Evangelos Delivopoulos
University of Cambridge
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Evangelos Delivopoulos.
Science Translational Medicine | 2013
Daniel J. Chew; Lan Zhu; Evangelos Delivopoulos; Ivan R. Minev; Katherine M. Musick; Charles Alexander Mosse; Michael Craggs; Nicholas Donaldson; Stéphanie P. Lacour; Stephen B. McMahon; James W. Fawcett
An electronic interface for recording and stimulating nerves that innervate the bladder helps to restore normal bladder function in rats with spinal cord injury. Getting to the Root of Bladder Control Injury to the spinal cord typically results in loss of conscious bladder emptying and the sensation of fullness. Currently, only limited treatment options are available, with most of the patients receiving catheterization. However, this is cumbersome and leads to urological complications including unsolicited episodes of bladder contraction, leading to inappropriate emptying. In a new study, Chew et al. design a “closed-loop” electronic device that can accurately record bladder filling from sensory nerves after spinal cord injury in rat. Using this information, bladder emptying can be artificially stimulated on demand by electrically modulating nerve firing. It is traditionally difficult to record robust neuronal activity from peripheral nerves in vivo. Typically, cuff electrodes are used to record from whole nerves, but produce poor signal quality and provide little indication of bladder filling. Through nerve microdissection, Chew et al. implanted fine-diameter nerves (“rootlets”) into insulated microchannels, recording action potential firing that accurately encoded bladder filling. The device had multiple microchannels for concurrent recording, greatly improving the resolution. Using this sensory information and by manipulating stimulation characteristics, the authors prevented the rat bladder from emptying inappropriately, and bladder contraction was initiated when desired. This work opens a new avenue for the design of a neuroprosthesis for bladder control after spinal cord injury. A severe complication of spinal cord injury is loss of bladder function (neurogenic bladder), which is characterized by loss of bladder sensation and voluntary control of micturition (urination), and spontaneous hyperreflexive voiding against a closed sphincter (detrusor-sphincter dyssynergia). A sacral anterior root stimulator at low frequency can drive volitional bladder voiding, but surgical rhizotomy of the lumbosacral dorsal roots is needed to prevent spontaneous voiding and dyssynergia. However, rhizotomy is irreversible and eliminates sexual function, and the stimulator gives no information on bladder fullness. We designed a closed-loop neuroprosthetic interface that measures bladder fullness and prevents spontaneous voiding episodes without the need for dorsal rhizotomy in a rat model. To obtain bladder sensory information, we implanted teased dorsal roots (rootlets) within the rat vertebral column into microchannel electrodes, which provided signal amplification and noise suppression. As long as they were attached to the spinal cord, these rootlets survived for up to 3 months and contained axons and blood vessels. Electrophysiological recordings showed that half of the rootlets propagated action potentials, with firing frequency correlated to bladder fullness. When the bladder became full enough to initiate spontaneous voiding, high-frequency/amplitude sensory activity was detected. Voiding was abolished using a high-frequency depolarizing block to the ventral roots. A ventral root stimulator initiated bladder emptying at low frequency and prevented unwanted contraction at high frequency. These data suggest that sensory information from the dorsal root together with a ventral root stimulator could form the basis for a closed-loop bladder neuroprosthetic.
Lab on a Chip | 2012
Evangelos Delivopoulos; Daniel J. Chew; Ivan R. Minev; James W. Fawcett; Stéphanie P. Lacour
In this paper we present a compliant neural interface designed to record bladder afferent activity. We developed the implants microfabrication process using multiple layers of silicone rubber and thin metal so that a gold microelectrode array is embedded within four parallel polydimethylsiloxane (PDMS) microchannels (5 mm long, 100 μm wide, 100 μm deep). Electrode impedance at 1 kHz was optimized using a reactive ion etching (RIE) step, which increased the porosity of the electrode surface. The electrodes did not deteriorate after a 3 month immersion in phosphate buffered saline (PBS) at 37 °C. Due to the unique microscopic topography of the metal film on PDMS, the electrodes are extremely compliant and can withstand handling during implantation (twisting and bending) without electrical failure. The device was transplanted acutely to anaesthetized rats, and strands of the dorsal branch of roots L6 and S1 were surgically teased and inserted in three microchannels under saline immersion to allow for simultaneous in vivo recordings in an acute setting. We utilized a tripole electrode configuration to maintain background noise low and improve the signal to noise ratio. The device could distinguish two types of afferent nerve activity related to increasing bladder filling and contraction. To our knowledge, this is the first report of multichannel recordings of bladder afferent activity.
Biomaterials | 2011
Charles P. Unsworth; Hilary Holloway; Evangelos Delivopoulos; Alan F. Murray; Miriam Cather Simpson; Michelle Dickinson; Euan S. Graham
It is estimated that the adult human brain contains 100 billion neurons with 5-10 times as many astrocytes. Although it has been generally considered that the astrocyte is a simple supportive cell to the neuron, recent research has revealed new functionality of the astrocyte in the form of information transfer to neurons of the brain. In our previous work we developed a protocol to pattern the hNT neuron (derived from the human teratocarcinoma cell line (hNT)) on parylene-C/SiO(2) substrates. In this work, we report how we have managed to pattern hNT astrocytes, on parylene-C/SiO(2) substrates to single cell resolution. This article disseminates the nanofabrication and cell culturing steps necessary for the patterning of such cells. In addition, it reports the necessary strip lengths and strip width dimensions of parylene-C that encourage high degrees of cellular coverage and single cell isolation for this cell type. The significance in patterning the hNT astrocyte on silicon chip is that it will help enable single cell and network studies into the undiscovered functionality of this interesting cell, thus, contributing to closer pathological studies of the human brain.
Journal of Neuroscience Methods | 2010
Charles P. Unsworth; Euan S. Graham; Evangelos Delivopoulos; M. Dragunow; Alan F. Murray
In this communication, we describe a new method which has enabled the first patterning of human neurons (derived from the human teratocarcinoma cell line (hNT)) on parylene-C/silicon dioxide substrates. We reveal the details of the nanofabrication processes, cell differentiation and culturing protocols necessary to successfully pattern hNT neurons which are each key aspects of this new method. The benefits in patterning human neurons on silicon chip using an accessible cell line and robust patterning technology are of widespread value. Thus, using a combined technology such as this will facilitate the detailed study of the pathological human brain at both the single cell and network level.
Journal of Biomedical Materials Research Part A | 2010
Evangelos Delivopoulos; Alan F. Murray; John C. Curtis
The increasing use of patterned neural networks in multielectrode arrays and similar devices drives the constant development and evaluation of new biomaterials. Recently, we presented a promising technique to guide neurons and glia reliably and effectively. Parylene-C, a common hydrophobic polymer, was photolithographically patterned on silicon oxide (SiO(2)) and subsequently activated via immersion in serum. In this article, we explore the effects of ultraviolet (UV)-induced oxidation on parylenes ability to pattern neurons and glia. We exposed parylene-C stripe patterns to increasing levels of UV radiation and found a dose-dependent reduction in the total mass of patterned cells, as well as a gradual loss of glial and neuronal conformity to the patterns. In contrast, nonirradiated patterns had superior patterning results and increased presence of cells. The reduced cell adhesion and patterning after the formation of aldehyde and carboxyl groups on UV-radiated parylene-C supports our hypothesis that cell adhesion and growth on parylene is facilitated by hydrophobic adsorption of serum proteins. We conclude that unlike other cell patterning schemes, our technique does not rely on photooxidation of the polymer. Nonetheless, the precise control of oxygenated groups on parylene could pave the way for the differential binding of proteins and other molecules on the surface, aiding in the adhesion of alternative cell types. (c) 2010 Wiley Periodicals, Inc. J Biomed Mater Res, 2010.
IEEE\/ASME Journal of Microelectromechanical Systems | 2008
John C. Curtis; K. Baldwin; B.J. Dworak; J. Stevenson; Evangelos Delivopoulos; Nikki MacLeod; Alan F. Murray
This paper presents a microfabricated planar patch-clamp electrode design and looks at the impact of several physical characteristics on seal formation. The device consists of a patch aperture, 1.5-2.5 mum in diameter and 7-12 mum in depth, with a reverse-side deep-etched 80-mum well. The patch aperture was coated with either thermal oxide or plasma-enhanced chemical vapor deposited (PECVD) SiO2. Some of the thermal oxide devices were converted into protruding nozzle structures, and some were boron-doped. Seal formation was tested with cultured N2a neuroblastoma cells. The PECVD oxide devices produced an average seal resistance of 34 MOmega(n = 24), and the thermal oxide devices produced an average seal resistance of 96 MOmega(n = 59). Seal resistance was found to positively correlate with patch aperture depth. Whole-cell recordings were obtained from 14% of cells tested with the thermal oxide devices, including a single recording where a gigaohm seal was obtained.
PLOS ONE | 2011
Evangelos Delivopoulos; Alan F. Murray
This paper explores the long term development of networks of glia and neurons on patterns of Parylene-C on a SiO2 substrate. We harvested glia and neurons from the Sprague-Dawley (P1–P7) rat hippocampus and utilized an established cell patterning technique in order to investigate cellular migration, over the course of 3 weeks. This work demonstrates that uncontrolled glial mitosis gradually disrupts cellular patterns that are established early during culture. This effect is not attributed to a loss of protein from the Parylene-C surface, as nitrogen levels on the substrate remain stable over 3 weeks. The inclusion of the anti-mitotic cytarabine (Ara-C) in the culture medium moderates glial division and thus, adequately preserves initial glial and neuronal conformity to underlying patterns. Neuronal apoptosis, often associated with the use of Ara-C, is mitigated by the addition of brain derived neurotrophic factor (BDNF). We believe that with the right combination of glial inhibitors and neuronal promoters, the Parylene-C based cell patterning method can generate structured, active neural networks that can be sustained and investigated over extended periods of time. To our knowledge this is the first report on the concurrent application of Ara-C and BDNF on patterned cell cultures.
Information Sciences | 2004
Evangelos Delivopoulos; John B. Theocharis
In this paper a modified algorithm is suggested for developing polynomial neural network (PNN) models. Optimal partial description (PD) modeling is introduced at each layer of the PNN expansion, a task accomplished using the orthogonal least squares (OLS) method. Based on the initial PD models determined by the polynomial order and the number of PD inputs, OLS selects the most significant regressor terms reducing the output error variance. The method produces PNN models exhibiting a high level of accuracy and superior generalization capabilities. Additionally, parsimonious models are obtained comprising a considerably smaller number of parameters compared to the ones generated by means of the conventional PNN algorithm. Three benchmark examples are elaborated, including modeling of the gas furnace process as well as the iris and wine classification problems. Extensive simulation results and comparison with other methods in the literature, demonstrate the effectiveness of the suggested modeling approach.
Colloids and Surfaces B: Biointerfaces | 2015
Evangelos Delivopoulos; Myriam M. Ouberai; Paul Coffey; Marcus J. Swann; Kevin M. Shakesheff; Mark E. Welland
Graphical abstract
international ieee/embs conference on neural engineering | 2011
Evangelos Delivopoulos; Ivan R. Minev; Stéphanie P. Lacour
This communication examines the suitability of a photo-patternable polydimethylsiloxane (PP-PDMS) elastomer as an insulating material for implantable microelectrodes. PP-PDMS is produced by mixing a photoinitiator (2-hydroxy-2-methylpropiophenone) with the PDMS base and curing agent. Subsequent exposure to UV radiation and development of the elastomeric “photo-resist” allows for the definition of well-defined openings within the PP-PDMS film. The dielectric constants of PP-PDMS and PDMS are similar (ε ≈ 2.6, f <;1MHz). Gold film microelectrodes patterned on glass or a PDMS substrate are encapsulated with PP-PDMS, while recording sites as small as 104 μm2 can be obtained in the PP-PDMS layer. The cytotoxicity of the PP-PDMS was preliminary tested in vitro by culturing 3T3 fibroblasts in PP-PDMS extracts. No adverse effects were observed in cultures exposed to PP-PDMS films initially leached in isopropanol solvent for 48h.