Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Edward E. Domning is active.

Publication


Featured researches published by Edward E. Domning.


Review of Scientific Instruments | 2009

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

Martin Kunz; Nobumichi Tamura; Kai Chen; Alastair A. MacDowell; Richard Celestre; Matthew Church; Sirine C. Fakra; Edward E. Domning; James M. Glossinger; Jonathan L. Kirschman; Gregory Y. Morrison; Dave W. Plate; Brian V. Smith; Tony Warwick; Valeriy V. Yashchuk; Howard A. Padmore; Ersan Üstündag

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 microm spot of approximately 5x10(9) photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 microm are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution (approximately 0.2 microm) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10(-5) strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution (approximately 150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.


Journal of Synchrotron Radiation | 2005

A BEAMLINE FOR HIGH PRESSURE STUDIES AT THE ADVANCED LIGHT SOURCE WITH A SUPERCONDUCTING BENDING MAGNET AS THE SOURCE

Martin Kunz; Alastair A. MacDowell; Wendel A. Caldwell; Daniella Cambie; Richard Celestre; Edward E. Domning; Robert M. Duarte; A. E. Gleason; James M. Glossinger; Nicholas Kelez; D. Plate; Tony Yu; Joeseph M. Zaug; Howard A. Padmore; Raymond Jeanloz; A. Paul Alivisatos; Simon M. Clark

A new facility for high-pressure diffraction and spectroscopy using diamond anvil high-pressure cells has been built at the Advanced Light Source on beamline 12.2.2. This beamline benefits from the hard X-radiation generated by a 6 T superconducting bending magnet (superbend). Useful X-ray flux is available between 5 keV and 35 keV. The radiation is transferred from the superbend to the experimental enclosure by the brightness-preserving optics of the beamline. These optics are comprised of a plane parabola collimating mirror, followed by a Kohzu monochromator vessel with Si(111) crystals (E/DeltaE approximately equal 7000) and W/B4C multilayers (E/DeltaE approximately equal 100), and then a toroidal focusing mirror with variable focusing distance. The experimental enclosure contains an automated beam-positioning system, a set of slits, ion chambers, the sample positioning goniometry and area detector (CCD or image-plate detector). Future developments aim at the installation of a second endstation dedicated to in situ laser heating and a dedicated high-pressure single-crystal station, applying both monochromatic and polychromatic techniques.


Journal of Synchrotron Radiation | 2004

Suite of three protein crystallography beamlines with single superconducting bend magnet as the source.

Alastair A. MacDowell; Richard Celestre; Malcolm R. Howells; Wayne R. McKinney; James Krupnick; Daniella Cambie; Edward E. Domning; Robert M. Duarte; Nicholas Kelez; D. Plate; Carl W. Cork; Thomas Earnest; Jeffery Dickert; George Meigs; Corie Ralston; James M. Holton; Thomas C. Alber; James M. Berger; David A. Agard; Howard A. Padmore

At the Advanced Light Source, three protein crystallography beamlines have been built that use as a source one of the three 6 T single-pole superconducting bending magnets (superbends) that were recently installed in the ring. The use of such single-pole superconducting bend magnets enables the development of a hard X-ray program on a relatively low-energy 1.9 GeV ring without taking up insertion-device straight sections. The source is of relatively low power but, owing to the small electron beam emittance, it has high brightness. X-ray optics are required to preserve the brightness and to match the illumination requirements for protein crystallography. This was achieved by means of a collimating premirror bent to a plane parabola, a double-crystal monochromator followed by a toroidal mirror that focuses in the horizontal direction with a 2:1 demagnification. This optical arrangement partially balances aberrations from the collimating and toroidal mirrors such that a tight focused spot size is achieved. The optical properties of the beamline are an excellent match to those required by the small protein crystals that are typically measured. The design and performance of these new beamlines are described.


Review of Scientific Instruments | 2011

Development of a compact fast CCD camera and resonant soft x-ray scattering endstation for time-resolved pump-probe experiments

Dionisio Doering; Yi-De Chuang; Nord Andresen; Ken P. Chow; Devis Contarato; Curtis L. Cummings; Edward E. Domning; John Joseph; J. S. Pepper; Brian V. Smith; G.J. Zizka; C. Ford; Wei-Sheng Lee; M. Weaver; L. Patthey; John Weizeorick; Z. Hussain; Peter Denes

The designs of a compact, fast CCD (cFCCD) camera, together with a resonant soft x-ray scattering endstation, are presented. The cFCCD camera consists of a highly parallel, custom, thick, high-resistivity CCD, readout by a custom 16-channel application specific integrated circuit to reach the maximum readout rate of 200 frames per second. The camera is mounted on a virtual-axis flip stage inside the RSXS chamber. When this flip stage is coupled to a differentially pumped rotary seal, the detector assembly can rotate about 100°/360° in the vertical/horizontal scattering planes. With a six-degrees-of-freedom cryogenic sample goniometer, this endstation has the capability to detect the superlattice reflections from the electronic orderings showing up in the lower hemisphere. The complete system has been tested at the Advanced Light Source, Lawrence Berkeley National Laboratory, and has been used in multiple experiments at the Linac Coherent Light Source, SLAC National Accelerator Laboratory.


Proceedings of SPIE | 2008

Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory

Jonathan L. Kirschman; Edward E. Domning; Wayne R. McKinney; Gregory Y. Morrison; Brian V. Smith; Valeriy V. Yashchuk

The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the stage, and analysis of the performance by a slope measurement of a highly curved super-quality substrate with less than 0.3 microradian (rms) slope variation.


Optical Engineering | 2013

Methodology for Optimal In Situ Alignment and Setting of Bendable Optics for Diffraction-Limited Focusing of Soft X-Rays

Daniel J. Merthe; Valeriy V. Yashchuk; Kenneth A. Goldberg; Martin Kunz; Nobumichi Tamura; Wayne R. McKinney; Nikolay A. Artemiev; Richard Celestre; Gregory Y. Morrison; Erik H. Anderson; Brian V. Smith; Edward E. Domning; Senajith Rekawa; Howard A. Padmore

Abstract. We demonstrate a comprehensive and broadly applicable methodology for the optimal in situ configuration of bendable soft x-ray Kirkpatrick-Baez mirrors. The mirrors used for this application are preset at the Advanced Light Source Optical Metrology Laboratory prior to beamline installation. The in situ methodology consists of a new technique for simultaneously setting the height and pitch angle of each mirror. The benders of both mirrors were then optimally tuned in order to minimize ray aberrations to a level below the diffraction-limited beam waist size of 200  nm (horizontal)×100  nm (vertical). After applying this methodology, we measured a beam waist size of 290  nm (horizontal)×130  nm (vertical) with 1 nm light using the Foucault knife-edge test. We also discuss the utility of using a grating-based lateral shearing interferometer with quantitative wavefront feedback for further improvement of bendable optics.


Proceedings of SPIE | 2011

Automated suppression of errors in LTP-II slope measurements with x-ray optics

Zulfiqar Ali; Nikolay A. Artemiev; Curtis L. Cummings; Edward E. Domning; Nicholas Kelez; Wayne R. McKinney; Daniel J. Merthe; Gregory Y. Morrison; Brian V. Smith; Valeriy V. Yashchuk

Systematic error and instrumental drift are the major limiting factors of sub-microradian slope metrology with state-of-the-art x-ray optics. Significant suppression of the errors can be achieved by using an optimal measurement strategy suggested in [Rev. Sci. Instrum. 80, 115101 (2009)]. Here, we report on development of an automated, kinematic, rotational system that provides fully controlled flipping, tilting, and shifting of a surface under test. The system is to be integrated into the Advanced Light Source long trace profiler, LTP-II, allowing for complete realization of the advantages of the optimal measurement strategy method. We describe in detail the systems specification, design operational control and data acquisition. The performance of the system is demonstrated via the results of high precision measurements with a number of super-polished mirrors.


Proceedings of SPIE | 2007

Flat-field calibration of CCD detector for Long Trace Profiler

Jonathan L. Kirschman; Edward E. Domning; Keith D. Franck; Steven C. Irick; Alastair A. MacDowell; Wayne R. McKinney; Gregory Y. Morrison; Brian V. Smith; Tony Warwick; Valeriy V. Yashchuk

The next generation of synchrotrons and free electron lasers requires x-ray optical systems with extremely high-performance, generally, of diffraction limited quality. Fabrication and use of such optics requires highly accurate metrology. In the present paper, we discuss a way to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used at synchrotron facilities to characterize x-ray optics at high-spatial-wavelengths from approximately 2 mm to 1 m. One of the major sources of LTP systematic error is the detector. For optimal functionality, the detector has to possess the smallest possible pixel size/spacing, a fast method of shuttering, and minimal nonuniformity of pixel-to-pixel photoresponse. While the first two requirements are determined by choice of detector, the non-uniformity of photoresponse of typical detectors such as CCD cameras is around 2-3%. We describe a flat-field calibration setup specially developed for calibration of CCD camera photo-response and dark current with an accuracy of better than 0.5%. Such accuracy is adequate for use of a camera as a detector for an LTP with performance of ~0.1 microradian (rms). We also present the design details of the calibration system and results of calibration of a DALSA CCD camera used for upgrading our LTP-II instrument at the ALS Optical Metrology Laboratory.


Review of Scientific Instruments | 2017

Modular soft x-ray spectrometer for applications in energy sciences and quantum materials

Y.-D. Chuang; Yu Cheng Shao; Alejandro Cruz; Kelly Hanzel; Adam Brown; Alex Frano; Ruimin Qiao; Brian Smith; Edward E. Domning; Shih Wen Huang; L. Andrew Wray; Wei Sheng Lee; Zhi-Xun Shen; T. P. Devereaux; Jaw Wern Chiou; Way Faung Pong; Valeriy V. Yashchuk; Eric M. Gullikson; Ruben Reininger; Wanli Yang; Jinghua Guo; Robert M. Duarte; Z. Hussain

Over the past decade, the advances in grating-based soft X-ray spectrometers have revolutionized the soft X-ray spectroscopies in materials research. However, these novel spectrometers are mostly dedicated designs, which cannot be easily adopted for applications with diverging demands. Here we present a versatile spectrometer design concept based on the Hettrick-Underwood optical scheme that uses modular mechanical components. The spectrometers optics chamber can be used with gratings operated in either inside or outside orders, and the detector assembly can be reconfigured accordingly. The spectrometer can be designed to have high spectral resolution, exceeding 10 000 resolving power when using small source (∼1μm) and detector pixels (∼5μm) with high line density gratings (∼3000 lines/mm), or high throughput at moderate resolution. We report two such spectrometers with slightly different design goals and optical parameters in this paper. We show that the spectrometer with high throughput and large energy window is particularly useful for studying the sustainable energy materials. We demonstrate that the extensive resonant inelastic X-ray scattering (RIXS) map of battery cathode material LiNi1/3Co1/3Mn1/3O2 can be produced in few hours using such a spectrometer. Unlike analyzing only a handful of RIXS spectra taken at selected excitation photon energies across the elemental absorption edges to determine various spectral features like the localized dd excitations and non-resonant fluorescence emissions, these features can be easily identified in the RIXS maps. Studying such RIXS maps could reveal novel transition metal redox in battery compounds that are sometimes hard to be unambiguously identified in X-ray absorption and emission spectra. We propose that this modular spectrometer design can serve as the platform for further customization to meet specific scientific demands.


Proceedings of SPIE | 2010

At-wavelength optical metrology development at the ALS

Sheng Sam Yuan; Kenneth A. Goldberg; Valeriy V. Yashchuk; Richard Celestre; Iacopo Mochi; James Macdougall; Gregory Y. Morrison; Brian V. Smith; Edward E. Domning; Wayne R. McKinney; Tony Warwick

Nano-focusing and brightness preservation for ever brighter synchrotron radiation and free electron laser beamlines require surface slope tolerances of x-ray optics on the order of 100 nrad. While the accuracy of fabrication and ex situ metrology of x-ray mirrors has improved over time, beamline in situ performance of the optics is often limited by application specific factors such as x-ray beam heat loading, temperature drift, alignment, vibration, etc. In the present work, we discuss the recent results from the Advanced Light Source developing high accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad accuracy surface slope measurements with reflecting x-ray optics. The techniques will ultimately allow closed-loop feedback systems to be implemented for x-ray nano-focusing. In addition, we present a dedicated metrology beamline endstation, applicable to a wide range of in situ metrology and test experiments. The design and performance of a bendable Kirkpatrick-Baez (KB) mirror with active temperature stabilization will also be presented. The mirror is currently used to study, refine, and optimize in situ mirror alignment, bending and metrology methods essential for nano-focusing application.

Collaboration


Dive into the Edward E. Domning's collaboration.

Top Co-Authors

Avatar

Brian V. Smith

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Valeriy V. Yashchuk

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Gregory Y. Morrison

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Wayne R. McKinney

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Richard Celestre

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Howard A. Padmore

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Alastair A. MacDowell

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Daniel J. Merthe

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Jonathan L. Kirschman

Lawrence Berkeley National Laboratory

View shared research outputs
Top Co-Authors

Avatar

Martin Kunz

Lawrence Berkeley National Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge