The electron source spot size is modelled as a gaussian distribution with full width half maximum equal to 1.4 mm. This value was chosen to match measured and calculated penumbras in the longitudinal direction.


Radiotherapy and Oncology | 2013

Validation of the mid-position strategy for lung tumors in helical TomoTherapy

Marie Wanet; Edmond Sterpin; Guillaume Janssens; Antoine Delor; John Aldo Lee; Xavier Geets

PURPOSE To compare the mid-position (MidP) strategy to the conventional internal target volume (ITV) for lung tumor management in helical TomoTherapy, using 4D Monte Carlo (MC) plan simulations. MATERIALS AND METHODS For NSCLC patients treated by SBRT (n = 8) or SIB-IMRT (n = 7), target volumes and OARs were delineated on a contrast-enhanced CT, while 4D-CT was used to generate either ITV or MidP volumes with deformable registrations. PTV margins were added. Conformity indexes, volumetric and dosimetric parameters were compared for both strategies. Dose distributions were also computed using a 4D MC model (TomoPen) to assess how intra-fraction tumor motion affects tumor coverage, with and without interplay effect. RESULTS PTVs derived from MidP were on average 1.2 times smaller than those from ITV, leading to lower doses to OARs. Planned dose conformity to TVs was similar for both strategies. 4D MC computation showed that ITV ensured adequate TV coverage (D95 within 1% of clinical requirements), while MidP failed in 3 patients of the SBRT group (D95 to the TV lowered by 4.35%, 2.16% and 2.61%) due to interplay effect in one case and to breathing motion alone in the others. CONCLUSIONS Compared to the ITV, the MidP significantly reduced PTV and doses to OARs. MidP is safe for helical delivery except for very small tumors (<5 cc) with large-amplitude motion (>10mm) where the ITV might remain the most adequate approach.


Acta Oncologica | 2015

Generation of prescriptions robust against geometric uncertainties in dose painting by numbers

Edmond Sterpin; Sarah Differding; Guillaume Janssens; Xavier Geets; Vincent Grégoire; John Aldo Lee

Abstract Background. In the context of dose painting by numbers delivered with intensity-modulated radiotherapy, the robustness of dose distributions against geometric uncertainties can be ensured by robust optimization. As robust optimization is seldom available in treatment planning systems (TPS), we propose an alternative method that reaches the same goal by modifying the heterogeneous dose prescription (based on 18FDG-PET) and guarantees coverage in spite of systematic and random errors with known standard deviations Σ and σ, respectively. Material and methods. The objective was that 95% of all voxels in the GTVPET received at least 95% of the prescribed dose despite geometric errors. The prescription was modified by a geometric dilation of αΣ for systematic errors and a deconvolution by a Gaussian function of width σ for random errors. For a 90% confidence interval, α = 2.5. Planning was performed on a TomoTherapy system, such that 95% of the voxels received at least 95% of the modified prescription and less than 5% of the voxels received more than 105% of the modified prescription. The applicability of the method was illustrated for two head-and-neck tumors. Results. Systematic and random displacements larger than αΣ and σ degraded coverage. Down to 62.8% of the points received at least 95% of prescribed dose for the largest considered displacements (5 mm systematic translation and 3 mm standard deviation for random errors). When systematic and random displacements were smaller than αΣ and σ, no degradation of target coverage was observed. Conclusions. The method led to treatment plans with target coverage robust against geometric uncertainties without the need to incorporate these in the optimizer of the TPS. The methodology was illustrated for head-and-neck cancer but can be potentially extended to all treatment sites.


Medical Physics | 2015

Monte Carlo simulations of patient dose perturbations in rotational-type radiotherapy due to a transverse magnetic field: A tomotherapy investigation

Y. M. Yang; Mark Geurts; J Smilowitz; Edmond Sterpin; B Bednarz

PURPOSE Several groups are exploring the integration of magnetic resonance (MR) image guidance with radiotherapy to reduce tumor position uncertainty during photon radiotherapy. The therapeutic gain from reducing tumor position uncertainty using intrafraction MR imaging during radiotherapy could be partially offset if the negative effects of magnetic field-induced dose perturbations are not appreciated or accounted for. The authors hypothesize that a more rotationally symmetric modality such as helical tomotherapy will permit a systematic mediation of these dose perturbations. This investigation offers a unique look at the dose perturbations due to homogeneous transverse magnetic field during the delivery of Tomotherapy(®) Treatment System plans under varying degrees of rotational beamlet symmetry. METHODS The authors accurately reproduced treatment plan beamlet and patient configurations using the Monte Carlo code geant4. This code has a thoroughly benchmarked electromagnetic particle transport physics package well-suited for the radiotherapy energy regime. The three approved clinical treatment plans for this study were for a prostate, head and neck, and lung treatment. The dose heterogeneity index metric was used to quantify the effect of the dose perturbations to the target volumes. RESULTS The authors demonstrate the ability to reproduce the clinical dose-volume histograms (DVH) to within 4% dose agreement at each DVH point for the target volumes and most planning structures, and therefore, are able to confidently examine the effects of transverse magnetic fields on the plans. The authors investigated field strengths of 0.35, 0.7, 1, 1.5, and 3 T. Changes to the dose heterogeneity index of 0.1% were seen in the prostate and head and neck case, reflecting negligible dose perturbations to the target volumes, a change from 5.5% to 20.1% was observed with the lung case. CONCLUSIONS This study demonstrated that the effect of external magnetic fields can be mitigated by exploiting a more rotationally symmetric treatment modality.

Collaboration


Dive into the Edmond Sterpin's collaboration.

Top Co-Authors

Avatar

Stefaan Vynckier

Cliniques Universitaires Saint-Luc

View shared research outputs
Top Co-Authors

Avatar

John Aldo Lee

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

Guillaume Janssens

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

Kevin Souris

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

T Mackie

University of Wisconsin-Madison

View shared research outputs
Top Co-Authors

Avatar

Weiguo Lu

University of Texas Southwestern Medical Center

View shared research outputs
Top Co-Authors

Avatar

Vincent Grégoire

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

D. Prieels

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

J. Smeets

Université catholique de Louvain

View shared research outputs
Top Co-Authors

Avatar

Jefferson Sorriaux

Université catholique de Louvain

View shared research outputs
Researchain Logo
Decentralizing Knowledge