World journal of orthopedics | 2012

Male osteoporosis: A review.

Antonio Herrera; Antonio Lobo-Escolar; Jesús Mateo; Jorge Gil; Elena Ibarz; Luis Gracia

Osteoporosis in men is a heterogeneous disease that has received little attention. However, one third of worldwide hip fractures occur in the male population. This problem is more prevalent in people over 70 years of age. The etiology can be idiopathic or secondary to hypogonadism, vitamin D deficiency and inadequate calcium intake, hormonal treatments for prostate cancer, use of toxic and every disease or drug use that alters bone metabolism.Risk factors such as a previous history of fragility fracture should be assessed for the diagnosis. However, risk factors in men are very heterogeneous. There are significant differences in the pharmacological treatment of osteoporosis between men and women fundamentally due to the level of evidence in published trials supporting each treatment. New treatments will offer new therapeutic prospects. The goal of this work is a revision of the present status knowledge about male osteoporosis.


Biomedical Engineering Online | 2010

Study of bone remodeling of two models of femoral cementless stems by means of DEXA and finite elements

Luis Gracia; Elena Ibarz; Sergio Puértolas; José Cegoñino; Fernando López-Prats; Juan J. Panisello; Antonio Herrera

BackgroundA hip replacement with a cemented or cementless femoral stem produces an effect on the bone called adaptive remodelling, attributable to mechanical and biological factors. All of the cementless prostheses designs try to achieve an optimal load transfer in order to avoid stress-shielding, which produces an osteopenia.Long-term densitometric studies taken after implanting ABG-I and ABG-II stems confirm that the changes made to the design and alloy of the ABG-II stem help produce less proximal atrophy of the femur. The simulation with FE allowed us to study the biomechanical behaviour of two stems. The aim of this study was, if possible, to correlate the biological and mechanical findings.MethodsBoth models with prostheses ABG-I and II have been simulated in five different moments of time which coincide with the DEXA measurements: postoperative, 6 months, 1, 3 and 5 years, in addition to the healthy femur as the initial reference. For the complete comparative analysis of both stems, all of the possible combinations of bone mass (group I and group II of pacients in two controlled studies for ABG-I and II stems, respectively), prosthetic geometry (ABG-I and ABG-II) and stem material (Wrought Titanium or TMZF) were simulated.Results and DiscussionIn both groups of bone mass an increase of stress in the area of the cancellous bone is produced, which coincides with the end of the HA coating, as a consequence of the bottleneck effect which is produced in the transmission of loads, and corresponds to Gruen zones 2 and 6, where no osteopenia can be seen in contrast to zones 1 and 7.ConclusionsIn this study it is shown that the ABG-II stem is more effective than the ABG-I given that it generates higher tensional values on the bone, due to which proximal bone atrophy diminishes. This biomechanical behaviour with an improved transmission of loads confirmed by means of FE simulation corresponds to the biological findings obtained with Dual-Energy X-Ray Absorptiometry (DEXA).


BioMed Research International | 2015

Cementless Hydroxyapatite Coated Hip Prostheses

Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; Elena Ibarz; Sergio Gabarre; Yolanda Más; Luis Manuel N. Gracia

More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.


BMC Musculoskeletal Disorders | 2010

Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

Antonio Herrera; Fernando Martinez; Daniel Iglesias; José Cegoñino; Elena Ibarz; Luis Gracia

BackgroundPrimary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces.A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied.MethodsThe tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed.ResultsThe mean loads to failure for each group were 295,44 N (Group 1; 9 × 23 screw), 564,05 N (Group 2; 9 × 28), 614,95 N (Group 3; 9 × 35), 651,14 N (Group 4; 10 × 28) and 664,99 (Group 5; 10 × 35). No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P < 0.001).ConclusionsLonger and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm) do not achieve optimal fixation and should be implanted only with special requirements.


Maturitas | 2015

Prevalence of osteoporotic vertebral fracture in Spanish women over age 45

Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; José M. Artigas; Fernando López-Prats; Manuel Mesa; Elena Ibarz; Luis Gracia

The aim of this work is to study the prevalence of osteoporotic vertebral fractures in Spanish women over 45 years of age, based on the selection of a nationwide sample. An observational, cross-sectional, multicenter study was conducted during 2006, in all of Spains regions. The sample analyzed was of 5000 individuals, representative of the female population over age 45 in Spain. A questionnaire was used to determine which factors are most often associated with vertebral fractures. We also assessed whether the Prevalent Vertebral Fracture Index, proposed by Vogt, is useful in indicating a possible osteoporotic vertebral fracture. Five hundred orthopedic surgeons, from various Spanish regions, were trained in different aspects of the study: inclusion and exclusion criteria, management of the risk factor questionnaire, and implementation of the Vogt questionnaire. The number of fracture cases was 1549 (31.79%). 528 Women (34.08%) had a single vertebral fracture, and 1021 (65.92%) had multiple vertebral fractures. The following factors were statistically significantly associated with vertebral fracture: age, late menarche, early menopause, diabetes mellitus, hyperparathyroidism, rheumatoid arthritis, height loss, daily physical activity, corticosteroid therapy, personal history of osteoporotic fracture and previous diagnosis of osteoporosis. The differences in Vogt score according to age and fracture status were statistically significant. The conclusion of the study is that vertebral osteoporotic fracture in the female Spanish population is frequent. The high prevalence in the Spanish population older than 60 years is probably related to malnutrition in the period from 1936 to 1952.


World journal of orthopedics | 2012

Applications of finite element simulation in orthopedic and trauma surgery

Antonio Herrera; Elena Ibarz; José Cegoñino; Antonio Lobo-Escolar; Sergio Puértolas; Enrique López; Jesús Mateo; Luis Gracia

Research in different areas of orthopedic and trauma surgery requires a methodology that allows both a more economic approach and the ability to reproduce different situations in an easy way. Simulation models have been introduced recently in bioengineering and could become an essential tool in the study of any physiological unity, regardless of its complexity. The main problem in modeling with finite elements simulation is to achieve an accurate reproduction of the anatomy and a perfect correlation of the different structures, in any region of the human body. Authors have developed a mixed technique, joining the use of a three-dimensional laser scanner Roland Picza captured together with computed tomography (CT) and 3D CT images, to achieve a perfect reproduction of the anatomy. Finite element (FE) simulation lets us know the biomechanical changes that take place after hip prostheses or osteosynthesis implantation and biological responses of bone to biomechanical changes. The simulation models are able to predict changes in bone stress distribution around the implant, so allowing preventing future pathologies. The development of a FE model of lumbar spine is another interesting application of the simulation. The model allows research on the lumbar spine, not only in physiological conditions but also simulating different load conditions, to assess the impact on biomechanics. Different degrees of disc degeneration can also be simulated to determine the impact on adjacent anatomical elements. Finally, FE models may be useful to test different fixation systems, i.e., pedicular screws, interbody devices or rigid fixations compared with the dynamic ones. We have also developed models of lumbar spine and hip joint to predict the occurrence of osteoporotic fractures, based on densitometric determinations and specific biomechanical models, including approaches from damage and fracture mechanics. FE simulations also allow us to predict the behavior of orthopedic splints applied to the correction of deformities, providing the recovering force-displacement and angle-moment curves that characterize the mechanical behavior of the splint in the overall range of movement.


Journal of Arthroplasty | 2014

Mid-Term Study of Bone Remodeling After Femoral Cemented Stem Implantation: Comparison Between DXA and Finite Element Simulation

Antonio Herrera; Sarai Rebollo; Elena Ibarz; Jesús Mateo; Sergio Gabarre; Luis Gracia

This five-year prospective study was designed to investigate periprosthetic bone remodeling associated with two cemented stem models, ABG-II (Stryker) and VerSys (Zimmer), randomly implanted in patients older than 75 years. The sample consisted of 64 cases (32, ABG-II; 32, VerSys). Inclusion criterion was diagnosis of osteoarthritis recommended for cemented total hip arthroplasty. Besides clinical study, Finite Element (FE) simulation was used to analyze biomechanical changes caused by hip arthroplasty. Bone Mineral Density (BMD) measurements showed a progressive increase in bone mass throughout the entire follow-up period for both stems, well correlated with FE results except in Gruen zones 4, 5, 6 for ABG-II and in zones 4, 5 for VerSys, denoting that remodeling in those zones does not depend on mechanical factors but rather on biological or physiological ones.


BioMed Research International | 2013

Development and Kinematic Verification of a Finite Element Model for the Lumbar Spine: Application to Disc Degeneration

Elena Ibarz; Antonio Herrera; Yolanda Más; Javier Rodríguez-Vela; José Cegoñino; Sergio Puértolas; Luis Gracia

The knowledge of the lumbar spine biomechanics is essential for clinical applications. Due to the difficulties to experiment on living people and the irregular results published, simulation based on finite elements (FE) has been developed, making it possible to adequately reproduce the biomechanics of the lumbar spine. A 3D FE model of the complete lumbar spine (vertebrae, discs, and ligaments) has been developed. To verify the model, radiological images (X-rays) were taken over a group of 25 healthy, male individuals with average age of 27.4 and average weight of 78.6 kg with the corresponding informed consent. A maximum angle of 34.40° is achieved in flexion and of 35.58° in extension with a flexion-extension angle of 69.98°. The radiological measurements were 33.94 ± 4.91°, 38.73 ± 4.29°, and 72.67°, respectively. In lateral bending, the maximum angles were 19.33° and 23.40 ± 2.39, respectively. In rotation a maximum angle of 9.96° was obtained. The model incorporates a precise geometrical characterization of several elements (vertebrae, discs, and ligaments), respecting anatomical features and being capable of reproducing a wide range of physiological movements. Application to disc degeneration (L5-S1) allows predicting the affection in the mobility of the different lumbar segments, by means of parametric studies for different ranges of degeneration.


Journal of Arthroplasty | 2013

Long-Term Outcomes of a New Model of Anatomical Hydroxyapatite-Coated Hip Prosthesis

Antonio Herrera; Jesús Mateo; Antonio Lobo-Escolar; Juan J. Panisello; Elena Ibarz; Luis Gracia

This prospective study was designed to evaluate 196 Anatomique Benoist Giraud (ABG II) total hip arthroplasties which were implanted between September 1999 and December 2000. A minimum 11 years follow up was completed in 183 cases. The bearing surfaces were polyethylene-zirconia in 84 cases, polyethylene-metal in 42 and ceramic-ceramic in 57. Changes in the femoral stem design, in relation to the previous ABG I model, have led to a significant improvement in stress-shielding. Polyethylene wear rate was lower by more than 50% compared with non-crosslinked polyethylene. Excellent and good results were obtained in 90.32% of cases, and implant survival was 98.39% at the end of follow-up.


Biomedical Engineering Online | 2012

A mechanical model for predicting the probability of osteoporotic hip fractures based in DXA measurements and finite element simulation

Enrique López; Elena Ibarz; Antonio Herrera; Jesús Mateo; Antonio Lobo-Escolar; Sergio Puértolas; Luis Gracia

BackgroundOsteoporotic hip fractures represent major cause of disability, loss of quality of life and even mortality among the elderly population. Decisions on drug therapy are based on the assessment of risk factors for fracture, from BMD measurements. The combination of biomechanical models with clinical studies could better estimate bone strength and supporting the specialists in their decision.MethodsA model to assess the probability of fracture, based on the Damage and Fracture Mechanics has been developed, evaluating the mechanical magnitudes involved in the fracture process from clinical BMD measurements. The model is intended for simulating the degenerative process in the skeleton, with the consequent lost of bone mass and hence the decrease of its mechanical resistance which enables the fracture due to different traumatisms. Clinical studies were chosen, both in non-treatment conditions and receiving drug therapy, and fitted to specific patients according their actual BMD measures. The predictive model is applied in a FE simulation of the proximal femur. The fracture zone would be determined according loading scenario (sideway fall, impact, accidental loads, etc.), using the mechanical properties of bone obtained from the evolutionary model corresponding to the considered time.ResultsBMD evolution in untreated patients and in those under different treatments was analyzed. Evolutionary curves of fracture probability were obtained from the evolution of mechanical damage. The evolutionary curve of the untreated group of patients presented a marked increase of the fracture probability, while the curves of patients under drug treatment showed variable decreased risks, depending on the therapy type.ConclusionThe FE model allowed to obtain detailed maps of damage and fracture probability, identifying high-risk local zones at femoral neck and intertrochanteric and subtrochanteric areas, which are the typical locations of osteoporotic hip fractures.The developed model is suitable for being used in individualized cases. The model might better identify at-risk individuals in early stages of osteoporosis and might be helpful for treatment decisions.

Collaboration


Dive into the Elena Ibarz's collaboration.

Top Co-Authors

Avatar

Luis Gracia

Polytechnic University of Valencia

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jesús Mateo

Centro Nacional de Investigaciones Cardiovasculares

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge