Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Eike Rietzel is active.

Publication


Featured researches published by Eike Rietzel.


Medical Physics | 2004

4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Tinsu Pan; Ting Yim Lee; Eike Rietzel; George T.Y. Chen

We propose a new scanning protocol for generating 4D-CT image data sets influenced by respiratory motion. A cine scanning protocol is used during data acquisition, and two registration methods are used to sort images into temporal phases. A volume is imaged in multiple acquisitions of 1 or 2 cm length along the cranial-caudal direction. In each acquisition, the scans are continuously acquired for a time interval greater than or equal to the average respiratory cycle plus the duration of the data for an image reconstruction. The x ray is turned off during CT table translation and the acquisition is repeated until the prescribed volume is completely scanned. The scanning for 20 cm coverage takes about 1 min with an eight-slice CT or 2 mins with a four-slice CT. After data acquisition, the CT data are registered into respiratory phases based on either an internal anatomical match or an external respiratory signal. The internal approach registers the data according to correlation of anatomy in the CT images between two adjacent locations in consecutive respiratory cycles. We have demonstrated the technique with ROIs placed in the region of diaphragm. The external approach registers the image data according to an externally recorded respiratory signal generated by the Real-Time Position Management (RPM) Respiratory Gating System (Varian Medical Systems, Palo Alto, CA). Compared with previously reported prospective or retrospective imaging of the respiratory motion with a single-slice or multi-slice CT, the 4D-CT method proposed here provides (1) a shorter scan time of three to six times faster than the single-slice CT with prospective gating; (2) a shorter scan time of two to four times improvement over a previously reported multi-slice CT implementation, and (3) images over all phases of a breathing cycle. We have applied the scanning and registration methods on phantom, animal and patients, and initial results suggest the applicability of both the scanning and the registration methods.


Medical Physics | 2005

Four‐dimensional computed tomography: Image formation and clinical protocol

Eike Rietzel; Tinsu Pan; George T.Y. Chen

Respiratory motion can introduce significant errors in radiotherapy. Conventional CT scans as commonly used for treatment planning can include severe motion artifacts that result from interplay effects between the advancing scan plane and object motion. To explicitly include organ/target motion in treatment planning and delivery, time-resolved CT data acquisition (4D Computed Tomography) is needed. 4DCT can be accomplished by oversampled CT data acquisition at each slice. During several CT tube rotations projection data are collected in axial cine mode for the duration of the patients respiratory cycle (plus the time needed for a full CT gantry rotation). Multiple images are then reconstructed per slice that are evenly distributed over the acquisition time. Each of these images represents a different anatomical state during a respiratory cycle. After data acquisition at one couch position is completed, x rays are turned off and the couch advances to begin data acquisition again until full coverage of the scan length has been obtained. Concurrent to CT data acquisition the patients abdominal surface motion is recorded in precise temporal correlation. To obtain CT volumes at different respiratory states, reconstructed images are sorted into different spatio-temporally coherent volumes based on respiratory phase as obtained from the patients surface motion. During binning, phase tolerances are chosen to obtain complete volumetric information since images at different couch positions are reconstructed at different respiratory phases. We describe 4DCT image formation and associated experiments that characterize the properties of 4DCT. Residual motion artifacts remain due to partial projection effects. Temporal coherence within resorted 4DCT volumes is dominated by the number of reconstructed images per slice. The more images are reconstructed, the smaller phase tolerances can be for retrospective sorting. From phantom studies a precision of about 2.5 mm for quasiregular motion and typical respiratory periods could be concluded. A protocol for 4DCT scanning was evaluated and clinically implemented at the MGH. Patient data are presented to elucidate how additional patient specific parameters can impact 4DCT imaging.


Physics in Medicine and Biology | 2008

Quantification of interplay effects of scanned particle beams and moving targets.

Christoph Bert; Sven Oliver Grözinger; Eike Rietzel

Scanned particle beams and target motion interfere. This interplay leads to deterioration of the dose distribution. Experiments and a treatment planning study were performed to investigate interplay. Experiments were performed with moving radiographic films for different motion parameters. Resulting dose distributions were analyzed for homogeneity and dose coverage. The treatment planning study was based on the time-resolved computed tomography (4DCT) data of five lung tumor patients. Treatment plans with margins to account for respiratory motion were optimized, and resulting dose distributions for 108 different motion parameters for each patient were calculated. Data analysis for a single fraction was based on dose-volume histograms and the volume covered with 95% of the planned dose. Interplay deteriorated dose conformity and homogeneity (1-standard deviation/mean) in the experiments as well as in the treatment-planning study. The homogeneity on radiographic films was below approximately 80% for motion amplitudes of approximately 15 mm. For the treatment-planning study based on patient data, the target volume receiving at least 95% of the prescribed dose was on average (standard deviation) 71.0% (14.2%). Interplay of scanned particle beams and moving targets has severe impact on the resulting dose distributions. Fractionated treatment delivery potentially mitigates at least parts of these interplay effects. However, especially for small fraction numbers, e.g. hypo-fractionation, treatment of moving targets with scanned particle beams requires motion mitigation techniques such as rescanning, gating, or tracking.


Radiation Oncology | 2007

4D treatment planning for scanned ion beams

Christoph Bert; Eike Rietzel

At Gesellschaft für Schwerionenforschung (GSI) more than 330 patients have been treated with scanned carbon ion beams in a pilot project. To date, only stationary tumors have been treated. In the presence of motion, scanned ion beam therapy is not yet possible because of interplay effects between scanned beam and target motion which can cause severe mis-dosage. We have started a project to treat tumors that are subject to respiratory motion. A prototype beam application system for target tracking with the scanned pencil beam has been developed and commissioned.To facilitate treatment planning for tumors that are subject to organ motion, we have extended our standard treatment planning system TRiP to full 4D functionality. The 4D version of TRiP allows to calculate dose distributions in the presence of motion. Furthermore, for motion mitigation techniques tracking, gating, rescanning, and internal margins optimization of treatment parameters has been implemented. 4D calculations are based on 4D computed tomography data, deformable registration maps, organ motion traces, and beam scanning parameters.We describe the methods of our 4D treatment planning approach and demonstrate functionality of the system for phantom as well as patient data.


Medical Physics | 2006

Improving retrospective sorting of 4D computed tomography data

Eike Rietzel; George T.Y. Chen

Respiratory correlated CT is commercially available, and we have implemented its routine clinical use in planning lung tumor patients. Its value is determined by the fidelity of the spatiotemporal data set after processing the acquired reconstructed slices. Retrospective sorting of reconstructed slices is based on respiratory phase. However, the existing commercial software inadequately models respiratory phase for about 30% of the patients, mainly due to irregularities in the respiratory cycle. We have developed software that improves phase determination and consequently leads to an improvement of retrospective data sorting to make 4DCT data acquisition feasible for routine clinical use. Peak inhalation and exhalation respiratory states are selected manually; intermediate phases are interpolated. Residual motion artifacts in the resulting 4DCT volumes are reduced and allow use of the 4D imaging studies for treatment planning.


Medical Physics | 2006

Deformable registration of 4D computed tomography data.

Eike Rietzel; George T.Y. Chen

Four-dimensional radiotherapy requires deformable registration to track delivered dose across varying anatomical states. Deformable registration based on B-splines was implemented to register 4D computed tomography data to a reference respiratory phase. To assess registration performance, anatomical landmarks were selected across ten respiratory phases in five patients. These point landmarks were transformed according to global registration parameters between different respiratory phases. Registration uncertainties were computed by subtraction of transformed and reference landmark positions. The selection of appropriate registration masks to separate independently moving anatomical subunits is crucial to registration performance. The average registration error for five landmarks for each of five patients was 2.1mm. This level of accuracy is acceptable for most radiotherapy applications.


Physics in Medicine and Biology | 2005

A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode

R Berbeco; Toni Neicu; Eike Rietzel; George T.Y. Chen; S Jiang

Respiratory gating based on external surrogates is performed in many clinics. We have developed a new technique for treatment verification using an electronic portal imaging device (EPID) in cine mode for gated 3D conformal therapy. Implanted radiopaque fiducial markers inside or near the target are required for this technique. The markers are contoured on the planning CT set, enabling us to create digitally reconstructed radiographs (DRRs) for each treatment beam. During the treatment, a sequence of EPID images can be acquired without disrupting the treatment. Implanted markers are visualized in the images and their positions in the beams eye view are calculated off-line and compared to the reference position by matching the field apertures in corresponding EPID and DRR images. The precision of the patient set-up, the placement of the beam-gating window, as well as the residual tumour motion can be assessed for each treatment fraction. This technique has been demonstrated with a case study patient, who had three markers implanted in his liver. For this patient, the intra-fractional variation of all marker positions in the gating window had a 95% range of 4.8 mm in the SI direction (the primary axis of motion). This was about the same (5 mm) as the residual motion considered in the planning process. The inter-fractional variation of the daily mean positions of the markers, which indicates the uncertainty in the set-up procedure, was within +8.3 mm/−4.5 mm (95% range) in the SI direction for this case.


Radiotherapy and Oncology | 2004

Moving targets: detection and tracking of internal organ motion for treatment planning and patient set-up.

Eike Rietzel; Stanley Rosenthal; David P. Gierga; Christopher G. Willett; George T.Y. Chen

BACKGROUND AND PURPOSE Clinical target volumes of the thorax and abdomen are typically expanded to account for inter- and intrafractional organ motion. Usually, such expansions are based on clinical experience and planar observations of target motion during simulation. More precise, 4-dimensional motion margins for a specific patient may improve dose coverage of mobile targets and yet limit unnecessarily large field expansions. We are studying approaches to targeting moving tumors throughout the entire treatment process, from treatment planning to beam delivery. MATERIAL AND METHODS Radio-opaque markers were implanted under CT guidance in the liver at the gross tumor periphery. Organ motion during light respiration was volumetrically imaged by 4D Computed Tomography. Marker motion was also acquired by fluoroscopy and compared with 4DCT data. During treatment, daily diagnostic x-ray images were captured at end-exhale and -inhale for patient setup and target localization. RESULTS Based on the time-resolved CT data, target volumes can be designed to account for respiratory motion during treatment. Motion of the tumor as derived from 4DCT was consistent with fluoroscopic motion analysis. Radiographs acquired in the treatment room enabled millimeter-level patient set-up and assessment of target position relative to bony anatomy. Daily positional variations between bony anatomy and implanted markers were observed. CONCLUSIONS Image guided therapy, based on 4DCT imaging, fluoroscopic imaging studies, and daily gated diagonstic energy set-up radiographs is being developed to improve beam delivery precision. Monitoring internal target motion throughout the entire treatment process will ensure adequate dose coverage of the target while sparing the maximum healthy tissue.


Physics in Medicine and Biology | 2006

Simulations to design an online motion compensation system for scanned particle beams

Sven Oliver Grözinger; Eike Rietzel; Qiang Li; Christoph Bert; Thomas Haberer; Gerhard Kraft

Respiration-induced target motion is a major problem in intensity-modulated radiation therapy. Beam segments are delivered serially to form the total dose distribution. In the presence of motion, the spatial relation between dose deposition from different segments will be lost. Usually, this results in over- and underdosage. Besides such interplay effects between target motion and dynamic beam delivery as known from photon therapy, changes in internal density have an impact on delivered dose for intensity-modulated charged particle therapy. In this study, we have analysed interplay effects between raster scanned carbon ion beams and target motion. Furthermore, the potential of an online motion strategy was assessed in several simulations. An extended version of the clinical treatment planning software was used to calculate dose distributions to moving targets with and without motion compensation. For motion compensation, each individual ion pencil beam tracked the planned target position in the lateral as well as longitudinal direction. Target translations and rotations, including changes in internal density, were simulated. Target motion simulating breathing resulted in severe degradation of delivered dose distributions. For example, for motion amplitudes of +/-15 mm, only 47% of the target volume received 80% of the planned dose. Unpredictability of resulting dose distributions was demonstrated by varying motion parameters. On the other hand, motion compensation allowed for dose distributions for moving targets comparable to those for static targets. Even limited compensation precision (standard deviation approximately 2 mm), introduced to simulate possible limitations of real-time target tracking, resulted in less than 3% loss in dose homogeneity.


Radiation Oncology | 2008

Motion compensation with a scanned ion beam: a technical feasibility study

Sven Oliver Grözinger; Christoph Bert; Thomas Haberer; Gerhard Kraft; Eike Rietzel

BackgroundIntrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target motion by tracking with the treatment beam.MethodsLateral motion components were compensated directly with the beam scanning system by adapting nominal beam positions according to the target motion. Longitudinal motion compensation to mitigate motion induced range changes was performed with a dedicated wedge system that adjusts effective particle energies at isocenter.ResultsLateral compensation performance was better than 1% for a homogeneous dose distribution when comparing irradiations of a stationary radiographic film and a moving film using motion compensation. The accuracy of longitudinal range compensation was well below 1 mm.ConclusionMotion compensation with scanned particle beams is technically feasible with high precision.

Collaboration


Dive into the Eike Rietzel's collaboration.

Top Co-Authors

Avatar

Christoph Bert

University of Erlangen-Nuremberg

View shared research outputs
Top Co-Authors

Avatar

Alexander Gemmel

GSI Helmholtz Centre for Heavy Ion Research

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Nami Saito

GSI Helmholtz Centre for Heavy Ion Research

View shared research outputs
Researchain Logo
Decentralizing Knowledge