Journal of Endodontics | 2001

Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation.

Ernesto Rapisarda; Antonio Bonaccorso; Teresa Roberta Tripi; Guido Guglielmo Condorelli; Lorenzo Torrisi

The present work analyzes possible increases in resistance to wear of nickel-titanium endodontic instruments that have undergone a process of ionic implantation. ProFile .04 taper #25 instruments were subjected to ionic implantation with bands of nitrogen ions of 250 KeV, currents in the order of 10 microA/cm2, and doses of 2 x 10(17) ions/ cm2. The instruments were used to make preparations in acrylic endodontic training blocks. Scanning electron microscopic investigations showed that after 60 s of work inside the endodontic training blocks nonionic implanted control instruments showed small modifications in their blades, and their tips showed the first signs of wear. After 240 s the control instruments showed consistent signs of wear and frequent changes to their surfaces. After 240 s of use the ionic-implanted instruments did not present any significant changes in the micromorphology of their surfaces. The implanted instruments did not manifest the typical signs of wear and did not show the surface changes that quickly affect the working life of untreated endodontic instruments manufactured from nickel-titanium.


Journal of Endodontics | 2001

Defects in GT Rotary Instruments After Use: An SEM Study

Teresa Roberta Tripi; Antonio Bonaccorso; Valeria Tripi; Guglielmo Guido Condorelii; Ernesto Rapisarda

Used rotary nickel-titanium instruments require frequent replacement. This laboratory study evaluated defects of GT Rotary instruments before and after usage. The instruments were fixed into custom-made holders and photographed in an SEM at x 260 to x 12,000 magnification at preset points. Instrument sizes 20 with 1.0, 0.8, and 0.6 taper and instrument sizes 35 with 1.2 taper were used in 12 canals. The used instruments were cleaned and then reexamined in an SEM as before. The presence of 11 types of conditions was scored from the pre- and postusage photographs. No instruments fracturing or plastic deformation was observed during the test. The presence of debris, pitting, and scraping changed significantly. Imperfections were found on used GT Rotary instruments and the presence of defects (pitting, scraping, and blunt-cutting edges) increased in all of the instruments. The behavior of GT Rotary instruments with usage seems to be different, compared with that found in other instruments.


International Endodontic Journal | 2015

Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments

Eugenio Pedullà; F. Lo Savio; Simona Boninelli; Gianluca Plotino; Nicola M. Grande; Ernesto Rapisarda; G. La Rosa

AIM To evaluate the effect of different torsional preloads on cyclic fatigue resistance of endodontic rotary instruments constructed from conventional nickel-titanium (NiTi), M-Wire or CM-Wire. METHODOLOGY Eighty new size 25, 0.06 taper Mtwo instruments (Sweden & Martina), size 25, 0.06 taper HyFlex CM (Coltene/Whaledent, Inc) and X2 ProTaper Next (Dentsply Maillefer) were used. The Torque and distortion angles at failure of new instruments (n = 10) were measured, and 0% (n = 10), 25%, 50% and 75% (n = 20) of the mean ultimate torsional strength as preloading condition were applied according to ISO 3630-1 for each brand. The twenty files tested for every extent of preload were subjected to 20 or 40 torsional cycles (n = 10). After torsional preloading, the number of cycles to failure was evaluated in a simulated canal with 60° angle of curvature and 5 mm of radius of curvature. Data were analysed using two-way analysis of variance. The fracture surface of each fragment was examined with a scanning electron microscope (SEM). Data were analysed by two-way analyses of variance. RESULTS Preload repetitions did not influence the cyclic fatigue of the three brands; however, the 25%, 50% and 75% torsional preloading significantly reduced the fatigue resistance of all instruments tested (P < 0.01, P < 0.001 and P < 0.0001, respectively) except for the HyFlex CM preloaded with 25% of the maximum torsional strength (P > 0.05). CONCLUSIONS Torsional preloads reduced the cyclic fatigue resistance of conventional and treated (M-wire and CM-wire) NiTi rotary instruments except for size 25, 0.06 taper HyFlex CM instruments with a 25% of torsional preloading.


Journal of Endodontics | 2011

Cyclic Fatigue Resistance of Three Different Nickel-Titanium Instruments after Immersion in Sodium Hypochlorite

Eugenio Pedullà; Nicola M. Grande; Gianluca Plotino; Alfio Pappalardo; Ernesto Rapisarda

INTRODUCTION The purpose of this study was to assess the resistance to cyclic fatigue of three nickel-titanium (NiTi) files after the immersion in sodium hypochlorite (NaOCl) solution in conditions similar to those used in clinical practice. METHODS A total of 150 new Twisted Files (SybronEndo, Orange, CA), Revo S SU files (Micro Mega, Besancon, France), and Mtwo files (Sweden and Martina, Padova, Italy), size 25.06, were tested. Fifty files of the same brand were randomly assigned to five groups (n = 10) and submitted to the following immersion protocol in 5% NaOCl at 37°C for 16 mm: no immersion (control), 5 minutes statically, 1 minute statically, 5 minutes dynamically (300 rpm/min), and 1 minute dynamically. Resistance to cyclic fatigue was determined by counting the numbers of cycles to failure in a 60° curve with a 5-mm radius. Data were analyzed by two-way analyses of variance. RESULTS Resistance to cyclic fatigue of the same NiTi file was not significantly affected by immersion in NaOCl (P > .05). The Twisted File showed a higher resistance in all groups than Revo S SU (P < .001). The comparison between the same groups of Twisted Files and Mtwo files or between Mtwo and Revo S files did not show significant differences (P > .05) except for two cases: group 2 of the Twisted Files and Mtwo files and group 5 of the Mtwo and Revo S SU files (P < .05). CONCLUSIONS Static or dynamic immersion in NaOCl for 1 minute or 5 minutes did not reduce the cyclic fatigue resistance of NiTi significantly. However, the type of instrument influences cyclic fatigue resistance. In our study, Twisted Files were more resistant followed by Mtwo and Revo S SU files.


Journal of Endodontics | 2002

Depositions of Nitrogen on NiTi Instruments

Teresa Roberta Tripi; Antonio Bonaccorso; Ernesto Rapisarda; Valeria Tripi; Guido Guglielmo Condorelli; Roberto Marino; Ignazio L. Fragalà

This study was designed to obtain nitrogen-rich layers on the surfaces of endodontic files made of nickel-titanium (NiTi) alloy by chemical vapor deposition. Experimental samples (GT rotary instruments) were deposited by using two different methods. The first one was based on the reaction of wet NH3 with NiTi under high temperatures (300 degrees C). The second technique is a typical MOCVD (metal organic chemical vapor deposition) procedure that uses Ti(Et2N)4 as a titanium and nitrogen precursor. Control samples were not exposed to any process. The chemical composition of the surface layers of each sample was determined by means of X-ray photoelectron spectroscopy and X-ray diffraction measurements. The experimental instruments showed surface chemical composition that was different from that seen in the control group; samples treated with gaseous NH3 showed a surface nitrogen/titanium (N/Ti) ratio = 0.9; MOCVD instruments showed a surface N/Ti ratio of 2; control samples showed a N/Ti ratio = 0.2; MOCVD of nitrogen ion of nickel-titanium files produced a higher concentration of nitrogen on the surface.


Journal of Endodontics | 2014

Cyclic fatigue resistance of nickel-titanium instruments after immersion in irrigant solutions with or without surfactants.

Eugenio Pedullà; Giovanni Franciosi; Hani F. Ounsi; Marella Tricarico; Ernesto Rapisarda; Simone Grandini

INTRODUCTION The aim of the study was to assess cyclic fatigue resistance of reciprocating (Reciproc and WaveOne) and continuous rotating (ProTaper) nickel-titanium files after immersion in different irrigation solutions with or without surfactants during several short time periods. METHODS A total of 270 new Reciproc R25, WaveOne Primary, and ProTaper F2 files were tested. Instruments of each brand were divided into 1 control group (n = 10) formed by new files and 4 test groups (n = 20) formed by instruments dynamically immersed at 37°C for 16 mm in 5.25% sodium hypochlorite (NaOCl), Hypoclean (5.25% NaOCl with surfactant), 17% EDTA, or EDTA Plus (17% EDTA with surfactant). Each test group was subdivided into 2 subgroups (n = 10) on the basis of the time of dynamic immersion in the endodontic irrigant solution (45 seconds or 3 minutes). Resistance to cyclic fatigue was determined by recording time to fracture in a stainless steel artificial canal with a 60° angle of curvature and 5-mm radius of curvature. The fracture surface was examined by using scanning electron microscopy. RESULTS Immersion in NaOCl did not reduce the cyclic fatigue of reciprocating or continuous nickel-titanium files. The 17% EDTA reduced the fatigue resistance of all instruments after 3 minutes. The immersion in irrigants with surfactants did not influence the cyclic fatigue of instruments except for Reciproc immersed in Hypoclean solution. CONCLUSIONS EDTA immersion reduced the cyclic fatigue resistance of all instruments after 3 minutes. Addition of surfactants did not influence the cyclic fatigue of files except when added to NaOCl when it contacts Reciproc instruments.


Advances in Science and Technology | 2006

Pulsed Laser Deposition (PLD) Technique to Prepare Biocompatible Thin Films

Joseph J. Beltrano; L. Torrisi; Anna Maria Visco; N. Campo; Ernesto Rapisarda

A Nd:YAG laser is employed to ablate different materials useful in the bio-medical field. The laser source operates in the IR (1064 nm), VIS (532 nm) and UV (355 nm) regions with a pulse duration of 3-9 ns, a pulse energy of 3-300 mJ, a spot size of 1 mm2 and a repetition rate of 1- 30 Hz. Target material of interest are Titanium, Carbon, Hydroxyapatite (HA) and Polyethylene (PE). Laser irradiation occurs in vacuum, where hot plasma is generated, and thin films are deposited on near substrates. Generally, substrates of silicon, titanium, titanium-alloys and polymers were employed. Biocompatible thin films are investigated with different surface techniques, such as IR spectroscopy, Raman spectroscopy, XRD analysis and SEM investigations. Depending of the kind of possible application, films require special properties concerning the grain size, porosity, uniformity, wetting, hardness, adhesion, crystallinity and composition. The obtained results will be presented and discussed with particular regard to HA..


Restorative Dentistry and Endodontics | 2018

Cyclic fatigue resistance, torsional resistance, and metallurgical characteristics of M3 Rotary and M3 Pro Gold NiTi files

Eugenio Pedullà; Fabio Lo Savio; Giusy Rita Maria La Rosa; Gabriele Miccoli; E. Bruno; Silvia Rapisarda; Seok Woo Chang; Ernesto Rapisarda; Guido La Rosa; Gianluca Gambarini; Luca Testarelli

Objectives To evaluate the mechanical properties and metallurgical characteristics of the M3 Rotary and M3 Pro Gold files (United Dental). Materials and Methods One hundred and sixty new M3 Rotary and M3 Pro Gold files (sizes 20/0.04 and 25/0.04) were used. Torque and angle of rotation at failure (n = 20) were measured according to ISO 3630-1. Cyclic fatigue resistance was tested by measuring the number of cycles to failure in an artificial stainless steel canal (60° angle of curvature and a 5-mm radius). The metallurgical characteristics were investigated by differential scanning calorimetry. Data were analyzed using analysis of variance and the Student-Newman-Keuls test. Results Comparing the same size of the 2 different instruments, cyclic fatigue resistance was significantly higher in the M3 Pro Gold files than in the M3 Rotary files (p < 0.001). No significant difference was observed between the files in the maximum torque load, while a significantly higher angular rotation to fracture was observed for M3 Pro Gold (p < 0.05). In the DSC analysis, the M3 Pro Gold files showed one prominent peak on the heating curve and 2 prominent peaks on the cooling curve. In contrast, the M3 Rotary files showed 1 small peak on the heating curve and 1 small peak on the cooling curve. Conclusions The M3 Pro Gold files showed greater flexibility and angular rotation than the M3 Rotary files, without decrement of their torque resistance. The superior flexibility of M3 Pro Gold files can be attributed to their martensite phase.


European Endodontic Journal | 2017

Influence of Continuous or Reciprocating Optimum Torque Reverse Motion on Cyclic Fatigue Resistance of Two Single-File Nickel-Titanium Rotary Instruments

Eugenio Pedullà; Giacomo Corsentino; Emanuele Ambu; Fabio Rovai; Federico Campedelli; Silvia Rapisarda; Giusy Rita Maria La Rosa; Ernesto Rapisarda; Simone Grandini

Objective: Different single-file instruments and kinematics have been introduced on the market. It is important to know the cyclic fatigue performance of these instruments in these new kinematics such as reciprocation of Optimum Torque Reverse (OTR) motion. The aim of this study was to evaluate the resistance to cyclic fatigue of F6 SkyTaper and OneShape used in continuous rotation (proper rotation) or in reciprocating OTR motion. Methods: A total of forty-eight nickel-titanium files were tested. Twenty-four instruments of both brands were divided into two groups (n=12) on the basis of the motion tested: continuous rotation (group 1) or reciprocating OTR motion (group 2). Resistance to cyclic fatigue was determined by recording time to fracture (TtF) in a stainless steel artificial canal with a 60° angle of curvature and 5 mm radius of curvature. Data were analysed by two-way analysis of variance and post-hoc Bonferroni tests for multiple comparisons with P<0.05 as the level of significance. Results: F6 SkyTaper showed higher TtF compared with OneShape, both in continuous and in OTR motion (P<0.0001). The two tested instruments showed higher cyclic fatigue resistance in reciprocating OTR motion than continuous rotation (P<0.0001). Conclusions: OTR motion significantly improves cyclic fatigue resistance of the tested instruments. In addition, F6 SkyTaper showed higher cyclic fatigue resistance than OneShape in both motions.


Journal of Endodontics | 2013

Influence of Continuous or Reciprocating Motion on Cyclic Fatigue Resistance of 4 Different Nickel-Titanium Rotary Instruments

Eugenio Pedullà; Nicola M. Grande; Gianluca Plotino; Gianluca Gambarini; Ernesto Rapisarda

Collaboration


Dive into the Ernesto Rapisarda's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gianluca Plotino

Sapienza University of Rome

View shared research outputs
Top Co-Authors

Avatar