Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Erin Angel is active.

Publication


Featured researches published by Erin Angel.


Radiology | 2008

Radiation dose to the fetus for pregnant patients undergoing multidetector CT imaging: Monte carlo simulations estimating fetal dose for a range of gestational age and patient size1

Erin Angel; Clinton V. Wellnitz; Mitchell M. Goodsitt; Nazanin Yaghmai; J DeMarco; Christopher H. Cagnon; James Sayre; Dianna D. Cody; Donna M. Stevens; Andrew N. Primak; Cynthia H. McCollough; Michael F. McNitt-Gray

PURPOSE To use Monte Carlo simulations of a current-technology multidetector computed tomographic (CT) scanner to investigate fetal radiation dose resulting from an abdominal and pelvic examination for a range of actual patient anatomies that include variation in gestational age and maternal size. MATERIALS AND METHODS Institutional review board approval was obtained for this HIPAA-compliant retrospective study. Twenty-four models of maternal and fetal anatomy were created from image data from pregnant patients who had previously undergone clinically indicated CT examination. Gestational age ranged from less than 5 weeks to 36 weeks. Simulated helical scans of the abdominal and pelvic region were performed, and a normalized dose (in milligrays per 100 mAs) was calculated for each fetus. Stepwise multiple linear regression was performed to analyze the correlation of dose with gestational age and anatomic measurements of maternal size and fetal location. Results were compared with several existing fetal dose estimation methods. RESULTS Normalized fetal dose estimates from the Monte Carlo simulations ranged from 7.3 to 14.3 mGy/100 mAs, with an average of 10.8 mGy/100 mAs. Previous methods yielded values of 10-14 mGy/100 mAs. The correlation between gestational age and fetal dose was not significant (P = .543). Normalized fetal dose decreased linearly with increasing patient perimeter (R(2) = 0.681, P < .001), and a two-factor model with patient perimeter and fetal depth demonstrated a strong correlation with fetal dose (R(2) = 0.799, P < .002). CONCLUSION A method for the estimation of fetal dose from models of actual patient anatomy that represented a range of gestational age and patient size was developed. Fetal dose correlated with maternal perimeter and varied more than previously recognized. This correlation improves when maternal size and fetal depth are combined.


Medical Physics | 2010

The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDIvol to account for differences between scanners

A Turner; Maria Zankl; J DeMarco; Christopher H. Cagnon; Di Zhang; Erin Angel; Dianna D. Cody; Donna M. Stevens; Cynthia H. McCollough; Michael F. McNitt-Gray

PURPOSE Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDIvol measurements to account for differences in MDCT scanners that lead to organ dose differences. METHODS Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDIvol values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDIvol value for those acquisition conditions. RESULTS CTDIvol values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDIvoI values, the differences across scanners become very small. For the CTDIvol, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. CONCLUSIONS This work has revealed that there is considerable variation among modern MDCT scanners in both CTDIvol and organ dose values. Because these variations are similar, CTDIvol can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDIvol to account for the differences between scanners.


American Journal of Roentgenology | 2009

Dose to radiosensitive organs during routine chest CT: Effects of tube current modulation

Erin Angel; Nazanin Yaghmai; Cecilia Matilda Jude; J DeMarco; Christopher H. Cagnon; Jonathan G. Goldin; Cynthia H. McCollough; Andrew N. Primak; Dianna D. Cody; Donna M. Stevens; Michael F. McNitt-Gray

OBJECTIVE The aims of this study were to estimate the dose to radiosensitive organs (glandular breast and lung) in patients of various sizes undergoing routine chest CT examinations with and without tube current modulation; to quantify the effect of tube current modulation on organ dose; and to investigate the relation between patient size and organ dose to breast and lung resulting from chest CT examinations. MATERIALS AND METHODS Thirty voxelized models generated from images of patients were extended to include lung contours and were used to represent a cohort of women of various sizes. Monte Carlo simulation-based virtual MDCT scanners had been used in a previous study to estimate breast dose from simulations of a fixed-tube-current and a tube current-modulated chest CT examinations of each patient model. In this study, lung doses were estimated for each simulated examination, and the percentage organ dose reduction attributed to tube current modulation was correlated with patient size for both glandular breast and lung tissues. RESULTS The average radiation dose to lung tissue from a chest CT scan obtained with fixed tube current was 23 mGy. The use of tube current modulation reduced the lung dose an average of 16%. Reductions in organ dose (up to 56% for lung) due to tube current modulation were more substantial among smaller patients than larger. For some larger patients, use of tube current modulation for chest CT resulted in an increase in organ dose to the lung as high as 33%. For chest CT, lung dose and breast dose estimates had similar correlations with patient size. On average the two organs receive approximately the same dose effects from tube current modulation. CONCLUSION The dose to radiosensitive organs during fixed-tube-current and tube current-modulated chest CT can be estimated on the basis of patient size. Organ dose generally decreases with the use of tube current-modulated acquisition, but patient size can directly affect the dose reduction achieved.


Physics in Medicine and Biology | 2009

Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT

Erin Angel; Nazanin Yaghmai; Cecilia Matilda Jude; J DeMarco; Christopher H. Cagnon; Jonathan G. Goldin; Andrew N. Primak; Donna M. Stevens; Dianna D. Cody; Cynthia H. McCollough; Michael F. McNitt-Gray

Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patients glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patients clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were size dependent with smaller patients getting better dose reduction (up to 64% reduction) and larger patients getting a smaller reduction, and in some cases the dose actually increased when using tube current modulation (up to 41% increase). The results indicate that radiation dose to glandular breast tissue generally decreases with the use of tube current modulated CT acquisition, but that patient size (and in some cases patient positioning) may affect dose reduction.


American Journal of Roentgenology | 2012

Radiation Dose Estimation for Prospective and Retrospective ECG-Gated Cardiac CT Angiography in Infants and Small Children Using a 320-MDCT Volume Scanner

Daniel J. Podberesky; Erin Angel; Terry T. Yoshizumi; Greta Toncheva; Shelia Salisbury; Christopher Alsip; Alessandra Barelli; John C. Egelhoff; Colin Anderson-Evans; Giao Nguyen; David Dow; Donald P. Frush

OBJECTIVE The purpose of this study is to determine patient dose estimates for clinical pediatric cardiac-gated CT angiography (CTA) protocols on a 320-MDCT volume scanner. MATERIALS AND METHODS Organ doses were measured using 20 metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Radiation dose was estimated for volumetrically acquired clinical pediatric prospectively and retrospectively ECG-gated cardiac CTA protocols in 5-year-old and 1-year-old anthropomorphic phantoms on a 320-MDCT scanner. Simulated heart rates of 60 beats/min (5-year-old phantom) and 120 beats/min (1- and 5-year-old phantoms) were used. Effective doses (EDs) were calculated using average measured organ doses and International Commission on Radiological Protection 103 tissue-weighting factors. Dose-length product (DLP) was recorded for each examination and was used to develop dose conversion factors for pediatric cardiac examinations acquired with volume scan mode. DLP was also used to estimate ED according to recently published dose conversion factors for pediatric helical chest examinations. Repeated measures and paired Student t test analyses were performed. RESULTS For the 5-year-old phantom, at 60 beats/min, EDs ranged from 1.2 mSv for a prospectively gated examination to 4.5 mSv for a retrospectively gated examination. For the 5-year-old phantom, at 120 beats/min, EDs ranged from 3.0 mSv for a prospectively gated examination to 4.9 mSv for a retrospectively gated examination. For the 1-year-old phantom, at 120 beats/min, EDs ranged from 2.7 mSv for a prospectively gated examination to 4.5 mSv for a retrospectively gated examination. CONCLUSION EDs for 320-MDCT volumetrically acquired ECG-gated pediatric cardiac CTA are lower than those published for conventional 16- and 64-MDCT scanners.


Pediatric Radiology | 2013

Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT

Jennifer H. Johnston; Daniel J. Podberesky; Terry T. Yoshizumi; Erin Angel; Greta Toncheva; David B. Larson; John C. Egelhoff; Colin Anderson-Evans; Giao Nguyen; Alessandra Barelli; Christopher Alsip; Shelia Salisbury; Donald P. Frush

BackgroundAdvanced multidetector CT systems facilitate volumetric image acquisition, which offers theoretic dose savings over helical acquisition with shorter scan times.ObjectiveCompare effective dose (ED), scan duration and image noise using 320- and 64-detector CT scanners in various acquisition modes for clinical chest, abdomen and pelvis protocols.Materials and methodsED and scan durations were determined for 64-detector helical, 160-detector helical and volume modes under chest, abdomen and pelvis protocols on 320-detector CT with adaptive collimation and 64-detector helical mode on 64-detector CT without adaptive collimation in a phantom representing a 5-year-old child. Noise was measured as standard deviation of Hounsfield units.ResultsCompared to 64-detector helical CT, all acquisition modes on 320-detector CT resulted in lower ED and scan durations. Dose savings were greater for chest (27–46%) than abdomen/pelvis (18–28%) and chest/abdomen/pelvis imaging (8–14%). Noise was similar across scanning modes, although some protocols on 320-detector CT produced slightly higher noise.ConclusionDose savings can be achieved for chest, abdomen/pelvis and chest/abdomen/pelvis examinations on 320-detector CT compared to helical acquisition on 64-detector CT, with shorter scan durations. Although noise differences between some modes reached statistical significance, this is of doubtful diagnostic significance and will be studied further in a clinical setting.


Medical Physics | 2009

Pediatric organ dose measurements in axial and helical multislice CT

Alanna McDermott; R. Allen White; M McNitt‐Gray; Erin Angel; Dianna D. Cody

An anthropomorphic pediatric phantom (5-yr-old equivalent) was used to determine organ doses at specific surface and internal locations resulting from computed tomography (CT) scans. This phantom contains four different tissue-equivalent materials: Soft tissue, bone, brain, and lung. It was imaged on a 64-channel CT scanner with three head protocols (one contiguous axial scan and two helical scans [pitch = 0.516 and 0.984]) and four chest protocols (one contiguous axial scan and three helical scans [pitch = 0.516, 0.984, and 1.375]). Effective mA s [= (tube current x rotation time)/pitch] was kept nearly constant at 200 effective mA s for head and 290 effective mA s for chest protocols. Dose measurements were acquired using thermoluminescent dosimeter powder in capsules placed at locations internal to the phantom and on the phantom surface. The organs of interest were the brain, both eyes, thyroid, sternum, both breasts, and both lungs. The organ dose measurements from helical scans were lower than for contiguous axial scans by 0% to 25% even after adjusting for equivalent effective mA s. There was no significant difference (p > 0.05) in organ dose values between the 0.516 and 0.984 pitch values for both head and chest scans. The chest organ dose measurements obtained at a pitch of 1.375 were significantly higher than the dose values obtained at the other helical pitches used for chest scans (p < 0.05). This difference was attributed to the automatic selection of the large focal spot due to a higher tube current value. These findings suggest that there may be a previously unsuspected radiation dose benefit associated with the use of helical scan mode during computed tomography scanning.


Medical Imaging 2007: Computer-Aided Diagnosis | 2007

Forming a reference standard from LIDC data: impact of reader agreement on reported CAD performance

Robert A. Ochs; Hyun J. Kim; Erin Angel; Christoph Panknin; Michael F. McNitt-Gray; Matthew S. Brown

The Lung Image Database Consortium (LIDC) has provided a publicly available collection of CT images with nodule markings from four radiologists. The LIDC protocol does not require radiologists to reach a consensus during the reading process, and as a result, there are varying levels of reader agreement for each potential nodule with no explicit reference standard for nodules. The purpose of this work was to investigate the effects of the level of reader agreement on the development of a reference standard and the subsequent impact on CAD performance. Ninety series were downloaded from the LIDC database. Four different reference standards were created based on the markings of the LIDC radiologists, reflecting four different levels of reader agreement. All series were analyzed with a research CAD system and its performance was measured against each of the four standards. Between the standards with the lowest (any 1 of 4 readers) and highest (all 4 readers) required level of reader agreement, the number of nodules ⩾ 3 mm decreased 48% (from 174 to 90) and CAD sensitivity for nodules ⩾ 3 mm increased from 0.70 ± 0.34 to 0.79 ± 0.35. Between the same reference standards, the number of nodules < 3 mm decreased 84% (from 483 to 75) and CAD sensitivity for nodules < 3 mm increased from 0.30 ± 0.29 to 0.51 ± 0.45. This research illustrates the importance of indicating the method used to form the reference standard, since the method influences both the number of nodules and reported CAD performance.


Academic Radiology | 2013

Comparison of Radiation Dose Estimates and Scan Performance in Pediatric High-Resolution Thoracic CT for Volumetric 320-Detector Row, Helical 64-Detector Row, and Noncontiguous Axial Scan Acquisitions

Daniel J. Podberesky; Erin Angel; Terry T. Yoshizumi; Greta Toncheva; Shelia Salisbury; Alan S. Brody; Christopher Alsip; Alessandra Barelli; John C. Egelhoff; Colin Anderson-Evans; Giao Nguyen; David Dow; Donald P. Frush

RATIONALE AND OBJECTIVES Efforts to decrease radiation exposure during pediatric high-resolution thoracic computed tomography (HRCT), while maintaining diagnostic image quality, are imperative. The objective of this investigation was to compare organ doses and scan performance for pediatric HRCT using volume, helical, and noncontiguous axial acquisitions. MATERIALS AND METHODS Thoracic organ doses were measured using 20 metal oxide semiconductor field-effect transistor dosimeters. Mean and median organ doses and scan durations were determined and compared for three acquisition modes in a 5-year-old anthropomorphic phantom using similar clinical pediatric scan parameters. Image noise was measured and compared in identical regions within the thorax. RESULTS There was a significantly lower dose in lung (1.8 vs 2.7 mGy, P < .02) and thymus (2.3 vs 2.7 mGy, P < .02) between volume and noncontiguous axial modes and in lung (1.8 vs 2.3 mGy, P < .02), breast (1.8 vs 2.6 mGy, P < .02), and thymus (2.3 vs 2.4 mGy, P < .02) between volume and helical modes. There was a significantly lower median image noise for volume compared to helical and axial modes in lung (55.6 vs 79.3 and 70.7) and soft tissue (76.0 vs 111.3 and 89.9). Scan times for volume, helical, and noncontiguous axial acquisitions were 0.35, 3.9, and 24.5 seconds, respectively. CONCLUSION Volumetric HRCT provides an opportunity for thoracic organ dose and image noise reduction, at significantly faster scanning speeds, which may benefit pediatric patients undergoing surveillance studies for diffuse lung disease.


Journal of Cardiovascular Computed Tomography | 2011

Relationship between chest lateral width, tube current, image noise, and radiation exposure associated with coronary artery calcium scanning on 320-detector row CT

Zhen Qian; Parag H. Joshi; Ayesha F. Shaukat; Torrance Laury; Ben Kirkland; Lori Meyers; Allison Drew; Erin Angel; Eric Krivitsky; Ambar Bajpai; Gustavo Vazquez; Christian O’Rourke; J. Jeffrey Carr; Sarah Rinehart; Szilard Voros

BACKGROUND The relationship between chest lateral width, tube current, image noise, and radiation exposure on 320-detector row CT has not been reported. OBJECTIVE We investigated the relationships between chest lateral width, estimated radiation exposure (DLPe), and image noise in 300 patients undergoing clinical coronary calcium scanning. METHODS Patients undergoing coronary calcium scanning with 320-detector row CT (prospective, volumetric mode, 120 kV of tube voltage, 100-550 mA of tube current, 0.5-mm detector width) were grouped by chest lateral width (small, medium, and large) from anteroposterior topograms and 100 consecutive patients were selected from each group (n = 300). Tube current, DLPe, and noise were compared among groups with Kruskal-Wallis or one-way ANOVA. Phantom experiments were performed to evaluate the accuracy of calcium quantification as a function of size and tube current. RESULTS Median tube current in small, medium, and large patients was 130, 200, and 250 mA, respectively (P < 0.0001). Despite the use of higher tube current settings, noise levels also increased with size (20.2 ± 4.5 HU, 22.0 ± 3.9 HU, and 25.1 ± 4.9 HU, respectively; global P < 0.001). DLPe was significantly higher with increasing size (54, 83, and 104 mGy · cm, respectively; P < 0.0001). Phantom experiments showed that 50-100 mA, 150-200 mA, and approximately 300 mA in small, medium, and large phantoms were associated with stable estimate of calcium. CONCLUSIONS Increasing chest lateral width is associated with increasing radiation exposure and image noise. The use of 50-100 mA in small and 150-200 mA in medium patients is associated with acceptable noise and stable estimate of coronary artery calcium. In large patients, precise identification of individual calcified lesions remains difficult despite increasing tube current and radiation exposure.

Collaboration


Dive into the Erin Angel's collaboration.

Top Co-Authors

Avatar

J DeMarco

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Dianna D. Cody

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

A Turner

University of California

View shared research outputs
Top Co-Authors

Avatar

Donna M. Stevens

University of Texas MD Anderson Cancer Center

View shared research outputs
Top Co-Authors

Avatar

Di Zhang

University of California

View shared research outputs
Researchain Logo
Decentralizing Knowledge