Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Eva Klarić is active.

Publication


Featured researches published by Eva Klarić.


Operative Dentistry | 2015

Raman Spectroscopic Assessment of Degree of Conversion of Bulk-Fill Resin Composites - Changes at 24 Hours Post Cure

Matej Par; Ozren Gamulin; Danijela Marović; Eva Klarić; Zrinka Tarle

OBJECTIVE The aim of this study was to determine degree of conversion (DC) of solid and flowable bulk-fill composites immediately and after 24 hours and investigate the variations of DC at surface and depths up to 4 mm. MATERIALS AND METHODS Eight bulk-fill composites (Tetric EvoCeram Bulk Fill [shades IVA and IVB], Quixfil, X-tra fil, Venus Bulk Fill, X-tra Base, SDR, Filtek Bulk Fill) were investigated, and two conventional composites (GrandioSO, X-Flow) were used as controls. The samples (n = 5) were cured for 20 seconds with irradiance of 1090 mW/cm(2). Raman spectroscopic measurements were made immediately after curing on sample surfaces and after 24 hours of dark storage at surface and at incremental depths up to 4 mm. Mean DC values were compared using repeated measures analysis of variance (ANOVA) and t-test for dependent samples. RESULTS Surface DC values immediately after curing ranged from 59.1%-71.8%, while the 24-hour postcure values ranged from 71.3%-86.1%. A significant increase of DC was observed 24 hours post cure for all bulk-fill composites, which amounted from 11.3% to 16.9%. Decrease of DC through depths up to 4 mm varied widely among bulk-fill composites and ranged from 2.9% to 19.7%. CONCLUSIONS All bulk-fill composites presented a considerable 24-hour postcure DC increase and clinically acceptable DC at depths up to 4 mm. Conventional control composites were sufficiently cured only up to 2 mm, despite significant postcure polymerization.


Operative Dentistry | 2015

Enamel and Dentin Microhardness and Chemical Composition After Experimental Light-activated Bleaching.

Eva Klarić; Mario Rakić; Ivan Sever; Ognjen Milat; Matej Par; Zrinka Tarle

OBJECTIVES To evaluate 1) the influence of five bleaching agents (with additional light activation) on enamel and dentin surface microhardness and chemical composition and 2) the remineralizing potential of artificial saliva and amorphous calcium phosphate (ACP). METHODS AND MATERIALS The study was conducted on 125 human third molars dissected into quarters for separate enamel and dentin measurements. The bleaching process was performed with 38% and 25% hydrogen peroxide (HP) and 30%, 16%, and 10% carbamide peroxide (CP) gels two times for 15 minutes each time. All bleaching gels were tested alone and in combination with ZOOM2, light-emitting diode (LED), organic LED, and femtosecond laser. A total of 25 bleaching combinations (n=10) were evaluated. Microhardness was measured by a Vickers diamond. Chemical analysis was performed using energy-dispersive X-ray spectroscopy. RESULTS Bleaching agents used in the absence of light activation caused a significant reduction in enamel and dentin surface microhardness (p<0.001), ranging from 8% for 16% CP to 40% for 25% HP. The effects of different light activations were negligible. After two-week treatment with ACP and artificial saliva, maximum deviation from baseline microhardness was just 3%. Such treatment increased the concentrations of calcium, phosphorus, and fluorine. CONCLUSIONS An increase in peroxide concentration and gel acidity negatively affected microhardness and concentrations of calcium and phosphorus in enamel and dentin. ACP and artificial saliva stimulated the remineralization of hard tissues.


Journal of Dentistry | 2016

Conversion and temperature rise of remineralizing composites reinforced with inert fillers.

Matej Par; Ozren Gamulin; Danijela Marović; Hrvoje Skenderović; Eva Klarić; Zrinka Tarle

OBJECTIVES Remineralizing experimental composites based on amorphous calcium phosphate (ACP) were investigated. The impact of curing time (20 and 40s), curing depth (1, 2, 3 and 4mm) and addition of inert fillers (barium glass and silica) on the conversion and temperature rise during curing were examined. METHODS Five ACP-composites and two control composites were prepared based on the light-curable EBPADMA-TEGDMA-HEMA resin. For temperature measurements, a commercial composite was used as an additional control. Conversion was assessed using FT-Raman spectroscopy by comparing the relative change of the band at 1640 cm(-1) before and after polymerization. The temperature rise during curing was recorded in real-time using a T-type thermocouple. RESULTS At 1mm depth, the ACP-composites attained significantly higher conversion (77.8-87.3%) than the control composites based on the same resin (60.5-66.3%). The addition of inert fillers resulted in approximately 5% lower conversion at clinically relevant depths (up to 2mm) for the curing time of 40s. Conversion decline through depths depended on the added inert fillers. Conversion values higher than 80% of the maximum conversion were observed for all of the ACP-composites at depths up to 3mm, when cured for 40s. Significantly higher total temperature rise for the ACP-composites (11.5-13.1 °C) was measured compared to the control composites (8.6-10.8 °C) and the commercial control (8.7 °C). CONCLUSIONS The admixture of inert fillers represents a promising strategy for further development of ACP-composites, as it reduced the temperature rise while negligibly impairing the conversion. CLINICAL SIGNIFICANCE High conversions of ACP-composites are favorable in terms of mechanical properties and biocompatibility. However, high conversions were accompanied with high temperature rise, which might present a pulpal hazard.


Photomedicine and Laser Surgery | 2014

Optical Effects of Experimental Light-Activated Bleaching Procedures

Eva Klarić; mario rakić; Marijan Marciuš; Mira Ristić; Ivan Sever; Zrinka Tarle

OBJECTIVE The purpose of this study was to evaluate the efficiency of experimental light-activated bleaching procedures. BACKGROUND DATA The improved color effect may be attributed to the potential photochemical effect of light-emitting diode (LED405), organic LED (OLED), and femtosecond laser rather than to the photothermal effect of conventional lights used for tooth bleaching. MATERIALS AND METHODS Specially made pastilles of hydroxylapatite were immersed in green tea for 8 h and randomly divided into four groups (n=50) specified by the type of light source applied during a 30 min bleaching treatment: LED405, OLED, and femtosecond laser, or its absence (control group). Each group was treated with five bleaching gels: 10%, 16%, and 30% carbamide peroxide (CP), and 25% and 38% hydrogen peroxide (HP). Changes in color were determined by red-green-blue (RGB) colorimeter and ultraviolet-visible-near-infrared (UV/Vis/NIR) spectroscopy. RESULTS Regardless of the applied bleaching gel, LED405 produced a larger increase in the value of RGB index than did OLED and bleaching without light activation (p<0.05). Femtosecond laser also produced significantly better results in combination with 16% CP and 38% HP. Furthermore, application of a bleaching agent with a higher concentration of peroxide boosted the value of the RGB index. Spectroscopic measurements revealed similar results, although treatments with OLED were rated relatively better than in RGB analysis. CONCLUSIONS The mechanisms of light-activated bleaching procedures had a significant effect on the color change. The bleaching activation with LED405 and higher concentrations of peroxide in bleaching agents promoted better whitening effect.


Acta Clinica Croatica | 2016

MIKROTVRDOĆA BULK-FILL KOMPOZITNIH SMOLA

Katarina Kelić; Sanja Matić; Danijela Marović; Eva Klarić; Zrinka Tarle

The aim of the study was to determine microhardness of high- and low-viscosity bulk-fill composite resins and compare it with conventional composite materials. Four materials of high-viscosity were tested, including three bulk-fills: QuiXfi l (QF), x-tra fi l (XTF) and Tetric EvoCeram Bulk Fill (TEBCF), while nanohybrid composite GrandioSO (GSO) served as control. The other four were low-viscosity composites, three bulk-fill materials: Smart Dentin Replacement (SDR), Venus Bulk Fill (VBF) and x-tra base (XB), and conventional control material X-Flow (XF). Composite samples (n=5) were polymerized for 20 s with Bluephase G2 curing unit. Vickers hardness was used to determine microhardness of each material at the surface, and at 2-mm and 4-mm depth. GSO on average recorded significantly higher microhardness values than bulk-fill materials (p<0.001). The low-viscosity composite XF revealed similar microhardness values as SDR, but significantly lower than XB (p<0.001) and significantly higher than VBF (p<0.001). Microhardness of high-viscosity bulk-fill materials was lower than microhardness of the conventional composite material (GSO). Surface microhardness of low-viscosity materials was generally even lower. The microhardness of all tested materials at 4 mm was not different from their surface values. However, additional capping layer was a necessity for low-viscosity bulk-fill materials due to their low microhardness.


Photomedicine and Laser Surgery | 2015

Real-Time Local Experimental Monitoring of the Bleaching Process

Mario Rakić; Eva Klarić; Ivan Sever; Iva Srut Rakic; Goran Pichler; Zrinka Tarle

OBJECTIVE The purpose of this article was to investigate a new setup for tooth bleaching and monitoring of the same process in real time, so to prevent overbleaching and related sideeffects of the bleaching procedure. BACKGROUND DATA So far, known bleaching procedures cannot simultaneously monitor and perform the bleaching process or provide any local control over bleaching. MATERIALS AND METHODS The experimental setup was developed at the Institute of Physics, Zagreb. The setup consists of a camera, a controller, and optical fibers. The bleaching was performed with 25% hydrogen peroxide activated by ultraviolet light diodes, and the light for monitoring was emitted by white light diodes. The collected light was analyzed using a red-green-blue (RGB) index. A K-type thermocouple was used for temperature measurements. Pastilles made from hydroxylapatite powder as well as human teeth served as experimental objects. RESULTS Optimal bleaching time substantially varied among differently stained specimens. To reach reference color (A1, Chromascop shade guide), measured as an RGB index, bleaching time for pastilles ranged from 8 to >20 min, whereas for teeth it ranged from 3.5 to >20 min. The reflected light intensity of each R, G, and B component at the end of bleaching process (after 20 min) had increased up to 56% of the baseline intensity. CONCLUSIONS The presented experimental setup provides essential information about when to stop the bleaching process to achieve the desired optical results so that the bleaching process can be completely responsive to the characteristics of every individual, leading to more satisfying results.


Journal of Dentistry | 2014

Effect of temperature on post-cure polymerization of bulk-fill composites.

Matej Par; Ozren Gamulin; Danijela Marović; Eva Klarić; Zrinka Tarle


Journal of Molecular Structure | 2013

Degree of conversion and microhardness of dental composite resin materials

Danijela Marović; Vlatko Pandurić; Zrinka Tarle; Mira Ristić; Kristina Šariri; Nazif Demoli; Eva Klarić; Bernard Janković; Katica Prskalo


Lasers in Medical Science | 2015

Temperature rise during experimental light-activated bleaching

Eva Klarić; Mario Rakić; Ivan Sever; Zrinka Tarle


Cancer Genomics & Proteomics | 2013

Genotoxic Effect of Two Bleaching Agents on Oral Mucosa

Eva Klarić; Matej Par; Ivona Profeta; Nevenka Kopjar; Ruzica Rozgaj; Vilena Kašuba; Davor Zeljezic; Zrinka Tarle

Collaboration


Dive into the Eva Klarić's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge