Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Edson Alfredo is active.

Publication


Featured researches published by Edson Alfredo.


Brazilian Dental Journal | 2008

Adhesion of Epiphany and AH Plus Sealers to Human Root Dentin Treated with Different Solutions

Vinicius Humberto Nunes; Ricardo Gariba Silva; Edson Alfredo; Manoel Damião Sousa-Neto; Yara Teresinha Corrêa Silva-Sousa

This study evaluated comparatively the adhesion of Epiphany and AH Plus endodontic sealers to human root dentin treated with 1% NaOCl and 1% NaOCl+17% EDTA, using the push-out test. Sixty root cylinders obtained from maxillary canines had the canals prepared and were randomly assigned to 3 groups (n=20), according to root dentin treatment: GI - distilled water (control), GII - 1% NaOCl and GIII - 1% NaOCl+17% EDTA. Each group was divided into 2 subgroups (n=10) filled with either Epiphany or AH Plus. Bond strength push-out test data (kN) were obtained and analyzed statistically by ANOVA and Tukeys post-hoc test. There was statistically significant difference between sealers (AH Plus: 0.78 +/- 0.13; Epiphany: 0.61 +/- 0.19; p<0.01) and among root dentin treatments (distilled water: 0.58 +/- 0.19; 1% NaOCl: 0.71 +/- 0.12; 1% NaOCl+17% EDTA: 0.80 +/- 0.17; p<0.05). In conclusion, AH Plus sealer presented greater adhesion to dentin than Epiphany, regardless of the treatment of root canal walls.


Journal of Dentistry | 2008

Temperature variation at the external root surface during 980-nm diode laser irradiation in the root canal

Edson Alfredo; Melissa Andréia Marchesan; Manoel Damião Sousa-Neto; Aldo Brugnera-Junior; Y. T. C. Silva-Sousa

OBJECTIVE To assess the temperature variation in the cervical, middle and apical thirds of root external wall, caused by 980-nm diode laser irradiation with different parameters. METHODS The roots of 90 canines, had their canals instrumented and were randomly distributed into 3 groups (n=30) according to the laser potency (1.5 W, 3.0 W and 5.0 W). Each group was subdivided into 3 (n=10) according to the frequency (CM, 100 Hz and 1000 Hz), and each subgroup divided into 2 (n=5): dried canal or filled with distilled water. The maximum temperature values were collected by 3 thermocouples located at each third of the root external wall and recorded by digital thermometers. RESULTS The groups irradiated in the continuous mode (CM) presented the highest values (11.82+/-5.78), regardless of the canals were dry or not, which were statistically different (p<0.01) from those obtained with 100 Hz (6.22+/-3.64) and 1000 Hz (6.00+/-3.36), which presented no statistical difference between them (p>0.01). The groups irradiated with 5.0 W presented the greatest temperature variation (12.15+/-5.14), followed by 3.0 W (7.88+/-3.92) and 1.5 W (4.02+/-2.16), differing between them (p<0.01). The cervical third of the root presented the highest temperature rises (9.68+/-5.80), followed by the middle (7.66+/-4.87) and apical (6.70+/-4.23), with statistical difference among them (p<0.01). After 30s from the end of irradiation, all the specimens presented temperature variation lower than 10 degrees C. CONCLUSIONS Application of 980-nm diode laser in the root, at 1.5 W in all operating modes, and 3.0 W, in the pulsed mode, for 20s, can safely be used in endodontic treatment, irrespective of the presence of humidity.


Journal of Endodontics | 2009

Bond Strength of Epiphany Sealer Prepared with Resinous Solvent

Fuad Jacob Abi Rached-Junior; Aline Evangelista Souza-Gabriel; Edson Alfredo; Carlos Eduardo Saraiva Miranda; Yara Teresinha Corrêa Silva-Sousa; Manoel Damião Sousa-Neto

This study evaluated in vitro the bond strength of Epiphany sealer prepared with resinous solvent of Epiphany system (Thinning resin) by using a push-out test. Forty maxillary canines were sectioned transversally below the cementoenamel junction to provide 4-mm-thick dentin disks that were centered in aluminum rings and embedded in acrylic resin. Root canals were prepared with tapered diamond bur. Intraradicular dentin was treated with 1% NaOCl for 30 minutes, 17% ethylenediaminetetraacetic acid for 5 minutes, and flushed with distilled water for 1 minute. The specimens were randomly distributed into 4 groups (n = 10) according to the filling material: GI, Epiphany without photoactivation; GII, Epiphany prepared with solvent without photoactivation; GIII, Epiphany followed by photoactivation; and GIV, Epiphany prepared with solvent followed by photoactivation. After the setting time, the specimens were submitted to the push-out test. The highest mean value (14.91 +/- 2.82 MPa) was obtained with Epiphany prepared with solvent followed by photoactivation (GIV), which was statistically different (P < .01) from the other groups. Groups I (8.15 +/- 2.47 MPa), II (9.46 +/- 2.38 MPa), and III (9.80 +/- 2.51 MPa) had inferior bond strength values and were statistically similar among themselves (P > .01). The resinous solvent of Epiphany system increased the bond strength of Epiphany sealer to dentin walls when followed by photoactivation.


Microscopy Research and Technique | 2009

Morphological alterations of radicular dentine pretreated with different irrigating solutions and irradiated with 980‐nm diode laser

Edson Alfredo; Aline Evangelista Souza-Gabriel; Silvio Rocha Corrêa da Silva; Manoel Damião Sousa-Neto; Aldo Brugnera-Junior; Yara Teresinha Corrêa Silva-Sousa

Background: The topographical features of intraradicular dentine pretreated with sodium hypochlorite (NaOCl) or ethylenediamine tetraacetic acid (EDTA) followed by diode laser irradiation have not yet been determined. Purpose: To evaluate the alterations of dentine irradiated with 980‐nm diode laser at different parameters after the surface treatment with NaOCl and EDTA. Study design: Roots of 60 canines were biomechanically prepared and irrigated with NaOCl or EDTA. Groups were divided according to the laser parameters: 1.5 W/CW; 1.5 W/100 Hz; 3.0 W/CW; 3.0 W/100 Hz and no irradiation (control). The roots were splited longitudinally and analyzed by scanning electron microscopy (SEM) in a quali‐quatitative way. The scores were submitted to two‐way Kruskal–Wallis and Dunns tests. Results: The statistical analysis demonstrated that the specimens treated only with NaOCl or EDTA (control groups) were statistically different (P < 0.05) from the laser‐irradiated specimens, regardless of the parameter setting. The specimens treated with NaOCl showed a laser‐modified surface with smear layer, fissures, and no visible tubules. Those treated with EDTA and irradiated by laser presented absence of smear layer, tubules partially exposed and melting areas. Conclusions: The tested parameters of 980‐nm diode laser promoted similar alterations on dentine morphology, dependent to the type of surface pretreatment. Microsc. Res. Tech., 2009.


Journal of Applied Oral Science | 2009

Adhesion of an endodontic sealer to dentin and gutta-percha: shear and push-out bond strength measurements and SEM analysis

Cleonice Silveira Teixeira; Edson Alfredo; Luis Henrique de Camargo Thomé; Ricardo Gariba-Silva; Yara Teresinha Corrêa Silva-Sousa; Manoel Damião Sousa-Neto

The use of an adequate method for evaluation of the adhesion of root canal filling materials provides more reliable results to allow comparison of the materials and substantiate their clinical choice. The aims of this study were to compare the shear bond strength (SBS) test and push-out test for evaluation of the adhesion of an epoxy-based endodontic sealer (AH Plus) to dentin and guttapercha, and to assess the failure modes on the debonded surfaces by means of scanning electron microscopy (SEM). Three groups were established (n=7): in group 1, root cylinders obtained from human canines were embedded in acrylic resin and had their canals prepared and filled with sealer; in group 2, longitudinal sections of dentin cylinders were embedded in resin with the canal surface smoothed and turned upwards; in group 3, gutta-percha cylinders were embedded in resin. Polyethylene tubes filled with sealer were positioned on the polished surface of the specimens (groups 2 and 3). The push-out test (group 1) and the SBS test (groups 2 and 3) were performed in an Instron universal testing machine running at crosshead speed of 1 mm/min. Means (±SD) in MPa were: G1 (8.8±1.13), G2 (5.9±1.05) and G3 (3.8±0.55). Statistical analysis by ANOVA and Students t-test (α=0.05) revealed statistically significant differences (p<0.01) among the groups. SEM analysis showed a predominance of adhesive and mixed failures of AH Plus sealer. The tested surface affected significantly the results with the sealer reaching higher bond strength to dentin than to guttapercha with the SBS test. The comparison of the employed methodologies showed that the SBS test produced significantly lower bond strength values than the push-out test, was skilful in determining the adhesion of AH Plus sealer to dentin and gutta-percha, and required specimens that could be easily prepared for SEM, presenting as a viable alternative for further experiments.


Journal of Endodontics | 2004

Influence of Ultrasound, With and Without Water Spray Cooling, on Removal of Posts Cemented With Resin or Zinc Phosphate Cements

Ângela Delfina Bittencourt Garrido; Tabajara Sabbag Fonseca; Edson Alfredo; Yara Teresinha Corrêa Silva-Sousa; Manoel Damião Sousa-Neto

The efficacy of ultrasound, with and without water spray, was evaluated in vitro on the amount of force necessary to dislodge posts cemented with resin or zinc phosphate. Forty-two samples were divided into six groups: groups 1, 2, and 3, posts cemented with zinc phosphate; groups 4, 5, and 6, posts cemented with resin (Panavia F); groups 1 and 4 (controls), no ultrasound; groups 2 and 5, ultrasound without water spray; and groups 3 and 6, ultrasound with water spray. The Instron testing machine was used. Ultrasound without water spray significantly reduced (71%) the force necessary to displace posts cemented with Panavia F (p < 0.01); however, this value was similar to the efficacy of ultrasound with water spray for posts cemented with zinc phosphate (reduction of 75%). We conclude that cooling with ultrasound interferes with the force necessary for post removal, depending on the type of cement used.


Brazilian Dental Journal | 2006

Effect of eugenol-based endodontic cement on the adhesion of intraradicular posts

Edson Alfredo; Emanuel Soares de Souza; Melissa Andréia Marchesan; Silvana Maria Paulino; Ricardo Gariba-Silva; Manoel Damião Sousa-Neto

The present study evaluated, in vitro, the influence of an eugenol-based endodontic sealer (EndoFill) on the adhesion of intra-radicular posts cemented with a resin-based cement (Enforce) ou a zinc phosphate cement. Twenty-four single-rooted maxillary canines were divided into 2 groups (n=12) and obturated with either gutta-percha points plus EndoFill or gutta-percha points alone (no cement). In each group, half of intracanal posts (n=6) were cemented with Enforce resin-based cement and half with zinc phosphate cement. Specimens were submitted to pull-out test in an Instron machine and tensile force was applied at a crosshead speed of 0.5 mm/min until post dislodgement. The maximum forces required for post removal was recorded (N) and means were submitted to statistical analysis by Kruskal-Wallis test (p<0.01). Posts cemented with zinc phosphate cement were significantly more retentive (353.4 N) than those cemented with Enforce (134.9 N) (p<0.01). Regarding the influence of the eugenol-based cement (EndoFill) on post retention, there was statistically significant difference (p<0.01) only between the groups cemented with Enforce, i.e., in the canals filled with EndoFill + guta-percha there was lower bond strength than in the canals filled with gutta-percha points alone (101.5 and 168.2 N, respectively). In conclusion, the zinc-phosphate-based cement showed greater post retention than the resin-based cement. The findings of this study suggest that the eugenol-containing sealer interfered with the adhesive properties of the resin-based cement.


Photomedicine and Laser Surgery | 2010

Adhesion of Endodontic Sealers to Human Root Dentine Submitted to Different Surface Treatments

Gisele Aihara Haragushiku; Manoel Damião Sousa-Neto; Yara Teresinha Corrêa Silva-Sousa; Edson Alfredo; Silvio Rocha Corrêa da Silva; Ricardo Gariba Silva

OBJECTIVE To evaluate the adhesion of the endodontic sealers Epiphany, Apexit Plus, and AH Plus to root canal dentin submitted to different surface treatments, by using the push-out test. METHODS One hundred twenty-eight root cylinders obtained from maxillary canines were embedded in acrylic resin, had the canals prepared, and were randomly assigned to four groups (n = 32), according to root dentin treatment: (I) distilled water (control), (II) 17% EDTAC, (III) 1% NaOCl and (IV) Er:YAG laser with 16-Hz, 400-mJ input (240-mJ output) and 0.32-J/cm(2) energy density. Each group was divided into four subgroups (n = 8) filled with Epiphany (either dispensed from the automix syringe supplied by the manufacturer or prepared by hand mixing), Apexit Plus, or AH Plus. Data (MPa) were analyzed by ANOVA and Tukeys test. RESULTS A statistically significant difference (p < 0.01) was found among the root-canal sealers, except for the Epiphany subgroups, which had statistically similar results to each other (p > 0.01): AH Plus (4.77 +/- 0.85), Epiphany/hand mixed (3.06 +/- 1.34), Epiphany/automix syringe (2.68 +/- 1.35), and Apexit Plus (1.22 +/- 0.33). A significant difference (p < 0.01) was found among the dentin surface treatments. The highest adhesion values were obtained with AH Plus when root dentin was treated with Er:YAG laser and 17% EDTAC. Epiphany sealer presented the lowest adhesion values to root dentin treated with 17% EDTAC. CONCLUSIONS The resin-based sealers had different adhesive behaviors, depending on the treatment of root canal walls. The mode of preparation of Epiphany (automix syringe or hand mixing) did not influence sealer adhesion to root dentin.


Journal of Applied Oral Science | 2009

Effect of eugenol-based endodontic sealer on the adhesion of intraradicular posts cemented after different periods

Larissa Lustosa Lima Dias; Alessandro Rogério Giovani; Yara T. Corrêa Silva Sousa; Luiz Pascoal Vansan; Edson Alfredo; Manoel Damião Sousa-Neto; Silvana Maria Paulino

Objective: This study evaluated in vitro the influence of an eugenol-based sealer (EndoFill) on the retention of stainless steel prefabricated posts cemented with zinc phosphate and resin-based (Panavia F) cements after different periods of root canal obturation, using the pull-out test. Material and methods: Sixty upper canines were decoronated and the roots were embedded in resin blocks. The specimens were distributed into 3 groups, according to the period elapsed between canal obturation and post cementation: Group I - immediately; Group II - 72 h and Group III - 4 months. The groups were subdivided according to the type of cement used for post cementation: A - zinc phosphate and B - Panavia F. Following the experimental periods, specimens were subjected to pull- out test in an Instron machine with application of tensile force at a crosshead speed of 0.5 mm/min until post dislodgement. The maximum forces required for post removal were recorded (kN) and means were subjected to statistical analysis by 2-way ANOVA and Tukey-Kramer test (α=0.001) Results: There were statistically significant differences (p<0.01) between the posts cemented with zinc phosphate cement (0.2112 kN) and Panavia F (0.0501 kN). However, no statistically significant differences (p>0.05) were found between the three post cementation periods, regardless of the cement. Conclusions: It was concluded that the eugenol-based sealer influenced the tensile strength of the posts cemented with the resin cement, but had no influence on the time waited between root canal obturation and post space preparation/post cementation.


Brazilian Dental Journal | 2011

Effect of bleaching protocols with 38% hydrogen peroxide and post-bleaching times on dentin bond strength

Aline Evangelista Souza-Gabriel; Lilian Oliveira Cambaúva Vitussi; Camila Milani; Edson Alfredo; Danielle Cristine Furtado Messias; Yara Teresinha Corrêa Silva-Sousa

This study assessed the effect of bleaching protocols with 38% hydrogen peroxide (HP) and post-bleaching times on shear bond strength of a composite resin to dentin. One-hundred slabs of intracoronary dentin were included and randomly assigned into 2 groups according to the bleaching protocol: HP (2 applications of 10 min each) and HP activated by LED laser (2 applications of 10 min each/45 s of light activation). Groups were subdivided according to the post-bleaching time (n=10): 1 day, 3 days, 7 days, 10 days and 14 days. The control group was unbleached and restored (n=10). The specimens were restored with Single Bond adhesive system/Filtek Z250 resin using a polytetrafluorethylene matrix and were submitted to the shear bond strength testa after 24 h,. Data were analyzed by ANOVA and Tukeys test (α=0.05). Unbleached group (0.283 ± 0.134) had the highest bond strength and was statistically similar (p>0.05) to HP/10 days (0.278 ± 0.064), HP + LED laser/10 days (0.280 ± 0.078), HP/14 days (0.281 ± 0.104), HP + LED laser/14 days (0.277 ± 0.093). Lower bond strength were verified in HP/1 day (0.082 ± 0.012), HP/3 days (0.079 ± 0.013), HP + LED laser/1 day (0.073 ± 0.018) and HP + LED laser/3 days (0.080 ± 0.015), which were statistically similar (p>0.05). HP/7 days (0.184 ± 0.154) and HP + LED laser/7 days (0.169 ± 0.102) had intermediate values (p<0.05). The restorative procedure of intracoronary dentin bleached with 38% HP with or without the use of light source should be performed after at least 10 days after the bleaching treatment.

Collaboration


Dive into the Edson Alfredo's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Manoel D. Sousa Neto

Universidade de Ribeirão Preto

View shared research outputs
Researchain Logo
Decentralizing Knowledge