Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Fabiana Mantovani Gomes França is active.

Publication


Featured researches published by Fabiana Mantovani Gomes França.


Brazilian Oral Research | 2008

Assessment of the tensile strength of hexagonal abutments using different cementing agents

Carlos Wahl; Fabiana Mantovani Gomes França; Rui Barbosa de Brito; Roberta Tarkany Basting; Henrique Smanio

The aim of this study was to assess the uniaxial tensile strength after thermal cycling in replicas of CeraOne abutments (abutment and coping sets), using four types of cements (n = 10). A zinc phosphate cement (Fosfato de Zinco/ SSW), a resin-modified glass ionomer cement (RelyX luting / 3M-ESPE), a zinc oxide-eugenol cement (ZOE/ SSW) and a zinc oxide cement without eugenol (TempBond NE/ KERR) were used. After cementation, the samples were submitted to thermal cycles (1,000 cycles, 5 degrees C +/- 2 degrees to 55 degrees C +/- 2 degrees) for thirty seconds in each bath. Next, the samples were submitted to the tensile test in a universal test machine (0.5 mm/min). The data were submitted to ANOVA and the Tukey-Kramer test (p < 0.05), and statistically significant difference was found among the cements. The highest tensile strength mean value found was for zinc phosphate cement (33.6 kgf) followed by the resin-modified glass ionomer cement (20.5 kgf), zinc oxide-eugenol cement (8.4 kgf) and the temporary cement (3.1 kgf). Therefore, it was found that the permanent cements presented higher tensile strength, and the temporary cement could be used in situations requiring reversibility and the removal of cemented dental implant-supported prostheses.


Journal of Biomedical Materials Research Part B | 2015

Nanomechanical properties, SEM, and EDS microanalysis of dentin treated with 2.5% titanium tetrafluoride, before and after an erosive challenge.

Roberta Tarkany Basting; Ariene A. Leme; Enrico Coser Bridi; Flávia Lucisano Botelho do Amaral; Fabiana Mantovani Gomes França; Cecilia Pedroso Turssi; A.K. Bedran-Russo

The aim was to assess the nanohardness (H) and the reduced modulus of elasticity (Er ) of 2.5% titanium tetrafluoride (TiF4 ) modified dentin, before and after an erosive challenge with 0.3% citric acid (CA). Exposed dentin surfaces were divided into two groups (n = 5): (1) Control-no dentin pretreatment with TiF4 prior to etching with CA, and (2) Experimental-dentin pretreatment with TiF4  + CA. The H and the Er of intertubular dentin were measured using a triboindenter at different time points: baseline for both groups, after using 2.5% TiF4 for the experimental group, and after using CA for both the experimental and the control groups. Scanning electron microscope and energy dispersive X-ray spectroscopy (EDS) analysis of the dentin surfaces were undertaken at the same time points for both groups. Two-way ANOVA for randomized block design was applied. There was significant interaction between the application of the TiF4 solution and different time points (p = 0.001 for H and p < 0.001 for Er ), identified by Tukeys test. Erosive challenge provided a significant decrease in H and Er mean values. The TiF4 solution caused a significant increase in H and Er values, but no significant differences were found between post-TiF4 and post-CA application. TiF4 application produced a precipitate surface layer on intertubular and intratubular dentin. EDS analysis indicated the presence of titanium. The H and Er of the dentin surface were greatly increased after application of 2.5% TiF4 . TiF4 may modify the micromorphology of the dentin surface and produces an erosive resistance surface.


European Journal of Dentistry | 2014

Comparative evaluation of photodynamic therapy using LASER or light emitting diode on cariogenic bacteria: An in vitro study

Liliana Guimaraes Oliveira Ricatto; Luis Augusto Lopato Conrado; Cecilia Pedroso Turssi; Fabiana Mantovani Gomes França; Roberta Tarkany Basting; Flávia Lucisano Botelho do Amaral

Objective: The aim of this study was to evaluate in vitro the effect of photodynamic therapy (PDT) using LASER or light emitting diode (LED) on cariogenic bacteria (Streptococcus mutans [SM] and Lactobacillus casei [LC]) in bovine dentin. Materials and Methods: Twenty five fragments of dentin were contaminated with SM and LC strands and divided into five experimental groups according to the therapy they received (n = 5): C - control (no treatment), SCLED - no dye/LED application (94 J/cm 2 ), SCLASER - no dye/LASER application (94 J/cm 2 ), CCLED - dye/LED application (94 J/cm 2 ) and CCLASER - dye/LASER application (94 J/cm 2 ). The dye used was methylene blue at 10 mM. Dentin scrapes were harvested from each fragment and prepared for counts of colony forming units (CFU)/mL. The data were analyzed using Kruskal-Wallis, followed by Student-Newman-Keuls (α =0.05). Results: Regarding SM, groups CCLASER and CCLED showed a significant reduction in CFU/mL, which was statistically superior to the SCLASER, SCLED and C groups. Regarding LC, the groups CCLASER and CCLED caused a significant reduction in CFU/mL when compared with SCLASER, which showed intermediate values. SCLED and C had a lesser effect on reducing CFU/mL, where the former showed values similar to those of SCLASER. Conclusions: In conclusion, PDT combined with LASER or LED and methylene blue had a significant antimicrobial effect on cariogenic bacteria in the dentin.


Journal of Applied Oral Science | 2013

Evaluation of bond strength of silorane and methacrylate based restorative systems to dentin using different cavity models

Stephano Zerlottini Isaac; Ana Claudia Pietrobom Bergamin; Cecilia Pedroso Turssi; Flávia Lucisano Botelho do Amaral; Roberta Tarkany Basting; Fabiana Mantovani Gomes França

Objective The aim of this in vitro study was to evaluate the microtensile bond strength (µTBS) to dentin of two different restorative systems: silorane-based (P90), and methacrylate-based (P60), using two cavity models. Material and Methods Occlusal enamel of 40 human third molars was removed to expose flat dentin surface. Class I cavities with 4 mm mesial-distal width, 3 mm buccal-lingual width and 3 mm depth (C-factor=4.5) were prepared in 20 teeth, which were divided into two groups (n=10) restored with P60 and P90, bulk-filled after dentin treatment according to manufacturers instructions. Flat buccal dentin surfaces were prepared in the 20 remaining teeth (C-factor=0.2) and restored with resin blocks measuring 4x3x3 mm using the two restorative systems (n=10). The teeth were sectioned into samples with area between 0.85 and 1.25 mm2 that were submitted to µTBS testing, using a universal testing machine (EMIC) at speed of 0.5 mm/min. Fractured specimens were analyzed under stereomicroscope and categorized according to fracture pattern. Data were analyzed using ANOVA and Tukey Kramer tests. Results For flat surfaces, P60 obtained higher bond strength values compared with P90. However, for Class I cavities, P60 showed significant reduction in bond strength (p<0.05). No statistical difference between restorative systems was shown for Class I cavity model (p>0.05), or between Class I Cavity and Flat Surface group, considering P90 restorative system (p>0.05). Regarding fracture pattern, there was no statistical difference among groups (p=0.0713) and 56.3% of the fractures were adhesive. Conclusion It was concluded that methacrylate-based composite µTBS was influenced by cavity models, and the use of silorane-based composite led to similar bond strength values compared to the methacrylate-based composite in cavities with high C-factor.


Operative Dentistry | 2007

Influence of air abrasion and long-term storage on the bond strength of self-etching adhesives to dentin.

Fabiana Mantovani Gomes França; Alex José Souza dos Santos; José Roberto Lovadino

This study tested the effects of long-term storage and aluminum oxide air abrasion on the bond strength of self-etching adhesive systems. Extracted human third molars were ground flat with 600-grit SiC paper to expose middle coronal dentin. Clearfil SE Bond and One-Up Bond F were applied to dentin surfaces in accordance with manufacturers instructions with or without previous aluminum oxide 50 microm air abrasion. A crown was built up with the resin composite TPH Spectrum and the specimens were stored in water for 24 hours. The bonded assemblies were vertically sectioned into beams for microtensile bond testing. The beams of each tooth were individually immersed in bottles containing water at 37 degrees C for one day, three and six months; the water was changed daily. The specimens were then subjected to microtensile bond testing. The bond strength data were subjected to ANOVA and Tukey Kramer test. Fractured specimens were analyzed in a scanning electron microscope to determine failure modes. Air abrasion improved Clearfil SE Bond bond strength in the three month evaluation. No significant difference was found between the two adhesives systems, but bond strengths gradually decreased over time. Failure modes varied significantly among groups and were influenced by long-term storage and aluminum oxide air abrasion.


Angle Orthodontist | 2014

Role of lubricants on friction between self-ligating brackets and archwires

Renata C. Leal; Flávia Lucisano Botelho do Amaral; Fabiana Mantovani Gomes França; Roberta Tarkany Basting; Cecilia Pedroso Turssi

OBJECTIVE To evaluate the effect of different lubricants on friction between orthodontic brackets and archwires. MATERIALS AND METHODS Active (Quick, Forestadent) and passive (Damon 3MX, Ormco) self-ligating brackets underwent friction tests in the presence of mucin- and carboxymethylcellulose (CMC)-based artificial saliva, distilled water, and whole human saliva (positive control). Dry friction (no lubricant) was used as the negative control. Bracket/wire samples (0.014 × 0.025 inch, CuNiTi, SDS Ormco) underwent friction tests eight times in a universal testing machine. RESULTS Two-way analysis of variance showed no significant interaction between bracket type and lubricant (P  =  .324). Friction force obtained with passive self-ligating brackets was lower than that for active brackets (P < .001). Friction observed in the presence of artificial saliva did not differ from that generated under lubrication with natural human saliva, as shown by Tukey test. Higher friction forces were found with the use of distilled water or when the test was performed under dry condition (ie, with no lubricant). CONCLUSION Lubrication plays a role in friction forces between self-ligating brackets and CuNiTi wires, with mucin- and CMC-based artificial saliva providing a reliable alternative to human natural saliva.


Journal of Applied Oral Science | 2016

Effect of green tea extract on bonding durability of an etch-and-rinse adhesive system to caries-affected dentin.

Carolina Carvalho; Fernando Pelegrim Fernandes; Valéria da Penha Freitas; Fabiana Mantovani Gomes França; Roberta Tarkany Basting; Cecilia Pedroso Turssi; Flávia Lucisano Botelho do Amaral

ABSTRACT Objective Green tea extract has been advocated as a matrix metalloproteinase (MMP) inhibitor; however, its effect on bond durability to caries-affected dentin has never been reported. Thus, the aim of this in vitro study was to evaluate the effect of two MMP inhibitors (2% chlorhexidine and 2% green tea extract), applied after acid etching, on bond durability of an etch-and-rinse adhesive system to caries-affected dentin. Material and Methods Occlusal enamel was removed from third molars to expose the dentin surface, and the molars were submitted to a caries induction protocol for 15 days. After removal of infected dentin, specimens were conditioned with 37% phosphoric acid (15 seconds) and randomly divided into three groups, according to the type of dentin pretreatment (n=10): NT: no treatment; GT: 2% green tea extract; CLX: 2% chlorhexidine. The etch-and-rinse adhesive system (Adper™ Single Bond 2, 3M ESPE, St. Paul, MN, USA) was applied according to the manufacturers instructions, and composite resin restorations were built on the dentin. After 24 hours, at 37°C, the resin-tooth blocks were sectioned perpendicularly to the adhesive interface in the form of sticks (0.8 mm2 of adhesive area) and randomly subdivided into two groups according to when they were to be submitted to microtensile bond strength (μTBS) testing: immediately or 6 months after storage in distilled water. Data were reported in MPa and submitted to two-way ANOVA for completely randomized blocks, followed by Tukey’s test (α=0.05). Results After 24 hours, there was no significant difference in the μTBS of the groups. After 6 months, the GT group had significantly higher μTBS values. Conclusion It was concluded that the application of 2% green tea extract was able to increase bond durability of the etch-and-rinse system to dentin. Neither the application of chlorhexidine nor non-treatment (NT - control) had any effect on bond strength after water storage.


Journal of Applied Oral Science | 2014

Micro-shear bond strength and surface micromorphology of a feldspathic ceramic treated with different cleaning methods after hydrofluoric acid etching

Henrique Caballero Steinhauser; Cecilia Pedroso Turssi; Fabiana Mantovani Gomes França; Flávia Lucisano Botelho do Amaral; Roberta Tarkany Basting

Objective The aim of this study was to evaluate the effect of feldspathic ceramic surface cleaning on micro-shear bond strength and ceramic surface morphology. Material and Methods Forty discs of feldspathic ceramic were prepared and etched with 10% hydrofluoric acid for 2 minutes. The discs were randomly distributed into five groups (n=8): C: no treatment, S: water spray + air drying for 1 minute, US: immersion in ultrasonic bath for 5 minutes, F: etching with 37% phosphoric acid for 1 minute, followed by 1-minute rinse, F+US: etching with 37% phosphoric acid for 1 minute, 1-minute rinse and ultrasonic bath for 5 minutes. Composite cylinders were bonded to the discs following application of silane and hydrophobic adhesive for micro-shear bond strength testing in a universal testing machine at 0.5 mm/min crosshead speed until failure. Stereomicroscopy was used to classify failure type. Surface micromorphology of each treatment type was evaluated by scanning electron microscopy at 500 and 2,500 times magnification. Results One-way ANOVA test showed no significant difference between treatments (p=0.3197) and the most common failure types were cohesive resin cohesion followed by adhesive failure. Micro-shear bond strength of the feldspathic ceramic substrate to the adhesive system was not influenced by the different surface cleaning techniques. Absence of or less residue was observed after etching with hydrofluoric acid for the groups US and F+US. Conclusions Combining ceramic cleaning techniques with hydrofluoric acid etching did not affect ceramic bond strength, whereas, when cleaning was associated with ultrasound, less residue was observed.


European Journal of Dentistry | 2014

Microhardness and color monitoring of nanofilled resin composite after bleaching and staining

Isabel Cristina Gavazzoni Bandeira de Andrade; Roberta Tarkany Basting; José Augusto Rodrigues; Flávia Lucisano Botelho do Amaral; Cecilia Pedroso Turssi; Fabiana Mantovani Gomes França

Objectives: The present study aimed to investigate the effect of staining solutions on microhardness and shade changes of a nanofilled resin composite, which had been previously in contact with bleaching agents. Materials and Methods: A total of 135 disk-shaped specimens (10 mm Χ 2 mm) were fabricated with a nanofilled resin (Filtek Supreme) and photocured with a Light Emission Diode (LED) unit and then allocated into three groups to be bleached with 10% or 16% carbamide peroxide (CP) bleaching agents or a 35% hydrogen peroxide (HP) product. Following bleaching, specimens within each group were subdivided into three groups to be immersed in coffee, red wine or distilled water. Microhardness and color were monitored at baseline, after bleaching and after staining. Results: Analysis of variance for split-plot design showed lower microhardness values when the composite had been in contact with HP (P < 0.0001). The specimens immersed in red wine and coffee provided lower microhardness values than those immersed in distilled water, regardless of the bleaching agent to which the composites were previously exposed. Kruskal Wallis and Dunn tests demonstrated that the composite was lighter after bleaching with a 35% HP agent (P < 0.0500). Conclusion: The composite was darker as a result of being immersed either in red wine or coffee, regardless of the bleaching agent.


Brazilian Oral Research | 2012

Color agreement between nanofluorapatite ceramic discs associated with try-in pastes and with resin cements

Paulo Rigoni; Flávia Lucisano Botelho do Amaral; Fabiana Mantovani Gomes França; Roberta Tarkany Basting

The aim of this study was to evaluate the in vitro color agreement between nanofluorapatite ceramic discs (e.max Ceram / Ivoclar Vivadent / A2) associated with try-in pastes and those bonded with resin cements (Vitique / DMG/ try-in shade A2½ and cement shade A2½, Variolink II / Ivoclar Vivadent / try-in shade A1 and cement shade A1, and Choice 2 / Bisco / try-in shade A2 and cement shade A2), and to evaluate the shade stability of the discs bonded with resin cements. The shades of composite resin discs (Lliss / FGM / A2) and nanofluorapatite ceramic discs with try-in pastes or cements were evaluated according to the Vita Classical shade guide by a digital spectrophotometer (Micro EspectroShade, MHT) immediately after placing the try-in pastes or resin cements between composite resin discs and ceramic discs. Other evaluations were performed at 2, 5, and 6 day intervals after cementation with the resin cements. All ceramic discs that received try-in pastes presented an A2 shade. There was no statistical difference in the shade of the ceramic specimens fixed with different cements at the different intervals, as evaluated by the Friedman test (p > 0.05). Two try-in pastes presented shade compatibility with those recommended by the manufacturers. There was no similarity of shades between the ceramic discs with try-in pastes and those with the respective resin cements. Shade stability was observed in ceramic discs with resin cements within the intervals evaluated.

Collaboration


Dive into the Fabiana Mantovani Gomes França's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

R.T. Basting

State University of Campinas

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alex José Souza dos Santos

Federal University of Rio Grande do Norte

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Cláudia Silami de Magalhães

Universidade Federal de Minas Gerais

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge