Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Edward Duncan is active.

Publication


Featured researches published by Edward Duncan.


Journal of the American College of Cardiology | 2013

Inverse Relationship Between Fractionated Electrograms and Atrial Fibrosis in Persistent Atrial Fibrillation: Combined Magnetic Resonance Imaging and High-Density Mapping

Amir S. Jadidi; Hubert Cochet; Ashok J. Shah; Steven J. Kim; Edward Duncan; Shinsuke Miyazaki; Maxime Sermesant; Heiko Lehrmann; Matthieu Lederlin; Nick Linton; Andrei Forclaz; Isabelle Nault; Lena Rivard; Matthew Wright; Xingpeng Liu; Daniel Scherr; Stephen B. Wilton; Laurent Roten; Patrizio Pascale; Nicolas Derval; Frederic Sacher; Sébastien Knecht; Cornelius Keyl; Mélèze Hocini; Michel Montaudon; François Laurent; Michel Haïssaguerre; Pierre Jaïs

OBJECTIVES This study sought to evaluate the relationship between fibrosis imaged by delayed-enhancement (DE) magnetic resonance imaging (MRI) and atrial electrograms (Egms) in persistent atrial fibrillation (AF). BACKGROUND Atrial fractionated Egms are strongly related to slow anisotropic conduction. Their relationship to atrial fibrosis has not yet been investigated. METHODS Atrial high-resolution MRI of 18 patients with persistent AF (11 long-lasting persistent AF) was registered with mapping geometry (NavX electro-anatomical system (version 8.0, St. Jude Medical, St. Paul, Minnesota)). DE areas were categorized as dense or patchy, depending on their DE content. Left atrial Egms during AF were acquired using a high-density, 20-pole catheter (514 ± 77 sites/map). Fractionation, organization/regularity, local mean cycle length (CL), and voltage were analyzed with regard to DE. RESULTS Patients with long-lasting persistent versus persistent AF had larger left atrial (LA) surface area (134 ± 38 cm(2) vs. 98 ± 9 cm(2), p = 0.02), a higher amount of atrial DE (70 ± 16 cm(2) vs. 49 ± 10 cm(2), p = 0.01), more complex fractionated atrial Egm (CFAE) extent (54 ± 16 cm(2) vs. 28 ± 15 cm(2), p = 0.02), and a shorter baseline AF CL (147 ± 10 ms vs. 182 ± 14 ms, p = 0.01). Continuous CFAE (CFEmean [NavX algorithm that quantifies Egm fractionation] <80 ms) occupied 38 ± 19% of total LA surface area. Dense DE was detected at the left posterior left atrium. In contrast, the right posterior left atrium contained predominantly patchy DE. Most CFAE (48 ± 14%) occurred at non-DE LA sites, followed by 41 ± 12% CFAE at patchy DE and 11 ± 6% at dense DE regions (p = 0.005 and p = 0.008, respectively); 19 ± 6% CFAE sites occurred at border zones of dense DE. Egms were less fractionated, with longer CL and lower voltage at dense DE versus non-DE regions: CFEmean: 97 ms versus 76 ms, p < 0.0001; local CL: 153 ms versus 143 ms, p < 0.0001; mean voltage: 0.63 mV versus 0.86 mV, p < 0.0001. CONCLUSIONS Atrial fibrosis as defined by DE MRI is associated with slower and more organized electrical activity but with lower voltage than healthy atrial areas. Ninety percent of continuous CFAE sites occur at non-DE and patchy DE LA sites. These findings are important when choosing the ablation strategy in persistent AF.


Circulation-arrhythmia and Electrophysiology | 2014

A Randomized Controlled Trial of Catheter Ablation Versus Medical Treatment of Atrial Fibrillation in Heart Failure (The CAMTAF Trial)

Ross J. Hunter; T J Berriman; Ihab Diab; Ravindu Kamdar; Laura Richmond; Victoria Baker; Farai Goromonzi; Vinit Sawhney; Edward Duncan; Stephen P. Page; Waqas Ullah; Beth Unsworth; J Mayet; Mehul Dhinoja; Mark J. Earley; Simon Sporton; Richard J. Schilling

Background—Restoring sinus rhythm in patients with heart failure (HF) and atrial fibrillation (AF) may improve left ventricular (LV) function and HF symptoms. We sought to compare the effect of a catheter ablation strategy with that of a medical rate control strategy in patients with persistent AF and HF. Methods and Results—Patients with persistent AF, symptomatic HF, and LV ejection fraction <50% were randomized to catheter ablation or medical rate control. The primary end-point was the difference between groups in LV ejection fraction at 6 months. Baseline LV ejection fraction was 32±8% in the ablation group and 34±12% in the medical group. Twenty-six patients underwent catheter ablation, and 24 patients were rate controlled. Freedom from AF was achieved in 21/26 (81%) at 6 months off antiarrhythmic drugs. LV ejection fraction at 6 months in the ablation group was 40±12% compared with 31±13% in the rate control group (P=0.015). Ablation was associated with better peak oxygen consumption (22±6 versus 18±6 mL/kg per minute; P=0.014) and Minnesota living with HF questionnaire score (24±22 versus 47±22; P=0.001) compared with rate control. Conclusions—Catheter ablation is effective in restoring sinus rhythm in selected patients with persistent AF and HF, and can improve LV function, functional capacity, and HF symptoms compared with rate control. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT01411371


Circulation-arrhythmia and Electrophysiology | 2012

Functional Nature of Electrogram Fractionation Demonstrated by Left Atrial High Density Mapping

Amir S. Jadidi; Edward Duncan; Shinsuke Miyazaki; Nicolas Lellouche; Ashok J. Shah; Andrei Forclaz; Isabelle Nault; Matthew Wright; Lena Rivard; Xingpeng Liu; Daniel Scherr; Stephen B. Wilton; Frederic Sacher; Nicolas Derval; Sébastien Knecht; Steven J. Kim; Mélèze Hocini; Sanjiv M. Narayan; Michel Haïssaguerre; Pierre Jaïs

Background— Complex fractionated atrial electrograms (CFAE) are targets of atrial fibrillation (AF) ablation. Serial high-density maps were evaluated to understand the impact of activation direction and rate on electrogram (EGM) fractionation. Methods and Results— Eighteen patients (9 persistent) underwent high-density, 3-dimensional, left-atrial mapping (>400 points/map) during AF, sinus (SR), and CS-paced (CSp) rhythms. In SR and CSp, fractionation was defined as an EGM with ≥4 deflections, although, in AF, CFE-mean <80 ms was considered as continuous CFAE. The anatomic distribution of CFAE sites was assessed, quantified, and correlated between rhythms. Mechanisms underlying fractionation were investigated by analysis of voltage, activation, and propagation maps. A minority of continuous CFAE sites displayed EGM fractionation in SR (15+/−4%) and CSp (12+/−8%). EGM fractionation did not match between SR and CSp at 70+/−10% sites. Activation maps in SR and CSp showed that wave collision (71%) and regional slow conduction (24%) caused EGM fractionation. EGM voltage during AF (0.59+/−0.58 mV) was lower than during SR and CSp (>1.0 mV) at all sites. During AF, the EGM voltage was higher at continuous CFAE sites than at non-CFAE sites (0.53 mV (Q1, Q3: 0.33 to 0.83) versus 0.30 mV (Q1, Q3: 0.18 to 0.515), P<0.00001). Global LA voltage in AF was lower in patients with persistent AF versus patients with paroxysmal AF (0.6+/−0.59 mV versus 1.12+/−1.32 mV, P<0.01). Conclusions— The distribution of fractionated EGMs is highly variable, depending on direction and rate of activation (SR versus CSp versus AF). Fractionation in SR and CSp rhythms mostly resulted from wave collision. All sites with continuous fractionation in AF displayed normal voltage in SR, suggesting absence of structural scar. Thus, many fractionated EGMs are functional in nature, and their sites dynamic.


Circulation-arrhythmia and Electrophysiology | 2014

Catheter Ablation of Atrial Fibrillation in Patients With Left Ventricular Systolic Dysfunction A Systematic Review and Meta-Analysis

Matteo Anselmino; Mario Matta; Fabrizio D'Ascenzo; T. Jared Bunch; Richard J. Schilling; Ross J. Hunter; Carlo Pappone; Thomas Neumann; Georg Noelker; Martin Fiala; Emanuele Bertaglia; Antonio Frontera; Edward Duncan; C. Nalliah; Pierre Jaïs; Rukshen Weerasooriya; Jon M. Kalman; Fiorenzo Gaita

Background—Catheter ablation of atrial fibrillation (AFCA) is an established therapeutic option for rhythm control in symptomatic patients. Its efficacy and safety among patients with left ventricular systolic dysfunction is based on small populations, and data concerning long-term outcome are limited. We performed this meta-analysis to assess safety and long-term outcome of AFCA in patients with left ventricular systolic dysfunction, to evaluate predictors of recurrence and impact on left ventricular function. Methods and Results—A systematic review was conducted in MEDLINE/PubMed and Cochrane Library. Randomized controlled trials, clinical trials, and observational studies including patients with left ventricular systolic dysfunction undergoing AFCA were included. Twenty-six studies were selected, including 1838 patients. Mean follow-up was 23 (95% confidence interval, 18–40) months. Overall complication rate was 4.2% (3.6%–4.8%). Efficacy in maintaining sinus rhythm at follow-up end was 60% (54%–67%). Meta-regression analysis revealed that time since first atrial fibrillation (P=0.030) and heart failure (P=0.045) diagnosis related to higher, whereas absence of known structural heart disease (P=0.003) to lower incidence of atrial fibrillation recurrences. Left ventricular ejection fraction improved significantly during follow-up by 13% (P<0.001), with a significant reduction of patients presenting an ejection fraction <35% (P<0.001). N-terminal pro-brain natriuretic peptide blood levels decreased by 620 pg/mL (P<0.001). Conclusions—AFCA efficacy in patients with impaired left ventricular systolic function improves when performed early in the natural history of atrial fibrillation and heart failure. AFCA provides long-term benefits on left ventricular function, significantly reducing the number of patients with severely impaired systolic function.


Heart | 2010

Long-term efficacy of catheter ablation for atrial fibrillation: impact of additional targeting of fractionated electrograms

Ross J. Hunter; T J Berriman; I Diab; Victoria Baker; Malcolm Finlay; Laura Richmond; Edward Duncan; Ravindu Kamdar; Glyn Thomas; Dominic Abrams; M Dhinoja; Simon Sporton; Mj Earley; Richard J. Schilling

Objectives To investigate long-term efficacy of catheter ablation for atrial fibrillation (AF) and the impact of ablating complex or fractionated electrograms (CFEs) in addition to pulmonary vein isolation and linear lesions in persistent AF (PeAF). Methods Consecutive cases from 2002–2007 were analysed. All the patients underwent a wide-area circumferential ablation with confirmation of electrical isolation. For PeAF, linear lesions were added, with additional targeting of CFE from 2005. Data were collected in a prospective database. Attempts were made to contact all patients for follow-up. Results 285 patients underwent 530 procedures. The mean (SD) age was 57 (11) years, 75% were male, 20% had structural heart disease and 53% had paroxysmal AF (PAF). The mean number of procedures was 1.9 per patient (1.7 for PAF and 2.0 for PeAF). Procedural complications included stroke or transient ischemic attack in 0.6% and pericardial effusion requiring drainage in 1.7%. During 2.7 years (0.2 to 7.4 years) of follow-up from the last procedure, there were seven deaths (unrelated to their ablation or AF) and three strokes or transient ischemic attack (0.3% per year). Freedom from AF/atrial tachyarrhythmia was 86% for PAF and 68% for PeAF. Late recurrence was 3 per 100 years of follow-up after >3 years. The Kaplan–Meier analysis showed that CFE ablation improved the outcome for PeAF after the first cluster of procedures (p=0.049), with a trend towards improved final outcome (p=0.130). Conclusions Long-term freedom from AF is achievable in most patients with PAF and PeAF with low rates of late recurrence. Additional targeting of CFE improves outcome for PeAF. Late adverse events including stroke are few.


Journal of Cardiovascular Electrophysiology | 2015

Point-by-Point Radiofrequency Ablation Versus the Cryoballoon or a Novel Combined Approach: A Randomized Trial Comparing 3 Methods of Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation (The Cryo Versus RF Trial).

Ross J. Hunter; Victoria Baker; Malcolm Finlay; Edward Duncan; Matthew J. Lovell; Muzahir H. Tayebjee; Waqas Ullah; M. Shoaib Siddiqui; Ailsa McLean; Laura Richmond; Claire Kirkby; Matthew Ginks; Mehul Dhinoja; Simon Sporton; Mark J. Earley; Richard J. Schilling

Catheter ablation of paroxysmal AF using the Cryoballoon (CRYO) has yielded similar success rates to conventional wide encirclement using radiofrequency catheter ablation (RFCA), but randomized data are lacking. Pilot data suggested a high success rate with a combined approach (COMBINED) using wide encirclement with RFCA followed by 2 CRYO applications to each vein. We compared these 3 strategies in a randomized controlled trial.


Europace | 2016

Catheter ablation of atrial fibrillation in patients with heart failure: impact of maintaining sinus rhythm on heart failure status and long-term rates of stroke and death

Waqas Ullah; Liang-Han Ling; S. Prabhu; Geoffrey Lee; Peter M. Kistler; Malcolm Finlay; Mark J. Earley; Simon Sporton; Yaver Bashir; Timothy R. Betts; Kim Rajappan; Glyn Thomas; Edward Duncan; Andrew Staniforth; Ian Mann; Anthony Chow; Pier Lambiase; Richard J. Schilling; Ross J. Hunter

AIMS Catheter ablation of atrial fibrillation (AF) in patients with heart failure (HF) can improve left ventricular (LV) function and HF symptoms. We aimed to investigate whether long-term maintenance of sinus rhythm impacts on hard outcomes such as stroke and death. METHODS AND RESULTS An international multicentre registry was compiled from seven centres for consecutive patients undergoing catheter ablation of AF. Long-term freedom from AF was examined in patients with and without HF. The impact of maintaining sinus rhythm on rates of stroke and death was also examined. A total of 1273 patients were included: 171 with HF and 1102 without. Median follow-up was 3.1 years (IQR 2.0-4.3). The final procedure success rate was no different for paroxysmal AF (PAF) (78.7 vs. 85.7%, P = 0.186), but significantly different for persistent AF (57.3 vs. 75.8%, P < 0.001). Multivariate analysis showed that HF independently predicted recurrent arrhythmia [hazard ratio (HR) 1.7, 95% confidence interval (CI) 1.2-2.4, P = 0.002]. New York Heart Association class decreased from 2.3 ± 0.7 at baseline to 1.5 ± 0.8 at follow-up (P < 0.001). Left ventricular ejection fraction (LVEF) increased from 34.3 ± 9.0 to 45.8 ± 12.8% (P < 0.001). Recurrent AF was strongly predictive of stroke or death in HF patients (HR 8.33, 95% CI 1.86-37.7, P = 0.001). CONCLUSION Long-term success rates for persistent (but not paroxysmal) AF ablation are significantly lower in HF patients. Left ventricular function and HF symptoms were improved following ablation. In HF patients, recurrent arrhythmia strongly predicted stroke and death during follow-up.


Journal of Cardiovascular Electrophysiology | 2010

Uninterrupted Warfarin for Periprocedural Anticoagulation in Catheter Ablation of Typical Atrial Flutter: A Safe and Cost‐Effective Strategy

Malcolm Finlay; Vinit Sawhney; Richard J. Schilling; Glyn Thomas; Edward Duncan; Ross J. Hunter; Gurpreet Virdi; Dominic Abrams; Simon Sporton; Mehul Dhinoja; Mark J. Earley

Uninterrupted Warfarin for Periprocedural Anticoagulation in Catheter Ablation of Typical Atrial Flutter. Introduction: Many patients undergoing catheter ablation of atrial flutter (AFL) require periprocedural anticoagulation. We compared a strategy of conversion to low molecular weight heparin (LMWH) periprocedure to uninterrupted warfarinization in a nonrandomized, case‐controlled study.


Europace | 2016

Cardiac resynchronization therapy: mechanisms of action and scope for further improvement in cardiac function

Siana Jones; Joost Lumens; S.M. Afzal Sohaib; Judith A. Finegold; Prapa Kanagaratnam; Mark Tanner; Edward Duncan; Philip Moore; Francisco Leyva; Mike Frenneaux; Mark Mason; Alun D. Hughes; Darrel P. Francis; Zachary I. Whinnett

Abstract Aims Cardiac resynchronization therapy (CRT) may exert its beneficial haemodynamic effect by improving ventricular synchrony and improving atrioventricular (AV) timing. The aim of this study was to establish the relative importance of the mechanisms through which CRT improves cardiac function and explore the potential for additional improvements with improved ventricular resynchronization. Methods and Results We performed simulations using the CircAdapt haemodynamic model and performed haemodynamic measurements while adjusting AV delay, at low and high heart rates, in 87 patients with CRT devices. We assessed QRS duration, presence of fusion, and haemodynamic response. The simulations suggest that intrinsic PR interval and the magnitude of reduction in ventricular activation determine the relative importance of the mechanisms of benefit. For example, if PR interval is 201 ms and LV activation time is reduced by 25 ms (typical for current CRT methods), then AV delay optimization is responsible for 69% of overall improvement. Reducing LV activation time by an additional 25 ms produced an additional 2.6 mmHg increase in blood pressure (30% of effect size observed with current CRT). In the clinical population, ventricular fusion significantly shortened QRS duration (Δ-27 ± 23 ms, P < 0.001) and improved systolic blood pressure (mean 2.5 mmHg increase). Ventricular fusion was present in 69% of patients, yet in 40% of patients with fusion, shortening AV delay (to a delay where fusion was not present) produced the optimal haemodynamic response. Conclusions Improving LV preloading by shortening AV delay is an important mechanism through which cardiac function is improved with CRT. There is substantial scope for further improvement if methods for delivering more efficient ventricular resynchronization can be developed. Clinical Trial Registration Our clinical data were obtained from a subpopulation of the British Randomised Controlled Trial of AV and VV Optimisation (BRAVO), which is a registered clinical trial with unique identifier: NCT01258829, https://clinicaltrials.gov


Pacing and Clinical Electrophysiology | 2015

Clinical Predictors of Pacemaker Implantation in Patients with Syncope Receiving Implantable Loop Recorder with or without ECG Conduction Abnormalities.

Nauman Ahmed; Antonio Frontera; Alexander Carpenter; Stafenia Cataldo; Georgia May Connolly; Matteo Fasiolo; Tim Cripps; Glyn Thomas; Ihab Diab; Edward Duncan

Implantable loop recorders (ILR) allow prolonged cardiac rhythm monitoring and improved diagnostic yield in syncope patients. Predictive factors for pacemaker (PM) implantation in the ILR population with unexplained syncope have not been adequately investigated. In this single center, retrospective, observational study we investigated factors that predict PM implantation in this population.

Collaboration


Dive into the Edward Duncan's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Glyn Thomas

St Bartholomew's Hospital

View shared research outputs
Top Co-Authors

Avatar

Ross J. Hunter

St Bartholomew's Hospital

View shared research outputs
Top Co-Authors

Avatar

Simon Sporton

St Bartholomew's Hospital

View shared research outputs
Top Co-Authors

Avatar

Mark J. Earley

St Bartholomew's Hospital

View shared research outputs
Top Co-Authors

Avatar

Victoria Baker

St Bartholomew's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Ihab Diab

St Bartholomew's Hospital

View shared research outputs
Top Co-Authors

Avatar

Laura Richmond

St Bartholomew's Hospital

View shared research outputs
Top Co-Authors

Avatar

Malcolm Finlay

St Bartholomew's Hospital

View shared research outputs
Researchain Logo
Decentralizing Knowledge